| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC 428 RAJA RAMMOHAN ROY ROAD HAKIMPARA SILIGURI | SILIGURI | L1 | Accepted-AOC WORK ORDER | |
| 2 | L2₹3.3 L+₹1,825.84 (0.56%)Rejected-Finance FD 85 SALT LAKE CITY SECTOR III KOLKATA 700 091 W B | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L2 | Rejected-Finance REJECTED | |
| 3 | L3₹3.3 L+₹3,542.03 (1.09%)Rejected-Finance | L3 | Rejected-Finance REJECTED |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
17 Aug 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASSISTANT ENGINEER III
GOALBARI PO SURI DIST BIRBHUM PIN CODE NO 731 101
Compound lighting arrangement at Panchra OHR site under Panchra water supply scheme under Bolpur Mechanical Division PHE Dte
2023_PHED_553634_2
PHED/03/AE-III/CMD/2023-2024
Open Tender
MECHANICAL
Item Rate
15 days
PANCHRA BIRBHUM
Please refer Tender documents.
6 documents required · 6 mandatory
₹7,000
17 Feb 2025
2 Aug 2023
21 Aug 2023
3 Aug 2023
17 Aug 2023
3 Aug 2023
Amount
Supply and delivery at site of GRP street light pole conical type 7 mtr. Length with base plate at bottom & internal junction box resin coated. [Make: Fibro Plastichem/EPP/PHED Approved]
(a) Single arm pole.
Supply and delivery at site of energy efficient LED street light fixture with IP66 and IK06 protected LM high pressure alluminium di cast housing with polycarbonate cover capable of delivery standard lumen output as follows .The lens plate should be bolted to the metal core PCB should not be glued . The driving current should be more than 700 mA . It should have internal surge protection of minium 4kv , lumen /watt >100, Drivier efficiency > 85% ,PF >0.95, THD<10% .
a] Philips BRP 409 LED 110 CW M2 FG PSU Gr V3./similar.
Erection of GRP pole of length of 7 meter in RCC(1:2:4) foundation of 400x400mm of depth of 1300 mm below GL and 200 mm just above GL. 4 nos "J" type foundation bolt of 20 mm dia and 600 mm long grouted into RCC foundation as per base plate of pole.Projected length of 100 mm also considered for fitting with the base plate of the pole.There should be a provision of two number flexible pvc pipe of 63mm dia for cable entry as per supplied drawing.Also the foundation along material will be made as per departmental drawing and design.
Supply and delivery at site of 1.1 KV grade 2 core 4 sq.mm XLPE insulated Al. Ar. Cable Conforming to IS:7098(Part-I) 1988 for outdoor lighting along with manufactures test certificate. [Make: Gloster/Havells/Polycab/PHED Approved]
Laying of one No. cable 4 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Fitting fixing above supplied LED light fitting complete with all accessories to be fixed with S&F length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required complete.
Earthing with 1no. of G.I. earth spike (20 mm dia. X 1.5 mtr. Long) driven into the ground upto 2 mtr drawing earth line with separate 6 SWG G.I. Wires providing 15 mm dia. G.I. pipe protection from earth spike feeder box/junction box/poles and fixing to the same by suitable nuts & bolts all complete as per direction of EIC.
Supply and delivery of 16 amp 240V rewireable type switch fuse unit.Make-Approved make
Fixing only above supplied Sheet Steel Main Switch (Rewirwable type) on Flat Iron Frame/Angle Iron Frame on wall).
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 2 Way.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
Testing and commissioning of whole installation as per direction.
Add: GST @ 18% on sum of Item No: 1 to 12
Add Cess @1% on sum of Item No. 13
ELECTRICAL AND MECHANICAL ENGINEERING CORPORATION
M/S D.G.B.ENTERPRISE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .