| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹48.8 L+₹3.9 L (8.59%)Rejected-AOC | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 3 | L3₹49.1 L+₹4.2 L (9.31%)Rejected-AOC 184 C 13 THURAIYUR SAMINATHAN NAGAR PERAMBALUR SALAI TIRUCHIRAPPALLI TAMIL NADU 621010 UDYAM TN 27 0052941 | TIRUCHIRAPPALLI | TAMIL NADU | 621010 | L3 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 4 | L4₹49.9 L+₹5.0 L (11.1%)Rejected-AOC | L4 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 5 | L5₹51.4 L+₹6.5 L (14.6%)Rejected-AOC | L5 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
11 Sept 2023, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
REPAIRS TO FLOORING INTERNAL WATER SUPPLY LINES REPAIRS TO JOINERIES AND INTERNAL ELECTRIFICATION OF MES OFFICE AND TEMPORARY BUILDINGS AND REPAIR MAINTENANCE TO CERTAIN FLAME PROOF LIGHTS FLAME PROOF SWIRCHES AND FLAME PROOF DBS AND MISC ITEMS INCL
2023_MES_614719_1
8304E8
Open Tender
Civil Works
Item Rate
360 days
Garrison Engineer M NAS Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹92,000
Yes
11 Oct 2023
21 Aug 2023
13 Sept 2023
21 Aug 2023
11 Sept 2023
4 Sept 2023
Amount
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed
M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. NOTE :Sheet willbe bent and shaped to match the existing roof shape as per reqd curvature/site reuirement
M & L for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. NOTE :Sheet will be bent and shaped to match the existing roof shape as per reqd curvature/site reuirement
S&F 2mm Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and as directed.
S & F flat iron wind ties for roof including securing bolts, posts and struts, including cutting tops to shape as directed, drilling holes, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe–410W Gde E-250 a quality complete all as specified and as directed
M&L Greasing of hanger track in top and bottam of steel gate /hanger shutter for trouble free operation complete all as specified and as directed
Material and labour for two coats of synthetic enamel paint over one coat of red oxide priming including preparation of new steel surfaces over 10 cm in width or girth, not otherwise described complete all as specified and as directed
Hacking out from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed
S&F Sheet glass,4 mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and as directed
Preprataion of old steel Surfaces of any description, over 10cm in width or girth,not otherwise describe one coat of synthetic enemel paint complete all as specified and as directed
Preprataion of new steel Surfaces of any description, over 10cm in width or girth,not otherwise describe one coat of synthetic enemel paint complete all as specified and as directed.
Taking down of chowkhats but with shutters (without taking off shutters from the frame ) complete all as specified and as directed .
M &L Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed
S&F power coated anodised aluminium grill of 6x6 mm bars size of opening 10 cms size mesh with alluminium channel F/U angle aluminium frame work complete all as specified and as directed .
S&F in repairs Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and as directed .
Dismentelling wall ceiling borad of any thickness including cover fillets complete all as specified and as directed .
S&F in repairs anodised aluminium snap grid frame work of size 605x605 mmfor false ceiling complete all as specified and as directed by Engr-in-charge.
Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed.
M&L for prepairtion of Surfaces of any description over 10cm girth or width, not otherwise described applying two coat of plastic aluminium paintover a coat of primer complete all as specified and directed.
S&F Door closer hydrau lically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
S & F 15 mm size Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
Disconnecting existing tank ,setting aside (or lowering if reqd ) for repairs ,cleaning etcand hoisting if required reconnecting and re fixing in position for the following capacity
Capacity exceeding 250 ltrs but not exceeding 500 ltrs
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes of any description and washing down in the manner as specified for the following capacity
Capacity exceeding 250 ltrs but not exceeding 500 ltrs
Capacity exceeding 500 ltrs but not exceeding 1000 ltrs
All as per item No 29 above but from RCC tank of capacity exceeding 1000 ltr but not exceeding 2000 ltr
S&F In repairs threaded type pvc tank covers with all fixing accessories for PVC tank for capacity 250/500/1000 ltrs fixed with screws complete all as specified and as directed
Taking up or down 15mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed
Taking up or down 20mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed .
Taking up or down 25mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed .
Taking up or down 50 mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed .
S&F Tubes, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors 15 mm complete all as specified and as directed.
S&F Tubes, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors 20 mm complete all as specified and as directed.
S&F Tubes, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors 25 mm complete all as specified and as directed.
S&F Tubes, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors 50 mm complete all as specified and as directed.
S&F 15 mm dia UPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe with all fittings complete all as specified and as directed
S&F 20mm dia UPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe with all fittings complete all as specified and as directed
S&F 25mm dia UPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe with all fittings complete all as specified and as directed
Supply & fixed in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, ISI marked, triple layered, marked embosed, hoisted and fixed in position including all fitting connecting up pipes complete all as specified and as directed
Supply & fixed in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, ISI marked, triple layered, marked embosed, hoisted and fixed in position including all fitting connecting up pipes complete all as specified and as directed.
Supply & fixed in repairs rotational moulded polyethylene water storage tanks (Rectangle shaped with closed top and fixed in loft portion of the kitchen) of 275 litres capacity, ISI marked, triple layered, marked embosed, hoisted and fixed in position including all fitting connecting up pipes complete all as specified and as directed .
Supply & fixed repairs Ball valves 15 mm dia high pressure of PTMT with epoxy coated Aluminium rod &highdensity plastic ball screwed for iron pipe minium weight 142 gms complete all as specified and as directed
Supply & fixed repairs Ball valves 20 mm dia high pressure of PTMT with epoxy coated Aluminium rod &highdensity plastic ball screwed for iron pipe minium weight 210 gms complete all as specified and as directed
Supply & fixed repairs Ball valves 20 mm dia high pressure of PTMT with epoxy coated Aluminium rod &highdensity plastic ball screwed for iron pipe minium weight 455 gms complete all as specified and as directed.
Supply & fixed repairs Ball valves 20 mm dia high pressure of PTMT with epoxy coated Aluminium rod &highdensity plastic ball screwed for iron pipe minium weight 1240 gms complete all as specified and as directed.
S&F in repairs Bib taps 15 mm , cheromium plated long body with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F in repairs Angle cock 15 mm , cheromium plated , screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and as directed
S&F in repairs pillar tap(fancy type) cast copper alloy 15mm bore screwed down high pressure chromium plated screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F in repairs Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed .
Demolition of cement concrete of any description and in any position not otherwise specifically provided for as in sunken floor and removal & rubbish of premises exc 500 m but n exc 1.5 km complete as specified and as directed .
Material and labour for 15 mm thick screed bed in CM 1:4 with WPC @ 3% by weight of cement on concrete surface complete all as specified and as directed NOTE:(WATER PROOFING COMPOUND WILL BE MEASURED AND PAID SEPARATELY)
Supply only integral water proofing liquid complete all as specified and as directed .
Material and labour for cement concrete type E-2, 1:5:10, (Using 40mm graded stone aggregates) for sunken floors filling complete all as specified and as directed
S&F in repairs PVC valveless, syphonic action type, flushing cistern, 10 ltr capacity , low level, white, with inlet, ball valve, float and handle including brackets flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern complete all as specified and as directed.
S&F in repairs of symphone single flush flushing cistern, 10 ltr capacity low level complete all as specified and directed .
Supply and fix vitreous china wash hand basin white flat back size 550x400mm excluding taps waste chain and plug and porcelain stopper but including brackets waste fitting brass chromium plated 32mm dia with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed etc PVC connections 15mm size with including PTMT nut length 300mm including Waste coupling of PTMT (Half or full threaded)(minimum weight 32 mm/40 gm/60 gm ) complete all as specified and as directed
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and as directed .
S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed
S&F in repairs Vitreous china urinal partition white of size 310x700 mm terminating about 40 cm above floor line complete all as specified and as directed .
S&F in repairs glass shelf assembly for soap tray embeded in the wall complete all as specified and as directed .
S&F in repairs Tubular towel rail, 20mm dia, D type, 60cm long between flanges etc with pair of bracket complete all as specified and as directed.
S&F Vitreous China wash down water closet pan (pedestal pattern) with Seat and cover for pedestal pan , including valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polythene of low or high density or pvc 32 mm dia,for low levwl cister Flush pipes to pedestal pan, including all joints complete all as specified and directed
PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified and as directed
PVC connections 15mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
S&F of 32 mm dia flexible waste hose for WHB/SINK/urinal etc complete all as specified and as directed .
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed .
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointed to fixed wall complete all as specified and as directed .
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring jointed to fixed wall complete all as specified and as directed .
S&F 75 MM PVC (SWR) bends any radius complete all as specified and directed.
S&F 110 MM PVC (SWR) bends any radius complete all as specified and directed.
S&F 75 MM PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F 75 MM PVC (SWR) junction single, (Double T) equal or unequal complete all as specified and directed.
S&F 110 mm PVC (SWR) junction double, (double T), equal or unequal complete all as specified and directed
S&F 75 mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed
S&F 110 mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed
S & F 110 mm PVC (SWR) vent cowl complete all as specified and directed
S & F 110 mm PVC (SWR) vent cowl complete all as specified and directed
S&F in repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 75 mm dia PVC pipe complete all as specified and directed
S&F in repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof of 110 mm dia PVC pipe complete all as specified and as directed.
Taking down cement plaster or concrete including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in two layers 10mm thick in CM 1:4 followed by 5mm thick CM 1:4 with approved WPC, finished even and fair complete all as specified and as directed.
M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces with cement plaster 1:6, finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
M & L for preparation of newly plastered surfaces of wall applying Two coat of cement base paint over a coat of chalk whitening primer complete all as specifled and directed
M & L for preparation of newly plastered surfaces of wall applying Two coat of OBD over a coat of chalk whitening primer complete all as specifled and directed
S&F 75 mm PVC (SWR) Floor trap plain with grating including jointing with solvent cement complete all as specifled and directed
S&F 75 mm PVC (SWR) multi Floor trap plain with grating including jointing with solvent cement complete all as specified and directed
Petty repairs to leakage of bib tap/pillar cocks stop cock pvc connection waste pipe float valve,angle valve,conceled valve gi pipe re fixing of bottle trap etc by changing the pvc washer /sheet washers or any other minor accessories etc complete all specified and directed
Petty repairs to high orv low level flushing cistern bu adjusting the foat valve leakage of PVC connection ,PVC bend including replacing of rubber washer check nuts plunger etc any type of flush complete all specified and directed
Renewing glazed or ciramic tile in patches area not exceeding 4 sqm including removing and cleaning old tiles prepairing beds and leying or setting ,jointing and pointing new or old tiles complete all specified and directed
Renewing plastering in patches area n.exc 4 sqm including removing and cleaning of old plaster and applying two coat of white wash /colour wash on new plaster surface and as per site requirement complete all specified and directed
S&F in repairs 32 mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all specified and directed
S&F in repair CP fancy type wall mixer with L bend (provn of OH shower) for bathroom 15 mm dia complete all specified and directed
S&F in repair CP two way bib tap with health fauct 15 mm dia with 1.00 mtr tube and hook (branded tube) complete all specified and directed
S&F in repair PVC two way bib tap with health fauct 15 mm dia with 1.00 mtr tube and hook (branded tube) complete all specified and directed
S&F in repair Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) complete all specified and directed
S&F in repair CP hand shower rose 1.00 M long 15 mm dia complete all as specified and directed
S&F in repair Toilet paper holder, (colour ) brass CP or SS type fixed to walls with chorimum plated(CP) Brass screws complete all as specified and directed
S&F repairs PVC Urinal waste pipe of size (31/32x800 mm dia) complete all as specified and directed
S&F in repair urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (minimum weight 60 gms) complete all as specified and directed
S&F in repairs for the following items at any locaton,position etc complete all specified and directed:-
GI Tee 15 mm (ISI marked)
GI Tee 20 mm (ISI marked)
GI Tee 25 mm (ISI marked)
GI Elbow 15 mm (ISI marked)
GI Elbow 20 mm (ISI marked)
GI Elbow 25 mm (ISI marked)
GI union 15 mm (ISI marked)
GI union 20 mm (ISI marked)
GI union 25 mm (ISI marked)
GI Nipple 15 mm 50 mm long (ISI marked)
GI Nipple 15 mm 100 mm long (ISI marked)
GI Nipple 15 mm 150 mm long (ISI marked)
GI Nipple 15 mm 300 mm long (ISI marked)
GI Nipple 20 mm 50 mm long (ISI marked)
GI Nipple 20 mm 100 mm long (ISI marked)
GI Nipple 20 mm 150 mm long (ISI marked)
GI Nipple 20 mm 300 mm long (ISI marked)
GI Reducer 25 mm 20 mm (ISI marked)
GI Reducer 20 mm 15 mm (ISI marked)
GI socket 15 mm (ISI Marked)
GI socket 20 mm (ISI Marked)
GI socket 25 mm (ISI Marked)
20 mm Nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm 45gms /25mm- 6
25 mm Nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm 45gms /25mm- 7
GI extension nipple 15 mm bore (ISI Marked)
15 mm Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms).
15 mm dia Pilar taps of PTMT high pressure screwed for iron pipe and fixed(minimum weight 15 mm -110 gms )
Stop valves, CP,Cast copper alloy , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed 15 mm bore
15 mm stop volve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms).
15 mm angle stop volve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms).
Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of wall, floors, etc. complete all as specified and as directed.
Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor wire drawn into existing concealed conduit including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete all as specified and as directed. for the following point wiring :-
One light point controlled by one switch.
One fan point controlled by one switch.
One Exhaust fan point controlled by one switch.
One 3 pin socket outlet 5 Amps,same board with cables 1.5 Sqmm size.
One 3 pin socket outlet 5 Amps, independent board with cables 1.5 Sqmm size.
One bell/buzzer point controlled by one push button with other switches on indipendent board with cable 1.5 Sqmm size.
One light point controlled by two 2- way switches, with cable 1.5 Sqmm size.
All as per item ser no 137 above here in before but one 3 pin socket outlet 5/15 Amps, indipendent board with cables 4.0 Sqmm size complete all as specified and as directed .
Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor drawn into including PVC casing & caping/fixed on wall/roof/ceiling etc of size not less than 20 mm dia including provision of 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel treminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet covercomplete all as specified and as directed for the following :-
One light point controlled by one switch.
One 3 pin socket outlet 5 Amps, independent board with cables 1.5 Sqmm size.
All as per item ser no-139 above here in before but one 3 pin socket outlet 5/15 Amps, indipendent board with cables 4.0 Sqmm size.
M&L for sub main wiring for phase and neutral with PVC FRLS insulated unsheathed multi stranded along with earth wire FRLS PVC insulted copper conductor, single core cable in and including surface/concealed /PVC conduit of appropriate size as specified for the following sizes. Note:- : 1. Cutting chases for concealed wiring shall be measured and paid seperately. 2. Rates are including taking down old unserviceable. :-
2x 4.0 sqmm and 1x 4.0 sqmm as earth wire
2x 6.0 sqmm and 1x 6.0 sqmm as earth wire
S&F in repair for switch piano, flush type single pole , one way 5 amp complete all as specified and as directed
S&F in repair for switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and as directed
S&F in repair for bell push flush type, 5 Amp complete all as specified and as directed
S&F in repair for switch piano, flush type single pole , two way 5 amp complete all as specified and as directed
S&F in repair for switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed
S&F in repair for ceiling rose three terminals/ PVC/ polycarbonate, isolated body complete all as specified and as directed
S&F in repair for Lamp holder angular/batten type, PVC/ polycarbonate type with back plate complete all as specified and as directed
S & F in repair stepped type electronic fan regulator flush type on the existingphenolic laminated sheet etc and including taking down old all as specified and as directed
Supply and fixing in repair of modular switch one way 5/6 A white Active one module all as specified and as directed
Supply and fixing in repair of modular switch socket combination 16 A, 6 pin 3 module flush type Active white two module complete all as specified and as directed
Supply and fixing in repair of modular switch socket combination 5 Amp, 5 pin flush type Active white three module complete all as specified and as directed
Supply and fixing in repair of socket 2M 6A-2/3 pin combined Active white all as specified and as directed
Supply and fixing in repair of modular fan step regulator,120 W-2 module all as specified and as directed
Supply and fixing in repair modular bell push 6 A one module complete all as specified and as directed.
Supply and fix high efficiency wall mounted T 8 LED batten light fitting 4 ft and including taking down old unserviceable fittings all as specified and as directed.
Supply and fix high efficiency wall mounted LED batten type polycarbonate tube not less than18W 4 ft LED light fitting and including taking down old unserviceable fittings all as specified and as directed
Supply and fix high efficiency wall mounted LED batten type polycarbonate tube not less than10W 2 ft LED and including taking down old unserviceable fittings all as specified and as directed
Supply and fix Energy saving not less than 25 Watts LED light fitting ,IP66 powder coated pressure die cast aluminium high power street light with heatresisant toughened glass with lens by providing GI pipe medium grade 25 mm dia 1.5 Mtr in length with suitable size MS Clamp two nos made out of 25x3 mm FI incl two coat of synthetic enamel paint over a coat of red oxide primer, prewired and including connecting up with 3 core flexible copper conductor cable of 1.5 Sqmm from ceiling rose to fitting and including taking down old u/s damaged complete all as specified and as directed
S&F sheet metal enclosure vertical TPN MCCB DB 4 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements complete all as specified and as directed Note :-(i) Including taking down old u/s DB, MCCB and MCB's (ii) MCCB and MCBs shall be measured and paid separetly under the respective item of shedule.
S&F sheet metal enclosure vertical TPN MCCB DB 8 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements complete all as specified and as directed Note :-(i) Including taking down old u/s DB, MCCB and MCB's (ii) MCCBs and MCBs shall be measured and paid separetly under the respective item of shedule.
S&F sheet metal enclosure vertical TPN MCCB DB 12 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements complete all as specified and as directed Note :-(i) Including taking down old u/s DB, MCCB and MCB's (ii) MCCB and MCBs shall be measured and paid separetly under the respective item of shedule.
S&F sheet metal enclosure Horizontal TPN DB 8 way double door with spreader terminals,insulating phase barrier and hardware with neccesary arrangements all complete all as specified and as directed Note :-(i) Including taking down old u/s DB, MCB's (ii) MCBs shall be measured and paid separetly under the respective item of shedule.
S&F MCB,DB SPN 12 way double door DB with 200 amps rated copper bus bar in SS enclosure double door type complete all as specified and as directed. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule.
S&F MCB,DB SPN 08 way double door DB with 200 amps rated copper bus bar in SS enclosure double door type complete all as specified and as directed.. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule.
S&F MCB,DB SPN 04 way double door DB with 200 amps rated copper bus bar in SS enclosure double door type complete all as specified and as directed. Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule.
S&F MCB,DB SPN 02 way in SS enclosure type complete all as specified and as directed. . Note : MCB SPN/SP shall be measured and paid under the respective item of the schedule.
M&L for cutting chases on brick walls concrete surfaces not exc 10cm girth and making good in cement mortar (1:3) the existing surface after carryiing out the concealed wiring including necessary finishes complete all as specified and as directed.
Supply and fix for MCCB 4 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting type type 200 Amps with breaking capacity 36 KA complete all as specified and as directed
Supply and fix for MCCB 4 Pole, 415 V, Fixed thermal & Fixed Magnetic setting type type 150/160 Amps with breaking capacity 25 KA complete all as specified and as directed. Note : Including taking down old unserviceable.
Supply and fix for MCCB 4 Pole, 415 V, Fixed Thermal & Fixed Magnetic setting type type 125 Amps with breaking capacity 16 KA complete all as specified and as directed. Note : Including taking down old unserviceable.
Supply and fix for MCCB 4 Pole, 415 V,adjustable Thermal & Fixed Magnetic setting type type 100 Amps with breaking capacity 16 KA complete all as specified and as directed. Note : Including taking down old unserviceable.
Supply and fix for MCB TP 415 V, 25-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed
Supply and fix in repair for MCB TPN 415 V, 40-100 Amps with breaking capacity 10KA C curve complete all as specified and as directed. Note : Including taking down old unserviceable.
Supply and fix for MCB SPN 230 V, 40-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed.Note : Including taking down old unserviceable.
Supply and fix for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve complete all as specified and as directed. Note : Including taking down old unserviceable.
Supply and fix for Buzzer, Ding Dong AC, 230 volts, single pole complete all as specified and as directed.
S& F for sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one SP MCB 20-32 Amps complete all as specified and as directed.
Material and labour for Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level , with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected with and incl GI earth wire 4mm dia including alternate 5 layers of charcoal, salt crystal and including 15 mm dia GI pipe light grade by means of nuts, bolts, washers and necessary earth work upto 7.5 mtr and connecting to test point, LT Switchgear etc as per site requirement including necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in elecrical plate No 3 of SSR Pt- I including testing on completion complete all as specified and as directed. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, RCC cover, reinforcement, removal of surplus soil , site clearance etc complete all as specified and as directed.
M&L for GI Pipe 15 mm light grade galvanised, with all fitting laid in trenches complete all as specified and as directed.
Supply and fix for high efficiency 24 watts 2 x 2 sqft LED light with panel for recesssed mounting dust free installation with high brightness LEDs for glare free homogenous illumination andsuitable for ceilling cut out 600 x 600mm complete all as specified and as directed. Note:- Including taking down the existing unserviceable FTL fittings.
Supply and fix for high efficiency 24 watts 2 x 2 sqft LED light with panel for surface mounting dust free installation with high brightness LEDs for glare free homogenous illumination 600 x 600mm complete all as specified and as directed. Note:- Including taking down the existing unserviceable FTL fittings.
Supply and fix 230 V, 1200mm ceiling fan, smart saver-50 complete all as specified and as directed.
Supply and fix Exhaust fan 300 mm Sweep, 230 volts,50Hz complete all as specified and as directed.
Supply and fix BEE Rated LED Lamps 9W - B22 / E27 complete all as specified and as directed.
Supply and fix BEE Rated LED Lamps 14W - B22/ E27 - complete all as specified and as directed.
Supply and fixing in repair of GI metal flush box suitable for mounting moduler plate complete all as specified and as directed of following modules:-
1 (or) 2 module
3 Module
6 Module
Supply and fixing in repair of combined both frame and cover plates fixing on mounting boxes complete all as specified and as directed for following modules:-
Cover plate with frame,1 module
Cover plate with frame,3 Module
Cover plate with frame,6 Module
Taking down unserviceable LED light fittings of any watt and type from existing position on pole/ wall/ tower/gate/hanger, complete for repair and keep in safe costody for refix the serviceable light fittings all as specified and as directed. Note: (i) New spare parts required for replacing old unserviceable parts shall be measured and paid separately as ‘ Supply only’ under relavent item here-in-after ii) Quoted rate is deemed to be included the charges of necessary ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS work as per site requirement. (iii) Labour cost for replacing spare parts,removing unserviceable parts, dismantling light fittings are deemed to be included in the quoted rate.
Refixing the serviceable light fitting in existing position after repair of any watt and type on existing pole complete all as specified and as directed
Supply,Fixing and Testing LED street light luminaire fitting of not less than 45 Watt,Luminaire fitting of IP 66 protection comprises of Pressure die cast Aluminium housing powder coated,with luminaire efficacy not less than 100 lm/w provided with Surge Suppressor 5 KV complete and making good disturbed surfaces complete all as specified and as directed.
All as per item No 192 but 35 Watt
Supply and Fixing and Testing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with Surge Suppressor 5 KV complete and making good disturbed surfacescomplete all as specified and as directed.
All as per item No 194 but 40 watt.
S&F out door drivers any type and 50-75 wattage after taking down old unserviceable flood lights/post top latern lights/street light/security lights including necessary connecting arrangements as per site requirement all complete all as specified and as directed.
All as per item No 194 but 35-45 wattage
Supply only surge protection devicess any type and KV for 5 KV suitable for LED light fittings up to 75 watts capacity flood lights/post top latern lights including necessary connecting arrangements as per site requirement complete all as specified and as directed.
Refixing the serviceable light fitting in existing position after repair of any watt and type on existing pole complete all as specified and as directed
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core solid conductor nominal cross section in service connection complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out in soft / loose soit including removing green vegetation,roots,bushes etc from surroundings near electric poles/panels or sub stations area Complete all as specified and directed.
Taking down old corroded and unserviceable Avaition light fittings of heavy duty dual/twin type light any type and cap from existing positions i.e Towers / Hangars / Buildings / Overhead tanks etc of height up to 30 mtrs and Supply,fixing and Testing LED Twin type Low intensity Aviation light fittings of cap 9W in and including neccessary arrangements of nuts,boltswelding works etc complete all as specified and as directed. Note - (i) Quoted rate is deemed to be included the charges of Boom lift , tools and plants etc as per site requirement.and MS work complete as per site requirement.
M&L for GI plate earthing of machinery/equipment Installed at power house/substation /Lightning protection, using 32 x 6 mm galvanized MS strip and MS galvanized plate of size 600 x 600 x 6 mm ,as earth electrode, including alternate 5 layers of charcoal, salt crystal and including 15 mm dia GI pipe light grade by means of nuts, bolts, washers and necessary earth work upto 7.5 mtr and connecting to test point, LT Switchgear etc as per site requirement including necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in elecrical plate No 3 of SSR Pt- I including testing on completion complete all as specified and as directed. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, Company moulded RCC cover, reinforcement, removal of surplus soil , site clearance etc.
M&L for repairing of old damaged earthing pit chamber at existing earth point including S&F 40 mm thick Company moulded RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in elecrical plate No 3 of SSR Pt- I including testing on completion complete all as specified and as directed. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, Company moulded RCC cover, reinforcement, removal of surplus soil , site clearance etc.
Taking down old damaged and unserviceable lighting arrester strip and test point box with gun metal or phosphorus bronze of any size/ from existing positions i.e Towers / Hangars / Buildings / Overhead tanks etc of height up to 30 mtrs etc and keep in safe custody for refix the good conditional serviceable lighting arrester strip and test point box with gun metal or phosphorus bronze complete all as specified and as directed. Note - (i) Quoted rate is deemed to be included the charges of Boom lift , tools and plants etc as per site requirement.and MS work complete as per site requirement.
M&L for Alluminium strip 25 x 3.0 mm complete with epoxy saddles and fixing the strip complete all as specified and as directed.
M&L for GI Strip 32X6 mm buried in ground fixed on wall / drawn in GI Tubing complete all as specified and as directed.
M&L for Copper strip 20 x 3.15mm buried in ground fixed on wall / drawn in GI Tubing complete all as specified and as directed.
Refixing in repair Alluminium strip 25 x 3.0 mm complete with epoxy saddles and fixing the strip complete all as specified and as directed.
Refixing in repair GI Strip 32X6 mm buried in ground fixed on wall / drawn in GI Tubing complete all as specified and as directed.
Refixing in repair Copper strip 20 x 3.15mm buried in ground fixed on wall / drawn in GI Tubing complete all as specified and as directed.
Supply and Fixing Pipes galvanised, "light grade " supplied and laid complete including fittings as GI strip protection 40mm dia bore complete all as specified and as directed.
Supply and fix Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
Supply and fix Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and as directed.
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm incl GI box of required size drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
Supply and fix epoxy saddle of suitable size for fixing of aluminium strip on wall/roof/pole etc complete all as specified and as directed. Note:- New saddle will be used in existing location wherever required to replace damaged saddles.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core solid conductor nominal cross section in service connection complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and as directed. Note - (i) Quoted rate is deemed to be included the charges of tools and plants etc as per site requirement and MS work complete as per site requirement.
Material and labour for point wiring with two single core 1.5 Sqmm (Nominal cross sectional area) size multi stranded copper conductor cable and one single core 1.5 sqmm (nominal area) copper conductor as earth wire connected to common earth duly 1100 volts grade FRLS insulated unsheathed cable in and including stove enamelled steel rigid concealed conduit of 20mm dia including tee bends, elbows etc., for one flame proof concealed conduit wiring light point controlled by one flame proof switch including necessary cutting on wall/ceiling and making good distrubed surface complete all as specified and as directed .
Taking down old corroded and unserviceable Flame proof light fittings of heavy duty single and dual/twin type any cap from existing positions i.e Hangars / Buildings/wall etc complete all as specified and as directed. Note - (i) Quoted rate is deemed to be included the charges of tools and plants etc as per site requirement and MS work complete as per site requirement.
Supply and fixing LED light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
Refixing in repair Flame proof light fittings any watt/ size on Hangars / Buildings / wall etc complete all as specified and as directed.
Supply and fix high efficiency polycarbonate NEO T8 LED tube not less than 18W for 4 ft bracket fitting and including taking down old unserviceable fittings complete all as specified and as directed.
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed.
Ditto- Item No 234 but 25A, double pole complete all as specified and as directed.
Taking down old unserviceable sub main wiring any size/make from existing position all as specified and as directed by Engr-in-charge. Note - (i) Quoted rate is deemed to be included the charges of tools and plants etc as per site requirement and MS work complete as per site requirement complete all as specified and as directed.
Material & Labour for following submain wiring alongwith earth wire in and including the suitable size of stove enamelled rigid ERW steel conduit incl FRLS PVC insulated copper conductor,two run single core cable for phase & Neutral and single run as earth wire in surface/ recessed as required and directed by Engr-in-charge :- Note - Quoted rate is deemed to be included the charges of necessary T&P/ Crane, labour etc and MS work complete all as per site requirement and complete all as specified and as directed.
All as per item no-229 here-in-before but 2X1.5 Sqmm for phase & Neutral and 1X1.5Sqmm as earth wire.
All as per item no-229 here-in-before but 2X4 Sqmm for phase & Neutral and 1X4 Sqmm as earth wire.
All as per item no-229 here-in-before but 2X6 Sqmm for phase & Neutral and 1X6 Sqmm as earth wire.
M & L for black stove enamelled rigid ERW steel conduit 25 mm dia fixing with suitable size MS clamp / saddles as per site requirement complete all as specified and directed .
SUSII CONSTRUCTIONS
NLK Construction
M B JAYAVEL
RD ENTERPRISES
R.P.TRADERS
C SRINIVASAN
Banyan Engineers and Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .