Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.1 LAccepted-AOC DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | L1 | Accepted-AOC L1 | |
| 2 | L2₹51.1 L+₹1.8 L (3.61%)Rejected-Finance SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹51.3 L+₹2.0 L (3.96%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹55.3 L+₹6.0 L (12.1%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹56.3 L+₹6.9 L (14.1%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
24 Nov 2023, 6:00 pmClosed
GE Minniebay
GE Minniebay Juglighat Post Minniebay Port Blair 744103
REPAIR / MAINT OF DG SET AT NTS, NAD, DAD, MARCOS, CHOULDARI, PROTHRAPUR FILTRATION PLANT AND LT DISTRIBUTION SYSTEM, LT CABLE, MCCB, LT PANEL CHANGE OVER AND CONNECTED WORKS UNDER AGE E/M II AT GE MININEBAY, PORT BLAIR
2023_MES_625361_1
8314/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Minniebay Port Blair
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE Minniebay
₹95,000
Yes
9 Jan 2024
27 Oct 2023
27 Nov 2023
28 Oct 2023
24 Nov 2023
11 Nov 2023
Amount
M & L for Inspection and carrying out B-Checks of DG Set Once in 300 Hours of run or 6 months whichever is earlier installed at various locations by representative / authorized Service Engineer of OEM of the DG Set including inspection, maintenance, changing lub oil filters, fuel filters, by pass filter and water filter and servicing of DG Set including checking of Alternator and its connections, Non AMF / AMF Panels connected to DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, check / adjust Belts, checking Battery Voltage, Water Level and checking Fan Hub / Air Blower Hub and Water Pumps, cleaning of electrical connections, checking of safety controls, cleaning of Engine including cleaning of Air Filter, Corrosion Inhibitor, O Ring, Gaskets, Screws etc. checking of engine oil thickness, and draining out old engine oil from oil chamber, if density of engine oil is increased. And topping up of engine oil , if engine oil density is found satisfactory. and removing deposited material including tightening of all inlet and outlet connections and replacing minor items such as detoriated clamp, screws, washers etc., cleaning of Roof, Floor of the DG Set Room complete all as specified and as directed.
Note: The B Check includes carrying out preventive maintenance including replacing minor unserviceable / worn out spares to keep the DG set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips,washers, distilled water, electrolyte, etc. All other spares , engine oil, coolant will be measured and paid seperately as supply only under relevant items of this schedule, Contractor has to attend the break down within the four hours of telephonic intimation form executive at any time and place during the contract period. General maintenance is indicative only contractor has to carryout other necessary maintenance task also as required and directed by Engineer in Charge. Items for oil change/top up will be measured under relevant items of schedule ‘A’ Penalty is to be levied for not attending complaints, as per delay mentioned below :- (a) First 4 hours delay– Rs.2000/- (b) 4-8 Hrs delay –Rs.4000/- (c) 8-12 Hrs delay -6000/- (d) 12-16 Hrs delay -8000/- (e) 16-20 Hrs delay -10000/- (f) 20-24 Hrs delay -12000/- (g) For one day delay is 12000/- multiplied by no of days delayed. Note :- For item Sl. No. 1.00 to 8.00 supply of Engine oil, coolant shall be supplied and paid separately form relevant schedule item
All as per item above DG set of capacity 500 KVA
All as per item No.1.00 above but for DG set of capacity 250 KVA
All as per item No.1.00 above but for DG set of capacity 200 KVA
All as per item No.1.00 above but for DG set of capacity 125 KVA
All as per item No.1.00 above but for DG set of capacity 82.5 KVA
All as per item No.1.00 above but for DG set of capacity 62.5 KVA
All as per item No.1.00 above but for DG set of capacity 30 KVA
Supply, fixing in replacement of Air filter of 500 KVA DG set complete all as specified and directed by Engineer-in-charge. make : Cummins
Supply , fixing in replacement of Air filter of 200 KVA / 250 KVA DG set all as specified and directed by Engineer-in-charge Make: Kirloskar/Cummins/Greaves`
Supply , fixing in replacement of Air filter of 20/62.5/82.5/125 KVA DG set all as specified and directed by Engineer-in-charge Make: Kirloskar/Cummins/Greaves`
Supply & fixing in replacement of water pump assly in 200 / 250 / 500 KVA DG set make Cummins / Kirloskar
Supply & fixing in replacement of water pump assly in 20 / 62.5 / 82.5 / 125 KVA DG set make Cummins / Kirloskar / Greaves
Supply and pouring engine oil for DG set grade oil 20W40 complete all as directed Make : I O C Servo
Supply and pouring engine oil for DG set grade oil 15W40 complete all as directed Make : I O C Servo
Supply and pouring coolant for radiator of DG set of any capacity of DG set make: Cummins / Kirloskar / Greaves
Supply pouring distilled water for radiator and batteries of DG set
M & L for repair and reconditioning the starting motor 12 V DC system including taking out the defective starter from 30-125 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, solenoid switch assly, bushes, commutator unit, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge
M & L for repair and reconditioning the starting motor 24 V DC system of kirloskar make including taking out the defective starter from 500 KVA / 250/ 200 KVA capacity DG set , complete dismantling and repair and replacing the carbon brushes with holder, bushes, starting coil, etc refixing the same in the DG set and connecting with the circuit including all required items, starting and testing all as specified and directed by Engineer-in-charge
Dismantling the battery charge alternator 12 V DC from engine, carryingout repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 20/ 62.5 / 82.5 KVA / 125 KVA DG set all as specified and directed by Engineer-in-charge
Dismantling the battery charge alternator 24 V DC from engine, carryingout repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 200/ 250 / 500 KVA DG set all as specified and directed by Engineer-in-charge
M & L for supply, fixing in replacement of PT fuel pump of 200 / 250 /500 KVA DG set by taking out the defective defective fuel pump, renewing the worn out parts, seals, o rings, governor weight carriers, carryingout repair and calibration of PT fuel pump and fixing back in the engine and testing on load all as directed by Engineer-in-Charge
M & L for supply, fixing in replacement of fuel pump of 20 /62.5/82.5/125 KVA DG set by taking out the defective defective fuel pump, renewing the worn out parts, seals, o rings, governor weight carriers, carryingout repair and calibration of fuel pump and fixing back in the engine and testing on load all as directed by Engineer-in-Charge
M & L for supply, installation and commissioning in replacement of AVR in 20 /62.5/82.5/125 KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge make Kirloskar / Altex / Senlec
M & L for supply, installation and commissioning in replacement of AVR in 200/250KVA DG set by taking out the defective AVR from DG set alternator from its control circuit, fixing the new AVR and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge make Kirloskar / Altex / Senlec
M & L for supply, fixing in replacement of AVR for excitation under Cummins AUX 105 by removing the defective unit from alternator and fixing back new and connecting with system and commisioning and testing complete make: Cummins/Senelec
S & Fixing including testing in replacement of the lead acid battery 12 V DC 180 AH including the initial charge, terminals connector make : Exide / SF / Lucas
S & Fixing including testing in replacement of the lead acid battery 12 V DC 100 AH including the initial charge, terminals connector make : Exide / SF / Lucas
S & Fixing including testing in replacement of the lead acid battery 12 V DC 150 AH including the initial charge, terminals connector make : Exide / SF / Lucas
M & L for supply and fixing in replacement of engine fuel hose assly along connector for 200 / 250/ 500 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge
M & L for supply and fixing in replacement of engine Lube oil hose assly along adaptor for 200 /250/500 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge
M & L for supply and fixing in replacement of engine coolant hose and clamp for 200/250/500 KVA DG set by taking out the detoriated hoses from engine, replacing and connecting starting and testing all as directed by Engineer-in-charge
M & L for supply, fixing in repair coil electrical in STC control valve in 500 KVA DG set as specified and directed by Engineer-in-charge
M & L for supply fixing in repairs magnetic pick up suitable for 30 /62.5 /82.5 /125 /200 / 250 / 500 KVA DG set by taking out the defective unit from engine , replacing the same and adjusting the gap setting. Connecting in the circuit all as specified as directed by Engineer-in-charge
S & Fixing in repairs Low lub oil pressure safety control in DG set and connecting with DG set system of 30 KVA to 250 KVA all as directed by Engineer-in-Charge
S & Fixing in repairs High water temperature trip safety 30 KVA to 500 KVA DG set and connecting with DG set system all as specifiied and directed by Engineer-in-charge
M & L for supply, fixing in replacement of fuel oil pressure sensor in 500 KVA DG set all as directed by Engineer-in-Charge
M & L for supply, fixing in replacement of lub oil pressure sensor in 200 /250 / 500 KVA DG set all as directed by Engineer-in-Charge
M & L for supply, fixing in replacement of lub oil pressure sensor in 30 KVA to 125 KVA DG set all as directed by Engineer-in-Charge
M & L for supply, fixing in replacement of valve door gasket in 30 KVA to 250 KVA DG set all as directed by Engineer-in-Charge
S & Fixing in replacement of fan belt suitable for 500 KVA DG set all as specified and directed by Engineer-in-charge
S & Fixing in repair shutdown valve in 200 / 250 / 500 KVA DG set as specified and directed by Engineer-in-charge
S & fixing in replacement of solid state potentiometer in 200 / 250 / 500 KVA and testing as specified and directed by Engineer-in-charge
S & fixing in replacement of dynamo belt in 30 KVA to 500 KVA and testing as specified and directed by Engineer-in-charge
S & Fixing in repair and rewinding the excitor stator field assembly of 200 / 250 / 500 KVA by takingout complete burnt coils, cleaning and rewinding the same by supper enamel copper wire, insulalting the coils with nomex paper, milinex sheet, heating and varnshing by varnish materials and applying one coat of bectol anti rust protection, fixing back in to the alternator, connecting teh cables, starting and testing all as specified and directed by Engineer-in-charge
M & L for taking down unserviceable starting motor from the engine 500 KVA / 200 KVA and supply and fixing starter assly and connecting with circuit and testing complete all as directed.
M & L for taking down unserviceable starting motor from the engine 62.5/82.5/125 KVA and supply and fixing starter assly and connecting with circuit and testing complete all as specified and directed by Engineer-in-charge.
Dismantling the injector assly by taking out valve door covers, rocker levers in 30 KVA to 250 KVA DG set and dismantling and servcing by replacing the defective repair kit assembling and calibrating the same and fixing back in to the engine including renewing valve door covers and adjusting timing, starting and testing the DG set on load all as specified by Engineei-in-charge
Taking out ACB breaker for repair and servicing by disconnecting and dismantling the ACB breaker rating 2000 Amps / 1000 Amps / 800 Amps make L&T by carrying out repair/ servicing , checking and renewing the defective shunt trip coil & UV trip 230 V AC , checking and rectifying the defective CTs and rectifying the mechanism operation including spring charge system, reinstalling the same in the panel and providing necessary line and connections all as directed by Engineer-in-charge. Note: The spare required for repairs will be measured and paid seperately
Supply only of shunt release coil 240 V AC all as per sample complete all as specified and directed by Engineer-in-charge.
Supply only of Closing coil 240 V AC all as per sample complete all as specified and directed by Engineer-in-charge.
Supply only of undervoltage coil 240 V AC all as per sample complete all as specified and directed by Engineer-in-charge.
Supply only of spring charging motor suitable for fixing in ACB of make L&T "C" Series operated in 240 V AC supply all as specified
Supply only of microprocessor based protection release for ACB all as specified and as directed
Supply only of phase indicator lamps R, Y, B LED type
Dismantling the engine turbo charger assly by taking out aircleaners, after cooler housing and its connected accessories in 62.5 KVA to 250 KVA DG set no complete dismantling and servcing by replacing the defective wheel and shaft, compressor wheel and repair kit, assembling the turbo charger and fixing back in to the engine and mouting, starting and testing the DG set on load all as specified by Engineei-in-charge. Note The spare required for repairs will be measured and paid seperately
Supply only of kit turbo charger
Supply only of Gasket mounting
Supply only of screw hexegonal Head cap
Supply only of nut lock
M & L for fixing in repair and commissioning battery charging alternator 12V / 24 V DC in DG sets complete all as specified and directed by Engineer-in-charge.
M & L for taking down unserviceable solenoid switch from starter motor of 500 KVA, opening and removing bunrt defective parts, replacing by new solenoid switch and connecting with contacts and testing complete all as specified and directed by Engineer-in-charge.
M & L for replacement of battery lead 1.25 Mtr long consisting of multistranded copper conductor PVC insulated single core cable of 75 Sqmm size connected with 1 No battery terminal clamp at one end and copper lug at other end complete all as specified and directed by Engineer-in-charge.
M & L for supply and fixing of Engine display control (Microprocessor based type) by taking out the defective unit from 30 KVA to 250 KVA capacity DG set complete checking the panel and its connection circuit in the panel board, providing proper interlink (programming) connection with DG set including all required items, starting and testing all as specified and directed by Engineer-in-charge Make: C & S / Cummins / Kirloskar / Deep sea / L&T
Inspecting and repairs in the synchroniser panel for its proper operation and carrying out the following (a) Tracing out faults caused by defective components including relays, contactors, connectors, battery charger etc by taking down the old components and replacing with new one. (b) Checking the control wiring for any defects, tightening the connections and securing any open point with insulation tape. (c) Inspecting the synchronising controller for alarms caused by faults within the system and addressing the faults. Checking the settings of the synchorising controller for its proper functionality. Note: The components required replacement shall be measured and paid separately under relevant items of the schedule.
Supply only of Emergency off push buttons with mushroom head, push-turn fuction with 1NO and 1 NC complete all as specified and directed by Engineer-in-charge.
Supply only of Push button flush head type of red/green colour suitable for operation in 24 VDC/ 220V AC complete all as specified and directed by Engineer-in-charge.
Supply only of control plug in relay 24 V DC, 6 A complete all as specified and directed by Engineer-in-charge.
M&L for Painting of diesel generator canaophy of capacity 250 KVA DG set by applying with two coat of synthetic enamel paint heat resistant of approved quality and colour by spray painting after preparation of old paint surface including stickering of MES no., DG set details, etc all as specified and directed by Engineer-in-charge
Painting of diesel generator canaophy of capacity 250 KVA DG set by applying with two coat of synthetic enamel paint heat resistant of approved quality and colour by spray painting after preparation of old paint surface including stickering of MES no., DG set details, etc all as specified and directed by Engineer-in-charge Note :- All items for spray painting should be arranged by the contractor
S & F in repair rotating rectifier kit diode set ( 6 nos ) suitable for 500 KVA DG set all as specified and directed by Engineer-in-charge
S & F in repair rotating rectifier kit diode set ( 6 nos ) suitable for 30 KVA to 250 KVA DG set all as specified and directed by Engineer-in-charge
S & F in replacement of fan belt (sets) suitable for 30 KVA to 125 KVA DG set all as specified and directed by Engineer-in-charge
S & F in replacement of fan belt (sets) suitable for 250 KVA / 200 KVA DG set all as specified and directed by Engineer-in-charge
S & F in replacement of solenoid on / off switch for FIP fuel pump of DG set capacity 30 KVA to 125 KVA KVA DG set suitable for kirloskar make engine and cooecting with circuit system all as directed by Engineer-in-Charge
S & Fixing in replacement of battery charger automatic SMPS type 220 V AC input and 24/12 V DC, 10 Amps output with auto cut off, floating, indicating maters, lamps, connectig in the exisitng circuit and testing all as specified and directed by Engineer-in-charge
Material and labour for carrying out in replacement of the Electronic Governor Control (EGC) in 30 KVA to 250 KVA DG set by taking out the defective parts from DG set, fixing new controller in the engine and connecting with circuits, starting and testing the DG set on load complete all as specified and directed .
M & L for supply, fixing in replacement of under voltage relay 415 V AC suitable for MCCB breaker of 200 KVA DG sets conecting and testing all as specified and directed by Engineer-in-charge make: L&T/C&S//Crompton
M & L for supply, fixing in replacement of copper multistrand wire size 2.5 sqmm ,1.1 KV with required lugs and flexible wire and connecting in control panel as per requiremet at site all as and directed by Engineer-in-charge make: Havells/Finolex
S&Fixing in repairs of start and stop control PCB control unit suitable for 30 /62.5 / 82.5 /125 KVA DG set make: Cummins / Kirloskar
M & L for supply, installation and commissioning in replacement of Actuator in 200 KVA to 500 KVA DG set by taking out the defective Actuator from enginet, fixing the new Actuator and connecting in the circuit, thorough checking and testing the DG set on load all as directed by Engineer-in-Charge
S&Fixing in repairs of low coolant water level sensor suitable for 500 KVA DG set make: Cummins
M&L for repairs to radiator assembly of 30 KVA DG set designing by taking out from DG set and transporting to workshop for required repairs and bringing back after repairs and reinstating the same and testing on load complete all as specified and as directed for the following DG sets: Note: The repair work shall involve welding/soldering ,descalling the assembly tank by filling up and stearing the descalling solutions (i.e. soda and concentrated liquid) with permissible pressure, cleaning the tubes with brushes. After cleaning, the leaking tubes and radiator body shall be repaired with soldering and brazing in sufficient size and re-assembling complete in unique shape all as directed. The radiator of DG set shall be suitably fixed by means of nuts, bolts, washers and packing, etc. as required
All as per item No.85.00 above but for DG set of capacity 62.5/82.5/125 KVA
All as per item No.85.00 above but for DG set of capacity 200/250 KVA
All as per item No.85.00 above but for DG set of capacity 500KVA
Supply, installation and commissioning in replacement of radiator for 200/250 KVA DG set including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, shroud of radiator, connecting cooling pipes inlet and outlet all as directed by Engineer-in-Charge.
Supply, installation and commissioning in replacement of radiator for 200/250 KVA DG set including dismantling of old / defective radiator, taking out from DG set base frame, fixing the new radiator assembly, shroud of radiator, connecting cooling pipes inlet and outlet all as directed by Engineer-in-Charge.
M&L for scrapping out old paint from base frame and external body surfaces of 200 KVA DG sets with emery paper and painting with two coats of synthetic enamel paint (of approved tint) with spray gun including minor repairs to canopy as required complete all as specified and as directed for the following DG sets. Note :- All items for spray painting should be arranged by the contractor.
S & fixing in replacement of alternator terminal connector in 200/250 KVA by taking out the burnt connector from alternator, checking cable lugs and connecting in the new terminal and tightening and testing at NTS power house all as specified and directed by Engineer-in-charge.
S & fixing in replacement of alternator terminal connector in 30 KVA to 125 KVA by taking out the burnt connector from alternator, checking cable lugs and connecting in the new terminal and tightening and testing at NTS power house all as specified and directed by Engineer-in-charge.
M & L in replacement of DG Set door Hinges & accessories,for 20 / 62.5/82.5 / 250 KVA all as specified & directed .
S&F in replacement of Anti Vibration Mounting bracket in 250 KVA DG set for Engine mounting foot including dismantling and taking out from mounting with using chain pully and testing complete all as specified and directed by Engineer-in-charge.
M&L in servicing of alternator capacity 200/250 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insulation tapes, heating and improving the insulation of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, replacing both bearings, assembling all removed parts in the alternator, fixing back into the engine and coupling and carrying out alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load allas specified and directed by Engineer-in-Charge.
M&L in servicing of alternator capacity 62.5/82.5/125 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insulation tapes, heating and improving the insulation of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, replacing both bearings, assembling all removed parts in the alternator, fixing back into the engine and coupling and carrying out alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load allas specified and directed by Engineer-in-Charge.
M & L for taking down stator assembly of alternator by disconnecting electrically and mechanically taking to work shop for rewinding incl removing burnt coils, insulating material complete cleaning with CTC and rewinding with same gauge ISI marked winding wire complete with insulating paper and Dr Beck varnish baking / heating and bringing back to installatin refixing , connecting elecrtically and mechanically and testing on completion of work complete all as directed for DG set of capacity 200/250 KVA complete all as specified and directed
M & L for taking down stator assembly of alternator by disconnecting electrically and mechanically taking to work shop for rewinding incl removing burnt coils, insulating material complete cleaning with CTC and rewinding with same gauge ISI marked winding wire complete with insulating paper and Dr Beck varnish baking / heating and bringing back to installatin refixing , connecting elecrtically and mechanically and testing on completion of work complete all as directed for DG set of capacity 62.5/82.5/125 KVA complete complete all as specified and directed by Engineer-in-charge.
M&L for cleaning of fuel tank made of MS sheet up to 20 to 125 KVA DG Sets by draining out fuel in a separate container, taking out all silt / dirt deposition inside the tank, cleaning it completely by manual and necessary T&P and refitting and connecting with fuel pipes complete all as specified and directed by Engineer-in-charge.
M&L for cleaning of fuel tank made of MS sheet up to 200 KVA to 500 KVA DG Sets by draining out fuel in a separate container, taking out all silt / dirt deposition inside the tank, cleaning it completely by manual and necessary T&P and refitting and connecting with fuel pipes complete all as specified and directed by Engineer-in-charge.
S&F in replacement of 3 pole ML- 4 Contactor, heavy duty with aux contacts 415 Volt all as per existing make and model complete all as specified and directed by Engineer-in-charge.
S&F in replacement 4 pole MNX 45 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 200 KVA, thorough checking, connecting with the system, testing both Auto and manual mode conforming to IEC-60947 all as specified as directed by Engineer-in-charge
S&F in replacement of 220/415 Volt spare coil suitable for MCX-41 Contactor as per existing make and model complete all as specified and directed by Engineer-in-charge.
S&F in replacement of 220/415 Volt spare coil suitable for MCX- 32 / 33 Contactor as per existing make and model complete all as specified and directed by Engineer-in-charge.
S&F in replacement of 220/415 Volt spare coil suitable for MNX 45 Contactor as per existing make and model complete all as specified and directed by Engineer-in-charge.
S&F in replacement 4 pole MCX 32 / 33 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 62.5 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation complete all as specified and directed by Engineer-in-charge.
S&F in replacement 4 pole MCX 41 contactor heavy duty with aux contacts 415 V, all as per IS, in existing AMF control panel of DG set 125 KVA, thorough checking, connecting with the system, testing both Auto and manual mode operation complete all as specified and directed by Engineer-in-charge.
M & L for replacement/repair of existing LT Panel /indoor/door/ hinges/locking arrangment welding with good finishing of the same /with two coate of synthetic enamil paint of existing colur etc. and directed by Engineer-in-charge.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for laying of UG cables etc and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc 25 cm for soil complete all as specified and directed by Engineer-in-charge.
Removing excavated materials n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point for soil complete all as specified and directed by Engineer-in-charge.
M & L for Plain Cement Concrete 1:4:8 type D2 using 40 mm graded stone aggregate for foundation of poles1.5mtr depthx.6mtr wedth complete all as specified and directed by Engineer-in-charge.
Supply and lay in replacement of UG cable XLPE insulated armoured and PVC sheathed LT 1100 volts grade with aluminium conductor stranded of following sizes including suitable gland, crimping of lugs complete all as specified and directed by Engineer-in-charge. :- Note : Earthwork shall be measured and paid separately.
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of 77 mm (OD) and 63 mm (ID) polythylene including coupler & Bend with smoooth inernal and profiled external surface for under ground cable protection complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement Volt/Ammeter (0-500V/0-400A) CT operated square type 96x96mm including dismantling of unserviceable ammeter ,connecting the cable complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement indication lamp R/Y/B with base including dismantling of unserviceable indication lamp ,connecting the cable complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement multifunctional digital meter and fixed in existing panels including dismantling of unserviceable indication lamp ,connecting the cable complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement MCCB 63 Amps, 4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: adjustable thermal & Fixed Magnetic setting complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement MCCB 100 Amps, 4 pole, 415 volt, breaking capacity 35 KA conforming to IS 13647-II: adjustable thermal & Fixed Magnetic setting complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement MCCB 125 Amps, 4 pole, 415 volt, breaking capacity 35 KA conforming to IS 13647-II: adjustable thermal & Fixed Magnetic setting complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement MCCB 160 Amps, 4 pole, 415 volt, breaking capacity 35 KA conforming to IS 13647-II: adjustable thermal & Fixed Magnetic setting complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement MCCB 200 Amps, 4 pole, 415 volt, breaking capacity 35 KA conforming to IS 13647-II: adjustable thermal & Fixed Magnetic setting complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement MCCB 250 Amps, 4 pole, 415 volt, breaking capacity 35 KA conforming to IS 13647-II: adjustable thermal & Fixed Magnetic setting complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement MCCB 320/400 Amps, 4 pole, 415 volt, breaking capacity 35 KA conforming to IS 13647-II: adjustable thermal & Fixed Magnetic setting complete all as specified and directed by Engineer-in-charge.
Taking down old unsesrviceable digital timer of any make and capacity from existing panel and supply and fix new digital time switch programmable evry 3 to 30 Sec , with backup of 6 years, 28 memory locations, current carrying capacity up to 16 Amps, weekly programmable with 1 change over complete all as specified and directed by Engineer-in-charge.
Supplying and laying (in trenches/duct/fixing to pole/wall or in such similar position ) in replacement of existing unserviceable GI tubing light grade ISI marked for cable protection of following sizes:- Note : Earthwork if required shall be measured and paid separately.
80 mm dia
50 mm dia
40 mm dia
Supply & fix in replacement aluminium strip 25x3.15mm with saddles and fixing screws etc.for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-charge.
Supply & fix in replacement galvanised iron strip 32 x 6 mm burried in ground complete all as specified and directed by Engineer-in-charge.
Taking down of old unsv XLPE cable, Supply and laying in replacement of UG cable XLPE insulated armoured and PVC sheathed LT 1100 volts grade with aluminium conductor stranded of following sizes including suitable gland, crimping of lugs complete all as specified and directed by Engr-in-Charge. Note : Necessary earthwork shall be measured and paid separately
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
400 Sqmm 3.5 core
Taking down of old unsv DWC Pipe, Supply, laying of telerax DWC (double wall corrugated) HDPE pipe ISI marked of outer dia of 120mm and inner dia 103mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and directed by Engr-in-Charge
Supply and replacement of Routine maintenancechart / Preventive maint schedule / layout of DG set / Motor incoming and out going cable with writing of all details complete all as directed by Engineer-in-Charge. (Board colour -Blue/Black/White)
Repair / servicing of Automatic power factor correction panel at NTS Sub station NAD power house, area by thorough checking and removing defective meters and controls and capacitors etc, replacing burnt cables and lugs with new items as required and testing complete all as specified and directed by Engineer-in-charge. Note : The items required for replacement shall be measured and paid seperately under respective items here in after
Supply and fix in replacement Micro processor based automatic power factor correction relay complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement power capacitor heavy duty 5 KVAR capacity , 415 VMNX - 32 with coil voltage 240/415 V complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement power capacitor heavy duty 10KVAR capacity , 415V complete all as specified and directed by Engineer-in-charge.
Supply fix in replacement power capacitor heavy duty 25KVAR capacity , 415V complete all as specified and directed by Engineer-in-charge.
S&F in replacement on load change over switch capacity 100 Amps, 415 V, 4 Pole,sheet metal enclosure, along with operating handle including connecting in the existing circuit connection, required modification works complete all as specified and directed by Engineer-in-charge.
S&F in replacement on load change over switch capacity 125 Amps, 415 V, 4 Pole,sheet metal enclosure, along with operating handle including connecting in the existing circuit connection, required modification works complete all as specified and directed by Engineer-in-charge.
S&F in replacement on load change over switch capacity 160 Amps, 415 V, 4 Pole,sheet metal enclosure, along with operating handle including connecting in the existing circuit connection, required modification works complete all as specified and directed by Engineer-in-charge.
Attending and Repair to Three phase input output true online UPS system ((IGBT based - inverter & converter both) with capcity 15 KVA, soldering and testing complete including interlink cables (to connect batteries) and DC cables up to 5 meter (to connect battery bank with UPS) all as specified and directed by Engineer-in-Charge. Note : All spares which to be replaced with new one shall be measured and paid separately.
Supply only Battery EP-42 AH all as specified and directed by Engr-in-Charge
Supply only of Mother board as per existing make of the UPS all as specified and directed by the Engr-in-Charge
Supply only of Sensing transformer as per existing make of the UPS all as specified and directed by the Engr-in-Charge
Supply only of Control card recifier and sensor as per existing make of the UPS all as specified and directed by the Engr-in-Charge
S&F in replacement cable joint kit for 1.1 KV grade heat shrink type and connecting accessories for 3.5/4 core 25 to 50 Sqmm XLPE aluminium conductor complete all as specified and as directed by Engr-in-Charge
All as per item No 147.00 above but cable of size 70 to 150 Sqmm complete all as specified and as directed by Engr-in-Charge
All as per item No 147.00 above but cable of size 185 to 240 Sqmm complete all as specified and as directed by Engr-in-Charge
All as per item No 147.00 above but cable of size 300 to 400 Sqmm complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of 500 Amps DO Fuse Cut Out all as specified and as directed by Engr-in-Charge
A. R. ELECTRICALS
M/s Pooja Enterprises
Blue chip consultancy Service
M/s Ramesh Lal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .