Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹18.2 L+₹2.5 L (16.2%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | L2 | Rejected-Finance Rates are high | |
| 3 | L3₹19.9 L+₹4.2 L (26.9%)Rejected-Finance | L3 | Rejected-Finance Rates are high | |
| 4 | L4₹20.5 L+₹4.9 L (31.4%)Rejected-Finance | L4 | Rejected-Finance Rates are high | |
| 5 | L5₹20.8 L+₹5.2 L (33.0%)Rejected-Finance | L5 | Rejected-Finance Rates are high |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
18 Aug 2020, 6:00 pmClosed
GE MIS MHOW
GE (Maint) INF School Mhow, 75 Mall Road , Mhow
REPAIR MAINTENANCE OF EARTHING MCBS MCCBS MCCB DBS SUB MAIN WIRING AND CONNECTED INTERNAL ELECTRICAL ITEMS UNDER GE MIS MHOW
2020_MES_364292_1
GE MIS/33 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE MIS MHOW
Plese refer tender documents
8 documents required · 8 mandatory
₹500
GE MIS MHOW
₹40,000
Yes
27 Oct 2020
27 Jul 2020
20 Aug 2020
3 Aug 2020
18 Aug 2020
10 Aug 2020
Amount
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc . Removing materials to store for keeping in safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces of walls, floors etc complete all as specified and directed by Engr-in-Charge
M & L for Point wiring in repairs with FR LS PVC insulated PVC unsheathed electric cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area drawn in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good and matching disturbed surface of wall with existing surface of wall (cutting except on ceiling for fan point only, on ceiling instead of PVC conduit surface casing caping will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as earth wire connected to earth dolly by providing lugs including galvanised boxes and bakelite sheet for mounting switches, sockets, fan regulators etc for the following including taking down the existing complete all as specified and directed.
(a) One light point/fan point controlled by one switch
(b) One bell point controlled by one switch
(c) One 5amps socket out let point controlled by one switch on same board with other switches.
(d) One 5amps socket out let point on independent board controlled by one switch.
All as per item No-1 here in before but using FR LS PVC insulated unsheathed 2.5 sqmm cross sectional area cable for phase /neutral & for earth 2.5 Sq mm green PVC insulated cable for 15 amps socket point on independent board controlled by one switch complete all as specified and directed..
S&F switch in repairs of piano flush button single pole one way 5 Amp 240 volt including taking down the existing complete all as specified and directed.
S&F in repairs of socket outlet flush type 5 pin, 5 amps, 230 volts including taking down the existing complete all as specified and directed.
S&F in repairs of Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal, 230 volts including taking down the existing complete all as specified and directed.
S&F in repairs of switch piano flush button single pole one way 15 Amp 240 volt including taking down the existing complete all as specified and directed.
S&F in repairs of socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts including taking down the existing complete all as specified and directed.
S&F in repairs of bell push single pole, 6 amps, 230 Volts, flush type including taking down the existing complete all as specified and directed.
S&F in repairs of ceiling rose surface bakelite three terminal including taking down the existing complete all as specified and directed.
S&F in repairs of lamp holder insulated body with back plate for batten fittings including taking down the existing complete all as specified and directed..
S&F in repairs of Bell, ding dong type, AC 230 Volts,single pole including taking down the existing complete all as specified and directed..
S&F in repairs of electronic Fan regulator, socket type and step type including taking down the existing complete all as specified and directed..
S&F in repairs of retrofit LED tube light T-8 type, 1x20 Watt, 6500K with extruded Al heat sink for efficient heat dissipation including taking down the existing complete all as specified and directed. Make:- Havells Cat No. LHLDDCXCML8Q020 or equivalent in Bajaj/Wipro
S&F in repairs of batten for retrofit type LED tube T-8 Type upto 1x22 Watt, pre-wired for LED tube complete with all accessories duly connection with three core flexible copper cable and duly fixed on and including two Nos PVC square boxes including taking down the existing complete all as specified and directed. Make:- Havells Cat No. LHFXCENNTN1W020 or equivalent in Crompton/Wipro. Note for item Nos. 14 & 15:- Makes of these items should be same and compatible with eath other.
M&L for Sub main wiring in repairs with two runs of single core FR LS PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including surface non metallic rigid PVC conduit not less than 25mm dia and all fittings like bends, tees, saddles etc including one run of FR LS PVC insulated unsheathed 6.0 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete.
M&L for Sub main wiring in repairs with two runs of single core FR LS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including surface non metallic rigid PVC conduit not less than 25mm dia and all fittings like bends, tees, saddles etcincluding one run of FR LS PVC insulated unsheathed 4 sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly complete.
M&L for Sub main wiring in repairs with two runs of single core FR LS PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, including PVC insulated unsheathed FR LS 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engr-in-Charge.
M&L for Sub main wiring in repairs with two runs of single core FR LS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, including FR LS PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engr-in-Charge.
S&F in repairs of flush mounting factory made Vertical TPN DB, IP-43 Protection -IK 08, with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for TP/FP 100-125 amps G Frame MCCB as incomer and SP/TP MCBs as out going 4 way complete all as specified and directed by Engr-in-Charge.
S&F in repairs of flush mounting factory made Vertical TPN DB, IP-43 Protection -IK 08, with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for TP/FP 100-125 amps G Frame MCCB as incomer and SP/TP MCBs as out going 8 way complete all as specified and directed by Engr-in-Charge.
S&F in repairs of flush mounting factory made Vertical TPN DB, IP-43 Protection -IK 08, with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for TP/FP 100-125 amps G Frame MCCB as incomer and SP/TP MCBs as out going 12 way complete all as specified and directed by Engr-in-Charge.
S & F in repairs of double door Vertical TPN DBs four way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed by Engr-in-Charge.
S & F in repairs of double door SPN DBs eight way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed by Engr-in-Charge.
S & F in repairs of double door SPN DBs four way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed by Engr-in-Charge.
S & F in repairs MCCB TP 100 Amps 25 KA breaking capacity, G-frame type including connection with suitable size aluminium / copper lugs including taking down the existing complete all as specified and directed by Engr-in-Charge.
S & F in repairs MCCB TP 160 Amps 25 KA breaking capacity, G-frame type including connection with suitable size aluminium/copper lugs including taking down the existing complete all as specified and directed by Engr-in-Charge.
S & F in repairs MCCB TPN 125 Amps 25 KA breaking capacity, G-frame type including connection with suitable size aluminium / copper lugs including taking down the existing complete all as specified and directed by Engr-in-Charge.
S & F in repairs of MCCB TPN 160 Amps 25 KA breaking capacity, G-frame type including connection with suitable size aluminium/copper lugs including taking down the existing complete all as specified and directed by Engr-in-Charge.
S & F in repairs of MCB TPN 50 to 63 amps 10 KA, c-series including connection with suitable size aluminium/copper lugs complete all as specified and directed by Engr-in-Charge.
S & F in repairs of MCB SPN 6 to 32 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge.
S&F in repairs of MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge.
M & L for Earthing in repairs complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.5 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed.
S&F in repairs of switch flame proof junction Box in LM-6, with plan cover 3/4 way 20 mm dia size, approved by CMRI Dhanbad all as specified and directed by Engr-in-charge. Make: Sudhir Cat No. JB/OA/104 or equivalent in Flexpro/Blinga/Shyam Switch Gear.
S & F in repairs of Flame proof totaly enclosed type Fluorescent tube light fitting 1X28 watt (T5) FLP-WP made of aluminium alloy LM-6 with electronic balalst bipin Holder, connector block etc complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable on wall/ceiling approved by CMRI Dhaanbad complete all as specified and directed by Engr-in-charge. Make Sudhir/Shyam Switch Gears
S & F in repairs of integrated LED tube light fitting 1x18/20 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of PVC square boxes including taking down the existing complete all as specified and directed. Make:- Havells Cat No. LUMILINEPLUSBS18WLED865SPCSS , Bajaj cat Pt No. BCLSBAL 18WCW or equivalent in Wipro
Note :- Contarcor will provide all T&P for repair/replacement of Lights & point wiring at Wall & ceiling at any Height. No extra cost will be given to contractor for T&P and Ladder etc required for repair/replacent of Lights & point wiring .
S.S. Engineers
ram prashad chotelal batham
M/S Pawan Babulal
m/s modern builder
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .