Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹158.8 CrAccepted-AOC CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹158.8 Cr Quoted ₹158.9 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹161.4 CrRejected-Finance | ₹161.4 Cr | L2 | Rejected-Finance Not Being lowest |
| 3 | L3₹169.2 CrRejected-Finance BU S S F S FLATS NEAR INCOME TAX COLONY OUTER RING ROAD PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | ₹169.2 Cr | L3 | Rejected-Finance Not Being lowest |
| 4 | L4₹173.3 CrRejected-Finance PLOT NO 65 SECTOR 18 OPP HIPA SARHAUL GURUGRAM 122 001 | ₹173.3 Cr | L4 | Rejected-Finance Not Being lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical Remark as per TSC |
Tender Value
₹175 Cr
EMD Value
₹15 L
Closing Date
30 Mar 2024, 6:00 pmClosed
Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone Spread Eagle Falls Shillong -793011
PROVN OF OTM AND RUNWAY AT LIKABALI MILITARY STATION UNDER GE 872 EWS
2023_MES_611592_1
CESZ/LIKA/ OF 2023-24
Open Tender
Civil Works
1095 days
Likabali
As per NIT
2 documents required · 2 mandatory
₹3,000
GE 872 EWS
₹15 L
Yes
HQ Chief Engineer Shillong Zone
3 Jul 2024
1 Aug 2023
1 Apr 2024
13 Jan 2024
30 Mar 2024
25 Mar 2024
2 Aug 2023 - 9 Aug 2023
1 Sept 2023
Amount
Note:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and General conditions of contracts before entry/quoting the rates.
Lumpsum price workedout by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II.
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III.
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIFICATIONS as listed in Schedule ‘A’ Part-IV.
Lumpsum price worked out by the tenderer for ROADS / PATH / CULVERT / FOOTPATH as listed in Schedule ‘A’ Part-V.
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI.
Lumpsum price worked out by the tenderer for COMPOUND WALL/ FENCING/GATE as listed in Schedule ‘A’ Part-VII.
Lumpsum price worked out by the tenderer for RETAINING WALL as listed in Schedule ‘A’ Part-VIII.
Lumpsum price worked out by the tenderer for RIGID RUNWAY/LINK TAXI TRACK/DISPERSAL as listed in Schedule ‘A’ Part-IX.
Lumpsum price worked out by the tenderer for BUTT WALL OF RUNWAY as listed in Schedule ‘A’ Part-X.
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-XI.
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XII.
Lumpsum price worked out by the tenderer for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-XIII.
Lumpsum price worked out by the tenderer for REFRIDGERATOR DEEP FREEZER AND WATER COOLER as listed in Schedule ‘A’ Part-XIV.
Blank
Blank
Lumpsum price worked out by the tenderer for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-XVII.
Lumpsum price worked out by the tenderer for DEMOLITION/DISMANTLING/TAKING DOWN as listed in Schedule ‘A’ Part-XVIII.
Sch 'A' Sec-XIX (Miscellaneous Items)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Bringing approved earth (as approved by Garrison Engineer) from sources outside defence land including all cost such as royalty if any , transportation ,taxes,etc. for area filling / area development upto MGL level including raising of original ground level upto MGL by approved earth and including spreading in layers not exc 30cm thick each layer ,watering , compaction with 8 tonne to 12 tonne power roller and finished to required size and shape etc. Notes: (i) Earth required for the item, shall be supplied by contractor, from out side MOD land of any lead, at his own own arrangement. (ii) All cost of procurement of earth including cost of transportation, compaction, royalties, tax etc shall be deemed to be included in the unit rate quoted by the contractor. (iii) With reference to clause 3.6 of MES part-II on serial page No-21 it is clarified that measurement of the above item shall be of finished embankment /traverse of filled earth after consolidation /compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk.
Preparation of unsurfaced WMM surface by brushing with wire brushes for removing caked mud etc, Sweeping with brooms and finaly fanning the cleaned surface with gunny bags to remove all loose, dirt etc complete all as specified and directed
M & L for Drainage Composite (Non-woven), Geotextile with Polypropelene Geonet confirming to IRC 34-2011 complete all as specified and directed.
M&L for in-situ stabilization of 500 mm in three layers of 2x150mm and bottom layer of 200mm thick, sub grade soil by uniform mixing of cement OPC 43 Grade @ 05 % by weight of soil as per mix design ( 5% percentage of cement taken for estimation, actual type of additive and percentage of blending to be given in mix design). Mix design should also contain recommended quality control tests with their frequencies. item will include pulverization of soil, spreading of additive, blending mix by tractor towed rotovator, addition of water/ drying of mix to required moisture content and compaction using suitable vibratory roller to required 98% Maximum Dry Density complete all as specified and directed. Relevant provisions of IRC: SP89-2010 be referred to for this item
M&L for 300 mm thick (compacted thickness) Granular Sub Base Course (GSB) Grade V in two layers of 150 mm thick), (as per table 400-1 and 400-2 of MORTH specifications for Road and Bridge works) over compacted subgrade with stone aggregates by using motor grader, spreading, levelling and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of atleast 98% of max dry density and consolidating to required gradient and camber complete all as specified and directed. Finished surface tolerances shall be as per table 900-1 of MoRTH specifications for Road and Bridge works 2013.
Supply and Laying (no additional payment for overlap) 400 micron thick HDPE sheet (Virgin Quality) having minimum weight 390 gm/sqm over sand cushion as specified in the design with overlap between adjacent strips as minimum 100mm and transverse joints at ends as minimum 150mm etc complete as specified and directed.
Supply only non-circular synthetic fibre reinforment fibres complete all as specified and directed
M&L for semi- perforated HDPE/PVC pressure pipe top to 2/3 portion perforated and bottom 1/3 non perforated including fittings such as sockets/coupline/Tee etc of 06 Kgf/Sqcm, 150mm dia complete all as specified and directed
M & L for non perforated HDPE pressure pipe of 6kg/sqcm, 150mm dia, including fittings like sockets, couplings, teers etc., laid in trenches for GEO DRAIN complete all as specified and directed.
M&L for preparation of new previously untreated concrete surfaces of any description over 10cm girth or width, not otherwise described and applying two coat of Painting lines, dashes, arrows, letters, etc. on roads, pavements and the like exc 10cm wide with road marking paint, white or golden yellow complete all as specified and directed
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI wire 4mm dia as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layers complete as shown in electrical plate No. 3 of SSR Part-I all as specified and directed .
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light/fan/Bell point controlled by one,one way switch complete all as specified and directed
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light point controlled by two ,two way switch complete all as specified and directed
M & L for Concealed Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One socket outlet point 6 A on independent board complete all as specified and directed
M & L for Concealed Point wiring with 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including PVC conduit of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 04 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one 16 Amp socket outlet on independent board complete all as specified and directed
S&F piano switch single pole flush type 6 Amp,two way, 230 Volt, complete all as specified and directed
M & L for Sub main Wiring with two run of 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Two single core cable and one No. earth wire and one run of conduit shall be measured together as one length
M & L for Sub main Wiring with two run of 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Two single core cable and one No. earth wire and one run of conduit shall be measured together as one length
M & L for Sub main Wiring with four run of 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Four single core cable and one No. earth wire and one run of conduit shall be measured together as one length
M & L for Sub main Wiring with four run of 6.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Four single core cable and one No. earth wire and one run of conduit shall be measured together as one length
M & L for Sub main Wiring with four run of 10.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC Conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 10.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed. Note: Four single core cable and one No. earth wire and one run of conduit shall be measured together as one length
Supply and fix epoxy powder coated Distribution Board VTPN 4way, 12 module vertical type with Incomer as MCCB 125 Amps and outgoing MCBs with common bus-bar at incoming end of outgoing MCBs grouted/ flush to wall complete all as specified and directed.
S&F Blank Plate for MCB DB of required size complete all as specified and directed.
S&F LED New Adore 10W B22 WW Ball lamp complete all as specified and as directed.
S&F Linear & compact 9W LED mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser with all fixing accessories, screws etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed
S & F LED street light fitting 1x20 watt (Building security light) made up of pressure die cast housing with prismatic polycorbonate diffusser and individual LEDs with secondary optics and IP 65 protection, 230 volts, complete with all accessories including and connecting with twin core of PVC insullated 0.5Sqmm copper conducter cable complete all as specified and directed
M&L Earthing with Copper Electrode 600x600x3.15 mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Copper strip 20 x 3 mm by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 25mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing of any description, complete all as per specified and as directed.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 25 x 4mm as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 32mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layers complete as shown in electrical plate No. 3 of SSR Part-I all as specified and directed.
M& L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed. Note : Punned thickness shall be measured and paid.
Supply and laying well burnt sub class ‘B’ bricks old size ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable complete all as specified and directed
Supply, installation testing and commissioning of 315 KVA outdoor transformer , step down 11KV/433V energy efficiency level-3 as per IS: 1180 of 2014 Part-I, 3 Phase 50 C/S AC double wound core type, copper wound, oil immersed naturally cooled (ONAN) with external cooling tubes/fins, delta/star connection on primary side (11KV) , and star connection on secondary side (433V) in accordance with vector symbol DYN-11 and having tapping at +/- 2.5%, +/- 5% and +/-7.5% to be changed by means of manually operated Off Load Tap Changing gear. The rate of temperature rise after continuous full load shall be all as specified in IS -2026. (Locaton : Admn Accn) The transformer shall be complete with the following:- (a) Cable entry box for LT on secondary side for suitable LT cable and HT on primary side for suitable HT cable including fixing arrangement as specified and directed by Engineer-in-Charge. (b) Oil conservator with filling cap, drain valve and oil level gauge. (c) Dehydrating breather with connecting pipe, first fill of dehydrating agent and oil seal. (d) Explosion relief vent mounted on tank with double diaphragm and equiliser pipe connection to conservator air space (pressure release device). (e) Air relief plug. (f) Thermometer pocket. (g) 100 mm dial type temperature indicator having range 0-120 degree C vapour pressure type with maximum reading pointer/Max temp indicator and resetting device. (h) Two earthing terminals on transformer body to suit 32 mm x 6mm GI strip. (j) Rating and diagram plate. (k) Drain valve with threaded adopter.
Supply, installation testing and commissioning 500 KVA outdoor type transformer, step down 11KV/433V energy efficient level-3 as per IS: 1180 of 2014 Part-I, 3 Phase 50 C/S AC double wound, core type copper wound, oil immersed naturally cooled (ONAN) with external cooling tubes, delta/star connection on primary side (11KV) , and star connection on secondary side (433V) in accordance with vector symbol DYN-11 and having tapping at +/- 2.5%, +/- 5% and +/-7.5% to be changed by means of manually operated OFF LOAD tap changing gear. The rate of temperature rise after continuous full load shall be all as specified in IS -2026. (For Admn Accn) The transformer shall be complete with the following:- (a) Cable entry box for LT on secondary side for suitable LT cable and HT on primary side for suitable HT cable including fixing arrangement as specified and directed by Engineer-in-Charge. (b) Oil conservator with filling cap, drain valve and oil level gauge. (c) Dehydrating breather with connecting pipe, first fill of dehydrating agent and oil seal. (d) Explosion relief vent mounted on tank with double diaphragm and equiliser pipe connection to conservator air space (pressure release device). (e) Air relief plug. (f) Thermometer pocket. (g) 100 mm dial type temperature indicator having range 0-120 degree C vapour pressure type with maximum reading pointer/Max temp indicator and resetting device. (h) Two earthing terminals on transformer body to suit 32 mm x 6mm GI strip. (j) Rating and diagram plate. (k) Drain valve with threaded adopter. (l) Filter valve with threaded adopder (top and bottom).
Supply, install commisioning and testing of APFC panel 150 KVAR with 6 steps (2x12.5 + 3x25 + 50) with MPP-H and MCCB as incomer manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed.
Supply, install commisioning and testing of APFC panel 300 KVAR with 6 steps (1x100 + 3x50 + 2x25) with MPP-H and MCCB as incomer manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed.
M&L SMS (sheet moulding compound) junction boxes surface mounting hinged door type with reteict type locking arrangement having size 200x300x120mm fixed to steel tubular pole with 02 Nos MS flat clamps 30x3mm suitable nuts & bolts and bottom blanking plate with 2 Nos cable glands suitable for 3.5 x 25 Sq mm cable XLPE armoured cable and mounted inside with 4 Nos epoxy moulded brass studs nuts & bolts and check nuts for connecting / looping of cable and one arial fuser of bakelite body 6 amps and PVC insulated cable to twin core 2.5 Sqmm with multistranded copper conductor cable 8.5 mtr through inside the pipe and connected complete all as specified and as directed.
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) ACB 800 Amp, 4 pole,50 KA 415 V manual drawout type with microprocessor release - 01 No Out Going (a) MCCB 200 Amp, 3 Pole 36 KA - 01 No (b) MCCB 100 Amp, 3 Pole 16 KA - 03 No (c) MCCB 63 Amp, 3 Pole 16 KA - 03 No (d) MCCB 32 Amp, 3 Pole 16 KA - 01 No (e) MCB 6 Amp, 3 pole , 6 KA ( streetLight) - 01 N0 (f) Time switch 20 Amp - 01 N0 (g) Digital Ammeter 3 phase - 01 N0 (h) Digital Volt meter 3 phase - 01 N0 (j) RYB indicating lamps ( RYB)
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) MCCB 125 Amp, 4 Pole 25 KA with shunt trip coil - 01 No Out Going (a) MCB 6 Amp, 230V, 2 POLE 10 KA - 01 No (b) MCB 6 Amp, 2 POLE 10 KA - 01 No (c) MCCB 100 Amp , 3 POLE 16 KA - 01 No (d) MCCB 32 Amp, 3 POLE 16 KA - 01 No
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) MCCB 100 Amps , 4 Pole 16 KA with shunt trip coil - 01 No Out Going (a) MCB 16 Amp, 2 Pole 10 KA - 01 No (b) MCB 6 Amp, 2 Pole 10 KA - 01 No (c) MCB1 6 Amp, 2 Pole 10 KA- 01 No (d) MCB 6 Amp, 2 Pole 10 KA - 01 No
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) MCCB 250 Amp ,4 Pole , 36 KA with shunt trip coil - 01 No Out Going (a) MCCB 100 Amp, 3 Pole 25 KA - 01 No (b) MCB 6 Amp, 2 Pole 10 KA - 01 No (c) MCB 63 Amp, 3 Pole 25 KA - 01 No (d) MCB 16 Amp, 2 Pole 10 KA - 01 No (e) MCB 32 Amp, 2 Pole 10 KA - 01 No
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) MCCB 63 Amp 2 Pole 25 KA with shunt trip coil- 01 No Out Going (a) MCB 6 Amp, 2 Pole 10 KA - 01 No (b) MCB 16 Amp, 2 Pole 10 KA - 01 No (c) MCB 16 Amp, 2 Pole 10 KA - 01 No
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) MCCB 250, Amp 4 Pole, 25 KA with shunt trip coil - 01 No Out Going (a) MCCB 125 Amp, 3 Pole 25 KA- 01 No (b) MCCB 125 Amp, 3 Pole 25 KA - 01 No
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) ACB 3200 Amp, 4 Pole, 75 KA Manual drawout type with microprocessor release - 01 No Out Going (a) MCCB 800 Amp, 3 Pole, 50 KA - 01 No (b) MCCB 800 Amp, 3 Pole, 50 KA- 01 No (c) MCCB 800 Amp, 3 pole, 50 KA - 01 No (d) MCCB 200 Amp, 3 Pole 25 KA - 01 No (e) MCCB 63 Amp, 3 Pole 25 KA - 01 No (f) MCB 6 Amp, 3 pole , 6 KA - 01 No (g) Time switch 20 Amp - 01 No (h) Digital Ammeter 3 phase - 01 No (j) Digital Volt meter 3 phase - 01 No (k) RYB indicating lamps ( RYB) - 01 set
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) ACB 1000 Amp, 4 Pole, 50 KA Manual drawout type with microprocessor release - 01 No Out Going (a) MCB 16 Amp, 2Pole, 10 KA - 02 Nos (b) MCCB 800 Amp, 3 Pole, 50 KA - 01 No (c) MCB 16 Amp, 3 Pole , 10 KA - 01 No (d) MCB 16 Amp , 3 Pole 10 KA - 01 No
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) MCCB 400 Amp 4 Pole 36 KA with shunt trip coil - 01 No Out Going (a) MCCB 200 Amp, 3 Pole, 36 KA - 01 No (b) MCB 6 Amp, 2 Pole, 10 KA - 01 No (c) MCCB 100 Amp, 3 Pole 16 KA - 01 No
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) ACB 1000 Amp, 4 Pole, 50 KA Manual drawout type with microprocessor release - 01 No Out Going (a) MCCB 800 Amp, 3 Pole, 50 KA - 01 No (b) MCB 16 Amp, 2 Pole, 10 KA - 02 Nos (c) MCB 6 Amp, 2 Pole, 10 KA - 01 No (d) MCCB 63 Amp , 3 Pole 25 KA - 01 No
Supply, install commisioning and testing of cubical outdoor feeder LT panel board manufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) MCCB 250 Amp 3 Pole 36 KA with shunt trip coil - 01 No Out Going (a) MCCB 160 Amp, 3 Pole, 36 KA - 01 No (b) MCB 16 Amp, 3 Pole, 10 KA - 01 No (c) MCB 6 Amp , 2 Pole 10 KA - 01 No (d) MCB 32 Amp, 2 Pole 25 KA - 01 No
Supply, install commisioning and testing of cubical outdoor feeder LT panel board with powder coated finishing platform mounted factory made totally enclosed dust and vermanufactured by a CPRI approved factory, made of MS angle iron 50 mm x 50mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, legs 0.6m long, totally enclosed dust & vermin proof (IP-65), double leaf door shutter in front side and single leaf shutter in rear side with necessary locking arrangement in both front and rear door and with four side projected slanting roof, duly powder coated of approved shade both internally and externally including mounting on PCC platform made out of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), 150 mm (100mm below & 50mm above GL) thick all round the panel board and necessary earth work. Entire enclosure shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth studs. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system and shall be complete with and internal wiring with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incomming (a) MCCB 80 Amp, 4 Pole 25 KA with shunt trip coil - 01 No Out Going (a) MCCB 32 Amp, 3 Pole 16 KA - 01 No (b) MCCB 32 Amp, 3 Pole 16 KA - 01 No
S&F PP-R (polypropylene Random Co -Polymer) gate valve (brass insert as pre requirement of the site) for outer dia of pipe size 75 mm bore complete all as specified and directed.
S&F PP-R (polypropylene Random Co -Polymer) gate valve (brass insert as pre requirement of the site) for outer dia of pipe size 110 mm bore complete all as specified and directed.
Construction of VALVE PIT TYPE 'A' of brick Masonry and of size 100 cm x 100 cm x100 cm (inner dimension) with all fittings and fixtures complete all as specified and as shown on drawing No. TD/EM/6 Sheet 1/2
Supply installation, testing and commissioning of diesel engine driven AC generator ISI marked water cooled type, 415 volts, 3 phase, 4 wire (Engine as per IS 10001/10002 and alternator as per IS:13364) complete with accoustic proof enclosure and foundation as per OEM recommendation, standard AMF panel with suitable protection and meters. The DG set should be of capacity 62.5 KVA incl Retrofit Emmission Control Device (RECD) for emmission control to meet the laterst CPCB norms & National Green Tribunal mandate as per Govt of India O.A No 681/2018 dt 6th Aug 2019 and policies issued thereafter. The DG set should comprise of following:- (A) Engine: - Diesel engine prime mover of suitable BHP multi cylinder 1500 RPM with prime continuous rating as per ISO 8528-1 to drive 62.5 KVA alternator with following:- (i) Fuel level indicator. (ii) Fuel tank of suitable capacity for storage of minimum 8 hrs consumption capacity at 75% load. (iii) Fuel inlet arrangement from outside the sound proof enclosure with locking arrangement. (iv) Common MS base frame with anti-vibration damper pads. (v) Continuous 10% overload capacity in every 12 hrs running. (vi) Self-starter with & incl suitable capacity maintenance free battery as per OEM recommendation with suitable charging circuit. (vii) Mechanical/ electronic governor as per OEM. (B) Alternator:- Alternator of capacity 62.5 KVA at P.F = 0.80 lag, 3 phase, 4 wire with following: - (i) Insulation class - ‘H’ (ii) RPM - 1500 (iii) Self regulated brushless self excitation. (iv) Automatic voltage regulation with bond of ± 2.5% of rated voltage.
Supply, installation, testing and commissioning of diesel engine driven AC generator ISI marked water cooled type, 415 volts, 3 phase, 4 wire (Engine as per IS 10001/10002 and alternator as per IS:13364) complete with accoustic proof enclosure and foundation as per OEM recommendation, standard AMF panel with suitable protection and meters. The DG set should be of capacity 200 KVA incl Retrofit Emmission Control Device (RECD) for emmission control to meet the latest CPCB norms & National Green Tribunal mandate as per Govt of India O.A No 681/2018 dt 6th Aug 2019 and policies issued thereafter. The DG set should comprise of following:- (A) Engine: - Diesel engine prime mover of suitable BHP multi cylinder1500 RPM with prime continuous rating as per ISO 8528-1 to drive 200 KVA alternator with following:- (i) Fuel level indicator. (ii) Fuel tank of suitable capacity for storage of minimum 8 hrs consumption capacity at 75% load. (iii) Fuel inlet arrangement from outside the sound proof enclosure with locking arrangement. (iv) Common MS base frame with anti-vibration damper pads. (v) Continuous 10% overload capacity in every 12 hrs running. (vi) Self-starter with & incl suitable capacity maintenance free battery as per OEM recommendation with suitable charging circuit. (vii) Mechanical/ electronic governor as per OEM. (B) Alternator:- Alternator of capacity 200 KVA at P.F = 0.80 lag, 3 phase, 4 wire with following: - (i) Insulation class - ‘H’ (ii) RPM - 1500 (iii) Self regulated brushless self excitation. (iv) Automatic voltage regulation with bond of ± 2.5% of rated voltage.
Supply installation, testing and commissioning of diesel engine driven AC generator ISI marked water cooled type, 415 volts, 3 phase, 4 wire (Engine as per IS 10001/10002 and alternator as per IS:13364) complete with accoustic proof enclosure and foundation as per OEM recommendation, standard AMF panel with suitable protection and meters. The DG set should be of capacity 30 KVA incl Retrofit Emmission Control Device (RECD) for emmission control to meet the laterst CPCB norms & National Green Tribunal mandate as per Govt of India O.A No 681/2018 dt 6th Aug 2019 and policies issued thereafter. The DG set should comprise of following:- (A) Engine: - Diesel engine prime mover of suitable BHP multi cylinder1500 RPM with prime continuous rating as per ISO 8528-1 to drive 30 KVA alternator with following:- (i) Fuel level indicator. (ii) Fuel tank of suitable capacity for storage of minimum 8 hrs consumption capacity at 75% load. (iii) Fuel inlet arrangement from outside the sound proof enclosure with locking arrangement. (iv) Common MS base frame with anti-vibration damper pads. (v) Continuous 10% overload capacity in every 12 hrs running. (vi) Self-starter with & incl suitable capacity maintenance free battery as per OEM recommendation with suitable charging circuit. (vii) Mechanical/ electronic governor as per OEM. (B) Alternator:- Alternator of capacity 30 KVA at P.F = 0.80 lag, 3 phase, 4 wire with following: - (i) Insulation class - ‘H’ (ii) RPM - 1500 (iii) Self regulated brushless self excitation. (iv) Automatic voltage regulation with bond of ± 2.5% of rated voltage.
Supply, installation, commissioning refrigerator electric driven single phase capacity more than 195 litres upto 310 litres (+ 2%) frost free, Triple door, BEE five star rated complete all as specified and directed
Supply, installation, commissioning refrigerator electric driven single phase capacity more than 310 litres upto 360 litres (+ 2%) frost free, Triple door, BEE five star rated complete all as specified and directed
S & F voltage stabilizer for automatic operation single phase, naturally air cooled indoor type designed for input variation between 90 v to 300 v with outputvoltage stabilizeat 230 with accuracy of ( +) (-) 2.2 % and capacity of 1 KVA complete all as specified and directed
Supply and install Air cooled spilt air conditioner Inverter type electric driven, single phase of capacity of 1.5 TR, 5 star rated complete with indoor and out door unit complete all as specified and as directed.
Supply and install Air cooled spilt air conditioner Inverter type electric driven, single phase of capacity of 2 TR, 5 star rated complete with indoor and out door unit complete all as specified and as directed.
2) S & F voltage stabilizer for automatic operation single phase, naturally air cooled indoor type designed for input variation between 90 v to 300 v with outputvoltage stabilizeat 230 with accuracy of + or - 2.5% and of capacity 5 KVA complete all as specified and as directed.
S & F Single phase motor starter 240 v 50 Hz AC only 25 A suitable upto 2 Ton ACs complete all as specified and directed.
Supply and Fix Bib taps cast copper alloy screwed down fancy type chromium plated, two way type (suitable for health faucet) with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed for 15 mm bore pipe complete all as specified and directed.
Supply and Fix chromium plated wall mixer 15 mm dia for mixing hot and cold water screwed down for iron pipe complete all as specified and directed.
M & L Geo fabric wrap conforming to section 702 of MORTH (5th Revision) for moderate installation condition for wrapping trench drain to hold aggregates (filter media) including minimum 100mm overlapping at joints complete all as specified and directed.
S&F step type electronic fan regulator flush type suitable for 100W, 240V AC complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm factory made complete all as specified and as directed.
S & F LED light fitting, 1 x 18 Watt, (4 Feet) 230 volts, with electronic driver and with best quality diffuser high lumen output, 2.5 KV voltage surge protection, PF > 0.98, THD < 10% suitable for surface/pendant mounting complete with all accessories including and connecting with twin core of PVC insulated 0.50 Sqmm copper conductor cable complete with all complete all as specified and as directed.
S & F Class-II (T2) low voltage surge protection device (SPDs) compliace to EN/IEC 61643-11 standard, IP with Imax 20 kA/pole 230V AC all complete all as specified and as directed.
Rds Project ltd.
KCC Buildcon Private Limited
Varindera Constructions Limited
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid