Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC SINCE LOWEST BIDDER | |
| 2 | L2₹31.9 L+₹2.3 L (7.88%)Rejected-Finance | L2 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 3 | L3₹32.4 L+₹2.8 L (9.38%)Rejected-Finance | L3 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 4 | L4₹40.9 L+₹11.3 L (38.1%)Rejected-Finance MASTER BUILDING DALHOUSIE ROAD DALHOUSIE ROAD PATHANKOT PATHANKOT GURDASPUR PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance SINCE NOT L1 BIDDER |
Tender Value
₹34.9 L
EMD Value
₹69,800
Closing Date
28 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AMRITSAR
HQ CWE AMRITSAR OLD CANTT
REPAIR /REPLACEMENT OF HT OH LINE, HT UG CABLES, GANG OPERATED DEVICES AND CONNECTED ACCESSORIES UNDER GE GURDASPUR
2022_MES_535366_1
CWE/ASR-25/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE GURDASPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE GURDASPUR
₹69,800
Yes
7 Sept 2022
2 Jul 2022
30 Jul 2022
2 Jul 2022
28 Jul 2022
16 Jul 2022
60 days
Amount
Excavation in trenches in soft/ loose soil, not exceeding 1.50 m wide and not exceeding 1.50 m in depth, for foundation of poles, stay, cable, pipes etc and getting out complete all as specified.
All as per Srl Item No 01.00 here-in-before but exceeding 1.5m and not exceeding 3 mtr in depth.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified.
Removal of surplus exavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified.
Supply and laying, un-reinforced precast concrete cable cover, class HV, type I flat, size 300mm x 180mm x 40mm laid flat in trenches over the cable with the length of cable cover perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engr in charge complete all as specified and directed.
M&L sand cushioning trenches using fine sand to under ground cable laid in two layer of fine sand, 8 cm thick before laying the cable and 15 cm after laying the cable, in trenches to cover under ground cable complete all as specified and directed.
Labour for drilling hole under the road with the help of BOCKI / by Manual or by machine for crossing GI tubing of any size for cable protection all as specified and directed.
M & L in replacement for cable protection GI tubing light grade fixed along the pole /under Road /along the wall of size 80 mm bore with necessary clamps all as directed.
M & L in replacement of cable protection GI steel tubing, 100mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall for protection of Cable / GI wire / GI strip with necessary clamps etc complete all as specified and directed.
M&L for crossarms in replacement , bracing, supports, clamps and brick plates, fabricated from staructural steel section including nut bolts washers including welding, bending , cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide all specified.
Supply and fixing in replacement of vertical type switch air break gang operated switch tripple pole mechanically operating mounted on insulator and steel frame with operting mechanism worked from ground level for current rating up to 200 Amps and working pressure of 11000 volts grade consisting of 4 insulator per pole with 25mm dia GI medium grade operating handle and locking arrangements fixed with down rod operating brackets all specfied & directed by Engr-in-charge.
All as per Srl Item No 11.00 here-in-before but current rating 400 Amps
Supply & laying in replacement underground XLPE insulated and PVC sheathed galvanised (E) steel strip or wire armoured (under ground) heavy duty electric cable with stranded aluminium conductor 11000 volts (E) grade of cross sectional area 185 Sqmm 3 core conforming to IS-7098 (partII) 1985 with the latest ammendment, laid in trenches/ducts/through pipes/in floor/road/along the pole etc all as specified & directed by Engr-in-charge
All as per item No.13 above but of size 120 Sqmm 3 core.
All as per item No.13 above but of size 95 Sqmm 3 core.
Taking down old HT ACSR conductor and supply, fixing and testing of aerial bunch cable (AB) HT grade 11 KV of Size 3 Core X 95 Sqmm, 1 Core X70 Sqmm (Insulated Messenger) constitute of three core stranded compacted circular alumunium conductor screened with black extruded semiconducting compound natural colour XLPE insulated and one layer of copper tape and covered with black extruded PVC (core identification by colour tape marking red yellow and blue with colour tape placed longitudenaly under the copper tape) and one bare messenger wire shall be stranded not compacted circular alumunium alloy conductor complete all as specified. Make :As per list of makes specified in CA & to be approved by GE. Note (i) Contractor shall use all fittings and accessories to install erect and join the AB cable i:e suspension clamp with eye hook suspension fittings and correspondings eye hook dead eye hook nylon tie piercing connectors suspension clamp etc under the quoted rate. (ii) Contractor has do all kind of tests for HT cable as per EI rule before fixing on poles including factory test report as per PS clause No 13.14.
Repair/servicing of existing GOD and decarbonized , proper function mechanism device fixed to nut bolt and use petrolium gel, proper jumpering with & rep[lacement of U/S parts of the GOD Note :- Replacement of items like PG clamp, Insulater, Male, Female link etc and conductor are measured and paid saperately.
M& L PIN type porcelain ,viterous white brown or green insulator incl one galvanised iron washers and one galvanised iron nut 150mm height 150mmdia for 11000 volts grade.
S & F in replacement HT movable link assembly with barricaded copper belt of current rating 200/400 Amps for GOD 11000 volt all as directed by Engineer-in-charge.
Supply and fix in repair of male link assembly with brass tinned contact for GOD 11000 Volt grade complete all as specified.
Supply and fix in repair of female link assembly with brass tinned contact for GOD 11000 Volt grade complete all as specified.
S & F in replacement HT fix link with tenson spring assembly with brass tinned contact for 11000 volt GOD all as directed by Engineer in Charge.
Supply and errecting in replacement true vertical position prestressed concrete poles 11 metre long 152mm x 152mm at top and 152mm x 260mm at bottom, class - 9 including painting of 05 Nos bands/ strips of 30cm wide each with two coats of synthetic enamel paint (black and white) at a distance of 30cm from the plinth block upto 1500mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) complete all as specified and directed to match the existing poles. Note :- excavation and earth work shall be measured and paid separately.
M&L for PCC 1:4:8 type D:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundation coping of poles etc.
M&L for PCC 1:3:6 type C:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundation coping of poles etc.
M&L for PCC 1:2:4 type B:2 using 40mm graded crushed stone aggreate as in foundation for pole/stay assembly foundation coping of polesincl taking down of old coping of the pole all as specified and directed by Engr-in-Charge .
Material & labour for stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length, fixed to pole with and including FI clamps 50 x 6 mm, bolt, nuts washers, GI stay rod 20 mm dia and 1800 mm long, stay bow 400 x14mm, GI steel plate 300x300x6mm, loop insulator of size 90 x 140mm clearance hole 16mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work all as shown in Electrical Plate No. 1 of SSR part - I 2009 on Page No 495 compelete all as specified and directed.(Earth work, pcc work and insulator measured and paid seperately
S & F in replacement of damaged porcelene type loop insulator capacity 11 KV with necessary nut bolts and accessories.
Labour for cutting the tree branches passing near the HT /LT OH line of width/ girth not more than 30cm upto 3 meter distance from adjacent pole or four/two pole structure all as specified and directed by EIC. Note ;- (i) Each span having 50 mtr distance approximately (ii) All cutting branches of trees shall be thrown away /burnt at approximately 200 to 500 mtr away from site. (iv) Transport shall be provided by contractor to thrown away the branches. No amount shall be paid seperately for transport. All rates are deemed to be inclusive in the quoted rates. (iii) Pruning the branches /Cutting the tree branches as when required shall be carried out with in three days after intimating by telephonically /whats app msg or letter .Failling which Rs 400/per day will be levied on the contractors as penality. (iv) Transport shall be provided by contractor to thrown away the branches/trees. No amount shall be paid seperately for transport. All rates are deemed to be inclusive in the quoted rates.
M & L lightening arrestor in replacement expulsion type for out door use complete with all fittings discharge capacity 65 KA suitable for 11000 volts including bracket, clamps, nuts, bolts washers and connection to each wire complete all as specified. Make RASHTRIA/OBLUM.
Supply & fixing in replacement ACSR conductor including stretching on OH line including binding on insulators with aluminium binding wire including jumpers and jointing all specified & directed by Engr-in-charge. Note :- (i) Weight of ACSR or all aluminium conductor drawn for OH lines is to be measured by measuring tant horizontal distance between centres of two adjacent poles and compounding the weight of conductor of that size and length and 3 % extra added for sag, jointing, jumpers and binding etc. (ii) Weight of conductor shall be calculated from tables given in the relevant I.S.
M & L for fault detection in damaged UG cable by using cable fault detector / locator vehicle mounted to a accuracy of 2 mtr for various location at Tibri mil stn of any size and type upto 11KV incl the following in quoted rate all as directed and specified and directed by Engr-in-Charge (i) Excavation & earth work in any type of strata of size 4 x2 x0.60 m to usually inspect / repair the damaged cable when and where required (ii) sand cushioning in trenches class HV, type I flat, size 300mm x 180mm x 40mm laid flat in trenches over the cable (iii) Repair the damaged cable through straight through joint kit as per existing size and made functional. (iv)The fault should be done within 3 days of time frame after informed to the contractor / contractor REP by telephonically /whats app msg or letter , Failling which Rs 1000/per day will be levied on the contractors as penality. Straight through joint kit will be measured and paid seperately in relevent items of contract.
Restreching of existing ACSR conductor of any size any type as required sag fixed on OH line & insulators/cross Arms on poles properly binding with aluminium complete all as specified and directed.
M&L in replacement GI steel earth wire continuity conductor, HT poles /cradles of different shapes of size 4mm dia all complete as specified & directed by Engr-in-Charge.
M&L in replacement for end termination indoor type heat shrinkable jointing kit suitable for 11KV cable 50 to 95 sqmm, 3 core all complete as specified & directed by Engr-in-Charge
All as per srl item No.35 here in before but 120 to 185 Sqmm, 3 core.
All as per srl item No.35 here in before but 240 to 300 Sqmm, 3 core.
M&L for end termination outdoor type heat shrinkable joint suitable for 11KV cable 50 to 95 sqmm, 3 core all as specified and directed.
All as per srl item No.38 here in before but 120 to 185 Sqmm, 3 core.
All as per srl item No.38 here in before but 240 to 300 Sqmm, 3 core.
M&L in replacement for straight through jointing Kit heat shrinkable type suitable for 11KV cable 50 sqmm 3 core to 95 sqmm 3 core all as specified and directed.
All as per srl item No.41 here in before but 120 to 185 Sqmm, 3 core.
All as per srl item No.41 here in before but 240 to 300 Sqmm, 3 core.
Supply and fixing in replacement of safe high voltage tape roll 15 mtr length complete all as specified and directed
Supply and fixing in replacement of PG clamp size 66 KV line Horizontal and Vertical type complete all as specified and directed.
Supply and fixing Male - female clamp suitable for 66 KV line insulator complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter ground level with top edge of the earth plage at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using galvanised iron strip of 25 mm x 4mm by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and the other end of the earth strip connected to main switch board protected by galvanized iron med grade pipe 40mm PCC Chamber in cement concrete 1:3:6 type C-2 & C1 cover funnel and wire mesh all as specified and directed
Supply and fix galvanised iron strip 25mm x 4mm as earthing lead fixed to wall / pole or buried in ground or drawn in pipe coml all as specifiedand directed
M & L in replacement danger notice plate for HT pole of size 20 cm x 15cm of 1.6 mm thick mild steel sheet viterious enamaled white with letter figur and conventional skull and bones "DANGER" (English, Punjabi and Hindi) in signal red colour and fixed with MS clamps made of 25mm x 3mm MS flat Iron bolts nuts complete including two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M & L Replacement of single disc assembly for tension clamps for conductor working pressure 11000 volts
M &L for preparation of old painted steel and iron surfaces and painting to 4 pole structure PCC pole of height 11 mtr any type ( double swan / single swan ) with two coats of synthetic enamel paint upto 1.5 mtr above from ground level (in white and black strip)05 Nos x30 cm wide each ) and applying two coats of alumunium paints on cross arms bracings clamps chanels etc and writing pole number with black synthetic enamel paint compl all as specified and directed
All as per Srl item No 51 here in before but two pole structure
M &L for preparation of old painted steel and iron surfaces and painting to steel structure installed at 66 KV Sub Stn and other substation and applying two coats of alumunium paints on cross arms bracings clamps chanels etccompl all as specified and directed
Material & labour for painting to panels & feeder pillar box, any sizes, installed at 66 KV Sub Stn with two coats of super enamelled paint of approved colour with spray painting machine including preparation of the surface complete all as specified and directed.
Supply & fixing in replacement of brass nut bolt washers off sizes as per samples complete all as specified and directed.
S&F in replacement the existing U/S auto battery charger suitable for charging of 12V/24 V/36V batteries all as specified and directed.
Supply & fixing of mild steel chequered plate of 5mm thick or over in thickness of Gde FE 410 WA in replacement of PCC type duct cover quality as directed by Engr -in -Charge
Supply and fixing in replacement of XLPE insulated PVC Sheathed single core Aluminium unarmoured of 11000 Volts grade cable for using as a jumper in HT overhead line whereever required of size 95 sqmm all as directec by engineer in charge
Supply and fixing in replacement of copper fuse wire capacity 25 Amps SWG 25 ALL All as specified and directed Engr in charge.
Supply and fixing in replacement of copper fuse wire capacity 10 Amps SWG 29 All as specified and directed Engr in charge.
Supply and fixing in replacement of copper fuse wire capacity 05 Amps SWG 35 All as specified and directed Engr in charge.
M & L for fire retardant / extinguishing elect insulated synthetic MAT insulation 2000 of 2.5 mm thick conforming to BIS : DOC NO ET 02 (5440) dt 30 April 2004 meeting requirments of IS 3043 IS 5216 (Part 1,2,73 ) IS 8437 and IEC 479 pub -1 tested for break down strength ,test elongation properities ,insulation,resistance efforts of acid alkaline diesel and transformer oil leakage current test fire test etc having a min width of 100 mm incl all pasting materials such as puesin chemical bound hardner ) Special PVC adhesive liquid primer etc suitable for 11000 voltage system and fixed in electrical installation compl all as specified and directed Make as approved by GE confirming to above specification.
M&L for PCC 40 MM thick PCC 1:2 :4 type B1 using 20mm graded crushed stone aggreate as in floor finished even and smooth without using extra cement incl demolistion of existing concrete complete all as specified and directed.
S & F in replacement of old power pack with minimum 2 hrs back up and input supply in 220 Volt AC and out put 24 Volts DC for HT VCB 11 kv all as specified and directed
M & L precast cement concrete RCC (1:2;4 type B1 route indicator of size 150 x150x 900 mm with 8mm dia steel reinforcement @ 100c/c both ways duly engraved HT Cable /HT JOINT /FEEDER No with two coats synthetic enamel paint first quality fixed with PCC 1:3:6 below ground level of size 30 x30x 300mm compl all as specified and directed Note Quoted unit rate is deemed to be included the necessary cost of excavation returning filling and removal etc.
M & L for two coats of cement paint through out the PCC HT pole with two coats of synthetic enamel paint upto 1.5 height above from ground level ( in white and black 5 strips of 30 cm wide each ) and applying two coats of aluminium paint on cross arms bracing clamps chanels etc and writing pole number with black synthetic enamel paint incl 3 x strip of 3 cm width of light reflective paint compl all as specified and directed
S & f in replacement of old PVC First aid box of Size 30 cm x 30cm x 20 cm incl necessary first aid material / medicine i:e burn cream bandage cotton detol pain killer tablet of 10 Nos and all as specified and directed by Engineer - in -charge
M & L for shock treatment chart coloured and writen in Hindi punjabi and english incl lamination board of size 1m x1m all as specified by Engineer - In- Charge
S& F in replacement of old unsv maintenance free dry type batteries of 2 volt of 100 AH ( as per sample / existing capacity ) compl all as specified and directed Make Amron/ Exide / Amco)
P S BUILDERS
Kaul Enterprises
INDIA ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .