| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC L1 quoted rates are overall reasonable,hence Accepted | |
| 2 | L2₹17.9 L+₹4.5 L (33.2%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹25.0 L+₹11.6 L (86.1%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
26 May 2020, 6:00 pmClosed
GE(NW)BHNADUP
GE(NW)BHNADUP,MUMBAI
REPAIRS/ REPLACEMENT OF STREET LIGHTS, LT NET WORK AND CONNECTED ITEMS AT INS HAMLA
2020_MES_336943_1
8828/B
Open Tender
Civil Works
Item Rate
274 days
Hamla
For unenlisted contractors scan copy of doc meeting enlistment criteria of MES in cl D cat b(i)
9 documents required · 9 mandatory
₹500
GE(NW)BHNADUP
₹60,000
Yes
17 Oct 2020
31 Mar 2020
1 Jun 2020
31 Mar 2020
26 May 2020
15 Apr 2020
31 Mar 2020 - 9 Apr 2020
Amount
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling including spreading , leveling , watering and well ramming in layers n.exc 25 cm complete all as specified and as directed by the Engineer-in- Charge.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Supply and laying HDPE pipes of pressure rating 6 Kg/Cm sq of size 50 mm laid in trenches complete all as specified and directed.
Supply and laying in repairs GI pipe 40 mm, light grade for the protection of the cable passing through road crossing, etc.
Supply and fix highly efficient multi LED flood light 200 watt with pressure die cast aluminium housing, reflector and enclosed with toughened glass, IP65 including taking down old unserviceable MH flood light fittings complete all as specified and directed. Make :-Havells Cart Part No - JETAPROPLUSFL200WLED757LTG ,Crompton Cat part No-LSFO-200-CDL/60 and equivalent as approved of Luker, Shakti ,Bajaj or C&S
Supply and fix highly efficient multi LED flood light 100 watt with pressure die cast aluminium housing, reflector and enclosed with toughened glass, IP65 including taking down old unserviceable MH flood light fittings complete all as specified and directed. Make :- Havells Cart Part No - JETAIRISFLS100WLED757SYMLTG , Crompton Cat part No-LFLN-100-CDL/60 and equivalent as approved of Luker, Shakti ,Bajaj or C&S.
Supply and fix highly efficient multi LED Street light 70 watt with pressure die cast aluminium housing, reflector and enclosed with toughened glass, IP65 including taking down old unserviceable MH flood light fittings complete all as specified and directed. Make :-Havells Cart Part No - ENDURAPEARLPLUSSL70WLED757PASYTOPC ,Crompton Cat part No-LSTP-72-CDL and equivalent as approved of Luker, Shakti ,Bajaj or C&S.
Supply and fix Decorative LED Post-Top 70 watt made in cast aluminium spigot housing with decorative opal diffuser and IP 65 protection complete including cable connection and taking down existing unserviceable post top lantern complete all as specified and directed. Make :-Havells Cart Part No - SUPREMEPT70WLED730PSYMTOPC or equivalent as approved of Luker, Shakti , Crompton, Bajaj or C&S
Supply and fixing in replacement pole mounting box FRP type of size 155mm x 100mm x 60 mm, 3 phase with locking arrangements, lugs and including necessary nut, bolt and clamps of the flat iron of size 25mm x 4 mm comprising of MCB SP 6 Amps, 240 Volts, 10 KA, 'C' series with proper fixing arrangements on pole / wall complete all as specified and directed. Make: National/ Sintex
M & L in repairs for sub main wiring PVC copper cable 2.5 sqmm (02 Run & 01 Run of 1.5 sqmm) copper conductor 1100 Volt grade multi core multi stranded PVC insulated unsheated drawn through and including PVC conduit and accessories fixing on poles/ wall with clamps, nuts bolts etc from FRP box to street light fiting complete all as specified and directed.
Taking down existing LT/UG cable from existing wall by removing unserviceble clamps and fixing back by providing new clamps complete all as specified and directed by Engineer in charge for the 16/25/35/95/30/50 sqmm 3.5/4 and 2 core sizes
Material & Labour sand filling under floors or in foundation including watering & consolidation for cable cushioning all as specified and directed
Supply and laying un-reinforced pre cast concrete cable cover, class LV type 2 with peak size 300mm x 180mm x 40mm
Supply and laying GI pipe 50 mm, light grade for the protection of the cable passing through road crossing, etc.
M & L for straight through joint heat shrinkable type for underground LT cable 1100 volt complete all as specified and directed by Engineer in charge for the sizes 10 Sqmm 4/2 core
All as per item No 16.00 here-in-before but for cable size 16 Sqmm 4/2 core
All as per item No 16.00 here-in-before but for cable size 25/35 Sqmm 3.5/4 core
All as per item No 16.00 here-in-before but for cable size 50 to 95 Sqmm 3.5 Core
All as per item No 16.00 here-in-before but for cable size 120 to 185 Sqmm 3.5 core
Supply and fix in repairs MCCB 4 pole 160 Amps 415Volt 50Hz breaking capacity 36KA adjustable type complete all as specified and directed. (Legrand cat no. 420097, or eqivalent GE ,schneider
Supply and fix in repairs MCCB 4 pole 200 Amps 415Volt 50Hz breaking capacity 36KA adjustable type complete all as specified and directed. (Legrand cat no. 420097, or eqivalent GE ,schneider
Material and labour for earthing complete with GI earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground lavel) with top edge of the plate not less than 1.5mtr below normal ground lavel connected to GI earth strip 32X6 mm by mean of bolts, nuts, check nuts and washer of brash all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover fullel with watering pipe, wire mess and copper lugs etc GI protection pipe 40 mm dia medium grade including testing on completion all as specified and directed.
Supply and laying in repairs cable LT XLPE insulated and screened PVC bedded, galvanised steel strip armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade complete all as specified and directed by Engineer in charge for the 95 Sqmm 3.5 Core. size including taking down existing u/s LT cable.
All as per item No 20.00 here-in-before but for cable size 70 Sqmm 3.5 Core.
All as per item No 20.00 here-in-before but for cable size 50 Sqmm 3.5 Core.
All as per item No 20.00 here-in-before but for cable size 35 Sqmm 3.5 Core.
All as per item No 20.00 here-in-before but for cable size 16 sqmm 4 core
All as per item No 20.00 here-in-before but for cable size 16 sqmm 2 core
All as per item No 20.00 here-in-before but for cable size 10 sqmm 2 core
Supply and fix in repairs LT cable route indicator made out of cast iron 10cm dia duly engraved with letters 'LT CABLE 1100 volts' fixed in 20mm x 20mm equal angle 60cm long including provision of PCC block of 20cm x 20cm complete all as specified and directed.
cooltech engineering services
NOEL ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .