Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC OK | |
| 2 | L2₹14.5 L+₹80,549 (5.87%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹14.9 L+₹1.1 L (8.32%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹14.9 L+₹1.2 L (8.87%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹15.9 L+₹2.2 L (16.0%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
6 Jun 2020, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
REPAIR/REWIRING OF INTERNAL ELECTRIFICATION UNDER GE (WEST) PATHANKOT
2020_MES_328772_1
CWE/P-59/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Pathankot
class D and above and Category b i
9 documents required · 9 mandatory
₹500
Yes
GE (West) Pathankot
₹74,000
Yes
23 Jul 2020
26 Feb 2020
8 Jun 2020
26 Feb 2020
6 Jun 2020
11 Mar 2020
Amount
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators and sockets by unscrewing carefully from boards etc and making good disturbed surfaces of walls, as per existing finishes complete all as spd and directed.
M & L for point wiring for one light/one fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable with and including PVC concealed conduit heavy duty 20 mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked for switches and sockets , including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly, including cutting chiseling for concealed piping and making good disturbed surface to match with the existing surface complete all as specified and directed.Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green).
All as per srl item No 2 here-in-before but for 5 pin 5 amps socket outlet on independent board complete all as specified and directed.
All as per srl item No 2 here-in-before but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
M & L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable with in and including PVC concealed conduit heavy duty 20mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed.Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green).
S & F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S & F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S & F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed.
S & F ceiling rose 65 x 50mm three terminals complete all as specified and directed.
Supply and fixing in replacement of ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
S&F in replacement sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core complete all as required at site or directed.
S & F in replacement of CFLs with LED smart Lamp, B22 type ,14 watt,complete all as specified and directed.
S & F in replacement energy saving decorative LED box type with Led Rod 20 watt (4 Feet), 230 volts, 6500 K energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings. (Note power factor should not be less than 0.95) complete all as spd and directed.
M & L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller type AC ventilating fans, Single phase, 230 volts 300 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
M & L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller type AC ventilating fans, Single phase, 230 volts 250 mm sweep complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
M & L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing propeller type AC ventilating fans, Single phase, 230 volts 450 mm H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
S & F in replacement of existing unsv sheet metal enclosure with sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps 'C' curve complete all as specified and directed by Engr-in-charge.
S & F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
S & F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 6 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
S & F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
S & F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 2 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
S & F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
M & L MCB SP 240 volts any rating from 6 to 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed by Engr-in-charge.
M & L MCB SPN 240 volts any rating from 6 to 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed by Engr-in-charge.
Supply and laying in replacement of existing unserviceable/ brunt submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 6 sqmm drawing into and including concealed PVC rigid non metallic conduit of 20mm dia , 1.8 mm wall thickness and single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 6 sq mm as earth wire including cutting chases in brick wall, rendering in cement mortar 1:4 and making good the disturbed surfaces to match existing complete all as specified & directed. Note: Two runs of 6 Sqmm single core PVC insulated copper conductor cable(FRLS) and one run of 6 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of 20mm dia , 1.8 mm wall thickness wiil be measured as a one unit.
Supply and laying in replacement of existing unserviceable/ brunt submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 4 sqmm drawing into and including concealed PVC rigid non metallic conduit of 20mm dia , 1.8 mm wall thickness and single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 4 sq mm as earth wire including cutting chases in brick wall, rendering in cement mortar 1:4 and making good the disturbed surfaces to match existing complete all as specified & directed. Note: Two runs of 4 Sqmm single core PVC insulated copper conductor cable(FRLS) and one run of 4 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of 20mm dia , 1.8 mm wall thickness wiil be measured as a one unit.
S & F in replacement of old unsv sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a)MCCB four pole 100 Amp AC 415 volts 25 KA=01 NO as incoming and 12 nos. MCB SP 40 Amps, C series as outgoing (Note :- (i)The DB shall be VTPN (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (vi)MCCB's and MCB's should have a same make as of DB.
S & F bldg secuirty light fitting energy saving high efficiency LED street light fitting 25 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 32 mm dia bent to shape having length not less than 1.5 mtr fixing with clamp etc and making connections using cord flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-charge.
M & L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precast PCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion complete all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
Supply & Fixing in replacement of Socket outlet 2 in 1, 3 pin, 5A complete in existing circuit complete as directed by Engr-in-charge.
Supply & Fixing in replacement switch piano flush button single pole one way 5 Amp 230 volts in existing circuit as directed by Engr-in-charge.
Supply and Fixing in replacement of socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
Supply and Fixing in replacement of switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed.
Supplying & Fixing in replacement of Switch Bell push, flush type, 5 amp one way complete all as specified and directed by Engr-in-charge..
S&F in replacement of Buzzer Ding Dong, AC 230 Volts single Phase complete all as specified and directed by Engr-in-charge.
S & F in replacement lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings in existing circuit complete all as specified and directed.
Supply and Fixing in replacement LED Bulkhead fitting 10 watt all as specified and directed by Engr-in-charge.
S&F in replacement Hylum sheet 10 cm x 10 cm for fixing of switchs sockets including cutting for switch socket and fixing to existing sunken box with brass screw complete all as specified and directed by EIC
S&F in replacement Hylum sheet 10 cm x 15 cm for fixing of switchs sockets including cutting for switch socket and fixing to existing sunken box with brass screw complete all as specified and directed by EIC
S&F in replacement Hylum sheet 15 cm x 25 cm for fixing of switchs sockets including cutting for switch socket and fixing to existing sunken box with brass screw complete all as specified and directed by EIC
S&F in replacement Hylum sheet 20 cm x 25 cm for fixing of switchs sockets including cutting for switch socket and fixing to existing sunken box with brass screw complete all as specified and directed by EIC
Supply and fixing in replacement one single core 1.5 Sqmm nominal cross sectional area multistrand copper conductor cable PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed
Supply and fixing in replacement one single core 2.5 Sqmm nominal cross sectional area multistrand copper conductor cable PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed
S&F in replacement of old unsv wooden box with PVC switch box with sheet cover surface/ concealed 10x10x5 cm for switch socket and regulator including cutting for switch & regulator and fixing to existing sunken box with screw with one washer complete all as specified and directed by EIC
S&F in replacement of old unsv wooden box with PVC switch box with sheet cover surface/ concealed 15x10x5cm for switch socket and regulator including cutting for switch & regulator and fixing to existing sunken box with screw with one washer complete all as specified and directed by EIC
Supply and fixing MCBs single pole, neutral link (SPN) 63 Amps with 10 KA breaking capacity of 'C' series in distribution boardsc omplete all as specified and directed by Engr-in-charg.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
commercial traders
SATISH AND CO
M/S SINGH AND ASSOCIATES
satpal and brothers
M/S RUDHRAKSH TRADING CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .