| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.5 LAccepted-AOC | 1 | Accepted-AOC Lowest bidder | |
| 2 | 2₹21.7 L+₹27,391.50 (1.28%)Rejected-AOC | 2 | Rejected-AOC 2nd | |
| 3 | 3₹22.9 L+₹1.4 L (6.58%)Rejected-AOC 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | 3 | Rejected-AOC 3rd | |
| 4 | 4₹28.3 L+₹6.8 L (31.7%)Rejected-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | 4 | Rejected-AOC 4th | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Admitted due to no in WLR |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
9 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
PROVN OF PPGL SHEET IN BLDG NO P-8 AND P-20 AND ADDN/ALTN INCUBATION ROOM AND DISPLAY ROOM AT BLDG NO P-12 AND PROVN OF CERTAIN MINOR WORKS AT 12BRD UNDER GE (AF) TUGHLAKABAD
2023_MES_622193_1
GE/TKD-59/2023-24
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹500
GE AF TUGHLAKABAD
₹62,000
Yes
23 Feb 2024
7 Oct 2023
11 Nov 2023
14 Oct 2023
9 Nov 2023
21 Oct 2023
Amount
Excavation in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/loose soil including returning filling in ramming earth in layers not exceeding 25cm, and removing surplus excavated soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point and making good surface complete all as specified and directed by Engr-in-charge.
M&L for Plain Cement Concrete (1:3:6) type C2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as complete all as specified and directed by Engr-in-charge.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161-1979 complete all as specified and directed by Engr-in-charge
S&F framed work as in gusset plate for framed truss, rafters, rails braces etc complete, drilling for fixing of steel sheeting or other covering, door etc to be prepared for hanging or sliding with and including either hook and hinges or steel hanging door fitting etc with welded, riveted or bolted of Fe-410 Gde 250A complete all as specified and directed by Engr-in-charge
M&L for preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed by Engr-in-charge
Cutting holes in brick walls / stone masonry in cement mortar for inserting Purlin/holdfasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) Type B-1 as required exc half but n exc one brick complete all as specified and directed by Engr-in-charge
M&L for bricks works with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in (1:6) complete all as specified and directed by Engr-in-charge
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster (1:4) (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster (1:1/2:2) (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed by Engr-in-charge
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed by Engr-in-charge
M&L for rendering 15 mm thick in CM (1:6) on stone masonry surfaces or on other than fair faces of brick masonry finished fair and even complete all as specified and directed by Engr-in-charge
M&L for 15mm thick rendering in cement mortar (1:4) to fair faces of brick masonry finished even & smooth complete all as specified and directed by Engr-in-charge
M&L for three coats of white washing on new plaster wall surface over primer including preparation of plastered surfaces complete all as specified and directed by Engr-in-charge
M&L for 75 mm thick PCC (1 :4:8) type D2 using 40mm aggregate as in sub base complete all as specified and directed by Engr-in-charge
M&L for 25 mm thick PCC (1:2:4) type B-1, using 20 mm graded stone aggregate as in floors, surfaces finished fair and even complete all as specified and directed by Engr-in-charge
M&L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar (1:6), for laying floor finishes/tiles complete all as specified and directed by Engr-in-charge.
M&L for non skid ceramic tiles 7 to 8mm thick (square / rectangular) area of each tiles exc 0.18 Sqm but not exceeding 0.38 Sqm in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles complete all as specified and directed by Engr-in-charge.
M&L for Non- skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed by Engr-in-charge
M&L for Non- skid coloured ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile complete all as specified and directed by Engr-in-charge.
M&L for 10 mm thick rendering in cement mortar (1:4) to stone masonry wall surfaces or on other than fair faces of brick wall surfaces finished fair & even without using extra cement for fixing tiles etc complete all as specified and directed by Engr-in-charge
M&L for 450x350x7/300 x 200 x 7/350 x 250 x 7mm thick glazed ceramic coloured tiles as in vertical surfaces set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed by Engr-in-charge
M&L for screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6, for laying floor finishes/tiles complete all as specified and directed by Engr-in-charge
M&L for Machine cut Kota stone slab flooring 20-25 mm thick over cement screed base lad and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-charge.
M&L for 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-charge.
M&L for 100 mm thick PCC (1 :4:8) type D2 using 40mm aggregate as in sub base complete all as specified and directed by Engr-in-charge.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed by Engr-in-charge
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-charge
M&L for Machine Pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS- 15658-2006 of 60 mm thickness M-35 grade complete all as specified and directed by Engr-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and fastening and fixing complete FE 290 Gde E-165 complete all as specified and directed by Engr-in-charge.
S&F Mild steel work of angle iron (or flat iron etc for railings, balusters, nosing to steps including embedding in concrete and screwing etc, flat iron for posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc & similar work conforming to Fe 290 complete all as specified and directed by Engr-in-charge.
S&F Mild steel work as in bands, straps, clamp, wall ties conforming to Fe 290 Gde F-165 complete all as specified and directed by Engr-in-charge.
S&F Mild steel Round bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed by Engr-in-charge.
Supply only Chain Link MS galvanized fencing any size and any type complete all as specified and directed by Engr-in-charge.
Fixing only Chain Link MS galvanized fencing including wires any mesh, size and any type of standards rails, straining bolts etc including provision of binding wires complete all as specified and directed by Engr-in-charge.
S&F MS screw bolts (machine made 12 mm dia. Shank) with hexagonal or square heads at one end and screwed at another end, each screwed end to be fitted with washer and one hexagonal or square nut, n exc. 5cm length complete all as specified and directed by Engr-in-charge.
S&F mild steel framed work as in grills, grating etc. with end of bars shouldered and/or riveted, or forged into spikes: framed guard bars: barred iron doors: ladders: frame balusters: walk ways: railing: frame work of water tanks and similar works conforming to Fe-290 Grade-E-165, complete all as specified and directed by Engr-in-charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built with cement mortar (1:4) complete all as specified and directed by Engr-in-charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material outside of MD Land complete all as specified and directed by Engr-in-charge.
Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engr-in-charge.
M&L for preparing newly plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over and including one coat of 1mm thick wall care putty complete all as specified and directed by Engr-in-charge.
M&L for complete removal of existing treatment on walls, chajjas etc including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over and including one coat of 1mm thick wall care putty complete all as specified and directed by Engr-in-charge.
S&F in repair micro perforated square edge and attrite finish mineral fibre (sand micro) of nominal size 595x595x 5mm thick, having building attribute, as in false ceiling, fixed on thick and including grid of size 600x600mm having main of aluminium -T of size 35x25x0.7mm thick cross aluminium -T- of size 25x35x0.7mm thick and wall angle of size 25x25x0.7mm thick, the grid shall be suitable for mineral fibre tiles and hanging from soffits of existing RCC roof slab/iron frame work with using connecting clips/levelling clips all as per manufacture instruction complete all as specified and directed by Engr-in-charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-charge.
M&L for Vitrified ceramic light shade coloured tiles 10mm thick area of each tiles not exc 0.36 Sqm, in floor etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match the shade of the tile complete all as specified and directed by Engr-in-charge.
S&F chequered Plates (rectangular or square) cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for rendering 5mm thick in CM (1:3) on fair faces of ceiling surfaces finished even & smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed by Engr-in-charge.
M&L for wiring with cable of size 1.5 Sqmm single core copper multistrand conductor including continuous earth wire, using cable FRLS insulated (unsheathed) 1100 volts grade conforming to Is-694 drawn in to and including concealed PVC rigid conduit medium duty with all fittings and fixing accessories ISI certified IS 9537 part -3 and terminated in to pressed steel metal flush boxes suitable for modular accessories and including modular cover plates with frame for mounting switches, socket regulator, brackets etc and including necessary cement work including cutting chases pinning in making good to facing and pointing in cement mortar (1:3) to the ends or cutting chases for concealed conduit point wiring and making good disturbed surface complete all as specified and directed by Engr-in-charge. Note: Cutting not exc 4 cm girth and 4 cm width. for followings:-
One light point controlled by one, one way switch
One fan point controlled by one, one way switch and regulator.
One 3 pin socket out let 5 amps independent
One 5 pin 5 amps socket point in same board with other switches.
One 3 pin socket out let 15 amps independent but with cable of size 4.0 Sqmm in point wiring and 2.5 Sqmm in continuous earth wire .
M&L Complete For modular switch one way 6 amps 1 module complete all as specified and directed by Engr-in-charge.
M&L Complete For modular switch one way 16 amps 1 module complete all as specified and directed by Engr-in-charge.
M&L Complete for modular socket 2 in 1, 5 pin 6 amps 2 module complete all as specified and directed by Engr-in-charge.
M&L Complete for modular socket 2 in 1, 6 pin 6A/16 amp 2 module complete all as specified and directed by Engr-in-charge.
M&L complete for modular fan regulator stepped type120 watt 2 module complete all as specified and directed by Engr-in-charge.
M&L complete for ceiling rose surface Bakelite 3 terminal complete all as specified and directed by Engr-in-charge.
M&L complete for pvc/ polycarbonate type Lamp holder, insulated body, with back plate for batten fittings complete all as specified and directed by Engr-in-charge.
S&F energy saving LED lamp 12 Watt, 230 Volts, 50 Hz complete all as specified and directed by Engr-in-charge.
S&F Air circulator fans 230 volt single phase oscillating 450 mm sweep suitable for wall mounting with necessary connection complete all as specified and directed by Engr-in-Charge. Make: Cat Part No FHVVEDXOWH10 of Havells / Crompton /Khaitan
M&L for sub main wiring with single core copper multi strand conductor FRLS flexible insulated (unsheathed) cable of size 2x2.5 Sq mm and 1x1.5 Sq mm as in continuous earth wire drawn into & including PVC conduit medium 25mm dia ISI marked complete with fittings and fixings accessories laid concealed complete. and including necessary cement work including cutting chases pinning in making good to facing and pointing in cement mortar (1:3) to the ends or cutting chases for concealed conduit sub main wiring and making good disturbed surface complete all as specified and directed by Engr-in-charge. Note: Cutting not exc 4cm girth and 4cm width.
M&L for sub main wiring with single core copper multi strand conductor FRLS flexible insulated (unsheathed) cable of size 2x04 Sq mm and 1x4 Sq mm as in continuous earth wire drawn into & including PVC conduit medium 25mm dia ISI marked complete with fittings and fixings accessories laid concealed complete. and including necessary cement work including cutting chases pinning in making good to facing and pointing in cement mortar (1:3) to the ends or cutting chases for concealed conduit sub main wiring and making good disturbed surface complete all as specified and directed by Engr-in-charge. Note: Cutting not exc 4cm girth and 4cm width.
M&L for 1x 20 watts (4 feet) wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation &integrated electronic driver including lamp complete all as specified and directed by Engr-in-Charge.
S&F of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
S&F air cooled split unit air conditioner electric driven (single phase) cooling capacity 2.0 Ton split units indoor/outdoor complete with cordless remote control unit and within built air ionizer and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 complete all as specified and directed by Engr-in-charge. Make: Voltas/ LLYOD/ Hitachi
S&F sheet metal enclosure with two pin socket, chain plug cover with one MCB SP of 32 Amp capacity with alignment 20 KA ‘C’ series including electric connection complete all as specified and directed by Engr-in-charge.
S&F MS stand factory made suitable for condensing unit of split type AC duly powder coated complete all as specified and directed by Engr-in-charge. Make- ISI marked
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5 % and capacity 5 KVA including necessary connections complete all as specified and directed by Engr-in-charge. Make: V-Guard / Microtek / Everest
M&L for earthling with galvanized iron earth plate electrode 600x600x6mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5mtr (B.G.L.) and connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 12mm round bar, including necessary excavation &earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm dia bore, light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead wire protection common salt, charcoal etc complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and directed by Engr-in-charge.
M&L for MCB dist board, sheet steel, phosphatised, powder printed with bus bar, neutral link, earth bar & din rail SPN dist board 08 ways double door complete all as specified and directed by Engr-in-charge.
M&L for MCB single pole & neutral 240 volts, C curve-10 kA, 40-60 Amp complete all as specified and directed by Engr-in-charge.
M&L for MCB single pole 240 volts, C curve-10 kA, 10 Amp complete all as specified and directed by Engr-in-charge.
M&L for MCB single pole 240 volts, C curve-10 kA, 16 Amp complete all as specified and directed by Engr-in-charge.
M&L for MCB single pole 240 volts, C curve-10 kA, 40Amp complete all as specified and directed by Engr-in-charge.
M/S RK Builders
MOHIT ENTERPRISES
V r traders
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .