| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66,144.90Accepted-AOC AT SAMET ELECTRO TOWER TAMRIT MARKET COMPLEX ROOM NO 15 HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | ₹66,144.90 Quoted ₹56,055 | L1 | Accepted-AOC ACCEPTED DUE TO BECOMING TECHNOCOMMERCIALLY ELIGIBLE L1 BIDDER |
| 2 | Rejected-Technical NOT SPECIFIED | - | - | Rejected-Technical REJECTED FOR NOT BEING L1 |
| Sl No | Description | Qty | Unit | TARENI ELECTRICALS L1 | M/S MOHIT ELECTRICALS L2 |
|---|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A | 25 | Pts | 580 ₹14,500 | 600 ₹15,000 |
| 2.00Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required | |||||
| 2.01 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm | 55 | Mtr | 190 ₹10,450 | 200 ₹11,000 |
| 2.02 | 2 X 4 sq. mm + 1 X 4 sq. mm | 15 | Mtr | 210 ₹3,150 | 250 ₹3,750 |
| 3.00 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 3 | Nos | 330 ₹990 | 400 ₹1,200 |
| 4.00 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | 6 | Nos | 290 ₹1,740 | 300 ₹1,800 |
| 5.00 | Supplying & fixing angle holder including connection etc as required. | 4 | Nos | 60 ₹240 | 80 ₹320 |
| 6.00 | Supplying & fixing 3 pin, 5 Amps ceiling rose on the existing junction box/wooden block including connection etc. as required. | 21 | Nos | 45 ₹945 | 60 ₹1,260 |
| 7.00 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch | 6 | Nos | 50 ₹300 | 50 ₹300 |
| 8.00 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet | 9 | Nos | 80 ₹720 | 80 ₹720 |
Tender Value
₹95,962
EMD Value
₹1,200
Closing Date
28 Jan 2026, 5:00 pmClosed
Staff Officer(EnM),Bhubaneswari Area, MCL
Samar Parida, Staff Officer(EnM), Bhubaneswari Area, MCL E-mail so-enm-bbsa.mcl(at)coalindia.in
Electrical wiring of newly constructed Sampling office room at old JNC PO Office for use by Bhubanesawari OCP, BA
2026_MCL_351184_1
GM(JA)/EnM/ e-Tender/25-26/E-807/072 DTD. 13/01/2026
Open Tender
Electrical and Maintenance Works
21 days
TALCHER
AS PER NIT
4 documents required · 4 mandatory
₹1,200
Yes
11 Apr 2026
15 Jan 2026
30 Jan 2026
16 Jan 2026
28 Jan 2026
16 Jan 2026
16 Jan 2026 - 21 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
2 X 2.5 sq. mm + 1 X 2.5 sq. mm
2 X 4 sq. mm + 1 X 4 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying & fixing angle holder including connection etc as required.
Supplying & fixing 3 pin, 5 Amps ceiling rose on the existing junction box/wooden block including connection etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. double Pole
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 poles and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
Supplying and fixing following rating, double pole, (single phase and neutral), 240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63Amp
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A TP&N
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 18-22watts
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.19 MB
Tendernotice_2.pdf
PDF • 0.60 MB
BOQ_363957.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid