Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance D 392 GALI NO 6 NOOR ELLAHI MOUJPUR DELHI DELHI 110053 | NORTH EAST DELHI | DELHI | 110053 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹22,700
Closing Date
6 Aug 2024, 11:00 amClosed
Office of the Ex. Eng. (E and M) M-2
Pkt-A, Dilshad Garden, Delhi-95
Supply Installation Testing and Commissioning of E and M equipment at newly Constructed on-line BPS near Ambedkar Bhawan at Toonda Nagar
2024_DJB_260405_7
NIT No. 04 (24-25)
Open Tender
Miscellaneous Works
Works
60 days
Toonda Nagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Ac No. 50448339804
₹22,700
9 Aug 2024
31 Jul 2024
6 Aug 2024
31 Jul 2024
6 Aug 2024
31 Jul 2024
Fixing of panel M.S. base frame on the foundation and cable laying as required. the job includes proper Installation of the panel as per original position with proper alignment and also making of all electrical connections, fitting etc. in original position with all tools & tackels and man power as required
Supply Horizontal centrifugal pump suitable for Clear water having 35-40 mtr. Head, discharge 600-900 LPM. C.I. impeller, S.S./C.S. Shaft & sleeve, 2900 RPM suction/delivery size: 100/80 mm minimum efficiency of the pump shall be 70%, the pump coupled with 10HP induction motor, 3 phase, TEFC IE2 415 Volts, AC supply, 2900 RPM. Make:-Kirloskar/M&P/lubi/jyoti/DJB approved.
Supply and fixing of Submersible dewatering Pump 3 HP, AC,3 phase,2900 RPM size 40 mm for Dewatering of Pump house water, Make: -KBL/lubi/BS/Havells/Mody pump/Any DJB Approved make.
Providing and laying in position reinforced cement concrete 1:2:4 (1Cement: 2 Coarse: 4 graded stone aggregate 20 mm nominal size) for foundation of pumpsets and panel each including providing fixing of foundation bolt and channel fixing in position with proper leveling and also making arrangement for fixing of pump as per requirement. size 1X0.8X1mtr = 0.8 cum as required i/c foundation bolts.
Making of M.S. Base frame of size as required by replacement of damaged MS C-Channel and MS Flat Bar. Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Fixing of pump sets and panel each M.S. base frame on the RCC foundation and laying of Pipes/Valves with all connections. the job includes proper leveling. Installation of the pump set as per original position with proper alignment and also making of all electrical connections, fitting all valves, bends etc. in original position as required.
Supply/laying of 40 dia. B class GI pipe With Gate Valve Welded and threaded in both sides complete with all connections, threaded bend & schocket as per site requirement. ISI Mark Make: - Jindal/ Parkash/ Tata/Jindal star.
Supply/laying of 100mm dia. B class GI pipe With Welded and threaded flange in both sides complete with reducer, bend with flange and welded support in both flanges as per site requirement. ISI Mark Make: - Jindal/ Parkash/ Tata/Jindal star.
providing/fixing of MS Reducer at suction/Delivery side as per required size with MS flange of required size. MS taper to be made from 10 mm thick duly making taper of rolling welded in all side round length and both ends. Flanges duly painted as required.
Providing/fixing of D-Joints DI/MS at suction/Delivery side as per required size with all accessories and nut bolts.
Supply of Nut- Bolt with washer of good quality size as per requirement. ISI Mark.
Supply of rubber packing sheet with 50 % Neoprene (1.5 mm to 25 mm) ISI Mark. SOR (E&M) item code 22.6.1
Supply of LT Power Copper cable, solid conductor, XLPE insulated, PVC sheathed, armoured, 650/1100 V grade as per IS 7098(Part 1) 1988 size 3 core 6 mm2 for connection pumpset to panel. Make: - Havells/ Grandley/ Gloster/ finolex.
Supply of LT Power aluminum cable, solid conductor, XLPE insulated, PVC sheathed, armoured, 650/1100 V grade as per IS 7098 (Part 1) 1988 size 3.5 core 35 mm2 for main switch to panel etc. Make: - Grandley/ Gloster/ Havells/ finolex.
Main switch 200Amp. Open execution type with Kit kat fuse unit. Make: L&T/ Havells
CI double flanged swing type non return valve as per IS:5312 PN 1.0 CI body door / bronge to rubber ring / SS 410 twin pin, Size 100mm dia. SOR (E&M) item code 4.9.4
C.I. double flanged non rising spindle sluice valve P.N 1.0 IS:14 sub, CI body / wedge / bronze ring / S.S 410 shaft construction & S.S. IS : 6603 Gr. 12 CR 12 CISI marked manual operation, Size 100mm dia. SOR (E&M) item code 4.7.4
Providing/Fixing of pressure gauge of 100 mm dia. having required range with accessories such as GI fittings, Bib cock etc. required complete the work in all respect at pump sets delivery. Make: - Hguru/Fibeg/Any DJB Approved make
Providing/fixing of water storage tank of capacity 500 Litre at Sonia Vihar BPS with pipe fittings and All 20mm nipple - 4 nos, tank nipple - 1 no, pipe -10 mtr, elbow-4nos, Tee- 2 nos, socket- 5 nos, Reducer socket ¾" to ½" - 2 nos. Union- 2nos and gun metal gate valves-2 nos, with the help of manual labour, tool & tackles. Make -water storage tank: -Sheetal/ Supreme/Aquapure/Any DJB approved. Make - pipe fittings: - ISI mark.
Testing / commissioning of the pump set and all electrical items by proper Meggaring of all equipment for phase to phase, neutral to body, neutral to earth and phase to earth on NO load & full load after commissioning of all connections.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (D.S.R 2022 Code No. 1.8.3) Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm (D.S.R 2022 Code No -1.17.12)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm (D.S.R 2022 Code No -1.17.21)
Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. (D.S.R 2022 Code No -1.29)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 06-way, Double door (D.S.R 2022 Code No -2.3.1)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (D.S.R 2022 Code No -2.10.1)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredSingle pole and neutral (D.S.R 2022 Code No -2.10.2)
Supply and fixing if 32mm dia. 02 Mtr. long G.I pipe (medium class) bracket for mounting of fluorescent/ HPMV/HPSV street light fitting on pole/ wall including bending the pipe to the required shape, 2 Nos. 40mm X 3mm flat iron clamps with nuts, bolts, and washer, painting the flat iron with primer and finish paint etc. as required. DSR-2022, Item code- 12.34
Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC Insulated, copper conductor, single core cable and earthing etc. as required. DSR Item No. 1.41
Supply of ceiling fan having size 1200 mm (48') in white colour. Make: - Anchor/orient/Standard/ Any approved make by DJB. DJB SOR 2022 Item no. 20.1.2
Supply of Air Circulator of size 450 mm Make: - Anchor/orient/ Standard/Almonard / Any DJB approved make. DJB SOR 2022 Item no. 20.3.1
Supply of exhaust fan having size 450 mm (15'), 1440 R.P.M. in grey colour of single phase 230 volts. Make: - Anchor/orient/ Standard/Almonard/ Any DJB approved make. DJB SOR 2022 Item no. 20.2.3
Supply of Endura Linear NEO Surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver 36 W LED 857 Make: Havells /Philips/Crompton/ DJB approved make. DJB SOR 2022 Item no. 19.3.3
Providing/ Fixing of 45W L.E.D Light energy saving & environmental friendly long-life Versatile pressure die-cast aluminum IP 66 roadway laminate with high power L.E. D as light source. Make-Havells/Bajaj/Crompton. DJB SOR 2022 Item no. 19.10.5
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required details of cost for one Set DSR-2022 E&M Code-5.4
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. DSR E&M 2022 item no. 5.11
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) (DSR E&M 2022 item no. 5.9)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. DJB DSR Item Code: 15.3
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. For laying GI earthing strip and dismantling of old strip DSR Civil 2021 item no. 15.7.4
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6(1Cement:3coarses and(zone-III):6graded stone aggregate 40mm nominal size) DJB SOR Item Code: 46.1.6
Monarch Engineering Works
SONI SALES and SERVICE
Super System Engineers
Devraj Enterprises
Raj Engineering Co.
Gupta Brothers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .