Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.0 LAccepted-AOC | ₹11.0 L Quoted ₹11.3 L | 1 | Accepted-AOC ACCEPTED BEING L-1 |
| 2 | 2₹11.8 L+₹49,966.73 (4.44%)Rejected-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | ₹11.8 L+₹49,966.73 (4.44%) | 2 | Rejected-AOC REJECTED NOT BEING L-1 |
| 3 | 3₹11.9 L+₹63,127.23 (5.60%)Rejected-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹11.9 L+₹63,127.23 (5.60%) | 3 | Rejected-AOC REJECTED NOT BEING L-1 |
| 4 | 4₹12.0 L+₹77,976.23 (6.92%)Rejected-AOC | ₹12.0 L+₹77,976.23 (6.92%) | 4 | Rejected-AOC REJECTED NOT BEING L-1 |
| 5 | 5₹12.7 L+₹1.4 L (12.7%)Rejected-AOC 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹12.7 L+₹1.4 L (12.7%) | 5 | Rejected-AOC REJECTED NOT BEING L-1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
26 Jun 2025, 6:00 pmClosed
CWE YOL
HEADQUARTERS COMMANDER WORKS ENGINEER YOL
REPAIR AND MAINTENANCE AND IMPROVEMENT OF HT OH LINES AND CABLES, SWITCH GEAR, PROTECTION SYSTEM, CALIBRATION OF RELAYS AND OTHER CONNECTED WORK AT ELECTRIC INSTALLATION DALHOUSIE CANTT
2025_MES_711305_1
CWE/Y-41/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
DALHOUSIE
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
AGE (I) DALHOUSIE
₹30,000
Yes
14 Jul 2025
29 May 2025
3 Jul 2025
29 May 2025
26 Jun 2025
12 Jun 2025
Amount
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in including spreading leveling, watering and well ramming in layers n. exc 25cm, all as specified.
Removal of excavated material to be distance n.exc 50 metres and depositing where directed at a level n.exc 1.5 metres high from the starting point, all as specified.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
Un-reinforced precast concrete cable cover, class HV, Type 2, with peak, size 450mmx l80mm x 40mm for laying in trenches for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified.
Plain cement concrete 1:2:4 ( nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar ands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork where required complete all as specified and directed.
XLPE HT insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed), grade cross sectional area 95 sqmm 3 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing and taking out old unservicable cable, cable covers complete all as specified and directed. Note:- High Voltage test to be conducted at site with suitable voltage before and after laying of HT cable and rerading shall be reading shall be recorded jointly and test report to be submitted in triplicate to Engr-in-charge. The cost of the same shall be deemed to be included in the unit rate quoted above.
Renewal of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 25x20cm size, complete all as specified.
Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 80mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed.
Cutting/ trimming of tree branches clearing 5 metres horizontal and 5 metres vertical distance from both sides of HT conductor including removing branches from site, complete all as specified & directed. Note:- (i) Clearing branches from both sides of conductor in between two consequtive poles shall be considered as one span irrespective of distance between poles. (ii) Cost of T&P required for cutting and removing branches shall be deemed to be included in rate quoted by bidder.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sqmm to 120sqmm including complete all as specified and as directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120-150 sqmm including cutting and removing existing unserviceable joint, all as specified and as directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm including cutting and removing existing unserviceable joint, all as specified and as directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 150 sqmm including cutting and removing existing unserviceable joint, all as specified and as directed.
Painting to four pole structure made out of steel tubular HT poles, 11m long including cross arms, channels, angle iron support, bracings, clamps, XPM jalli etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed.
Painting to two pole structure made out of steel tubular HT poles, 11m long including cross arms, channels, angle iron support, bracings, clamps, XPM jalli etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed.
M&L for Do fuse Element stranded silver/Tin coated copper wire soldered joint with ferrule and fire resistant tube type rating 2.5 to 15 Amps complete all as specified.
- ditto- as per srl item No. 17, but rating 20 Amps.
- ditto- as per srl item No. 17, but rating 25 Amps.
Renewal of pin type insulator porcelain, vitreous, white/brown or green including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm dia and 150mm height for working pressure 11000 volts grade includng taking down existing insulators and removing from site, complete all as specified.
All as per Srl Item No 20 above but post type insulator includng taking down existing insulators and removing from site complete all as specified and directed.
Renewal of disc type insulator, 145 mm height 255 mm dia suitable for 11000 volts HT grade porcelain vitreous white,brown or green including galvanized mild steel sectional straps 38X5mm, insulator bolts dia 20mm, washers and nuts includng taking down existing insulators and removing from site complete all as specified and directed.
Overhauling i.e greasing, cleaning of GOD and adjustment of its operation complete all as specified and directed by Engineer-in-Charge.
Fixed type top contact for DO fuse units for 11 KV in replacement complete all as specified and directed. Make:- Pactil/ MEI/ ATLAS
Fixed type bottom contact for DO fuse units for 11 KV in replacement complete all as specified and directed. Make:- Pactil/ MEI/ ATLAS
S&F following spares of vertical type GOD 11 KV grade, 200 Amps rating of make - M/s Pactil/ ATLAS/ MEI in position as in repairs including testing after repairs:-
Male contact
Female contact
Tinned copper flexible jumper
MS Jumper carrier
Back connector plate
Supply and replace of maitenance free battery of battery bank rating of overall 24 Volts DC (12 Nos each of 2 Volts) 125AH, any other parts etc., as required at site, complete testing all as directed by Engineer-in-Charge.
Air break, gang operated with 09 Nos insulators outdoor type, Triple pole mechanically operated, suitable for vertcal installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 m above GL complete confirming to IS -1318 of 1972 rated voltage 11 KV & for current rating 200 Amp complete all as specified and directed.
Disconnecting HT 11 KV grade XLPE cable of any size from structure/pole/transformer for finding fault and its location including cutting faulty cable to facilitate joint and testing remaining part of cable for any further fault using cable fault locating equipment including bringing approved cable fault locating equipment & to be taken back after finding fault is over all complete as specified and directed. Note : The quoted rate shall include for earth work. Joints shall be measured and paid for seperately
Servicing of 11 KV HT VCB and taking out trolley and greasing/ servicing of all moving parts , cleaning/ tightening of all electric contact including Calibration of digital/IDMT protective relays of 11 KV Panel (OCB/VCB's) Testing of 11 KV CONTROL & RELAY PANEL Includes Main Protection Relay,Back up protection (O/C & E/F relay for all features like Inverse O/C,Inverse E/F, High Set O/C, High Set E, F etc. Along with pick up & dropoff volts for all auxiliary relays like Master trip , Trip circuit supervision,Checking and tightening of wiring connections at all terminals points/ at relays, inspecting wirings for any open circuit, short circuit & damaged inulations. and preparition inpection data sheet of existing feeder re-programming input data into relays (OCHS, EFHS, OCLS, EFLS, CTR, TDS etc) complete testing by injecting current in CT primary and measure secondary current at 11 KV, control and relay panel for metering, protection relay plug settings intended in service through current injection in CT primary and ratio including complete polarity test complete all as specified and directed. Note : 1. Generator back up required during testing shall be arranged by contractor for which rate are deemed to be included in item rate 2. All testing shall be carried out in presence of Engr-in charge and test certificate shall be submitted in duplicate duly signed by contractor
Replacement of defective relays with digital protective relays 3 phase over current and earth fault (04 NO - Programmable i.e. 2NO + 2NC programmable) with high set, CT rating 5A, Aux. supply 24 -110V, TMS range 0.01 - 1.6, 35mm LCD Display, including initial setting of parameters as per existing load of feeder/transformer, in replacement against ser item 1 here in before in existing panel including addition/alteration as required at site, testing complete all as directed by Engineer-in-Charge. Make : as per sample or equivelent as approved by AGE (I).
Renewal of lightning arresters (Set of three) expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11000 volts including taking out old unservicable arrester and removing from site complete all as specified and directed.
Dehydration, filtration, heating and refilling of old transformers oil after testing the same for dielectric strenghth not less than 45 KV (RMS). Note:- (a) Dehydration and filtration can be carried out at site by dehydration machine otherwise the same shall be got done from the manufacturing workshop of transformers complete all as specified.(b) Contractor shall ensure no wastage of transformer oil.(c) Safety of transformer during filteration shall solely be the responsibility of contractor and any damaged caused to transformer during the operation of filteration shall be made good by contractor at his own and no claim for any expanditure on this account shall be entertained during execution of work or later stage.(d) Contractor shall ensure that the conservator tank are full before starting the dehyderation.(e) Testing of transformer oil for BDV and acidity as per IE rules all as specified and directed.(f) Test results shall be submitted to Engineer-in-Charge equipment wise.
Transformer oil at various location at site as directed, transformer oil Confirming to IS: 335 having dielectric strength not less than 60 KV complete including centrifuging of oil (if required) up to getting dielectric strength near 60 KV all as specified and directed by the Engineer-in-Charge Make:- Power oil & Equivalent approved by GE Note :(i) Transformer oil shall be supply only in sealed barrels (ii) Item Rate includes transportation & T&P reqiuired
Disconnecting/dismantling in position of 11 KV distribution transformers 63 KVA to 100 KVA capacity for any type of leakage/defect at LT/HT bushing, gasket, drain plug etc., after disconnecting of electric supply and earth connections, Transporting to workshop/ factory for repair , drain out transformer oil and keeping in close containers for re-use, lifting/removing of top cover of transformer if it requires, re-assembling of transformer with S&F of new gasket set assembly, replacement of nuts, bolts and washers, as required at site, re filling of Transformer oil, complete after electric connections and testing all as specified and directed by Engr-in-Charge. Note :- (i) If retrieved transformer oil's di-electric strength is very less, then it will be replaced with new one in relevent items.as directed by engineer encharge. (ii) If any items like winding of HT coil,Reconditioning of LT coil,spares like breather ,silica jel shall be measured in approriate item for smooth functioning of transformer including general , the cost of the same will be deemed to be included in the unit rates. (iii) Any minor item like nut ,bolt are included in the item rate (iv) Transportation to workshop and back to site /and required T&P like crane etc are to be arranged by contractor rate for which is dimmed to be included in the item
Rewinding of HT coil of transformer with super enameled double paper covered copper winding wire of existing size and Nos of turns alongwith insulating materials like latheorised paper insulations cotton, tape/empire tape, wooden block packing and PVC sleeves soldering and varnishing with insulating varnish,de moisterizing , heating , drying etc including primary testing ,ratio testing,no load testing,core bolt insulation testing complete .Note : Rewinding and testing of transformer to be carried out through approved firm.
HT bushing out door/In door type 11 KV, HV made up of free machining brass rod complete with neoprene seal rings, locking nuts as per IS 3347/1967 complete with porcelain bushing and gasket etc complete with current rating up to 250 Amps , complete all as specified.
LT bush rod out door/In door type 1.1 KV L.V made up of free machining brass rod complete with neoprene seal ring, locking nuts and other accessories of working current rating 250 Amps 20mm as per IS 3347/1967, complete all as specified.
LT bush rod out door/In door type 1.1 KV L.V made up of free machining brass rod complete with neoprene seal ring, locking nuts and other accessories of working current rating 400 Amps 25mm as per IS 3347/1967 , complete all as specified.
Disconnecting HT/ LT and earth termination connections from Trolley Mounted Transformer (400 KVA Cap.) and towing the same to a location, within 5 KMs, as directed by Engr-in-Charge including M&L for making of HT/ LT and earth termination connections of the Trolley Mounted Transformer to the existing electric distribution system in Indoor/Outdoor Substation complete all as specified and directed by Engr-in-Charge. Note : (i).Trolley Mounted transformer will be issued to contractor by MES however Contractor has to make his own arrangements of towing vehicle. (ii) The rate also includes disconnecting of HT/ LT and earth termination connections of Trolley Mounted Transformer and towing the same to a location as directed by Engr-in-Charge.
Breather silica gel container of suitable for 11 Kv for upto 100 KVA distribution transformer Capacity, complete all as specified.
Breather silica gel container of suitable for 11 Kv for upto 125 TO 250 KVA distribution transformer Capacity, complete all as specified.
M & L for Breather silica gel container of suitable for 11 Kv for upto 315 TO 400 KVA distribution transformer Capacity, complete all as specified.
Replacement of digital LCD display, 3 phase ammeter suitable for installation in HT VCB panel to measure current in 11 KV system through current transformer having CT ratio 100/5A designed as per IS flush mounting IP 52 ammeter 0-100 Amp accuracy class 1.0 of size 96x96mm, complete all as specified. Make : Secure/Siemens / AE
Replacement of digital LCD display, 3 phase voltmeter suitable for installation in HT VCB panel to measure current in 11 KV system through potential transformer having PT ratio 10100/110V designed as per IS flush mounting IP 52 voltmeter 0-11000 volts accuracy class 1.0 of size 96x96mm, complete all as specified. Make : Secure/Siemens / AE
Replacement of vaccum interrupter bottle as per site requirement for 11 KV indoor VCB 630 Amps rated voltage 12 KV , rated short circut breaking capacity 25KA/ 3 sec conforming to IS 131188/IEC 62271-100, complete all as specified. Make : Schneider/Siemens/Crompton
Replacement of panel mounted solid state LED indicator lamp 0.5 watt230 V/110V AC/DC flicker free IP 65 of any colour suitable for mounting on 11 KV HT VCB conforming to IS 60947-5-1/IS 13947, complete all as specified. Make : Secure/Siemens / AE
Replacement of resin case/ epoxy molded single phase PT of ration 11000/110V, burden 15 VA or as required , 50 Hz , having insulation level 12KV accuracy class 1.0 suitable for 11 KV indoor VCB suitable as per IS16227 ( Part-I) 2016, complete all as specified. Make : Schneider/Siemens/ABB / L&T
Replacement of resin case/ epoxy molded single phase indoor resin cast CT of ratio 100/5A accuracy class 1.0/ 5P10, burden 15 VA-having insulation level 12KV suitable for 11 KV indoor VCB suitable as per IS16227 ( Part-I) 2016, complete all as specified. Make : Schneider/Siemens/ABB / L&T
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25mm x 4mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Earthing complete with copper earth plate 600x600x3.15mm thick electrode thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to 20x3 mm copper strip (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 40 mm bore including provn of concrete pit in plain cement concrete M-15 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Replacement for Earth continuity conductor or main earthing lead fixed to walls on batten or recess or chases or buried in ground or drawn in conduit/pipes or fixed to poles or any other indicated situation for loop earthing etc as required, 25x4mm galvanised iron strip, all as specified.
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 25 of tender doucments.
M/S SHRI RAM BUILDERS (BID ID -3335407)
M/s Shakti Electric Works (BID ID -3329447)
M/S MALHI CONSTRUCTIONS (BID ID -3337644)
malghotra construction co (BID ID -3338167)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .