PROVISION OF ROOF TOP SOLAR POWER PLANT 70 KW AT CERTAIN BUILDINGS (P-190, P-191 AND P-201) AT BELAGAVI MIL STN UNDER GE BELAGAVI
2025_MES_736234_2
81313/E8
Open Tender
Civil Works - Others
Item Rate
120 days
GE Belgaum
As per tender documents
9 documents required · 9 mandatory
₹500
GE Belgaum
₹62,500
Yes
5 Mar 2026
12 Dec 2025
29 Dec 2025
12 Dec 2025
26 Dec 2025
19 Dec 2025
Note:- The quoted rate is deemed to be include for GI structure frame work with necessary foundation, fixing arrangements etc.
Supply, installation, testing and commissioning of Grid Tied String Inverter of capacity 125% of plant capacity, 415V AC, 50Hz, respectively at given load condition) IP 65 out door wall mountaing, with efficiency not less than 97% confirming to IEC 600682-2/vde standards with multifunctional LED indications with alarm and complying the following complete all as specified and directed :-- (a) Operating frequency/ range- 50 Hz (49 to 51 Hz), Grid Frequency Synchronization range ± 1 Hz or more (shall also compatible for Synchronization with DG Set) Waveform- Sine Wave Harmonics AC side total. (b) Ripple DC voltage ripple content shall not be more than 1% (c) Harmonic current distortion (<3%) (d) The benchmarking efficiency criteria for the Grid tied (central/string) inverter • At nominal voltage and full load is >95% • For load >25% is >94%. (e) No load losses should not be more than 5%. Power Factor > 0.9
S&F Outdoor type IP 55, powder coated, 2 mm thickness with stand of minimum height 2 feet, 1 In 1 Out LT Panel configuration with 63A MCCB, AC SPD Type 2 complete, minimum Size of Enclosure shall be 700 mm x 600 mm x 300 mm (IP 55) along with 4 pole 63 Amps, AC Surge Protection Device-3 ph of 36KA (as per IEC 60364-5-53), 4 Indication Lamp- R, Y, B.,with multi functional meter 3 phase, 415 Volt (Voltage , Current, Power and Energy unit measurement (KWH)) and including copper busbar, connecting lugs and double compression glands etc, complete all as specified and directed. Makes: Switchgear: Siemens, L&T, Legrand , Schneider, SPD: Citel/ Phoenix/ OBO. Note:- The quoted rate is deemed to be include for integration & synchronisation with existing three phase LT panel supply source.
Supply, installation connection & testing of AC DB Panel shall be metal clad, totally enclosed, rigid,wall mounted, air ventelator, cubical type suitable for operation on three phase, 415 volts, 50 Hz, 63 Amps with type 2 SPD NVR & contactor having provision of incoming & outgoing armoured cable) The panels shall be designed for minimum expected ambient temperature of 45 degree Celsius, 80 percent humidity and dusty weather. All indoor panels will have protection of IP54 or better. All outdoor panels will have protection of IP65 or better. All the 415 AC volts devices / equipment like bus support insulators, circuit breakers, SPDs, VTs etc., mounted inside the switchgear shall be suitable for continuous operation and satisfactory performance.
Supply, installation connection & testing of DC DB, IP65 Panel shall be metal clad, totally enclosed, rigid, wall mounted, air ventelator, with 20 Amp, 1000 Volts string fuses, DC MCB of 20 Amp, 1000 Volts & DC SPD 1000 Volts as per DC input rating of invertor. Short Circuit & Overload Protected, Over Voltage Protected (Y-PV), No Air condensation, Cu Wired with FR Insulation & Tested Wire Harnessing ot Ensure High Conductivity, Plug & Play Solution for Rooftop Solar PV Installations.
M&L 1.1 KV grade 4 core 25 Sqmm PVC or, XLPE insulated and PVC sheathed, multi-core multi- stranded Aluminium armoured cables shall be used; Outdoor AC cables shall have a UV- stabilized outer sheath all as specified and directed.
M&L 4 sq mm (single core) DC Cable XLPE insulated and sheathed, UV-stabilized, multistranded flexible copper cable, should be colour coded and including DWC HDPE pipe of conduit pipe of suitable size and clamps complete as all specified and directed.
S&F FRP (Hensel or equivalent make) / PP / ABS with dust, water and vermin proof. provided with proper locking arrangements. Series / Array Junction Box (SJB/AJB) (whichever is required): All the arrays of the modules shall be connected to DC DB. AJB shall have terminals of bus-bar arrangement of appropriate size. Male & Female pair of MC4 connectors compatible with 4 mm 2 DC solar cable.
M&L Aluminium strip 25 x 3 mm as per site conditions with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
M&L Chemical earthing in any type of strata (hard/loose) with Material/ Backfill compound shall be Highly Conductive Compound, maintenance free. The watering shall be required at the time of its installation only. No re-charging with water, salts or any other chemical shall be required and it shall maintain almost constant earth resistance during its life cycle without manual watering.(earthing rod of 19 mm D X 2 m Long 250 micron Cu bonded rod with chemical material) with Laying of Earthing AI strip of 25 x 3 mm - 04 Nos (01 No. in each building for building Nos. 190, 191, 201 & MLIRC installations) complete all as specified and directed.
Supply, installation & erection of suitable height as directed byEngineer- in- charge module mounting structure with required accessories for panel mounting. (Mild steel Ms) Coolum’s And Rafters with digging, cementing and Panel laying. (STADD PRO - 120 KMPH WIND), structure standard for solar panels. Structure shall be mounted using suitable RCC / PCC blocks. MS mounting structures may be used for mounting the modules / panels / arrays. Each structure should have angle of inclination as per the site conditions to take maximum insolation and including structure with suitable ladder & walkway and necessary water pipeline for cleaning of solar panels with accessories complete all as specified and directed.
M&L earthing complete with galvanized mild steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 m below normal ground level with top edge of the earth plate not less 1.5 m (BGL) connected to galvanized iron earth lead wire 4 mm dia by means of bolts, nuts, check nut and washer of galvanized iron and including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20 mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15 mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5 m length, charcoal, common salt, testing on completion all as shown in EP No. 3 of SSR 2009 part-I, connected to test point complete all as specified and directed. - 04 Nos
M&L spike type lightningaArrestor with 3 air terminals, material should be copper coated, air terminal diameter should be greater than 15 mm, size should not less than 01 meter, voltage - 12 kV, frequency 50 Hz, ball diameter should be greater than 40 mm, pipe should be greater than 24 mm with all accessories complete all as specified and directed.
NOTE: The quoted rate is deemed to be include for comprehensive maintenance contract (CMC) for of Solar Plant for five years from the certified date of completion of work.
Supply, Laying , jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection for the following sizes complete all as specified and directed :-
3.5 core 70 sqmm
4 core 16 sqmm
S&F 63 / 50 mm outer / inner dia double walled corrugated DWC HDPE pipe of conforming to IS:16205 complete all as specified and directed
stage.html
html • 0.03 MB
tech_bid_open.pdf
cancelled_1.pdf
pdf • 0.16 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
BOQ_833481.xls
BOQ • 0.48 MB
81313tender.pdf
Tender Documents • 1.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .