Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L1 | Accepted-AOC QUOTED RATE LOWEST AND REASONABLE. | |
| 2 | L2₹14.7 L+₹14,674.50 (1.01%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L2 | Rejected-Finance QUOTED RATE NOT LOWEST | |
| 3 | L3₹15.9 L+₹1.3 L (8.77%)Rejected-Finance ABANI APARTMENT 1ST FLOOR 6 2 TALBAGAN ROAD WEST PO NONACHANDANPUKUR BARRACKPORE KOLKATA 700 122 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700122 | L3 | Rejected-Finance QUOTED RATE NOT LOWEST | |
| 4 | L4₹16.5 L+₹1.9 L (12.8%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L4 | Rejected-Finance QUOTED RATE NOT LOWEST | |
| 5 | L5₹17.3 L+₹2.8 L (18.9%)Rejected-Finance | L5 | Rejected-Finance QUOTED RATE NOT LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Mar 2024, 6:00 pmClosed
CWE KOLKATA
Headquarter Commander Works Engineers Military Engineer Services No1 National Library Avenue Alipore Kolkata700 027
REPAIR REPLACEMENT OF MISC WORKS FOR LIFTS FIRE FIGHTING AND CONNECTED WORKS AT AF CAMP GE CENTRAL KOLKATA
2024_MES_640121_1
8290/E-35/23-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(C) KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE CENTRAL KOLKATA
₹40,000
23 Apr 2024
1 Feb 2024
8 Mar 2024
1 Feb 2024
1 Mar 2024
16 Feb 2024
2 Feb 2024 - 9 Feb 2024
Amount
Excavation in trenches not exc 1.5 metre wide and not exc. 1.5m in depth and getting out as in soft / loose soil for foundation of pole, laying of electric cables etc complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well rammming in layers not exc 25cm thick complete all as specified in soft / loose soil and as directed by the Engr-in-Charge
Removing excavated materiasl not exc 50 mtr and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and direced by the Engr-in-Charge
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and direced by the Engr-in-Charge
Laying only in trenches old serviceable bricks obtained from taking out old unserviceable XLPE cable, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by Engr-in-Charge
M&L for cutting existing road / path etc for taking out cable and protection pipe and making good the disturbed surfaces with PCC 1:3:6 type C2 (using 40mm graded stone aggregate) of suitable depth complete all as directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation base of poles and other similar locations including demolition of old PCC / broken PCC complete all as specified and directed
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) with and including all necessary form work and demoltion of old PCC/broken PCC complete all as specified and directed
M&L for PCC (1:2:4) type B-1(using 20mm graded stone aggregate) as in coping of pole/struts and other similar location etc with and including all necessary form work and 10mm thick plastering in CM 1: 4 including demoltion of old PCC/broken PCC complete all as specified & directed.
Taking out unserviceable UG cables of any type and any sizes from trenches etc and removing from the site of work complete all as specified and directed. Note:- (i) Old serviceable bricks obtained from cable protection shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of BOQ / Sch 'A'.
Supply and laying XLPE insulated , armoured, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 95 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and as directed by the Engr-in-Charge.
Supply and laying XLPE insulated , armoured, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 185 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and as directed by the Engr-in-Charge.
M& L for cable jointing kit for 1100 volt grade cable for straight through heat shrink type joint complete with jointing materials and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm 3.5 core size including testing all as specified and directed.
S&F of PVC cable terminal boxes, outdoor type of size 155mm x210mm x92mm with MCB SP 6 to 32 Amps including all necessary fittings and connection and taking down old unserviceable one complete all as directed by Enginner-in-Charge. Make:- Hansel Model No. KF 1616G or equivalent product of Sintex/ Universal / Denson.
S&F of PVC cable terminal boxes, outdoor type of size 93mm x93mm x62mm including fixing with clamp and taking down old unserviceable one complete all as directed by Enginner-in-Charge. Make:- Hansel Model No. KF 0200B or equivalent product of Sintex/ Universal / Denson.
S&F of Timer switch of analogue type for street light fittings, module 1 including taking down old unserviceable one complete all as specified and as directed. Make:- L&T Cat part No. AUTS01ANA00 or equivalent product of Schneider / ABB / SIEMENS
S&F Modular contactor 40A-2 NO, 3 module, including taking down old U/S one complete all as specified and directed Make:- L&T cat No AUMC2004003 or equivalent product of Schneider / Siemens
S&F of LED decorative post top lantern, 35/40 Watt capacity for energy efficient conservation upto 50% and with eco friendly lighting system and all accessories and necessary connection including taking down old unserviceable one complete all as specified and as directed. Make:- Havells cat part No. RUBYPT35WLED830PSYMTOPC or equivalent product of Bajaj / Philips / Crompton
Supply and drawn into the steel tubular pole, by drilling holes just above the junction box and another holes near street light brackets PVC insulated stranded copper electric cable of size 2.5 sqmm 2 core (flexible) & all necessary connetions with junction box and street light fittings, complete all as specified and as directed. MAKE:Universal cables/asian cables/CCI
S&F of Landscape lightning 10 watt ( LED bollard) of IP 65 rated inverted pyramid type with soft 360 deg light distribution with necessary PCC base complete all as specified and directed as in repair. Make:- Crompton Cat No LBLSN-10-CDL or equivalent product of Bajaj / Havells / Philips.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (using 20mm graded stone aggregate), 50 mm thick pre-cast RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal of soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed including taking down / up old unserviceable earthing set.
S&F of LED security light luminaries of 45W LED housing in high pressure die cast aluminium with heat sink with electrochemically brightened and anodized aluminium reflector, heat resistant toughened glass including necessary fixing arrangement with GI Bracket of 32-40mm dia suitable for LED fittings duly grouted in walls including taking down the defective bldg security lights of any capacity complete all as specified and directed Make : Crompton greaves Cat No LSTP-45-CDL or equivalent product of Bajaj/ Philips
S&F of LED Street light luminaries of 90W LED aerodynamically designed with excellent thermal management inbuilt tilt angle arrangement with IP66 protection including taking down the defective bldg security lights of any capacity complete all as specified and directed Make : Crompton LSTN-90-CDL-A or equivalent product of Bajaj / Philips
S&F of MCCB 4 pole 160A, 36KA, 415V thermal and magnetic adjustable type (ICS= 100% of ICU) including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one complete all as specified and directed. Make:- Havells / Legrand / L&T
S&F of MCCB 4 pole 100A, 25KA, 415V thermal and magnetic adjustable type (ICS= 100% of ICU) including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one Make:-Havells Cat Part No. IHLGHF0100 or equivalent product of Legrand / L&T
S&F of MCCB 4 pole 63A, 25KA, 415V thermal and magnetic adjustable type (ICS = 100% of ICU) including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection complete all as directed including taking down old one. Make:- Havells / Legrand / L&T
M & L for steel tubular swaged pole 9 mtr long complete with MS base plate, finial taper plug, nut, bolts, screws as specified type 410 SP-31 as per relevant IS specifiecation including two coats of aluminimum paint over a coat of red oxide primer and two coats of black paint to bottom of pole with yellow strip around complete all as directed by Engineer-in-Charge.
M&L for preparation of old painted surface of existing steel tubular sewaged pole 9 mtr long, cross arms, clamps GI street light bracket etc and applying two coat of aluminium paint including writing pole number & bottom of pole painted with black paint with yellow strip around between the juction of aluminium paint and black paint complete as directed and specified.
S&F of LED flood light luminaries of 80W with made in pressure diecast housing and highoutput emitter LED and IP66 protection including taking down the defective flood lights of any capacity Make : Crompton cat no LFL-80-CDL/60 or equivalent product of Bajaj / Philips
M&L for Danger notice plate of 1.6mm thick for LT 20x15 cm in size, mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal redcolour and fixed with Ms clamp, bolts and nuts comlpete all as specified & directed
S&F of Changeover Switch, open execution type, four pole, 200 Amps, 415 V complete all as specified and as directed. Make:- Havells Cat Part No.IHCNFO0200 or equivalent product of L&T / Schneider
M&L for 32x6mm galvanised iron strip burried in ground/fixed on wall, roof with saddles and fixing screws etc., for roof conductors and down conductors above ground complete all as specified and as directed.
M&L for Air termination,single pointed Al rod 12mm dia and 300mm long complete all as specified and as directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm,drilled and screwed including 3 nos 8 mm dia 25mm long hex head screw complete all as specified and as directed.
Taking down old aluminium strip/ GI strip of any size and refixing the same with new saddles ,clamps,screws etc to its original position complete all as directed
Taking down defective existng LED street light /LED security light fitting of any type and any capacity from any height of pole / any place and refitted the same in position after necesssary fault finding / repair /replacement the defective components and making connection with copper wire 1.5 sqmm and PVC connector block and testing complete all as directed Note : LED driver shall be measured and paid separately as "supply only".
Supply only constant current LED driver operating voltage 180v-270v AC 50/60 HZ out put voltage 36V DC/2.8 Amp power factor 0.95 Make : Bajaj cat No BGD36 240 5Y or equivalent product of Philips/CG
Supply only constant current LED driver operating voltage 180v-270v AC 50/60 HZ out put voltage 36V DC/2.8 Amp power factor 0.95 Make : Bajaj ca No BGD70 065 5Y or equivalent product of Philips/CG
S&F of power factor correction MPP standard duty capacitor bank box type 440 V of capacity 20KVAR and making electric connection and testing including taking down oldunserviceable capacotor complete all as specified & directed Make : L&T CAT NO SERIES-LTBCD or equivalent product of Schnider/ABB
S&F of MCB TP 63 Amps 415 volts including taking down old unserviceable relay one all as specified and directed Make : L&Tor equivalent product of Schnider/ABB
S&F of MCB TP 32 Amps 415 volts including taking down old unserviceable one all as specified and directed Make : L&Tor equivalent product of Schnider/ABB
S&F of LED indicating lamp RYB suitable for electric panels including making connection and taking down old unserviceable one all as specified & directed
S&F of on/off switch push button with element type suitable for APFC panels including taking down old unserviceable one all as specified and directed Make: L&T/ABB/Schnider
M&L for flexible PVC pipe of size 25mm suitable for electric connection complete all as specified and directed.
Cutting the existing road/path etc for taking up of cable including protection pipe any size and any length and making good the disturbed road/path with PCC 1:4:8 type D1 (using 20mm graded stone aggregate) average thickness of 25 mm, after laying the cable complete all as specified and directed
S&F of decorative street light pole asthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish of length 6 mtr including taking down old pole complete all as specified and directed Make:- Havells cat No 6MPE or equivalent product of Bajaj / Philips
S&F of junction pole box made of high quality thermoplastic polycarbonate (shock proof ,rust free,corrosion free,acid and chemical resistant,fire retardant) having high impact strength, of IK 9, made of halogen and silica free recyclable material IP66/67 degree of protection, UV resistant, having high graded internally embedded gasket made of poly urethane should withstand glow wire test at 960 degree centigrade, should be flame retradant and self extingushing with switch gear assemblies as per IEC-439-1 the junction box should have 4 power terminal of 25 Sqmm and earth terminal along with a SP MCB of 6 Amp fitted in it the dimension of box shall be 205x255x112in mm (LxHxD) Make: Hensel KF 2500 G make of MCB L&T. and fixing to tubular /PCC pole using MS flat of size 25x3mm with suitable nuts and bolds after taking down old unserviceable one complete all as specified and directed .
M&L for Glow sign board along with pipe bracket with accessories including 0.20mm thick white rubber coated vinyl or synthetic vinyl sheet painted with scotch / computer inject printing with outdoor ink and with 300x 720 DPI and also 140 DPI laminated with average 0.15mm high quality weather protect with chemical and including 1.5mm thick poly carbonated PVC milky / transparent sheet drawing art work computer designing including 22 SWG sheet frame work arrangement for fixing LED tube light fittings 18/20 Watt 1no per sqm with necessary connection with 1.5 Sqmm single core copper conductor cable and 50mm dia Light grade pipe 3RM x 2 Nos duly grouted 0.80m deep in PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) including all necessary fixing arrangement & tools and plants complete all as directed by Engineer-in-Charge including taking down old unserviceable glow sign board complete all as specified & directed .
Maintenance of 11 KV VCB by track out the breaker and checking , cleaning all the parts of the breaker and cleaning the breaker with the help of vaccum cleaner/ air blower as required and checking all electrical and mechanical connection/parts of VCB and tightening the connections and testing all parts all as required .testing the functions of all electrical components and mechanical components as per the direction of Enginner-in-charge, unit cost includes the replacement of all bolts, nuts & washers, panel door glass, hinges etc where ever directed with new one as per existing size, cleaning the entire VCB panel enclosure with all parts inside including bushings and out side of VCB with the help of air blower, testing the VCB with all protection relays,meters,triping circuit,closing circuits, anti pumping relay,DC power system, for confirming the poper functioning of all circuits , all meters, relays are satisfactory after rack in the breaker.for any make of VCB complete all as specified & directed .
Supply and filling of transformer oil as per IS 335/1993 for replacement/topping up of transformer oil upto optimum level of the transformer & HT link switch(VLE/Tee Off) having die electric strength not less than 60 KV complete all as specified and directed.
De-hydration and filtration of transformer oil direct from transformer / VLE / Tee off switch at site with help of transformer filtration and dehydration machine of capacity not less than 100 LPH of reputed company and testing of die electric strength before and after dehydration and filteration work complete all as directed and specified. Note : (i) The die electric strength of the oil after dehyderation shall be 45 KV with 2.5mm gap between testing electrodes. (ii) The contractor shall arrange the equipments like transformer oil tester, required length of hose, clamps and all accessories/trools required to carry out the dehyderation and filteration work at site. (iii) Transformer oil required for topping up shall be measured and paid separately.
S&F of ARD panel casing of battery via 6 Nos of 12V, 17 AH maintenance free dry cell batteris after taking out old unserviceable one complete all as spcified and as directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm including taking out / removing damaged end terminal joints and making connection to transformer / link switch etc. and testing complete on full load, all as specified and as directed. Make: Denson / Sintex / M Seal.
S&F of door safety infra red sensor/detector consisting of the emitter and receiver, power supply box, flexible cables, relay output 1A, 230V AC/2A, 30VDC, operating temperature 20 degree to 85 degree centigrade, 154 beams, response time 61 ms, highest beam 1860mm, lowest beam 25mm and protection distance 0-5mtr including necessary accessories for fixing sensor complete including dismantling of old existing one all as specified and directed by Engr-in-Charge Make:- TL Jones/Memco/ADCO/TVS cherry
Dismantaling and taking out old serviceable/serviceable existing GI tubing 50 mm bore including all connections and fittings all as directed.
Dismantaling and taking out old serviceable/serviceable existing GI tubing 40 mm bore including all connections and fittings all as directed.
Dismantaling and taking out old serviceable/serviceable existing GI tubing 25 mm bore including all connections and fittings all as directed.
M&L for relaying and refixing of old serviceable GI tubing 50 mm bore including all new connections and fittings all as directed.
M&L for relaying and refixing of old serviceable GI tubing 40 mm bore including all new connections and fittings all as directed.
M&L for relaying and refixing of old serviceable GI tubing 25 mm bore including all new connections and fittings all as directed.
Supplying & Laying GI tubing 50 mm bore of tube medium grade with new all fittings(ISI Approved Make), bend to shape as required on ground including jointing materials (such as white lead,fine yarn as required) laid in trenches, testing after completion for leakage complete all as specified and directed.
Supplying & Laying GI tubing 40 mm bore of tube medium grade with new all fittings(ISI Approved Make), bend to shape as required on ground including jointing materials (such as white lead,fine yarn as required) laid in trenches, testing after completion for leakage complete all as specified and directed.
Supplying & Laying GI tubing 25 mm bore of tube medium grade with new all fittings(ISI Approved Make), bend to shape as required on ground including jointing materials (such as white lead,fine yarn as required) laid in trenches, testing after completion for leakage complete all as specified and directed.
Taking out gate valves of any size and all connections and fittings all as directed.
S&F of gunmetal globe or gate valve for 50mm bore pipe, with iron wheel head screwed both end complete all as specified and directed. Make : Zoloto /Leader /Kirloskar.
S&F of gunmetal globe or gate valve for 40mm bore pipe, with iron wheel head screwed both end complete all as specified and directed. Make : Zoloto /Leader /Kirloskar.
S&F of gunmetal globe or gate valve for 25mm bore pipe, with iron wheel head screwed both end complete all as specified and directed. Make : Zoloto /Leader /Kirloskar.
Taking out stop valves of any size and all connections and fittings all as directed.
S&F of stop valve cast copper alloy,screwed down,high pressure,with crutch or butterfly handle, for 50mm bore pipe, with iron wheel head screwed both end complete all as specified and directed.
S&F of stop valve cast copper alloy,screwed down,high pressure,with crutch or butterfly handle, for 25mm bore pipe, with iron wheel head screwed both end complete all as specified and directed.
S&F of stop valve cast copper alloy,screwed down,high pressure,with crutch or butterfly handle, for 25mm bore pipe, with iron wheel head screwed both end complete all as specified and directed.
M&L for M S works for fabrication of clamps of required size for support of water pipe lines including bolts, nuts and washer complete all as specified and directed. .
M&L for valve pit chamber of size 900x900x1500mm including MS sheet cover 6mm thick with angle iron frame and locking arrangement as per site requirmrnt all as specified and directed (Ref TD Drg No: CZ/TD/531 dated 14.10.1996) Note:- Unit rate shall be deemed inclusive all necessary earthwork, concrete work, brick work and MS fabrication work etc
De-watering of existing RCC UG water tank size 25000 Gln capacity at UG tank with wire brush,cloth ,bleaching powder,removing all dirt scale from tank and from mouths of circulating pipes etc through drain pipe or by manually including writing with white paint in tank wall as "TANK CLEANED ON" with date ,month and year with a minimum 10 CM height capital lettrs/numbers and conducting all connections (if any) after cleaning and testing at different multi-storeyed buildings at AF camp complete all as specified and directed by Engineer-In-Charge.(a) To drain out the water by using exit valve or our own high capacity dewatering system. (b) Cleaning all the algae formation inside the tank by using TERBAC G5 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks.(c) Fresh water cleaning by high speed jet pump (d) first bacteria screening is desertification by using TERBAC G5 a govt laboratory certified branded halogen compound. (e) Cleaning of the floor of the water tank by industrial vacuum cleaner. (f) The second bacteria screening and sterlizing method by using ultra violet ray with in the tank and kills all suspended bacteria. (g) Cleaning the third bacteria screening and sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agent TERBAC G65.
Carrying out water quality test reports by collecting of water sample for testing form main water receiving of UG sump at AFCB in special sterilized container and submitting to Govt. approved test laboratory as per IS 10500 (quality of water suitable for human consumption or not is to be menttioned in microbiological water test report). Note : Testing shall be carried out in a Govt approved testing centre all as directed by Engr -in- charge
M&L for Rewinding of electric motor AC 3phase 415 volts 50- HZ of capacity 75 HP with supper enamel copper wire of same size and heating and varnishing after removing the old burnt out winding including replacement of bearing etc and testing and commissioning complete all as directed by Engr-in-Charge.
Dismantling the channel base and taking out the pump & motor of capacity 30 HP AC 3 phase 415 volt, disconnecting the pump motor, opening the pump, cleaning de-rusting thoroughly, machining inside body of the pump & repairing by replacement collar rings, gaskets, Impeller locknuts, shaft key etc re-assembling the pump including installtion & testing commissioning complete all as specified and directed.
Repairs to Panel board for pump of any size/ any type by disconnecting and taking out old unserviceable wires and spare parts and rewiring the same with same size of copper wire, replacment of nut & bolts with washers, painting with one coat of synthetic enamel paint of existing colour including necessary preparation of surfaces and replacement of minor defective spare parts including testing and commisioning complete all as specified & directed by Engr-in-Charge.
Top overhauling of Diesel generating set Make Kirlosker NO:- 49-1228/88158, capacity110 KVA as per manufacturers instruction including replacement of all defective parts require for making smooth function of the DG Set complete all as directed by Engr-in-Charge
Taking up / down unserviceable under ground MS pipe 150mm dia joints of flanged pipes in position including removing old rubber gasket nuts bolts complete with fittings all as specified and as directed by Engr-in-Charge
S&F of MS ERW pipe 150mm dia NB heavy duty, flanged, each pipe of length 6 mtr length (ISI marked) all as specified and directed by Engr-in-Charge
S&F of MS ERW pipe 100mm dia, NB, heavy duty, flanged, each pipe of length 6 mtr length (ISI marked) all as specified and directed by Engr-in-Charge
M&L for yard hydrant post/stand post 80mm Dia GI/MS 1.5 mtr height complete including cutting of 150mm MS pipe line and fixing 'T' reducing joint for fixing of 80mm dia MS pipe for stand post incl all fitting for connecting new pipe line complete all as directed.
S&F of stainless steel fire hydrant landing valve type A (single head outlet) of 63mm dia conforming to IS 5290 complete all as specified and directed by Engr-in-Charge as in repair
S&F of hose reel drum 30m long of 20mm dia (conforming to IS 5132) complete all as specified and directed by Engr-in-charge.
S&F of stainless steel nozzle for 20mm dia read (conforming to IS 903) complete all as specified and directed by Engr-in-charge.
S&F of 63mm dia and 15m long canvas hose RRL hose type A(conforming to IS 636) complete including fixing of male & female coupling all as specified and directed by Engr-in-Charge
S&F of gun metal branching pipe nozzle made out of threaded outlet 15mm bore nozzle short of 63mm dia hose real all as specified and directed by Engr-in-Charge
S&F of cabinet hose box of size 800mmx600mmx250mm for keeping 2 nos hose pipe (20mm dia 30m long and 63mm dia 15m long) with branch pipe, nozzle, coupling etc double door with 4mm thick glasses and door frame made of 16 gauge MS sheet, painted fire red outside and brilliant white inside yard, all as specified and directed by Engr-in-Charge
Taking down centrifugal pump of capacity 15 KW(jocky pump;) from existing position, dismantling the same for carrying out of repair work including servicing as per manufacturer instructions and replacing of defective minor spare parts as require and greasing ,alignment the shaft etc reassembling and re-installing the pump set in original position duly connecting with motor and testing to cnfirm the satisfactory working all as specified and directed by Engr-in-Charge .
M&L for renewal of GI earthing by Copper Earthing complete with copper earth plate electrode 600mm x 600mm x 3.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper strip 25mm x3.0 mm as as earthing lead, protected by 40 mm dia light grade GI Pipe bore for protection of copper strip, jointed properly with nuts, bolts, check nuts and washers, making earth test point inside the substation of same material as directed, adequate length of GI pipe 20 mm dia light grade for watering, supply and filling charcoal dust, common salt all around the electrode in alternate layers of 150 mm and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with a Cast Iron hinged cover resting over the Cast Iron frame painted with bitumastic paint which shall be embedded in the block masonry having PGI funnel and wire mesh including necessary excavation and earth work, refilling and connected to main Transformer/LT/HT Panels for its smooth working for feeding the electric supply to domestic quarters including testing of earth resistance as required complete all as specified and directed.
M/S J S ENTERPRISES
Globe Electricals
KWALITY CONSTRUCTION
SANKAR TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .