Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical NON RESPONSIVE |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
13 Nov 2019, 6:00 pmClosed
ER. MUJIB AHMED TAK
O/o DEPUTY DIRECTOR TOURISM M AND W JAMMU
Internal and External Electrification of TRC at Lal Drahman Doda District
2019_Tourm_85144_9
e-NIT No. 76 2019-20 Dated 02-11-2019
Open Tender
Electrical Works
Item Rate
30 days
LAL DRAMAN DODA
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
DEPUTY DIRECTOR TOURISM M AND W JAMMU
₹19,600
Yes
11 Feb 2020
5 Nov 2019
14 Nov 2019
5 Nov 2019
13 Nov 2019
5 Nov 2019
Amount
Wiring for Light Point /Fan Point/Exhaust Fan Point/ Call Bell/ Point with 1.5 Sq.mm FRPVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI Box and earthing the point with 1.5 Sq.mm FRPVC, insulated copper conductor single core cable etc. as required including cutting the wall and making good the same in case of recessed conduit as per site requirement
Group A
Group B
Group C
Wiring for circuit /Submain wiring along with earth wire with the folloiwng sizes of FRPVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required
2 x 2.5 Sq.mm +1 x 2.5 Sq.mm earth wire
2 x 4 Sq.mm +1 x 4 Sq.mm earth wire
2 x 10 Sq.mm +1 x 10 Sq.mm earth wire
Supply and fixing folloiwng sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per site requirement (Anchor, Havells, Polycab)
Supply and fixing folloiwng modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required (Anchor, Havells, Polycab)
5/6 Amp Switch
15/16 Amp Switch
3 Pin 5/6 Amp socket
6 Pin 15/16 Amp Socket
Supplying and fixing stepped type electronic fan regulator on the nexisting modular plate switch box including connections but excluding modular plate etc as required (Anchor, Havells, Polycab)
Supply and fixing following modular blanking plate on the existing modular plate and switch box excluding modular plate as required (Anchor, Havells, Polycab)
Supply and fixing following size/modular GI Box along with modular base & cover plate for modular switches in recess etc as required (Anchor, Havells, Polycab)
2 modular (75mm x 75mm)
3 modular (100mm x 75mm)
4 modular (125mm x 75mm)
6 modular (200mm x 75mm)
8 modular (125mm x 125mm)
12 modular (200mm x 150mm)
Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required (Anchor, Havells, Polycab)
Supply and fixing brass batten angle holder including connection etc as required (Anchor, Havells, Polycab)
Supply and fixing call bell/buzzer suitable for single phae 230 Volt complete as required (Anchor, Havells, Polycab)
Numbering of ceiling fan/exhaust fan/concealed light fitting etc as required (Anchor, Havells, Polycab)
Supply and fixing way, single pole and neutral sheet steel, MCB doistribution board, 240 Volt, on surface recess complete with tinned copper Bus bar neutral Bus Bar earth bar dinbar, interconnection, powder painted including earthing etc as required (Anchor, Havells, Polycab)
2+8 way, double door
2+12 way, double Door
Supply and fixing 5 Amp to 32 Amp rating, 240/415 Volt "c" curve, miniature circuit breakes suitable for induitire load of following poles in the existing MCB DB complete with connection, testing and commissioning etc (Anchor, Havells, Polycab)
Single Pole
Single Pole and neutral
Supply and fixing following rating double pole (Single pole and neutral, 240 volt with connection and testing (Anchor, Havells, Polycab)
Providing and fixing danger H.T plate of 200 mm x 150 mm, made of mild stell, at least 2mm thick and vitreus enamelled white on both sides and with insoridation in single red colour on front side as required
Earthing with copper earth plate of 600mm x 600mmx3mm thick including accessories and providing mansory enclouse with cover plate having locking arrangement and watering pipe of 207 metre long etc with charcoal/coke and salt as required
Supply and laying 25mm x 5mm copper at 0.50 metre below ground as strip earth electrode including connection/terminating with nut bolt, sprit washer etc as required
SITC of recessed/surface mounted circular/Square type led based light, as per site requirement of 12 watt Make Philips, Jaquar, Havells
SITC of recessed/surface mounted circular/Square type led based light, as per site requirement of 06 watt Make Philips, Jaquar, Havells
SITC of 4 feet Led batten of 20 watt (Philips, Jaquar, Havells)
SITC of 02 feet Led batten of 10 watt (Philips, Jaquar, Havells)
SITC of 2 feet x 2 feet Recessed/surface mounted Led Panel 36 Watt (Philips, Jaquar, Havells)
SITC of Flood Light of 50 Watt with high pressure die cast housing with lens (IP65 Protection)(Philips, Jaquar, Havells)
Supply, installation, testing and commissining of ceiling fan of 1200mm sweep (Like USHA, Havells, Bajaj)
Supply, installation, testing and commissining of iron tupe exhaust fan of 450mm sweep (Like USHA, Havells, Bajaj)
Supply and fixng of 09 watt Led bulb (Syska, Havells, Jaquar)
SITC of electric based gyzers of 25 liter 240 volt, 15 Amp single phase (Bajaj,Orient, Havells)
SITC of PVC insulated Aluminium based Cable 10 Sq.mm
Providing fixing commissioning of solar street light with Li-ion (Lithiumion) Battery with 05 years warranty consisting of PV module 100 WP Li-ion Battery 11.5/40 Ah, charge controler 11.5/10 Amp, LED Panel of 24 watt, Housing Mounting Pole of 80 mm dia, 6 Mtr High other Accssories (No separate Box for Battery) Panel & Led light must be following make like Sukam, Havell, HBL. Pole must be of ISI mark like Jindal, Oswal,Parkash Surya
Supply, installation, testing and commissioning of following accessories
MCCB 100 Amp 16 KA
TPN 63 Amp (Anchor, Havell, Kei)
Automatic change over switch for DG/Invertor supply 63 Amp (Anchor, Havlles Kei)
Supply anf fixing of Batten, PVC, ISI mark
SITC of wall mounted fan 400 mm (Anchor, Usha, Havells, Crompton)
Abdul Gani Tantray and Co
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .