Maj Rahul Rawat
Garrison Engineer Utility Bathinda Mil stn
REPAIR/MAINTENANCE OF WATER COOLERS OF BATHINDA MIL STN UNDER GE (UTILITY) BATHINDA
2020_MES_345530_1
CA NO GE (U) BTD - 12/2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda Mil stn
Class E cat c i
10 documents required · 10 mandatory
₹500
Garrison Engineer Utility Bathinda
₹38,000
Yes
25 Jul 2020
18 May 2020
17 Jun 2020
18 May 2020
16 Jun 2020
2 Jun 2020
18 May 2020 - 28 May 2020
Amount
Taking out the unserviceable Compressor (Sealed unit) from water cooler 40 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let of make Copeland/Tecumseh/Whirlpool, model KCE 444, AE 4440 YGS, LG 57 including suitable relay, over load and starting/running capacitor, flushing out the old bunt condensite from the gas system by vacuumisation, cleaning the system by CTC solution, pressure testing of the system, gas charging with R-134a gas upto the desired pressure, testing & commissioning the water cooler complete all as specified and as directed by Engineer-in-Charge.Note :- (i) The rate of supply and charging of gas R-134a is included in this item and nothing shall be paid extra on this account.(ii) The rate of supply and fixing of new relay, over load and starting/running capacitor of suitable capacity also included in this item and nothing shall be paid extra on this account.
Taking out the unserviceable Compressor (Sealed unit) from water cooler 60/120 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let of make Copeland/Tecumseh/Whirlpool, model KCE 443, AKR 4460 including suitable relay, over load and starting/running capacitor flushing out the old burnt condensafe from the gas system by vacuumisation, cleaning the system by CTC solution , pressure testing of the system, gas charging with R-134a gas upto the desired pressure, testing & commissioning the water cooler complete all as specified and directed by Engineer-in-Charge. Note :- (i) The rate of supply and charging of gas R-134a is included in this item and nothing shall be paid extra on this account.(ii) The rate of supply and fixing of new relay, over load and starting/running capacitor of suitable capacity also included in this item and nothing shall be paid extra on this account.
Taking out the unserviceable Compressor (Sealed unit) from water cooler 150 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool, model ACJ 513, AW 1000, including suitable relay, over load and starting/running capacitor flushing out the old burnt condensafe from the gas system by vacuumisation, cleaning the system by CTC solution , pressure testing of the system, gas charging with R-134a/22 gas upto the desired pressure, testing & commissioning the water cooler complete all as specified and directed by Engineer-in-Charge.Note :- (i) The rate of supply and charging of gas R-134a / 22 is included in this item and nothing shall be paid extra on this account.(ii) The rate of supply and fixing of new relay, over load and starting/running capacitor of suitable capacity also included in this item and nothing shall be paid extra on this account.
Supply and fixing in replacement of Blower fan motor 1/10 HP suitable for water cooler, single phase 230 Volts including mounting ring/washer complete all as specified and as directed by Engineer-in-Charge. Make and sample as approved by GE.
Supply and fixing in replacement of Blower fan motor 1/35 HP suitable for water cooler, single phase 230 Volts including mounting ring/washer complete all as specified and as directed by Engineer-in-Charge .Make and sample as approved by GE.
Supply and fixing Fan Blade Plastic suitable for 1/35 HP motor.Make and sample as approved by GE.
Supply and fixing Fan Blade Plastic suitable for 1/10 HP motor.Make and sample as approved by GE.
Supply and fixing in replacement Stainless steel taps push button type, 15mm dia for water cooler of any capacity suitable for Usha/Blue Star water coolers.Make and sample as approved by GE.
Material and labour for flushing out the condensate from the gas system of water cooler of capacity 40/80, 60/120,150/150 litres, injecting CTC for demoisturing the system , pressure testing and gas charging with R-134a Gas upto the desired pressure complete all as specified & directed by Engineer-in-Charge.Note :- (i) The rate of supply and charging of gas R-134a is included in this item and nothing shall be paid extra on this account.
Supply and fixing Starting Relay Assembly with Over Load Protector suitable for water cooler. Make : Annapurna /Reneutral /Denfoss
Supply and fixing Running capacitor of 15 mfd.Make ABB / L&T / GE / EPCOS / HPL / HAVELLS/ DUCATI / NEPTUNE
Supply and fixing Running capacitor of 40/60 mfd.Make ABB / L&T / GE / EPCOS / HPL / HAVELLS/ DUCATI / NEPTUNE
Material and labour for cutting the base of water cooler of any capacity and fabrication of new base made from MS sheet 16 SWG and angle iron as per original size and shape including painting complete coolers with a coat of red oxide paint and two coats of synthetic enamelled paint of shade and colour as directed by Engineer-in-Charge. Note:- The rates of material and labour of thimbles, nuts, bolts, washers or any other hardware which requires for fixing is included in this item and nothing shall be paid extra on this account.
Supply and fixing Thermostate valve all as specified and directed.Make and sample as approved by GE.
Material and labour for taking out the inner water tank of water cooler of any size and brazing / welding including applying compounds as required to stop leakage from the water tank, replacement of glass wool / toffed sheet, chicken wire mesh of appropiate thicness and spacing and stoppage of leakage in tubing (if any) around the tank and refixing as per oringinal pattern complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Copper Condenser for 40/80 ltr capacity water cooler all as specified and directed. Make and sample as approved by GE.
Supply and fixing Copper Condenser for 60/120 ltr capacity water cooler all as specified and directed. Make and sample as approved by GE.
Supply and fixing Copper Condenser for 150 ltr capacity water cooler all as specified and directed. Make and sample as approved by GE.
Supply and fixing in replacement of 03 Pin 15 Amp Top Plug, 240 Volts, single phase complete all as specified and as directed by Engineer-in-Charge.Make : ANCHOR / HAVELLS / SSK / LEGRAND / LEADER / MDS
Supply and fixing in replacement PVC float valves, high pressure, with polythene float and fly-nut (PTMT) complete,screwed for iron pipe of brass ferrule, suitable for 15mm bore pipe complete all as specified and as directed by Engineer-in-Charge.Make - PRAYAG / PARRYWARE / COMMANDER / LEADER / CERA
Supply and fixing Copper cable 3 core round of size 23/0.0076 3.00 Metre long including making connection all as specified and as directed by Engineer-in-Charge.Make : Make: HAVELLS/ FINOLEX/ KALINGA/ POLYCAB/ L&T / NICCO / GLOSTER CABLES LIMITED / ANCHOR / KEI INDUSTRIES LTD / PLAZA / PARAGON / HPL / RR KABEL LTD
Supply and fixing Drain Hose Pipe 30mm dia length not less than 1.50 metre complete with clamping arrangment all as specified and directed by Engineer-in-Charge.Make and sample as approved by GE.
Supply and fixing Drain Hose Pipe 40mm dia length not less than 1.50 metre complete with clamping arrangment all as specified and directed by Engineer-in-Charge.Make and sample as approved by GE.
Supply and fixing in replacement Water Cooler Stainless Steel body unit with Condenser Coil, Copper Wound Fan Motor and complete tank including heavy duty copper tubing, stainless steel taps push button type 15mm dia of 40/80 ltr capacity complete all as approved and as directed by Engineer-in-charge. Note :- (i) Compressor / PVC Drain Pipe / copper cable / float valve and any other parts of water cooler shall be measured and paid separately under appropriate item of this BOQ as Supply and Fixing .(ii) The rate of Water Cooler Stainless steel body unit , New copper condenser coil, New copper wound fan motor and complete tank including heavy duty copper tubing, stainless steel taps push button type 15mm dia , nuts , bolts & washers is included in this item and nothing shall be paid extra on this account.
Aman Enterprises
M/S SODHI ASSOCIATES
L H ENTERPRISES
NASIB ENGINEERS AND CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .