Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹19.4 L
EMD Value
₹38,780
Closing Date
30 Oct 2026, 11:00 am
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Published by the portal on this tender, for queries and grievance redressal.
SITC of 2 TR Split and cassette type AC unit at TE Building
10012446
GEM/2026/B/8141117
Two Packet Bid
SITC of 2 TR Cassette type AC
Bhopal, Madhya Pradesh
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
3 yrs
₹6 L
80%
The Account officer (A & B) O/o CGMT Bhopal (M.P.), Account officer (A & B) O/o CGMT Bhopal (M.P.)
₹38,780
9 Oct 2026
9 Oct 2026
31 Oct 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | SITC of 2 TR wall mounted AC | Supplying of 2 TR ( Rated Cooling Capacity Not Less than 6 kW) inverter type 5 Star rated wall mounted split Air-Conditioner unit as per BEE star rating minimum (ISEER) of 5 with temperature control thermistor remote control unit filters rotary / scroll type compressor copper tubes for both indoor and outdoor unit and Installation Testing & Commissioning of the 2 TR Inverter type Split AC unit at a specified location by mounting/fitting Indoor and Outdoor units at their respective locations laying and fixing of both liquid and hot gas lines inter connecting wiring for both indoor outdoor units up to 3 Metres length and interconnecting the indoor unit and outdoor unit with refrigerant line insulating the refrigerant pipe with expandable polyethylene Foam tubing unit Leak testing entire system charging Refrigerant gas in the unit making power supply connections from the power point etc complete as required
Providing the following up to the length of 3 Meter etc as required
(1) Gas & Liquid refrigerant piping each and (2) suitable connecting electrical cable between indoor and outdoor unit (Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier or similar superior Make) | 4 | Nos | Vinod Shringi 462024,O/o Chief Engineer (Electrical)BSNLMIG-11-14/4-B Sector Old Saket Nagar | 30 |
| 2 | Supply fixing Copper Piping for SAC | Supplying and fixing extra copper pipe line beyond 3 meter suitable for 2 TR Split AC for gas line and for liquid line of suitable dia to match with the pipeline of the split type unit supplied along with suitable size rubber foam/insulation as per manufacturer recommendation on surface of the wall / cable tray i/c necessary flare nuts suitably brazing with the existing pipe clamping making holes in walls same etc as per site requirement (Note The rate of per meter length included cost of both gas & liquid line insulation accessories additional refrigerant etc) | 10 | Mtrs | Vinod Shringi 462024,O/o Chief Engineer (Electrical)BSNLMIG-11-14/4-B Sector Old Saket Nagar | 30 |
| 3 | SITC of 2 TR Cassette type AC | Supplying of 2 TR ( Rated Cooling Capacity Not Less than 7 kW) inverter type 5 Star rated four way cassette type Air Conditioner unit suitable for false celling with temperature control thermistor remote control unit filters rotary / scroll type compressor copper tubes for both indoor and outdoor unit and Installation Testing & Commissioning of the 2 TR cassette type Air-Conditioner unit at a specified location by mounting/fitting Indoor and Outdoor units at their respective locations interconnecting the indoor unit and outdoor unit with refrigerant line Leak testing entire system charging Refrigerant gas in the unit making power supply connections from the power point etc complete as required
( Make Daikin / Blue Star / Hitachi / Voltas / O General / Mitsubishi / Carrier or similar superior Make) | 11 | Nos | Vinod Shringi 462024,O/o Chief Engineer (Electrical)BSNLMIG-11-14/4-B Sector Old Saket Nagar | 30 |
| 4 | Supply fixing of Copper Piping | Supplying and fixing copper pipe line for suitable for 2 TR Cassette AC gas line and for liquid line of suitable dia along with suitable size rubber foam/insulation as per manufacturer recommendation on surface of the wall / cable tray i/c necessary flare nuts suitably brazing with the existing pipe clamping making holes in walls same etc as per site requirement
(Note The rate of per meter length included cost of both gas & liquid line insulation accessories additional refrigerant etc) | 150 | Mtrs | Vinod Shringi 462024,O/o Chief Engineer (Electrical)BSNLMIG-11-14/4-B Sector Old Saket Nagar | 30 |
| 5 | Supply laying of 3x4 Sqmm copper cable | Supplying and laying 3 core 4 sqmm PVC insulated and PVC sheathed flexible copper cable along with refrigerant pipe or along with existing conduit / cable tray i/c binding with plastic tags for extending supply from existing industrial socket to indoor unit etc as required (Make ISI Make) | 150 | Mtrs | Vinod Shringi 462024,O/o Chief Engineer (Electrical)BSNLMIG-11-14/4-B Sector Old Saket Nagar | 30 |
| 6 | Supply fixing MS Stand | Supplying & fixing of Powder Coated MS frame stand comprising of Two numbers bracket made of heavy duty MS Sheet to accommodate the Condenser (Outdoor) unit for fixing on the wall / Floor with suitable diameter and length of Anchor fast bolts and making good damages etc as per site requirement | 15 | Nos | Vinod Shringi 462024,O/o Chief Engineer (Electrical)BSNLMIG-11-14/4-B Sector Old Saket Nagar | 30 |
| 7 | PVC braided drain pipe | Supplying and Fixing of heavy duty PVC Braided pipe of suitable size for 2 TR Split / Cassette Air Conditioner Unit with accessories for drain water connection etc complete as required | 100 | Mtrs | Vinod Shringi 462024,O/o Chief Engineer (Electrical)BSNLMIG-11-14/4-B Sector Old Saket Nagar | 30 |
| 8 | M S Cable Tray 150 mm | Supplying and installing of 150 mm width X 50 mm depth X 1 decimal 6 mm thickness size of perforated painted with powder coating M S cable trays with perforation not more than 17 decimal 5 percentage in convenient sections joined with connectors suspended from the ceiling with M S suspenders including bolts & nuts painting suspenders etc as required | 20 | Mtrs | Vinod Shringi 462024,O/o Chief Engineer (Electrical)BSNLMIG-11-14/4-B Sector Old Saket Nagar | 30 |
| 9 | M S Cable Tray 300 mm | Supplying and installing of 300 mm width X 50 mm depth X 1 decimal 6 mm thickness size of perforated painted with powder coating M S cable trays with perforation not more than 17 decimal 5% in convenient sections joined with connectors suspended from the ceiling with M S suspenders including bolts & nuts painting suspenders etc as required | 30 | Mtrs | Vinod Shringi 462024,O/o Chief Engineer (Electrical)BSNLMIG-11-14/4-B Sector Old Saket Nagar | 30 |
| 10 | MS Angle Iron | Providing & Fixing of MS Angle Iron / MS Flat for fabricating of outdoor unit stand i/c cutting welding painting and grouting fixing in the ground/floor/wall/recess etc complete as
reqd | 50 | KG | Vinod Shringi 462024,O/o Chief Engineer (Electrical)BSNLMIG-11-14/4-B Sector Old Saket Nagar | 30 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_10012446.pdf
GEM_BID • 0.14 MB
nitnocsac_2026-10-09-16-50-59_b5bb9016af6fb2f1b44bb692b2465f9e.pdf
BOQ • 2.77 MB
boqnocbpl_2026-10-09-16-50-59_2829485bc6ba585b3b2ef031aad5fca1.csv
BOQ • 0.01 MB
NITNOCSAC_c22389ce-c993-4c9b-acb81791546794508_SDEEPMM2.pdf
GEM_OTHER • 2.77 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .