Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | ₹14.5 L Quoted ₹15.3 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹15.3 L+₹1,588 (0.10%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | ₹15.3 L+₹1,588 (0.10%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹15.3 L+₹1,592 (0.10%)Rejected-Finance NOT FOUND | ₹15.3 L+₹1,592 (0.10%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹18.3 L+₹3.0 L (19.4%)Rejected-Finance | ₹18.3 L+₹3.0 L (19.4%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹20.9 L+₹5.7 L (37.0%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹20.9 L+₹5.7 L (37.0%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹24.7 L
EMD Value
₹49,400
Closing Date
1 Aug 2020, 6:00 pmClosed
CWE (AF) Gurgaon
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-110010
REPAIR AND PERIODICAL MAINTENANCE OF MAIN SUPPLY DISTRIBUTION SYSTEM OF HT LINES AND ALLIED WORKS OF EXTERNAL ELECTRIFICATION AT AF STN ARJANGARH UNDER GE AF GURGAON
2020_MES_358031_1
CA NO CWE/GGN/G-12/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Arjangarh
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Gurgaon
₹49,400
Yes
25 Aug 2020
3 Jul 2020
3 Aug 2020
3 Jul 2020
1 Aug 2020
18 Jul 2020
Amount
Excavation of hard / dense soil in trenches not exc 1.5 meter wide & not exc 1.5 mtr in depth: for foundationetc or for manholes, laying of pipe in any type of soil and getting out complete all as specified and directed.
Excavating of disintegrated soil in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for under ground cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out of disintegrated rock complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and directed.
M & L for Old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and directed.
M & L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete all as specified and directed.
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable 3 core with stranded aluminium conductor, 11000 volts grade earthed , laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 95 Sqmm nominal cross sectional area complete all as specified and directed.
All as per item no. 10 but Size 120 Sqmm complete all as specified and directed.
Supply and fixing of GI tubing, light grade, 100 mm bore with all fitting laid in trenches / fixed on pole / wall for protection of cables in repairs complete all as specified and directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
M&L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed.
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-55 ( 11 meter long) complete, Including disconnecting and taking out old damage PCC pole complete all as specified and directed.
Supply and fixing prestressed concrete pole 11 meters long 152 mm x 152 mm at top and 152 mm x 260 mm at bottom of class 9 complete, Including disconnecting and taking out old damage PCC pole complete all as specified and directed. Make - Hindustan / Indian PCC Pole / Daya Tech Services PVT LTD .
Note for item 17.00 & 18.00 - Earth work and PCC shall be measured and paid separately as these respectively.
Supply , stringing and fixing of aluminium conductor steel reinforced ( ACSR) of any type including binding with and including suitable size of binding wire complete . .Including dismantling and taking out warn outACSR conductor from overhead electric line complete all as specified and directed.
All as per item No. 19.00 but GI wire 4 mm dia complete all as specified and directed.
Supply and fixing GI stay wire of 7/4 SWG upto required length including taking out and u/s one complete all as specified and directed.
Supply and fixing mild steel galvanised stay assembly set complete comprising of 14mm dia, 400mm long stay bow, 2150mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, all as shown in electrical plate No.1 of MES Schedule part-I 2010 complete including dismantling and taking out old damaged stay complete all as specified and directed. Note :- PCC , earth work and Insulators etc shall be measured and paid separately.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, including dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as specified and directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for HT size 25 X 20 Cm and taking out of us one complete all as specified and directed.
M& L Pin type, porcelain, vitreous, white, brown or green insulator, 150 mm height, 150 mm dia for 11000 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut andand taking out of unsv one complete all as specified and directed. Make -PACTIL / MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
S&F new Shackle type, porcelain, vitreous, white, brown or green insulators 150mm dia and 150 mm height for working pressure 11000 volts including galvanised mild steel strap 38 x 5 mm size, washers, 20mm dia insulator bolts, washers & nuts and and taking out of U/S one complete all as specified and directed. Make -PACTIL / MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
M& L for Disc type insulator, porcelain, vitreous, white, brown or green insulator ( Single disc assembly ) of size 145 mm height, 255 mm dia ball socket type for working pressure 11 kv volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut and taking out of U/S one complete all as specified and directed. Make -PACTIL / MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
M& L loop type, porcelain, vitreous, white, brown or green insulator large type 140 mm , clearence of hole 25.5 mm for 11000 volts grade including out of U/S one complete all as specified and directed. Make -PACTIL / MADRAS PORCELAIN / NGEF / JAIPURIA / BHEL .
Supply & fix lightening arrestor linear resistance type distribution class 9 KV RMS suitable for 11 KV system pole mounting type conforming to IS - 3070 Part-I including taking down existing U/S one complete all as specified and directed. Make - BHEL / CG /BHARAT BIJLEE / OBLUM / PRAGATI .
M&L for vice type connectors of size 4 to 7 mm dia consisting of two brass plates and two steel bolts and nuts for two conductor of equal or unequal sizes for non tension connections including treatment of connector and ACSR conductor with conducting jelly , fixed in repairs complete all as specified and directed.
M&L for vice type connectors of size 10 to 13 mm dia consisting of two brass plates and two steel bolts and nuts for two conductor of equal or unequal sizes for non tension connections including treatment of connector and ACSR conductor with conducting jelly , fixed in repairs complete all as specified and directed.
Supply and fix gang operated air break switches, triple pole, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level horizontal / vertical type for rating upto 400 Amps, 11000 volts complete with GI operating pipe of heavy duty including taking down U/S one complete all as specified and directed.
S/F drop out fuse assembly complete set with Insulator-06 Nos and connected accessories for 11000 V grade of 400 Amp s capacity including taking down U/S DO fuse assmbly complete all as specified and directed. Make - BHEL / JAIPURIA / RASHTRIYA / MEI .
Expulsion fuse single pole capacity of Voltage 11KV and current up to 25 Amps complete all as specified and directed.
All as per item No 34.00 but capacity of Voltage 11KV and current above 25 & upto 50 Amps complete all as specified and directed.
All as per item No 34.00 but capacity of Voltage 11KV and current above 50 & upto 100 Amps complete all as specified and directed.
Taking down and repairing/overhauling of air break gang operated switch with DO fuse unit 200 Amp/400 Amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically / horizontally , replacement of broken/worn-out components, oiling and greasing of mechanical moving parts, smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the same after repair including proper allienment complete all as specified and directed. Note:- Warn out component/ insulators / ASCR shall be measured and paid separately
Supply only following components to incorporated for repair of air break gang operated switch :-
(a) Female contact or fixed contact heavy duty and high conductive metal complete capacity 200A/400 Amp11 KV Make Rastriya/Jaipuria
(b) Male contact or Moving contact heavy duty and high conductive metal complete capacity 200A/400Amp 11 KV . Make Rastriya/Jaipuria
(c)Tinned copper flexible jumper 200A/400A Make Rastriya/Jaipuria
(d)Fixed top contact & Fixed bottom contact 11 KV 400 Amp for DO fuse unit. Make Rastriya/Jaipuria
(e) Fiber glass tube with metalic fittings both ends suitable for DO fuse 11KV Make Rastriya/Jaipuria
(f) Supply only mild steel jumper as per sample. Make Rastriya/Jaipuria
(g) Supply only back connector plate as per sample.
(h) Supply only post insulator 11 KV as per sample.
Disconnect HT & LT connections from any type of transformers indoor/outdoor, plinth/ pole mounted in any location in the restricted areas of 503 SU shifting to workshop for carry out any repair works, as directed install back in original location including re-connection of HT & LT supply system of capacity complete all as specified and directed.
(a) 100 to 160 KVA
© 630 to 1000 KVA Note:- (a) Required tools & plant including lifting arrangement, transport etc shall be included in the rate quoted. (b) Any damage occurred during lifting/ transporting, the firm will be responsible to rectify such defect free of cost.
Shifting of trolly mounted transformer to the site and disconnecting the defective transformer from HT and LT side connection and connecting the trolly mounted stand by transformer by making neccessary HT /LT side connection properly for temporary basis and disconnecting the same after repair of removed /issolated transformer and connecting work shop repaired transformer complete all as specified and as directed.
Repair / Servicing / maintenance of transformer 11 / .433 KV indoor / outdoor type , plinth / pole mounted type including the following work services :- (a) Disconnecting transformer from electric system and providing electric power to user from alternative arrangement including taking out from existing position . (b) Decanning of transformer oil , opening top cover , disconnecting of all internal connections , lifting and taking out of core assemble , LT / HT bushing , Tap changer etc ,cleaning and inspection of core and winding , segrigetion of serviceable and unsv items , removing of sludge and cleaning tank and cooling pipes / fins /tanks with pressure water and drying the tank complete. (c) Replacinig Unsv LT / HT bushing by replacing rubber / cork oil seals and damage terminal rod & replacement of Transformer cover gasket of rubber cork sheet . (d) Re installation of TFR including reassembling of core / winding assebly complete including replacement of unsv parts , repair the defective parts and tighting of all loose / sparks wire / nut bolts etc and refixing the to the existing position , connecting with HT/LT cables and earthing strip and testing complete including necessary Transportation ( If required ) to the work shop and back and including Dehyderation and refilling of existing or new transformer oil of required quantity . Note : (i) Dehydration of oil and new transformer oil shall be measured and paid seperately. (ii) The cost of transportation of transformer from site to workshop and back shall be deemed to be including in the quoted rate. (iii) HT & LT Bushing, Tap Changer will be measured & paid seperately. (iv) In case HV/LV winding found damages then contractor shall be made serviceable with new winding and the same will be measured and paid seperately. (v) The rate of cork sheet & packing material for above cap of X-mer are included in quoted rate.
(a) Transformer capacities 100 to 160 KVA
(b) Transformer of capacity 400 KVA
(c) Transformer of capacity 630 to 1000 KVA
Removing of existing damage insulating material from LV Winding , Cleaning the winding and reinsulating the LV Winding with approved grade and make of insulating paper and heating the coil in the heat chamber to obtained desired result of insulating resistence complete and re-installation complete all as specified and directed.
Material and winding of HV side copper winding with super enammeled copper wire of existing size , gauge and weight of approved grade wire including necessary insulating material and heating the coil in the heat chamber to obtained desired result of insulating resistence complete and re-installation complete all as specified and directed.
Material and winding of LV side copper winding with existing size / type and weight of copper strip winding of approved grade including rapping of insulating tap and insulating material and heating the coil in the heat chamber is obtained desired result of insulating material complete all as specified and directed.
NOTE FOR ITEM NO 43.00 & 44.00 : - (i) Contractor shall be open the core assrmbly and segrigatted the serviceable / unser winding and shown to the EIC before and after incorportation to the TFR . (ii) Actual weight of the new winding shall be measured and paid . (iii) In case of damages of the LV Windings and required re insulation of LV Winding then shall be measured and paid seprrately .
Supply and replace of silica jel cristal complete all as specified and directed.
Supply and fixing in repalcement of heavy duty breather assembly with Silica jel cristal complete for Transformer complete all as specified and directed.
Supply and fixing of new temprature guage ( 0 degree to 120 degree C ) range dial temprature as directed including taking down old unserviceable guage complete all as specified and directed.
M & L for transformer oil level indicator assembly complete with iron frame, glass, rubber packing sheet, nuts, bolts and washers etc as per existing complete all as specified and directed.
M&L for Synthetic insulating rubber mat of size 2 m x 1m x 12 mm with ISI mark suitable for 1.1 KV rating in red colour complete all as specified and directed .
Materials and labour for removing the burnt out/ damaged LV bushes with porcelain insulator and replace with Brass LV bushes, nuts , check nuts, rubber washer etc complete as per the existing size / model, for transformers of capacity complete all as specified and directed.
(i)100 to 160 KVA
(ii)400 KVA
(iii) 630 to 1000 KVA
Materials and labour for removing the burnt out/ damaged HV bushes with porcelain insulator and replace with Brass HV bushes, nuts , check nuts, rubber washer etc complete as per the existing size / model, for transformers of capacity complete all as specified and directed.
(i) 100 to 160 KVA
(ii) 400 KVA
(iii) 630 to 1000 KVA
Dehydration of existing transformers 11 KV and servo voltage stabilizer of oil minimum three cycles to achieve dielectric strength up to 60 KV in 2.5 mm gap electrode including toping up of oil if required at site complete all as specified and directed. Note : (i) Dehydration of transformer / voltage stabilizer oil shall be carried out at site and contractor shall be taken the testing result before and after dehydration of oil and shown to the EIC at site and maintain necessary documents for record . (ii) Dehydration Machine with all T&P & Transformer oil testing machine for dehydration of Transformer oil and necessary transportation for the machines is arrange by contractor . (iii) Oil required for topping up the transformer / voltage stabilizer will be measured & paid separatly
Supply and charging topping up of new low viscosity transformer oil from sealed drums confirming to IS 335-1993 Part-II after testing the correct dielectric strength up to 60 KV at 2mm gap duly de-hydrated complete all as specified and directed.
Off load Tap changer switch of existing model / type of Transformer of capacity 100 to 160 KVA complete all as specified and directed.
Off load Tap changer switch of existing model / type of Transformer of capacity 400 KVA complete all as specified and directed.
Off load Tap changer switch of existing model / type of Transformer of capacity 630 to 1000 KVA . NOTE FOR ITEM NO 54.00 to 56.00 :- (i) Fixing charges will be included in quoted rate in item no 41.00 .
M&L for preparation of old painted surfaces steel by brushing/changing stain, greasy spots with thinner and apply two coats of spray painting with super enameled smokes grey colour paint of approved by Dept. and writing the MES / SM No with white paint as directed to transformer indoor/outdoor installed at various different locations complete all as specified and directed.
(a) 100 to 160 KVA
© 630 to 1000 KVA
Disconecting the LT incoming and outgoing main cables of any size ,strip opening of the voltage stablizer , draining out the oil into a cleaned container ( container shall be arranaged by the contractor ).Lifting up dimmer and transformer with help of tripoid and chain pulley etc (The T & P shall be arranged by contractor ), checking of all the parts ,cleaning and servicing of the container,dimmer,transformers coil and allied parts including replacememnt of minor parts like nut bolts ,connecting wires ,rubber seals /packing etc . ( The repair/ replacement of the major parts shall be measured and paid seperately ) and reassembling the volt stablizer complete (in reverse order.). Refilling oil ater dehydration and filtration/cleaning by centrifuging machine including testing of samples before and after dehydrations and filtration complete, and reconeecting the incoming and outgoing cable connection, commisioning and testing of the volt stablizer on load complete all as specified and directed.
(a) 100 to 160 KVA
(b) 300KVA Note: The cost of dehydration of oil shall be measured and paid under respective item of schedule
M&L for preparation of old painted surfaces steel by brushing/changing stain, greasy spots with thinner and apply two coats of spray painting with with super enameled smokes grey colour paint of approved by Dept. and writing the MES /SM No with white paint as directed to Servo Volage Stab. indoor/outdoor installed at various different locations complete all as specified and directed.
(a) 100 to 160 KVA
S & F in replacement of Electronic circuit card( P.C B) card with drive assembly for unbalanced type stablizer complete all as specified and directed. Make : Volina or equivalent ISI marked /approved.
(a) 100 to 160 KVA
S & F in replacement of Auto/manual switch for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed.Make : Volina or equivelant
S & F in replacement of Push button switch for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed. Make : Volina or equivelant
S & F in replacement of Micro switch for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed. Make : Volina or equivelant
S & F in replacement of DPDT switch for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed. Make : Volina or equivelant
S & F in replacement of Panel lamp for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed. Make : Volina or equivelant
S & F in replacement of Potentiometer for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed. Make : Volina or equivelant
S & F in replacement of Volt meter of Range 0 to 300V (Digital/analog) complete all as specified and as directed.
S & F in replacement of Volt meter of Range 0 to 500V (Digital/analog) complete all as specified and as directed
S & F in replacement of Ampere meter of Range 0 to 500 Amps with suitable size of C.T. (Digital/analog) for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed.
S & F in replacement of P.C.B. holder for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed. Make : Volina or equivelant
S & F in replacement of Trigger Transformerfor servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed. Make : Volina or equivelant
S & F in replacement of Servo motor 10 K.G. torque for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed.Make : Volina or equivelant
(a) 100 to 160 KVA
S & F in replacement of R.C. net work for 10 K.G. motor for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed. Make : Volina or equivelant
S & F in replacement of Carbon Brush for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed. Make : Volina or equivelant
S & F in replacement of finger holding carbon brush for servo type voltage stablizer 100 to 300 KVA capacity complete all as specified and as directed. Make : Volina or equivelant
M & L for complete repairing / Serviceing of HT 11 KV Vaccum circuit breaker (VCB) after disconnecting of all incoming and outgoing connection, checking/finding of the defective spare/parts, removing of all moisture content with suitable grade chemical, replacement of rusted nuts,bolts and washer, replacement of all unserviceable post insulator and repair of all busbar joints and covered with HT insulation tape, painting of all internal surface where required and complete external surface as per existing colour and quality, replacemnt of all defective internal AC/DC circuit wiring, repair/servicing of breaker trolly including motorized operating mechanism, CT/PT, power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow (Over Current, Earth Fault, Differential) in sequence from down streem to receiving Sub stn for accuracy and effective functioning of VCB complete all as specified and as directed. Note : (i) Nuts , bolts, washer, painting, cleaning material, insulation tape, copper wire for circuit wiring and defective HT 11 KV 2 Amp fuse , carrier oiling greasing to charging spring ,replacement of HRC fuse 110/220 volt 5 Amps setting of over current , earth fault ASHIDA ADR131A relays / L&T Relay complete other minor items for repair of breaker shall be deemed in qouated rate. (ii) Replacement of major unserviceable spares/accessories shall be measured & paid separately under relevant items of this Schedule ‘A. (iii) During repair work/serviceing work carried out in VCB panel all the existing HT connection/HT cable connected with other VCB for continuous supply to the feeder.
(a) Supply only shunt trip coil assembly suitable for HT VCB , operating on 30/110 volt system and testing complete all as specified and directed . Make: Crompton / AE/Siemens or existing model .
(b) Supply only closing / tripping coil operated on 110/30 volt system suitable for working of relay for HT VCB complete all as specified and directed . Make: Crompton / AE/Siemens or existing model .
(c) Supply only Analogue Amp-meter CT operated of size 144 mm x 144mm, suitable for HV panel board 11000 V ranging 0 to 100/50 Amp complete all as specified and as directed. Make: AE/Siemens/CG/Recom or existing model.
(d) Supply only Analogue Volt meter of size 144 mm x 144 mm, suitable for HV panel board 11000 V, ranging 0 to 15 KV (excluding PT) complete all as specified and as directed.Make: AE/Siemens/CG/Recom or existing model.
(e) Supply and testing Epoxy resin cost totaly enclosed dual core type Current transfomer (CT) for protection and measuring of system having ratio of 100/50 : 5 / 5 A , Burden-10VA, class-I, insulation level 12/28/75 KV, STC- 18.4 KA for 1 sec as per ISS-2705 and IEC-60044 including dismantling of old one complete all as specified and directed .Make: Areva(Alstom)/Crompton Greves/Siemens or existing model.
(f) Supply and testing Epoxy resin cost totaly enclosed dual core type Current transfomer (CT) for protection and measuring of system having ratio of 60/30 : 5 / 5 A , Burden-10VA, class-I, insulation level 12/28/75 KV, STC- 18.4 KA for 1 sec as per ISS-2705 and IEC-60044 including dismantling of old one complete all as specified and directed .Make: Areva(Alstom)/Crompton Greves/Siemens or existing model.
(g) Supply and testing voltage transformer of ratio 1100 RT3 / 110RT3V Acc class 1.0 burden 200 VA STC 25 KA for 1 sec including copper extention strips of required size and rating complete all as specified and directed .Make: Areva(Alstom)/Crompton Greves/Siemens or existing model.
(h) Supply only power factor meter digital type of 146 mm x 146 mm suitable for fixing with the existing panels including taking out of old unserviceable PF meter .
(j) Supply only spring charging motor suitable for fixing with 11 KV indoor type VCB panel complete all as specified and directed .
(k) Supply only charging bottle suitable for 11 KV VCB trolly complete all as specified and directed .
(l) Supply only moving contacts of VCB made of copper and suitable for 11 KV VCB Trolley complete all as specified and directed .
(m) Supply only battery 2 volts , 100 AH for battery bank installed at power house complete with termination clips complete all as specified and directed .
(n) Supply only battery charger suitable for charging to battery bank 2 volts 100 AH (15Nos) including digital type volt meter , amp meter etc complete all as specified and directed .
(o) Supply only Heater 230 volts AC 60 watt for 11 KV HT VCB panel complete all as specifed and as directed. Make :Heatco/Vileco Electrical.
(p) Supply only Neon indicator lamp LED type with high intensity 40-240 volts AC and 40-220 volts DC with holder complete all as specified and as directed. Make:- Vanishns/AE/Recom
(q) Supply only limit switch 110 volts operated suitable for HT 11 KV VCB charging motor circuit. Make: BCH/Crompton Greaves/STS.
(r) Supply only copper bus bar of size 50 mm X 6 mm thick wrapped with HT sleeves and provision of making holes as required with copper nuts, bolts & washers suitable for HT 11 KV VCB panel complete all as specified and as directed.
(s) Supply only vacuum interputer for HT11 KV VCBs, 630 Amps, breaking capacity 13.1 KA suitable for Alstom make VCB complete all as specified and as directed. Make :- Bharat Electronics/CG/Areva/Alstom
Calibration of Protective relay programmable type in HT panel with carrying out secondary injection test, set the relays in accordance with the supply agency Protection/Tripping range so as to trip the MES breaker before tripping the fault to supplier grid/ system. All parameter in MES breaker tripping setting in relays shall be arranged in such away that any fault occured in the feeders after the recieving station must not transfer to the suppliers system.
Repair to LT panel/ Feeder pillar box outdoor with replacing any damaged worn out hinges, weildings the locking system, replacing the damaged polypropolene clear glass of size 6x2 ft (3 piece) in MAP substation panel.
Supply and install capacitor metalized poly propylene ultra heavy duty (LTXL) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% complete all as specified and directed.
(a)25 KVAr
(b)20 KVAr
(c)10 KVAr
(d) 5 KVAr
(e) 2KVAr
(f)1KVAr Make : L & T , Syntron,Epcos & equivalent of other approved makes.
Supply and fix in repair 3 phase 24 -240 Volts AC/DC supply over current + earth fault relay with high set having define time characteristics and last 30 trips data recording with date and time as well as password protection complete including necessary electric connections and testing all as directed as specified. Make - L& T , Cat no.- MC61ANX2200 or equivalent .
M&L supply and fix in repair heavy duty Contactor for three phase capacitors including necessary connections all as directed for the following capacity
(a) 3 pole power contactor type MNX-110.
(b) 3 pole power contactor type MNX-70.
(c) 3 pole power contactor type MNX-32.
(d) 3 pole power contactor type MNX-18.
(e) MCB TP of 63 amps of C series .
(f) Unsheathed single core Copper wire of 19/16 .
Maintenance / repairs to APFC panels, 3 phase AC 415 V, by skilled technician and replacement of unserviceable spares as specified below for capacities 40 to 200 KVAR including replacement of short circuited copper conductor cables with appropriate gauge PVC insulated stranded copper conductor cables and cleaning of all moving contacts of relay contactors, tightening of all terminals and testing afer repairs to ensure serviceability and corrected output at specified powerfactor complete all as specified and directed.
M & L for Restrainingre of HT /LT over head line single ACSR conductor comprising of any size of conductor aluminium/copper/GI after opening binding wire from insulators and replace binding wire and achieved permissible sag limit of over head line conductor complete all as directed and specified.
Trimming of tree branches upto 11m from ground level all along the over head electric supply lines, to clear all branches maintaining a clear distance of 1.5m from the conductors. The maximum average dia of branches shall not exceed 20cm. After trimming the cut pieces and branches are cleared from the road upto a distance 200m complete all as specified and directed. Note: (a) Required tools, ladder, Safety equipment etc. shall be arranged by the firm. (b) Area wise shut down to feeders shall be given on one day notice upto 4hrs.
Supply & installation of waterless and maintenance free earthing ( grouting ) electrode of size dia 80 mm x length 3000 mm with 17.2 mm MS/Cu bonded MS conductor and pre cast or in-situ cast in high purity electrically conductive granular ( Marconite ) having ultra low resistivity of 0.001 Ohm -m . (Provide the resistivity certificate for the same ) Electrode made of electrically conductive granular mixed with cement to pre cast or backfill the voids surrounding the metal conductor in augured bore hole of 80 mm dia x 3000mm depth , resulting in increase of effective surface area of the earth electrode and in case of high soil resistivity a grid of multiple electrodes to be installed to lower the desired earth resisitance value . Electrode's top terminal should be sealed permanently with the conductive concrete and GI extension strip taken out be terminated at earth bus bar complete all as specified and directed. Note ;- (a) Cost of boring for grouting of electrode as per manufacture direction & earth strip from top of electrode to 7.5 metrs with hardware like nuts , bolts and washers of stailess steel etc shall be deemed included in the above quoted items. (b) Electrode should withstand fault current up to 30 KA for 1 second .(c) Main earth lead beyond 7.5 meter shall measured and paid saperatly.
M & L for Earthing to OH/Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 1991, GI earth lead wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI medium grade and provision of earth test point including testing on completion complete all as specified and directed. Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
All as per above item no - 87.00 but main earth lead 32 x 6 mm galvanised iron strip.
All as per above item no. 87.00 but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead.
M & L in repair for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall in repair complete all as specified and directed.
M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M & L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Supply & Fix shock treatment chart standard size with diagrams and illustrations dully framed properly laminated including hooks for fixing/ fastening. The detail illustrations shall be in Hindi & English complete all as specified and directed.
Supply only First Aid Box including the following medicine & accessories a. Adhesive medical band aid m 12 to 15 mm width - 1 roll ( not less than 1m). b. Dressing cloth medical use 50mm width - 1 roll (not less than 5m) c. Bitadine/ Povidine - 1 tube. d. Silver sulpha iodide / Burnoll -1 tube e. Medicated dressing cotton - 1 roll not less than 50 grams. f. Paracetamol 500mg - 15 Nos g. Stainless steel scissors - one small size.
supply only Hand Gloves industrial type ISI marked for use of electrical maintaenece suitable for 11000 volt grade complete all as specified and directed.
Highly insulated FRP Earth/Discharge rod of assembled height 15ft in section 03x5ft height. Die cast alu. Grounding "C" clamp. ISI marked PVC insulated multi-stranded 440/11000V grade transparent copper cable 35sq.mm (length 25ft) as per IS-694.
Supply & Fix safety precaution & first aid instruction chart with sketch & illustration muity colour for the use in electricity receiving station dully laminated & framed including hooks for fixing/ fastening . The detail illustrations shall be in Hindi & English
Printing in multy colour, laminate & framed the details of SOP & fixed / hanging on wall in the substation all as specified and directed chart of size 50x70cm or above.
Supply only conventional type 3 1/2 digit LCD display which can measure Earth resistance / Earthing measurement instrument. Make: shanti , motwane.
Supply only insulation measuring tester size upto 500V. Make: shanti , motwane,yokins.
Supply only insulation measuring tester size upto 5000V. Make: shanti , motwane, yokins.
Material and labour HT Cable rout indicator made out of PCC Post of 1:2:4 of size not less than 20 x 15 cm and one meter height with making embossing the following letters of size 100 mm in the PCC Post " HT CABLE OF 11000 volts " including necessary excavation and PCC 1:2:4 (30 X 30 x 30 CM ) for embeding in the ground complete all as specified and directed.
M&L for painting of bottom portion of the pole upto 1.50 m from top of the copping with one coat of synthetic enamel paint over a coat of red oxide primer marking pole numbers in a 20 cm dia yellow circle & marking three white & three blue bends width 15 cm by fluorescent paint complete all all as specified and directed .
Supply and fix in repair ACB 4 pole 415 volts , 1000 amps , AC 50 Hz with breaking capacity 50 KA conforming to IS/IEC-60947-2 with themal magnetic release and manual drawout type ( Thermally adustable type ) inclding electrical connection as per site requirement complete all as specified and directed .
Supply and laying of back feel compound in earth pit complete all as specified and directed . Make - S N Engineering or Equivalent .
Net Contract Sum will be after deducting Sch of Credit of Rs 78538.00
New Era Engineers
shiv shanker enterprises
M/s Birja Nand
Shiv Enterprises
M/S Sanjay Enterprises
BLUE HILL ELECTRICAL AND ELECTRONICS
Ridhi engineers and builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .