Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.4 L+₹1.4 L (5.91%)Rejected-Finance | L2 | Rejected-Finance Not being lowest bidder. | |
| 3 | L3₹26.4 L+₹2.4 L (9.96%)Rejected-Finance | L3 | Rejected-Finance Not being lowest bidder. | |
| 4 | L4₹29.5 L+₹5.5 L (22.9%)Rejected-Finance | L4 | Rejected-Finance Not being lowest bidder. | |
| 5 | L5₹34.9 L+₹10.9 L (45.6%)Rejected-Finance | L5 | Rejected-Finance Not being lowest bidder. |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
26 Oct 2020, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT/REPLACEMENT OF WATER SUPPLY DISTRIBUTION PIPE LINE AND REPAIR/MAINT OF DG SETS OF VARIOUS CAPACITY AND GEYSERS, SOLAR WATER HEATER IN THE AREA OF AGE EM (HOSP) UNDER GE E/M LUCKNOW
2020_MES_380262_1
GE/EM/LKO/HOSP/T-52 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class D or above category a (ii) and b (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹88,000
Yes
17 Dec 2020
23 Sept 2020
28 Oct 2020
23 Sept 2020
26 Oct 2020
7 Oct 2020
Amount
Servicing of DG sets including replacement of fuel filters,oil filters,air filter element,changing oil,cleaning fuel lines,checking leakage and repairing it,replacement of exhaust main fold gasket etc complete all as specified and directed by Engineer-in-Charge all as per manufacturer/authorised service centre for the 15 KVA capicity of DG sets :- Note. (i) Rate quoted shall be included attending any fault ( Start /Stop) or other defects on emergency basis by technecian for the entire period of contract .No extra cost will be paid to the contractor for the same.
All as per item No 1 above but 30 KVA
All as per item No 1 above but 55 KVA
All as per item No 1 above but 75 KVA
All as per item No 1 above but 100 KVA
All as per item No 1 above but 125 KVA
All as per item No 1 above but 160 KVA
All as per item No 1 above but 200 kVA
All as per item No 1 above but 400 kVA
All as per item No 1 above but 625 KVA
Servicing of AMF panel with neecessary testing including replacement of unserviceable parts complete all as specified and directed by Engineer-in-Charge all as per manufacturer/authorised service centre :- Note. (i) Rate quoted shall be included attending any fault ( Start /Stop) or other defects on emergency basis of technecian for the entire period of contract .No extra cost will be paid to the contractor for the same.
Supply only failure timer as per existing make spares in replacement/ fixing at site for AMF panels complete all as specified and directed by Engineer-in-Charge
Auxillary contactor 3 phases suitable for AMF panel as per existing make complete all as specified and directed by Engineer-in-Charge
NC/NO relay complete as per existing make complete all as specified and directed by Engineer-in-Charge
Under Voltage Relay as per existing make complete all as specified and directed by Engineer-in-Charge
Time delay Relay as per existing make complete all as specified and directed by Engineer-in-Charge
C T Coil of 5/150 for 125 Kva DG set as per existing make complete all as specified and directed by Engineer-in-Charge
C T Coil of 5/50 for 63to 82.5 Kva DG set as per existing make complete all as specified and directed by Engineer-in-Charge
Battary Charger in AMF Panel complete all as specified and directed by Engineer-in-Charge
Controller for 82.5 Kva to 200 Kva as per existing make complete all as specified and directed by Engineer-in-Charge
VMR 3 phases for 82.5 kva to 125 Kva as per existing make complete all as specified and directed by Engineer-in-Charge
Contractor Relay for 82.5 Kva to 200 Kva complete all as specified and directed by Engineer-in-Charge
HRC fuse complete all as specified and directed by Engineer-in-Charge
Fuse base for DIN type fuse links up to 200 amps complete all as specified and directed by Engineer-in-Charge
HRC fuse links 125/160/200 Amp complete all as specified and directed by Engineer-in-Charge
M & L for up to 125 KVA DG set, Rewinding of main armature, main field, exiter armature and exiter field with super enamelled copper winding wire of existing size and gauge and adequate number of turns including varnishing including taking down unservicable rewinding material complete all as specified and directed by Engineer-in-Charge
M & L for up to 160 KVA to 200 KVA DG set, Rewinding of main armature, main field, exiter armature and exiter field with super enamelled copper winding wire of existing size and gauge and adequate number of turns including varnishing including taking down unservicable rewinding material complete all as specified and directed by Engineer-in-Charge
M & L for 320 DG set, Rewinding of main armature, main field, exiter armature and exiter field with super enamelled copper winding wire of existing size and gauge and adequate number of turns including varnishing including taking down unservicable rewinding material complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs Contactor 4 pole mcx 43 , 415 volts, complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs Contactor 4 pole MCX 41 , 415 volts, complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs Contactor 4 pole MCX 34 , 415 volts, complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs Contactor 4 pole MCX 23 , 415 volts, complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs Contactor 4 pole MCX 13 , 415 volts, complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs Contactor 4 pole MCX 04 415 volts, complete all as specified and directed by Engineer-in-Charge
S & F Offload change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and directed by Engineer-in-Charge
S & F On load change over switch, 63 Amps, 415 volts, 4 pole side handle type in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all as specified and directed by Engineer-in-Charge
S & F Off load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including dismantling of existing change over switch, complete all as specified and directed by Engineer-in-Charge
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 125 AMPS complete all as specified and directed by Engineer-in-Charge
MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 160 AMPS complete all as specified and directed by Engineer-in-Charge
MCCBs four pole 25 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 200 AMPS complete all as specified and directed by Engineer-in-Charge
MCCBs four pole 25 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 250 AMPS complete all as specified and directed by Engineer-in-Charge
MCCBs four pole 25 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 400 AMPS complete all as specified and directed by Engineer-in-Charge
Earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 32x6mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 5 of SSR Part-I and testing ,including dismanteling of old unserviceable earthing , complete all as specified and as directed by Engineer-in-Charge. Note : (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 1.00 metre away from earth.
Removing of lubricating oil from chamber and oil filter chamber of the DG set and cleaning of oil chamber & filter chamber thoroughly to remove all types of deposites and supply & filling of new lubricant oil SAE 20 W/40 W at required level complete all as specified and directed by Engineer-in-Charge. Make: Indian oil /BPL).
Draining out old used water with coolent from the radiator of Gen Set (Kirloskar, Cummins) after disconnection the water connecting pipe, descaling, cleaning properly with high pressure wash to remove greasy substances from water tubes, tank and outer fins remove greasy substances from water tubes, tank and outer fins and refixing the same after servicing complete and renewal of coolant solution complete all as specified and directed by Engineer-in-Charge (Note :- Water coolant of approved make shall be measured and paid separately under respectative items.)
Supply and filling coolant for DG set as per DG set manufacturer's recommendation complete all as specified and directed by Engineer-in-Charge
Supply, fixing, connecting, testing battery, 12 volts, 150 AH with lead acid terminals, indication of charging position and terminals for connection etc including initial charging of Battery complete all as specified and directed by Engineer-in-Charge. (Make EXIDE / AMRON) including disconnection of exiting unserviceable battery and removal to store of AGE (Hosp).
Supply, fixing, connecting, testing battery, 12 volts, 180 AH with lead acid terminals, indication of charging position and terminals for connection etc including initial charging of Battery complete all as specified and directed by Engineer-in-Charge. (Make EXIDE / AMRON) including disconnection exiting unserviceable battery and removal to store of AGE (Hosp).
M&L for renewal of battery terminal heavy duty made out of brass suitable for 12 V lead acid battery complete all as specified and directed by Engineer-in-Charge
Supply & filling distilled water in batteries as required at various DG Set installations complete all as specified and directed by Engineer-in-Charge
Replacement of burnt battery lead heavy duty with & including 2.0 metre long PVC insulated multistranded copper conductor wire , consisiting with suitable size of lugs and heavy duty terminal complete all as specified and directed by Engineer-in-Charge
Supply and fixing crocodile clip for battery chargers of required size complete all as specified and directed by Engineer-in-Charge
Replacement of RPM/Hour meter on DG set instruement panel including RPM wire / cable and other accessories as required complete all as specified and directed by Engineer-in-Charge
Replacement of oil pressure gauge including pressure gauge sensor complete all as specified and directed by Engineer-in-Charge. (Make:- Siemens / Yankay/ Pricol)
Dismantling the alternator of 15 KVA to 625 KVA DG sets from coupling and opening the stator & rotor including cleaning of dust from windings for proper ventilation, renewal of carbon brushes with brush holder and assembling the rotor & stator complete including applying suitable greasing & oil off bearing & moving parts complete all as specified and directed by Engineer-in-Charge
Supply of cotton waste for cleaning of DG set and installation complete all as specified and directed by Engineer-in-Charge
Dismantling / taking down the governor and injector assembly including all connected parts from DG set 160 KVA to 625 KVA and over hauling calibration of injector assembly,fuel supply system,electronic governor etc(through authorised dealer of O.E.M) complete including renewal of wornout parts such as copper gasket, injector nozzle to maintain the desired fuel supply and provide fluctuation free output complete all as specified and directed by Engineer-in-Charge
Replacement of starting switch / ignition switch / push button of any type with key guard necessary wiring complete all as specified and directed by Engineer-in-Charge
Taking down and Servicing and overhauling of self starter 24 Volts by replacement of carbon bushes, holder assembly, varnishing in field coil as required and refixing in position and testing complete all as specified and directed by Engineer-in-Charge
Disconnecting of unsv/burnt self starter and supply and installation of self starter 24 Volts suitable for DG sets of capacity 125 KVA to 320 KVA complete all as specified and directed by Engineer-in-Charge. Make - LUCAL/Autolex .
M & L for servicing of incinarator installed at command hospital including Nozzle, spark plug cleaning of chamber, burner, hose pipe etc complete all as specified and directed by Engineer in Charge .
M & L for Painting of DG Set outer body with acreylic paint same coloure as per existing complete all as specified and directed by Engineer in Charge .
Overhauling, repairing, reassembling, refixing, re-installation of water heaters / Geysers to their original position, making all necessary water & electric connections and testing complete all as specified and directed by Engineer-in-Charge Note for item No. 02 :- (i) Labour for assembling of all old/ serviceable and new parts to make the geyser in serviceable conditionshall include in this items. (ii) Parts renewed shall be measured and paid spearately.
Supply & Fixing heating element 1.5 KW (ISI marked) suitable for geyser of 25 litres capacity, horizontal or vertical type any make complete all as specified and directed by Engineer-in-Charge
Supply & Fixing heating element 2 KW (ISI marked) suitable for geyser of 50 litres capacity, horizontal or vertical type any make complete all as specified and directed by Engineer-in-Charge
Supply & Fixing heating element 4 KW (ISI marked) suitable for Suitable for solar water heater up to 100 LPD capacity, horizontal or vertical type any make complete all as specified and directed by Engineer-in-Charge
Supply & Fixing thermostat, minimum 300 mm long, suitable for any make & type of geyser 25 / 50 litres capacity horizontal or vertical type complete all as specified and directed by Engineer-in-Charge
Supply & Fixing indicating lamp for geysers of any type make & capacity complete all as specified and directed by Engineer-in-Charge
M&L for painting old surfaces of geysers of 25 litres capacity of any make with one coat of paint of approved shade or tint after necessary preparation to surfaces and writing of MES Nos as approved size of letter complete all as specified and directed by Engineer-in-Charge
S&F of PVC connection 15 mm dia with 2 Nos brass coupling, nuts from geyser inlet / outlet, 40 cm length suitable for 15 mm bore GI pipe complete all as specified and directed by Engineer-in-Charge
Supply, installation testing and commissioning of storage type water heater 25 ltrs capacity vertical mounting type complete made out of CRCA outer body, copper storage tank, heating element,thermostat,thermal cut out, glass wool etc. complete including making necessary electrical connections with suitable size copper multistranded cable complete all as specified and directed by Engineer-in-Charge
S&F PVC insulated and PVC sheathed 3 core copper conductor flexible round cable size 23 / 0.0076 complete all as specified and directed by Engineer-in-Charge
S&F of chromium plated stop cock with brass spindle & with crutch or butterfly handle screwed down high pressure suitable for 15 mm bore GI tubing complete all as specified and directed by Engineer-in-Charge
S&F Bib taps, cast copper alloy with crutch handle, screwed for 15 mm bore dia. Iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge
S&F pressure releasing valve ISI marked complete all as specified and directed by Engineer-in-Charge
Supply and fixing of plug top polycarbonate 3 pin, 16 Amps (Cat No. 38637 of Anchor or equivalent of other specified a make) complete all as specified and directed by Engineer-in-Charge
Supply & fixing in repair SPN sheet Metal enclosure with socket plug top and MCBs with 2 pin and earth plyg and socket rated 20 Amps capacity including single pole MCB of 20 Amps complete all as specified and directed by Engineer-in-Charge
S & F MCB SP, 6 to 32 Amps, B Series ,240 Volts complete all as specified and directed by Engineer-in-Charge (Cat No. 6032 31 to 6032 37 of legrand or equivalent of other specified make).
S&F GI nipple, 15 mm bore, medium grade upto 50 mm length complete all as specified and directed by Engineer-in-Charge
S&F GI pipe, 15 mm bore, medium grade mm length complete all as specified and directed by Engineer-in-Charge
Supply, installing, testing & Comissioning of Solar water system with (Flat plate Collector) based on indirect transfer of heat of capacity 200 LPD with electrical bckup and fixing of Make up water tank including iron staging of suitable complete all as specified and directed by Engineer-in-Charge
M&L for mild steel cross arms, bracings supports, clamps and back plates fabricated from structural steel sections, channel including nuts, bolts, washers welding, bending cold or not, drilling holes for bolts in any shape or size and up to size – 1.5 x 1.0 x 0.50 mtr incl PCC 1:2:4 using 20 mm stone agregrate up to 50 cm deep foundation works as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge
S&F gun metal glob or gate valve with iron wheel head screwed both end for iron pipe of 25 mm dia bore Size complete all as specified and directed by Engineer-in-Charge
All as per item No 83 above but 20 mm dia bore
All as per item No 83 above but 15 mm dia bore
Rotational moulded PVC, tripple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve complete all as specified and directed by Engineer-in- Charge.
Sub main wiring (concealed type ) with two single core 4 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface in and including taking down old unservicable sub main wiring , complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4 Sqmm ,1 run of PVC conduit & 1 run of 4 Sqmm cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
Switch piano flush type of polycarbonate , SP, 16/20 Amps, one way ,complete all as specified and as directed by Engineer-in- Charge.
Socket out let of polycarbonate 6 pin, 20 Amps ,complete all as specified and as directed by Engineer-in- Charge.
Supply ,laying,jointing , commissioning & testing of GI pipe medium grade with all fittings and fixtures laid in trenches or floor /fixed to wall / ceiling in and including taking down of old unservicable pipe with all fittings, complete all as specified and directed by Engineer-in-Charge of 15 mm bore sizes : Notes: (i) Fittings & specials as required shall be provided by the contractor. Contractor's rate shall deemed to be included the cost of fittings provided. (ii) Excavation & earth work shall be measued paid seperately) of the following sizes
All as per item No 90 above but 20 mm bore.
All as per item No 90 above but 25mm bore.
All as per item No 90 above but 40mm bore.
All as per item No 90 above but 50mm bore.
Supply ,laying,jointing , commissioning & testing of cast iron pipes spigot and socketed ends centrifugally casted class LA 'ISI marked' in any length laid in trenches in and including taking out of existing unserviceable CI pipe , complete all as specified and directed by Engineer-in-Charge of 80 mm nominal bore sizes : Notes- (i) Rubber gas kit joints and CI specials / fitting shall be measured and paid separately. (ii) Excavation & earthwork shall be measured & paid separately under appropriate item of this BOQ.
All as per item No 95 above but 100 mm nominal bore.
All as per item No 95 above but 150 mm nominal bore.
Run lead joints suitable for spigot & socketed CI Pipe and caulking the joints properly for avoiding leakage etc including burning out lead joint in position, removing & recovering old lead & necessary earth work excavation as required and fixed as in repair for new/old pipe lines of fittings for the 80 mm bore size complete all as specified and directed by Engineer-in-Charge.
All as per item No 98 above but 100 mm bore.
All as per item No 98 above but 150 mm bore.
Supply ,laying,jointing and testing of sluice valve of size 80 mm bore 'ISI marked' both ends flanged and drilled cast iron body class PN-1.6 conforming to IS-14846/2000 complete with gun metal spindle including necessary nut bolts etc in and including taking down of old unservicable sluice valve with all fittings,complete all as specified and directed by Engineer-in-Charge of 80 mm bore dia sizes : Note: For those sluice valves which are fixed with pillar of over head tank work involve such as breaking of RCC/lead flange joints will be deemed to be included in the quoted rates, contractor will also repair the demaged floor etc.to match with existing and Joints shall be measured & paid seperately.
All as per item No 101 above but 100 mm bore.
All as per item No 101 above but 150 mm bore.
Gun metal glove or gate valve, Class -1, ISI marked with iron wheel head, screwed both ends for iron pipe in and including taking up or down old unservicable gate valve , complete all as specified and directed by Engineer-in-Charge of 50 mm bore sizes : Note : Excavation & earthwork shall be measured & paid separately under appropriate item of this BOQ.
Cutting of road (in hard/ dense soil ) for laying pipe line or repair to pipes / lead joints etc .of any size upto 01 mtr. depth and getting out incluiding foRunning Metreing bottom surface to required level and making good the road as per existing , complete all as specified and directed by Engineer-in-Charge.
Drilling and tapping cast iron/ mild steel water mains (in position ) for branch connections including supply of GI nipple of medium grade pipe,150mm long of 15 mm bore sizes, complete all as specified and directed by Engineer-in-Charge.
All as per item No 106 above but 20 mm bore.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for laying /taking out water supply pipe line etc., and getting out in Soft/ Loose soil for foundation, trench of pipes etc including trimming the sides and forming bottom surfaces to required levels, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Construction of valves pit chamber of size 900x900x900mm (internal dimension), using PCC (1:4:8) 40 mm graded stone aggregate for foundation 15 cm thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20 mm graded agregate for grouting MS frame including 4 mm thick MS top sheet cover with locking arrangement including 50 mm pad lock with double key arrangement, MS frame out of 40 x 40 x 5 mm thick angle iron including paintaing of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers finishing coat including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs and including demolition/dismantling of existing cracked valve pit chamber ,complete all as specified and directed by Engineer-in-Charge.
All as per item No. 111 above but 1200x1200x1000 mm.
M & L For attending complaint of water pipe line leakage/brolen of size upto 50 mm removing broken/ damage/rusted pipe line then after repair/maint /replacement of pipe and refixing same pipe including excavation work returnig filling same with necessary T &P jointig mtrl with gasket/lead socket all as required at the site complete all as specified and directed by Engineer-in-Charge
Ajanta Associates
M K Engineers and Contractors
PUMA POWER
M/S J J ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .