GE Partapur
GE Partapur Pin 908102
Repair and maint of LT transmission lines, underground cables, LT panels and other allied works at Khalsar and Hunder area under GE Partapur
2022_MES_520747_1
GE/P-27/2022-23
Open Tender
Civil Works
Item Rate
183 days
GE Partapur
As per tender documents
8 documents required · 8 mandatory
₹500
GE Partapur
₹40,000
Yes
12 Jul 2022
29 Apr 2022
28 May 2022
29 Apr 2022
26 May 2022
14 May 2022
2 May 2022 - 6 May 2022
Amount
Taking out un-serviceable/faulty cable/service connection cable of any grade / type / size / core for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge(Note- Excavation and earth work shall be measured and paid separately)
Supplying and laying passing through pipe or laid in trenches underground XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 10 x 2 Sqmm complete. Note :(i) Excavation work will be paid under appropriate item of BOQ. (ii) Necessary spares such as glands, lugs, nuts, bolts etc including relaying and making connections of connected cables of any size is deemed to be inclulusive of quoted rates.
Supplying and laying passing through pipe or laid in trenches underground XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 16 x 4 Sqmm complete. Note : (i) Excavation work will be paid under appropriate item of BOQ. (ii) Necessary spares such as glands, lugs, nuts, bolts etc including relaying and making connections of connected cables of any size is deemed to be inclulusive of quoted rates.
Supplying and laying passing through pipe or laid in trenches underground XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 25 x 4 Sqmm complete. Note :(i) Excavation work will be paid under appropriate item of BOQ. (ii) Necessary spares such as glands, lugs, nuts, bolts etc including relaying and making connections of connected cables of any size is deemed to be inclulusive of quoted rates.
Supplying and laying passing through pipe or laid in trenches underground XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 35 x 3.5 Sqmm complete. Note : (i) Excavation work will be paid under appropriate item of BOQ. (ii) Necessary spares such as glands, lugs, nuts, bolts etc including relaying and making connections of connected cables of any size is deemed to be inclulusive of quoted rates.
Supplying and laying passing through pipe or laid in trenches underground XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 50 x 3.5 Sqmm complete. Note : (i) Excavation work will be paid under appropriate item of BOQ. (ii) Necessary spares such as glands, lugs, nuts, bolts etc including relaying and making connections of connected cables of any size is deemed to be inclulusive of quoted rates.
Supplying and laying passing through pipe or laid in trenches underground XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 70 x 3.5 Sqmm complete. Note : (i) Excavation work will be paid under appropriate item of BOQ. (ii) Necessary spares such as glands, lugs, nuts, bolts etc including relaying and making connections of connected cables of any size is deemed to be inclulusive of quoted rates.
Supplying and laying passing through pipe or laid in trenches underground XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 185 x 3.5 Sqmm complete. Note : (i) Excavation work will be paid under appropriate item of BOQ. (ii) Necessary spares such as glands, lugs, nuts, bolts etc including relaying and making connections of connected cables of any size is deemed to be inclulusive of quoted rates.
Re-stringing, restretching ACSR conductor of overhead HT/LT line on steel poles after removing binding from insulator and rebinding the conductor with insulator including providing new binding wire jumpering providing with sleeves of appropriate size, ACSR conductor with colour code sleeves after restraining and removing unavoidable sags in the lines, complete all as specified and directed by Engr-in-charge.
M&L for Aluminium conductor steel reinforced (ACSR) in replacement as in over head conductor including provision of aluminium tapes for binding all as specified and directed by Engr-in-Charge. Note : (i) weight of ACSR conductors shall be determined by measuring the horizontal distance between center of two adjacent poles and compounding the weight of conductors of size and length provided and 3% extra added for sag, jointing, jumpers etc. (ii) The weight of the aluminium tapes shall not be added in the weight of the conductors for payment purpose. (iii) Size of ACSR conductor will be decided by GE/Engr-in-Charge as per electric load and site requirement.
Supply and fix in replacement Pin type insulator, porcelain, vitrous, white brown or green insulator incl one galvanized mild steel spindle, two galvanised iron washer and one galvanized iron nut of size 100mm height and 65mm dia for 1100 Volts complete all as specified and directed by the Engr-in-charge.
Supply and Fix in replacement Shackle type porcelain, vitreous, brown or green insulator 1100 volts working pressure, 75mm high and 90mm dia with and including galvanised mild steel straps, washer, insulator bolts 12mm dia, and nuts complete after removing unserviceable item all as specified and directed by the Engr-in-charge.
M&L for loop type insulator, vitreous porcelain white, brown or green large size (65 x 90mm), clearance of hole 16mm complete all as specified and directed by Engr-in-Charge.
M&L for Stay Assembly complete with Accessories as shown in electrical plate No 1 for 16mm dia of stay rod, 180 cm long complete all as specified and directed by Engineer-in-Charge. Note : Earth work shall be measured and paid for seperately.
S&F in replacement Cross arm bracing, supports clamps and backplated fabricated from structral steel section including nuts, bolts ,washers, welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge.
M&L for galvanised stay strand of size 7/4mm complete all as specified and directed by Engr-in-Charge.
S & F of gaurding wire ,cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia
M&L for line separators of LT OH lines with nut, bolts & washers straight type fixed at a point as directed and suitable for 4 wire complete all as specified and directed by Engr-in-Charge.
Supply and laying in repairs synthetic Insulating Mat of size 2m X 1m and 12mm thick for 11000 Volts made from synthetic insulating material, free from any insertions leading to detoriation of insulating properties. Note : The upper surface should have small aberration (Rough Surface) with out edges to avoid slippery effects.The mat should be fire retardant & self extiguishing complete all as specified and directed by Engr-in-Charge.
Dismantling old change over of any size and Supply and fixing Manual change over switch TPN porcelain base 125 Amps 415 volt Make : Havell's
Dismantling old change over of any size and Supply and fixing Manual change over switch TPN porcelain base 200 Amps 415 volt Make : Havell's
Dismantalling old MCCB of any size and fixing new MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
Dismantalling old MCCB of any size and fixing new MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
Dismantalling old MCCB of any size and fixing new MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x60mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip of size 32 x 6 mm thick by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
M&L for looping box made out of mild steel of size 300 x 250 x 150mm, 1.6mm thick with locking arrangement and rubber gasket including suitable aluminum bus bar of size 25 x 3mm for four pole fixed on porcelain insulator and MCB 16 Amps - 01 No including two coat of aluminum paint over a coat of red oxide primer and fixed with suitable clamp, nut and bolt complete all as specified and directed by Engr-in-Charge.
Supply and fixing Aluminium bus bar chamber 200 Amp capacity 4 strips not less than 600 mm long, outdoor type including one MCCB of 160 Amps 4 Pole as incommer with locking arangement, grouting in pcc 1:3:6 and connecting with UG XLPE cable with suitable copper thimbles complete.
Supply and fixing Aluminium bus bar chamber 200 Amp capacity 4 strips not less than 600 mm long, outdoor type including one MCCB of 250 Amps 4 Pole as incommer with locking arangement, grouting in pcc 1:3:6 and connecting with UG XLPE cable with suitable copper thimbles complete.
Supply and erecting and fixing in proper position steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.00metres long) Make: Advance steel tube, National tubing co, Mahindra industries, sohan lal and sons,Sidhartha all as specified and as directed. Note: (i) Excavation ,earth work and PCC shall be measured and paid separately. (ii) Painting will be measured and paid seperatelyunder relevent item.
Material & Labour for PCC (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole/stay and filling of mass concrete including providing necessary form work complete all as specified and as directed by the Engineer-in-charge
Material & Labour for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in coping of pole including providing necessary form work complete all as specified and as directed by the Engineer-in-charge
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed by Engineer-in-Charge.
Returing, filling in incl spreading, levelling watering and well remming in layers n.exc 25cm width, Complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point Completed all as specified and diercted by Engineer-in-Charge.
Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and directed by Engineer-in-Charge.
M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm Complete all as specified and directed by Engineer-in-Charge.
Supply and laying GI pipe light grade 40 mm bore including all type fitting such as bends, elbows, tee etc fixed on walls/to poles/laid in trenches as cable protection.
Supply and laying GI pipe light grade 50 mm bore including all type fitting such as bends, elbows, tee etc fixed on walls/to poles/laid in trenches as cable protection.
Deduct Schedule of Credit of Rs (-) 118500.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item being a firm amount.
EESSI
Ms Salaria Builders
RND ENGINEERS & CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .