STAFF OFFICER E and M
OFFICE OF THE AGM, WCL PENCH AREA
Wiring and Electrical work at KV Barkuhi and Chandametta Kushti Akhara.
2023_WCL_295077_1
wcl-pe3350-enm-43-2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
BARKUHI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,959
29 Jan 2024
1 Dec 2023
9 Dec 2023
1 Dec 2023
8 Dec 2023
1 Dec 2023
1 Dec 2023 - 6 Dec 2023
Amount
Wiring and Electrical Work at KV Barkuhi and Chandametta Kushti Akhara
Supply & fixing of I.S.I. marked XLPE Armoured 4C x 10 sq mm
Supply & fixing of I.S.I. marked porcelain rewireable fuse unit of approved make or conforming to I.S. 2086-1982: 63Amp/415 Volts
Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 2 Module
Supplying and fixing PVC casing and capping (double fold) ISI marked along with accessories on surface etc. as required: PVC casing and capping (double fold) 32 mm x 12mm
Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase & N, 4 pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with thermal-magnetic release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2: MCCB 25kA current rating - 63 to100Amp & adjustable overload setting 80% -100% of In, adjustable short circuit setting 6-10 In 4Pole
Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.: 1 X 4.0 sq. mm.
Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.: 1 X 1.5 sq. mm.
Supply and fixing Led tube rod comprising of LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.: Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser.
Supply and fixing as per specification Switch of approved make ISI marked with necessary material complete.: 6/10Amp SP 250 Volt modular switch
Supply and fixing as per specification polycarbonate ceiling rose 3 plate of approved make ISI marked with necessary material complete.
Supply and fixing in position LED lamp of approved make: 9 Watt 250Volt
Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. 60Watt, color temp 6500k.
Supplying, erecting and testing of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fasteners etc. complete finished and as required.: 300mm sweep RPM 900 / 1400
Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of 'D' series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :- MCB DP For 40Amp 10kA rating
Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 16 Module PVC box
Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 8/9 Module PVC box
Supply and fixing as per specification socket outlet of approved make & ISI marked with necessary material complete: 10Amp 250 Volt 3 Pin modular type
Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board: 100 Watt (1 module)
Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.: 1 X 2.5 sq. mm.
GST as applicable should be quoted in percentage, it will be calculated on total amount of Sl. No. 1.01 to 1.19
RAJ ENGINEERING ASSOCIATE
harendra singh
ANSARI BROTHERS
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .