Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.0 CrAccepted-AOC | ₹3.0 Cr | 1 | Accepted-AOC Lowest Bidder |
| 2 | 2₹3.2 Cr+₹18.9 L (6.30%)Rejected-Finance 28 PRAGATISHEEL COLONY NARMADA ROAD JABALPUR 482001 M P | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | ₹3.2 Cr+₹18.9 L (6.30%) | 2 | Rejected-Finance Other than lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Approved for opening of F-bid being two class below and also not eligible as U/E bidder |
Tender Value
₹3.0 Cr
EMD Value
₹3.8 L
Closing Date
29 Nov 2023, 6:00 pmClosed
CE (AF) Prayagraj
CE (AF) Prayagraj Bamrauli
CONSTRUCTION OF 80 BEDED GIRLS HOSTEL IN SANIK SCHOOL REWA UNDER GE (AF) BAMRAULI
2023_MES_590946_1
958811/E8
Open Tender
Civil Works
Lump-sum
455 days
Rewa
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) Bamrauli
₹3.8 L
Yes
19 Jan 2024
24 Apr 2023
6 Dec 2023
7 Sept 2023
29 Nov 2023
15 Nov 2023
Amount
SCHEDULE A PART I (BUILDING WORKS)
Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I .
Sch A Part II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II.
Sch A Part III (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV .
Sch A Part V (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for External Electrification as listed in Sch ‘A’ Part V.
Sch A Part VI (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI.
Sch A Part VII (AREA DRAINAGE)
Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII
Sch A Part VIII (ROAD/ PATH & CULVERT)
Lump sum price worked out by the contractor for Road/Path & Culvert as listed in Sch ‘A’ Part VIII
Sch A Part IX (SITE CLEARANCE AND EARTHWORK)
Lump sum price worked out by the contractor for Site clearance and Earthwork as listed in Sch ‘A’ Part IX
Sch A Part X (Miscellaneous Items of B/R and E/M)
S&F Wall/surface mounted type bulk Head LED light fitting complete with LED lamp 10 Watt, made of polycarbonate housing & enclosed with cover and integrate electronic driver complete with all accessories internally pre-wired and including connecting up with 3 core twisted flexible copper conductor cable complete all as specified and directed.
S&F 4 Module Gang Box including Modular socket outlet 20 Amps for AC, incl plug top 20 Amps, 240 Volts flush type white finish with Push ON/OFF button, 16 Amps 240 V and LED indicator (RED) incl concealed point wiring on wall/ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 V grade FRLSH PVC insulated unsheathed multistranded copper conductor following colour code in and including PVC conduit of medium grade with all the fittings such as bend, tees, junction boxes etc. including Modular metal flush box minimum 1.6mm thick of suitable size, modular white cover plate with frame 4 Module to accommodate all the accessories complete with internal connections, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm Single core 1100 V grade FRLSH PVC insulated unsheathed multistranded copper conductor (green) connected to common earth dolly and including cutting chases in walls/floors for concealed conduit complete all as specified and as directed.
S&F for down rod with anti suicide safe fan down rod of 260 mm length suitable for fixing in existing ceiling fan complete with nuts bolts, check nut and washers including making holes by drilling for bolts complete all as specified and directed. Note: Anti-Suicide safe down rod will be active if load on fan exceeded 20 kg, then down rod pipe open from middle and spring in pipe will be expanded for landing smoothly of person trying to commit suicide.
S&F for G.I. pipe medium grade bend to shape 1.5 m (32/40 mm dia as required at site) with two Nos clamps made out of 50x6 mm flat and two Nos bolt with nuts duly grouted in wall or fixing on wall complete all as specified and directed.
S&F of water heater storage type vertical type, puff insulation type of 50 Ltr capacity and 2000 Watts, BEE star rated-5 with glass line inner shell with Hot & Cold pipe, water connection pipe, electric connection and necessary fixing arrangements complete all as specified and directed.
S&F of sheet metal enclosure Double door, VTPN MCB DB 8 way, 415 V with 200 Amps rates Bus bar, IP-43 complete fixed properly in concealed position including internal , incoming /outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires complete all as specified and directed.
S&F of sheet metal enclosure Double door, VTPN MCB DB 6 way, 415 V with 200 Amps rates Bus bar, IP-43 complete fixed properly in concealed position including internal , incoming /outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires complete all as specified and directed.
S&F factory made epoxy powder coated distribution board SPN 8 Ways double door with acrylic top cover (IP-43 Protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed.
M & L Earthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly in ground (top edge of the plate not less than 1.5 metres below normal ground level) connected to GI wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layers of 150mm the PCC chamber using PCC (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bars @ 100mm C/C both ways with MS Handle 8 mm dia, plastering 15 mm thick CM (1:6) externally up to 150 mm below ground level, GI funnel with 20 mm dia medium grade GI Pipe for watering and wire mesh incl excavation and earthwork and disposal of surplus soil complete all as specified and shown on Electrical plate No. 3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Blg Nos and writing Test Results (in white) on blank painted M.S. Plate (size 300x300x3 mm) duly welded with angle iron of size 40x40x5 mm, 60 Cm long, fixed with the earth pit chamber by grouting complete including testing all as specified and directed. Note:- (i) GI wire and GI pipe medium grade, upto 7.5m shall be deemed to be included in the rates quoted (ii) Excavation and earthwork in any type of soil strata shall be deemed to be included in the rates quoted(iii) The Steel work, RCC , PCC work shall be deemed to be included in the rates quoted.
Supply, Installation, commissioning of water cooler fully stainless steel, electric driven (Single Phase), 230 V AC, having approx. storage capacity of 180 L and nominal cooling capacity of 150 Litres per hour including provision of PVC braided connection heavy duty 750 mm long with brass union both ends suitable for 15mm bore GI pipe and provision of necessary drain out water PVC pipe of suitable dia complete all as specified and directed.
Supply and fix Voltage stabilizer of capacity 3.0 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % complete all as specified and directed.
Supply and fix commercial Reverse Osmosis water purifier of output capacity of 50 Litres per hour with purification by RO+UV+UF and TDS controller complete all as specified and directed.
Cutting of existing main distribution GI Pipe of 40 mm dia and inserting tee 40x40x25 mm, etc. including necessary all connected accessories for tapping 25 mm connection completed all as specified and directed.
M & L for construction of valve pit brick masonary complete all as specified and directed as shown in TD drawing no. CEAF/TD/EM/01 sheet 1/1.
M&L for Well burnt Sub class 'B', Old Sized bricks laid dry, flat, over the cable abutting each other, length of brick equal to width of brick, complete all as specified and directed.
Supply and installation of 16 m high mast shaft fabricated from high tensile steel plates confirming to BS (EN)-10025 having minimum yield strength of 335 N/mm2 formed in polygonal shape and fillet welded and other components as per IS:2062 in two section suitable to sustain an assumed maximum reaction arising from wind speed (three second gust) as laid down by IS:875/1987 (Part-III) with raising/lowering system comprising head frame, luminary’s carriage in two halves of welded construction fabricated from durable round steel tube for aerodynamic effect and to act as conduit with holes in bottom side to take the wiring flexible cable suitable to install 08 Nos luminaries in symmetrical arrangement and aviation obstruction light 10 Watt installed on top, double drum winch self lubricating by means of oil bath, worm gear driven of ratio 53:1 type tested, stainless steel wire ropes in grade 304 or 316 in flexible 7/19 construction (central core of same material), trailing cable connector, integral three phase power tools for the operation of which incorporate mechanical torque limiter for safety of equipment suitable arrangements to couple the integral power tools and support the external power tool, provision to lower the luminary’s carriage manually by handle, junction box, provision to fix the hot dip galvanized lightening finial with two number 12 mm dia galavanized bolt with nut and washers are fixed on door stiffener to terminate the earth strip from earth pit, Hot dip galvanized high tensile foundation bolts with nuts, washers, anchor plate and common template for precisely setting the bolts with outdoor type stand, mounted feeder pillar with 63 A TPN MCB incomer, Automatic nature time switch, 45 A TP contactors and raise/lower push button, incoming 10 Sqmm and out going 10 & 2.5 Sqmm terminals,wiring (wiring with 2.5 Sqmm copper conductor
PVC insulated FRLS cable from Junction Box to individual luminaire & MCB in base compartment are included and are a part of installation), including construction of shallow foundation with M-20 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/Sqm at 2 m depth with all materials and labour including erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated sheathed suitable core flexible cable of copper conductor of suitable size, lugs, MCB etc. including provision of 4 Nos GI Pipe/ Plate earthing (02 Nos for mast and 02 Nos for electrical panel) with 2.5 m long 40 mm dia perforated GI Pipe including connection to high mast earth terminal with 25x3 mm GI Flat strip with all materials and labour including installation of the electrical feeder pillar by grouting the stand in concrete pedestal complete all as specified and directed. Note: 1. Rate quoted shall be deemed to include the excavation of earth and RCC foundation as per OEM’s design and drawing complete. 2. Flood light fittings 08 Nos and LED aviation obstruction light 10 Watt -01 No shall be paid separately under External Electrification Schedule in the relevant items.
Boring of holes under road/pavement/hard standing by trenches technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 MPa working pressure complete all as specified and directed.
S&F for Flood light fitting 150 Watt, asymmetric, individual LED’s with secondary lens optics with IP-66 ingress protection, having pressure dia cast aluminum housing with heat resistant toughened glass, 4 KV inbuilt and 10 KV external surge protection efficiency 120 Lm/W, internal wiring with suitable size 3 core copper conductor cable for mounted on GI bracket on high mast (16 m height) complete all as specified and directed.
S&F for LED aviation obstruction light 10 Watt to be installed on top of high mast pole, IP-66 having pressure dia cast aluminum housing with heat resistant toughened glass, individual LED’s with secondary lens optics complete, making connections with suitable size 3 core copper conductor cable complete all as specified and directed.
M & L Earthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly in ground (top edge of the plate not less than 1.5 metres below normal ground level) connected to GI strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 40 mm GI tubing medium grade and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layers of 150mm the PCC chamber using PCC (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 8mm dia TMT bars @ 100mm C/C both ways with MS Handle 8 mm dia, plastering 15 mm thick CM (1:6) externally up to 150 mm below ground level, GI funnel with 20 mm dia medium grade GI Pipe for watering and wire mesh incl excavation and earthwork and disposal of surplus soil complete all as specified and shown on Electrical plate No. 3 of SSR Part-I (2009) and connected to earth test point incl testing and marking Blg Nos and writing Test Results (in white) on blank painted M.S. Plate (size 300x300x3 mm) duly welded with angle iron of size 40x40x5 mm, 60 Cm long, fixed with the earth pit chamber by grouting complete including testing all as specified and directed. Note:- (i) GI strip and GI pipe medium grade, upto 7.5m shall be deemed to be included in the rates quoted (ii) Excavation and earthwork in any type of soil strata shall be deemed to be included in the rates quoted (iii) The Steel work, RCC , PCC work shall be deemed to be included in the rates quoted.
M&L for RCC Septic tank 100 Users designed to carry sewage and sullage water, excavation in any type of soil complete all as specified and shown on TD drg no. TD/750 sheet 1/2 & 2/2.
M&L for Soakage wells excavation in any type of soil complete all as specified and shown on TD drg no. TD/576 sheet 1/2 & 2/2.
Tiki Water proofing Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .