Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.1 CrQualified Make: TATA GREEN BATTERIES
Model: Tata Green 200H52 169 2 HIND MOTOR STORE NETAJI SUBHASH MARG RAI MARKET AMBALA HARYANA 133001 | AMBALA | HARYANA | 133001 | Make: TATA GREEN BATTERIES
Model: Tata Green 200H52 | ₹4.1 Cr | L1 | Qualified |
| 2 | Disqualified Make: EXIDE
Model: EXIDE MODEL MHD 2000 0 0 ICHAPUR SEALDANGA SANTRAGACHI HOWRAH WEST BENGAL 711104 | HOWRAH | WEST BENGAL | 711104 | Make: EXIDE
Model: EXIDE MODEL MHD 2000 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 Aug 2018, 11:00 amClosed
Average Turn Over of Last 3 Years 214 Lakh (s) Experience with Gov. Required 3 Year (s) Lead Acid Battery ( 2639 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Lead-Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995 Lead-Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995
Lead- Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Hard Rubber
Fibre Reinforced Plastics (FRP)
Polypropylene
ABS Rated Capacity at C20 discharge (AH) 200 200
200.0 1/3 Warranty (Years) 3 Years 3 Years Battery Condition Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) 7600 * Weight of Dry Battery (Kg) shall be as per relevant IS: Specn.
corresponding Ah Yes. * No.of cells per Battery (No.) 6 Cells for 12 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab EXIDE HOUSE 59E CHOWRINGHEE ROAD
KOLKATA-700020 * Name of the Lab EXIDE INDUSTRIES LTD * Test Report No. 72291 * Test Report Date 01 APR 2018 * Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells
and for Batteries made from them for use in portable applications NA * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajeev Choudary 110010
COD DELHI Delhi Cantt 2639 90 2/3
476330
GEM/2018/B/67329
lead acid battery
90 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Average Turn Over of Last 3 Years 214 Lakh (s) Experience with Gov. Required 3 Year (s) Lead Acid Battery ( 2639 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Lead-Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995 Lead-Acid Storage Batteries for Motor Vehicles conforming to IS:7372/1995 | - | - | - |
| Lead- Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Hard Rubber | - | - | - |
| Fibre Reinforced Plastics (FRP) | - | - | - |
| Polypropylene | - | - | - |
| ABS Rated Capacity at C20 discharge (AH) 200 200 | - | - | - |
| 200.0 1/3 Warranty (Years) 3 Years 3 Years Battery Condition Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) 7600 * Weight of Dry Battery (Kg) shall be as per relevant IS: Specn. | - | - | - |
| corresponding Ah Yes. * No.of cells per Battery (No.) 6 Cells for 12 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab EXIDE HOUSE 59E CHOWRINGHEE ROAD | - | - | - |
| KOLKATA-700020 * Name of the Lab EXIDE INDUSTRIES LTD * Test Report No. 72291 * Test Report Date 01 APR 2018 * Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells | - | - | - |
| and for Batteries made from them for use in portable applications NA * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajeev Choudary 110010 | - | - | - |
| COD DELHI Delhi Cantt 2639 90 2/3 | - | - | - |
Exempted
31 Aug 2018
8 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_476330.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .