Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹7.0 L
Closing Date
12 Sept 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dhinesh Kumar. S
POWERGRID CORPORATION OF INDIA LTD, SRTS-II RHQ, Singanayakanahalli, Yelahanka, Bengaluru-560064.
CONSTRUCTION OF HOSTEL BUILDING, ROADS, DRAINS, INTERNAL AND EXTERNAL ELECTRIFICATION FOR ITI COMPLEX AT PERUMBAKKAM CHENNAI UNDER CSR
SR2/NT/W-CIVIL/DOM/C00/23/05971
Open
Civil - All
Works
Chennai
₹12,500
₹7.0 L
12 Sept 2023
7 Aug 2023
14 Sept 2023
7 Aug 2023
12 Sept 2023
7 Aug 2023
ATTACHMENTS General guidelines for filling up the Attachments
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(QR), 5(A), 6, 9, 11, 12, 13, 14, 15, 17, 19, and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as per proforma provided in the Bidding Document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. This attachment is not included here.
6 Attachment 10 Guarantee Declaration: We hereby declare that Attachment-10 (Guarantee Declaration) is provided in our Second Envelope Bid.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14-IP.
7 Attachment 20, Attachment 21, Attachment 22, Attachment 23 : To be submitted as per the provisions of the Bidding Documents (Formats Attached seperately in Volume-III of Bidding Documents.
8 Attachment 24: Unequivocal consent of the proposed Sub-Contractor(s) : No specific format is provided by POWERGRID. Bidder may use their own format.
9 Attachment 25: Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1 (All partners of the Joint Venture in case of Joint Venture bids)
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971
Enter the details of the bidder below: Sole Bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 1
{as per sl. no. 1.1 OR 1.3 OR 3.0 (as applicable) of Annexure-A (BDS) of Vol-I (Conditions of Contract)}
Route 2: Manufacturer of OPGW Route 1: Installation Agency
Whether the bidder is an MSE (Micro & Small Enterprise) Route 2: Manufacturer of OPGW
Name of the Bidder 1
Address of the Bidder 2 or more
Pick date from here (mm/dd/yyyy):
NOTE: (In case of JV, all partners of the Joint Venture shall be MSEs to consider its bid as bid from MSE, JV bidder with at least one non-MSE partner (whether lead or other partner) shall not be eligible for the benefit available to the MSE bidders)
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-3 (JV) #REF! #REF!
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address : To:
0 C&M Department 1 #REF!
Name : 0 Power Grid Corporation of India Ltd., 1
Address : 0 SRTS-II,RHQ,Bangalore
This Attachment is Not Applicable
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
* applicable for Joint Venture
Date : 00-Jan-00 Printed Name : 0 #REF!
Place : 0 Designation : 0 #REF!
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-3 (QR)
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Qualifying Requirement Data)
Bidder’s Name and Address : To:
0 C&M Department
Name: 0 Power Grid Corporation of India Ltd.,
Address: 0 SRTS-II,RHQ,Bangalore
For Our Qualifying Requirements, Please refer QR
We have submitted bid as individual firm.
We have submitted bid as joint venture of following firms :
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
C Whether bidder anticipate any change in legal structure/ ownership of their organisation at present. If Yes, please enclose details of same and copy of procedural document(s) with reference to the same/ as required statutorily, as of now
1.0 GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Sole Bidder
1 Name of the Firm 0 0 0
2 Head Office/ Registered Office Address 0 0 0
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
2.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
2.1 TECHNICAL EXPERIENCE
In case of foreign entity, whether bidder have established/ commence the establishment of facility as Indian Subsidiary/ Group Company/ Joint Venture Company for manufacturing & testing of 400kV or above voltage level GIS in India (as per Companies Act 1956 or 2013 of India)
Whether bidder want to propose its above subsidiary/ Group Company/ Joint Venture Company as its associate for executing On-Shore Supply Contract
Whether Undertaking (as per enclosed format in Section-VI, Sample Forms and Procedures of bidding document) for above is enclosed with the bid
4.0 Financial Qualification Data: 1
Name of the Bidder 0
Networth Details of documentary evidence submitted in support of Qualification Data
Currency Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2018-19 No
B Turnover details:
Turnover Details of documentary evidence submitted in support of Qualification Data
Currency Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2018-2019
Average Annual Turnover for best Three Years is
C Liquid Assets
Currency (INR) LA
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Networth (INR) Details of documentary evidence submitted in support of Qualification Data
Currency Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2018-2019 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
B Turnover details:
Turnover Details of documentary evidence submitted in support of Qualification Data
Currency Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2018-19 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
C Liquid Assets
Currency LA Equivalent US$ (in Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Networth Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Currency Networth (in Millions)
Sl No Financial year
Do you have audited results for FY 2012-13 Yes
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
B Turnover details:
Turnover Equivalent US$ (in Million) exchange rate* Details of documentary evidence submitted in support of Qualification Data
Currency Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2012-13 Yes
Average Annual Turnover for best Three Years is
*(Indicate the rate(s) of exchnage against US Dollar at the end of each year, which have been used for arriving the amount at equivalent US Dollar.)
C Liquid Assets
Currency LA Equivalent US$ (in Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
4.0 Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
3.0 a) IIn case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet collectively the complete requirements stipulated at para 1.0 and 2.0 (b) & (c) above. Further, the partner(s) of JV must also meet the following minimum criteria: i. All the partners of the JV shall meet individually the Financial Position criteria given at 2.0 (a) above. ii. The Lead Partner shall meet, not less than 40% of the minimum Financial Position criteria given at para 2.0 (b) & (c) iii. Each of the other partner(s) individually shall meet not less than 25% of the minimum Financial Position criteria given at para 2.0 (b) & (c) above The figure of average annual turnover and liquid assets/credit facilities for each of the partners of the JV shall be added together to determine the JV’s compliance with the minimum qualifying criteria set out in Para 2.0 (b) & (c) above. b) However, for a JV to be qualified, the partners of JV must also meet the following minimum criteria: i. One of the partner(s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 1.0 above ii. The remaining partner(s) must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays@ of 345kVor above voltage level in one (1) substation or switchyard during the last seven (7) years in India and these bays@ must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above. Note :- (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark.
The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above.
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
5.2 The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
Audited balance sheet and income statements for the last five years as per the following:
For 0 For 0 For 0
A Audited Balance Sheet and Income Statements enclosed
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-4
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
We hereby certify that equipment and materials to be supplied are produced in [Enter the name of country where from equipments & material shall be supplied] eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Enter the name of country where from equipments & material shall be supplied] eligible source country.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
country. country. [Enter the name of country where from equipments & material shall be supplied] [Enter the name of country where from equipments & material shall be supplied]
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-4 (A)
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-4 (A)
(List of Special Maintenance Tools & Tackles)
S.No. For Equipment Item Description Unit Quantity
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-5
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
We hereby furnish the details of the all major items of supply or services i.e. items, whose price is more than 10% of the Bid Price, we propose to buy for the purpose of furnishing and installation of the subject :
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
2. We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-5A
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
1. We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the package. i.e.,Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Sample Forms and Procedures (FORMS), Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-5A
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-6
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Reason for change The change in Bid Prices if the deviation is withdrawn and the Bidder conforms to the Specifications
Any proposed deviation will be applicable only for the bidder whose bid is substantially responsive in accordance with Clause 22, Section ITB, Vol. I of the bidding documents. If a bid is not substantially responsive, it will be rejected and may not subsequently be made responsive by the bidder by correction of the non-conformity.
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-6
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 Attachment-7
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Details of Alternative Bid)
Bidder’s Name and Address (Lead Partner) : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
No Alternative Bid
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-7
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Work Completion Schedule)
Bidder’s Name and Address : To
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
No Alternative Bid
Date : 00-Jan-00 Printed Name: 0
Place : 0 Designation: 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-9
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Work Completion Schedule)
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject package i.e., Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
1 Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR We hereby declare that the completion Schedule shall be followed by us in line with the bid documents
2 Procurement of equipment/ components & assembly a) commencement
3 Type Tests a) commencement
4 Manufacturing a) commencement
5 Shipments & Delivery a) commencement
6 Establishment of site office
7 Installation at Site a) commencement
8 Testing & Pre-commissioning a) commencement
9 Trial Operation a) commencement
b) completion 18
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation: 0
Note: Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-10
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Guarantee Declaration)
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
We confirm that the equipments offered shall have minimum (or a maximum, as the case may be) performance specified in Technical Specifications. We further guarantee the performance/ efficency of the equipments in response to the Technical Specifications
We declare that the ratings, performance figures and availability of the system furnished by us for subject Package covered under this specification are guaranteed by us. In particular, we declare that the 1) 10MVA, (220/V3)/(132/V3) kV, 1-phase Autotransformer; 2) 160MVA, 220/132/33 KV, 3-phase Autotransformer as per scope of package) offered under this package shall meet the maximum loss requirement as stipulated in Technical Specifications
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-11
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Note: The information in similar format should be furnished for each partner of joint venture in case of joint venture bid.
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-11
(Information regarding Ex-employees of POWERGRID in our Organisation)
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-11
(Information regarding Ex-employees of POWERGRID in our Organisation)
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : 00-Jan-00 Printed Name : 0
Place : 00-Jan-00 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-12
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No.-2
0 Gurgaon (Haryana) - 122001
Firm Price Basis
Sl. No. Name of Materials/Labour Value of co-efficient Name of the published index Value of index as 30 days prior to date set for opening of bids
In accordance with Clause 2, Appendix-2, Form of Contract Agreement, Section-VI; Forms. Volume-I
A) For Equipment Ex-Works Price Component
I. Circuit Breaker
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
II Current Transformer
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.65 to 0.73 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
II Insulating Oil
S.N. Name of Materials/Labour Value of Coefficient Name of the published index Value of index as 30 days prior to date set for opening of bids
III Capacitive VoltageTransformer
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
IV Surge Arrester
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
V PVC/XLPE Insulated Power and Control Cable
a) a=PVC Compound 0.15
b) Published Price of Metal IEEMA
i) Aluminium per MT IEEMA
ii) Copper per MT IEEMA
c) Weight in MT of Metal per kM (Size wise)
VI Substation Structures
i) Lattice Steel Structures & Pipe Structures (including bolts & nuts, washers & foundation bolts)
a) Raw Materials
i) a=Structural steel 0.58 JPC Market Price (Retail) for average Price of Steel Angles of size 50 x 50 x 6 mm of all cities in Rs./MT as published by Joint Plant Committee(JPC).
ii) b=Electrolytic Zinc 0.16 IEEMA
b) Labour 0.11 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
VIII. Series Reactor [ 420 kV, 12 ohm, 2500A, 1-ph air core dry type Series Reactor]
a) Raw Material Copper(a)
i) Aluminium(a) Aluminium(a)
b) Labour I= 0.85 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The value of coefficient for raw materials: a=0.65 to 0.73 and value of coefficient for labour shall be between 0.12 and 0.20, so that sum of all the coefficients including labour shall be a+l=0.85
B. For Installation Price Component
I Installation price component (including Civil works but excluding ‘supply & placement of reinforcement steel’ and ‘concreting’)
i) Labour I= 0.80 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
II Supply & Placement of Reinforcement Steel
i) HSD 0.10 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour I= 0.05 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
iii) Manufacture of Basic Metals 0.65 Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
III For Concereting
i) HSD 0.20 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour I= 0.10 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
iii) Manufacture of cement, lime and plaster 0.30 Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in)
iv) Cutting, shaping and finishing of stone 0.20 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-13
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Declaration regarding Social Accountability)
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-14
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
Integrity Pact is annexed herewith this Volume.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited 0 0
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as 0 0
"POWERGRID", 0 0
having its Registered Office at
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR, RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR, RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971. POWERGRID values full compliance with all relevant laws of the land, rules, regulations, economic use of resources, and of fairness / transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personnel interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons.
(2) If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC / PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID’s Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
during his participation in the tender process and during the contract execution :
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or during the execution of the contract
b) The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC / IPC Act.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/information in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
g) The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban /blacklist the Bidder/Contractor in line with POWERGRID’s policy for “Black-Listing of Firms / Banning of Business”. The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID’s policies.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
(2) The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He / She reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his / her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEMs information as sought by him / her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on ’Non-Disclosure of Confidential Information’ and of ‘Absence of Conflict of Interest’. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he / she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC / IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter.
(10) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
(6) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(7) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 Attachment-15
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion:
Services Portion:
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made 0
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. Please refer remarks at the end of the attachment. No
3. (c ) If 3(b) is ‘Yes’ please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3. (d ) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment order 2018 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached.
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
6 PF Registration No. of the Company
7 PF Regional Office covered (with Address)
8 Name of Contact Person
9 Contact Details
10 Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Saving Account
11 9 digit MICR code printed at bottom in middle, next to cheque no.
12 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-16
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Additional Information) 1
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
In support of the additional information required as per ITB Sub-Clause 9.3 (q) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(q)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder : 0 1
Name of the Banker by whom certificate issued 1
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
(iii) As per para BDS/ITB clause 9.3 (q), Bidder shall furnish the details of their Provident Fund Code Number
Sl. No. Name of the Bidders/JV Partners Provident Fund Code Number Details
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(q)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years.
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Intehrity Pact that occured in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-17
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
Dear Sirs, 1. We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us. 2. We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-19
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof, forming part of our First Envelope :
(i) there are no discrepancies/inconsistencies and deviations/omissions/ reservations to the Bidding Documents, in the Second Envelope bid;
We also confirm that in case any discrepancies/ inconsistencies and deviations/ omissions/ reservations, as referred to in para (i) and (ii) above, is observed in the Second Envelope, the same shall be deemed as withdrawn/rectified without any financial implication, whatsoever to POWERGRID. However, in case of any arithmetical errors, the same shall be governed as per the provision of ITB Sub-Clause 27.2 read in conjunction with BDS
Date 0-Jan-1900 Printed Name 0
Place 0 Designation 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-18A
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(Declaration regarding supply of 400kV Class GIS Circuit Breaker bay from Subsidiary/ Group Company /Joint Venture Company in India of the Foreign Bidder)
Bidder’s Name and Address : To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
1 We have read the provisions in the Bidding Documents regarding manufacture and supply of 400kV Class GIS Circuit Breaker bay from the manufacturing facilities of our Subsidiary / Group Company / Joint Venture Company in India pursuant to GCC Sub-Clause 5.1. Accordingly, as per Qualification requirement specified in Annexure-A (BDS) and ITB Clause 11.1 as modified in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby declare that:
*We propose to supply only One (01) number 400kV class GIS Circuit Breaker bay from the manufacturing facilities of our Subsidiary / Group Company / Joint Venture Company in India within the Time for Completion, pursuant to GCC Sub-Clause 5.1. FALSE
*We propose to supply more than One (01) number (i.e, number) of 400kV GIS Circuit Breaker bay from the Subsidiary/ Group Company / Joint Venture Company in India, as our Indian Subsidiary/ Group Company / Joint Venture Company complies with the requirement stipulated in Qualification requirement specified in Annexure-A (BDS) and ITB Clause 11.1 as modified in Section BDS. In support of the compliance to requirements specified in ITB Clause 11.1 as modified in Section BDS and GCC Sub-Clause 5.1, we furnish enclosed herewith the following documents: TRUE Please insert the number of 400kV GIS Circuit Breaker bay proposed to be supplied from the Subsidiary/ Group Company / Joint Venture Company in India, as our Indian Subsidiary/ Group Company / Joint Venture Company
*Choose whichever is applicable
Date 0 Printed Name 0
Place 0 Designation 0
*We propose to supply more than One (01) number (i.e, number) of 400kV GIS Circuit Breaker bay from the Subsidiary/ Group Company / Joint Venture Company in India, as our Indian Subsidiary/ Group Company / Joint Venture Company complies with the requirement stipulated in Qualification requirement specified in Annexure-A (BDS) and ITB Clause 11.1 as modified in Section BDS. In support of the compliance to requirements specified in ITB Clause 11.1 as modified in Section BDS and GCC Sub-Clause 5.1, we furnish enclosed herewith the following documents:
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-23-A
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
Declaration by the Bidder in line with Annexure-A (BDS) regarding already having manufacturing & testing facilities for 400kV or above voltage level GIS in India as on the originally scheduled date of bid opening.
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
We hereby confirm that we have already incorporated Subsidiary Company */Group Company * /Joint Venture Company * as per Companies Act of India, in line with GCC clause 5.1 to manufacture 400KV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned in Annexure-A (BDS).
We further confirm that the said Subsidiary Company */Group Company * /Joint Venture Company * has manufacturing & testing facilities for 400kV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned in Annexure-A (BDS).
Further, we are furnishing the requisite document in support of the above which are attached herewith.
* Stike out which ever is not applicable
Date 0-Jan-1900 Printed Name 0
Place 0 Designation 0
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 ATTACHMENT-23-B
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
Declaration by the Bidder in line with Annexure-A (BDS) regarding commencement of construction activities for establishment of 400kV or above voltage level GIS manufacturing and testing facilities in India as on the originally scheduled date of bid opening.
Bidder’s Name and Address : To:
0 C&M Department
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 SRTS-II,RHQ,Bangalore
We hereby confirm that we have already incorporated Subsidiary Company */Group Company * /Joint Venture Company * as per Companies Act of India, in line with GCC clause 5.1 to manufacture 400KV or above voltage level GIS in India and have commenced the Construction activities for establishment of manufacturing & testing facilities for 400kV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned in Annexure-A (BDS)
Regarding incorporation of Subsidiary Company */Group Company * /Joint Venture Company * in India and Commencement of Construction activities, we here by declare as under :
a) Our Subsidiary Company */Group Company * /Joint Venture Company * has been incorporated on ___________________ as per Companies Act of India (Documentary Evidence is Attached herewith).
b) Land is in legal and physical possession (Documentary evidence is attached herewith)
c) All Building designs, ordering of civil works have been completed and civil work at site have commenced (Documentary evidence is attached herewith)
d) Purchase order for major long delivery testing equipment have been placed with delivery and commissioning schedule (Documentary evidence is attached herewith)
e) Action plan for availability of trained manpower to take up manufacturing and testing of GIS module is attached herewith.
* Stike out which ever is not applicable
Date 0-Jan-1900 Printed Name 0
Place 0 Designation 0
Before filling up the Bid Form, the Bidder is required to fill up the details as under :
1 Tick whichever is applicable:
2 Enter Details of Amendments:
Amendments to Bidding Documents issued:
4 Currency INR Amount
5 Validity in days
6* In case the Bidder is MSE, then insert the Designated Authority under GoI with which they are Registered: ghtg
* applicable for MSE only
RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 Bid Form (First Envelope) 1 st 1 January 1 one
2 nd 2 February 2 two
BID FORM (First Envelope) 3 rd 3 March 3 three
4 th 4 April 4 four
Bid Proposal Ref. No.: 5 th 5 May 5 five
Date : 00-Jan-00 7 th 0 6 June 7 seven
8 th 1 7 July 8 eight
To: 9 th January 8 August 9 nine
C&M Department 10 th 1900 9 September 10 ten
Power Grid Corporation of India Ltd., 11 th 10 October 11 eleven
SRTS-II,RHQ,Bangalore 12 th 11 November 12 twelve
0 13 th 12 December 13 thirteen
14 th Zero 14 fourteen
15 th () 15 fifteen
Name of Contract : Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR RefNo/Specification No: SRTS-II/C&M/WC-3660/NIT-218/2023 - SR2/NT/W-CIVIL/DOM/C00/23/05971 the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently).0 16 th 16 sixteen
Dear Ladies and/or Gentlemen, 17 th 17 seventeen
1.0 the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 0 18 th 18 eighteen
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2 19 th 19 nineteen
2.0 Attachments to the Bid Form (First Envelope) 20 th 20 twenty
2.1 In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments to the Bid Form : 21 st
(a) Attachment 1: Bid Security in the form of for a sum of INR /- () initially valid for a period of () days from the date set for opening of bids. Bank Draft 22 th
OR Enter details here.
Online Payment Acknowledgement towards Bid Security for a sum of ................................................ (name of currency and amount in words and figures) Pay Order
OR documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 13.1 of ITB, Section-II." Banks certified Cheque
(b) Attachment 2: Attachment 2: A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. *Further the requisite deed of Joint Undertaking as per stipulated qualification requirement in Annexure-A (BDS) has also been furnished as per your format. * Delete if not applicable A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee 23 th
(c) Attachment 3: The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3(c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents [Attachment – 3(QR)]. 24 th
* Further, the required deed of Joint Venture Agreement signed by us and our Partners has also been furnished as per your format [Attachment – 3(JV)].
(d) Attachment 4: The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facility offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4 . Moreover, a list of Special Tools & Tackles to be furnished by us, the cost of which is included in our Bid Price, is also enclosed as per your format as Attachment- 4A. 25 th
(e) Attachment 5: The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A: (Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises): The details of the items, components, raw material, services which is proposed to bought/availed from Micro and Small Enterprises for the purpose of completion of works
(g) Attachment 6: The variation and deviations from the requirements of the Conditions of Contract, Bid Data Sheet and other commercial conditions, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter-alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7: The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. [NOT APPLICABLE] 28 th
(i) Attachment 8: Manufacturer’s Authorisation Forms 29 th
(j) Attachment 9: Work Completion Schedule
(k) Attachment 10: Guarantee Declaration
(l) Attachment 11: Information regarding ex-employees of Employer in our firm
(m) Attachment 12: Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents
(n) Attachment 13: Declaration regarding Social Accountability
(o) Attachment 14: Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15: Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16: Additional information
(r) Attachment 17: Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18: Safety Pact
(t) Attachment 19: Declaration
(u) Attachment 20: Declaration of Key Managerial Person jointly with Power of Attorney holder is attached herewith
(v) Attachment 21: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
(w) Attachment 22: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
(x) Attachment 23: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
(y) Attachment 24: Bid security declaration
(z) Attachment 25: Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1 (All partners of the Joint Venture in case of Joint Venture bids)
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
5.0 Construction of the Contract
, whose capacity, capability and experience are enclosed with our Bid as our Associate(s) for the purpose of executing the ‘Second Contract’ and / or the ‘Third Contract’ and written unequivocal consent of the above mentioned proposed Associate(s) to work as your independent Contractor, on the same terms and conditions as offered by us to you in this bid, is also enclosed with the Bid Form. We shall, however, be overall responsible for the execution of all the three Contracts.
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, In-transit insurance, unloading, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 5.1 Contractor’s Responsibilities
(d) GCC 8 Terms of Payment
(e) GCC 9.3 Performance Security
(f) GCC 10 Taxes and Duties
(g) GCC 21.2 Completion Time Guarantee
(h) GCC 22 Defect Liability
(i) GCC 23 Functional Guarantee
(j) GCC 25 Patent Indemnity
(k) GCC 26 Limitation of Liability
(l) GCC 38 Settlement of Disputes
(m) GCC 39 Arbitration
(n) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us shall make our bid non-responsive as per provision of bidding documents and rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work on Facilities immediately upon your Notification of Award to us, and to achieve Completion within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide an Advance Payment Security and Performance Security(ies) in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of Six (06) months from the date fixed for submission of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
*12.0 (for Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 1
13.0 We are a Micro and Small Enterprise (MSE) registered with , a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012. 0 2 2
13.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain
Yours faithfully,
For and on behalf of : 0
Date : 00 January 1900 Printed Name: 0
Place : 00-Jan-00 Designation : 0
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
(State/Province to be indicated)
Name of Principal Officer :
Address of Principal Officer :
USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only EURO Four Thousand Nine Hundred Sixty Only RMB Ten Thousand Three Hundred Fifty Two Only INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only USD 155885/- + EURO 4960/- + RMB 10352/- + INR 691647/-
USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only plus EURO Four Thousand Nine Hundred Sixty Only plus RMB Ten Thousand Three Hundred Fifty Two Only plus INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only
85 Eighty Five 60 Sixty 52 Fifty Two 47 Forty Seven
8 Eight Hundred 9 Nine Hundred 3 Three Hundred 6 Six Hundred
55 Fifty Five Thousand 4 Four Thousand 10 Ten Thousand 91 Ninety One Thousand 0 0 0 0 0 plus
1 One Lac 0 0 6 Six Lac 0 0 0 0 1
1 One 1 One 1 One 1 One 0 0 1 0 1
2 Two 2 Two 2 Two 2 Two 0 0 1 1 0
3 Three 3 Three 3 Three 3 Three 0 0 1 1 1
4 Four 4 Four 4 Four 4 Four 0 1 0 0 0
5 Five 5 Five 5 Five 5 Five 0 1 0 0 1
6 Six 6 Six 6 Six 6 Six 0 1 0 1 0
7 Seven 7 Seven 7 Seven 7 Seven 0 1 0 1 1
8 Eight 8 Eight 8 Eight 8 Eight 0 1 1 0 0
9 Nine 9 Nine 9 Nine 9 Nine 0 1 1 0 1
10 Ten 10 Ten 10 Ten 10 Ten 0 1 1 1 0
11 Eleven 11 Eleven 11 Eleven 11 Eleven 1 1 1 1 1 USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only plus EURO Four Thousand Nine Hundred Sixty Only plus RMB Ten Thousand Three Hundred Fifty Two Only plus INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only
12 Twelve 12 Twelve 12 Twelve 12 Twelve
13 Thirteen 13 Thirteen 13 Thirteen 13 Thirteen
14 Fourteen 14 Fourteen 14 Fourteen 14 Fourteen
15 Fifteen 15 Fifteen 15 Fifteen 15 Fifteen
16 Sixteen 16 Sixteen 16 Sixteen 16 Sixteen 0 0 0 0 0 +
17 Seventeen 17 Seventeen 17 Seventeen 17 Seventeen 0 0 0 0 1 /- +
18 Eighteen 18 Eighteen 18 Eighteen 18 Eighteen 0 0 0 1 0 /-
19 Nineteen 19 Nineteen 19 Nineteen 19 Nineteen 0 0 0 1 1
20 Twenty 20 Twenty 20 Twenty 20 Twenty 0 0 1 0 0
21 Twenty One 21 Twenty One 21 Twenty One 21 Twenty One 0 0 1 0 1
22 Twenty Two 22 Twenty Two 22 Twenty Two 22 Twenty Two 0 0 1 1 0
23 Twenty Three 23 Twenty Three 23 Twenty Three 23 Twenty Three 0 0 1 1 1
24 Twenty Four 24 Twenty Four 24 Twenty Four 24 Twenty Four 0 1 0 0 0
25 Twenty Five 25 Twenty Five 25 Twenty Five 25 Twenty Five 0 1 0 0 1
26 Twenty Six 26 Twenty Six 26 Twenty Six 26 Twenty Six 0 1 0 1 0
27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 0 1 0 1 1
28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 0 1 1 0 0
29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 0 1 1 0 1
30 Thirty 30 Thirty 30 Thirty 30 Thirty 0 1 1 1 0
31 Thirty One 31 Thirty One 31 Thirty One 31 Thirty One 1 1 1 1 1 USD 155885/- + EURO 4960/- + RMB 10352/- + INR 691647/-
32 Thirty Two 32 Thirty Two 32 Thirty Two 32 Thirty Two
33 Thirty Three 33 Thirty Three 33 Thirty Three 33 Thirty Three
34 Thirty Four 34 Thirty Four 34 Thirty Four 34 Thirty Four
35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr
36 Thirty Six 36 Thirty Six 36 Thirty Six 36 Thirty Six
37 Thirty Seven 37 Thirty Seven 37 Thirty Seven 37 Thirty Seven
38 Thirty Eight 38 Thirty Eight 38 Thirty Eight 38 Thirty Eight
39 Thirty Nine 39 Thirty Nine 39 Thirty Nine 39 Thirty Nine
40 Forty 40 Forty 40 Forty 40 Forty
41 Forty One 41 Forty One 41 Forty One 41 Forty One
42 Forty Two 42 Forty Two 42 Forty Two 42 Forty Two
43 Forty Three 43 Forty Three 43 Forty Three 43 Forty Three
44 Forty Four 44 Forty Four 44 Forty Four 44 Forty Four
45 Forty Five 45 Forty Five 45 Forty Five 45 Forty Five
46 Forty Six 46 Forty Six 46 Forty Six 46 Forty Six
47 Forty Seven 47 Forty Seven 47 Forty Seven 47 Forty Seven
48 Forty Eight 48 Forty Eight 48 Forty Eight 48 Forty Eight
49 Forty Nine 49 Forty Nine 49 Forty Nine 49 Forty Nine
50 Fifty 50 Fifty 50 Fifty 50 Fifty
51 Fifty One 51 Fifty One 51 Fifty One 51 Fifty One
52 Fifty Two 52 Fifty Two 52 Fifty Two 52 Fifty Two
53 Fifty Three 53 Fifty Three 53 Fifty Three 53 Fifty Three
54 Fifty Four 54 Fifty Four 54 Fifty Four 54 Fifty Four
55 Fifty Five 55 Fifty Five 55 Fifty Five 55 Fifty Five
56 Fifty Six 56 Fifty Six 56 Fifty Six 56 Fifty Six
57 Fifty Seven 57 Fifty Seven 57 Fifty Seven 57 Fifty Seven
58 Fifty Eight 58 Fifty Eight 58 Fifty Eight 58 Fifty Eight
59 Fifty Nine 59 Fifty Nine 59 Fifty Nine 59 Fifty Nine
60 Sixty 60 Sixty 60 Sixty 60 Sixty
61 Sixty One 61 Sixty One 61 Sixty One 61 Sixty One
62 Sixty Two 62 Sixty Two 62 Sixty Two 62 Sixty Two
63 Sixty Three 63 Sixty Three 63 Sixty Three 63 Sixty Three
64 Sixty Four 64 Sixty Four 64 Sixty Four 64 Sixty Four
65 Sixty Five 65 Sixty Five 65 Sixty Five 65 Sixty Five
66 Sixty Six 66 Sixty Six 66 Sixty Six 66 Sixty Six
67 Sixty Seven 67 Sixty Seven 67 Sixty Seven 67 Sixty Seven
68 Sixty Eight 68 Sixty Eight 68 Sixty Eight 68 Sixty Eight
69 Sixty Nine 69 Sixty Nine 69 Sixty Nine 69 Sixty Nine
70 Seventy 70 Seventy 70 Seventy 70 Seventy
71 Seventy One 71 Seventy One 71 Seventy One 71 Seventy One
72 Seventy Two 72 Seventy Two 72 Seventy Two 72 Seventy Two
73 Seventy Three 73 Seventy Three 73 Seventy Three 73 Seventy Three
74 Seventy Four 74 Seventy Four 74 Seventy Four 74 Seventy Four
75 Seventy Five 75 Seventy Five 75 Seventy Five 75 Seventy Five
76 Seventy Six 76 Seventy Six 76 Seventy Six 76 Seventy Six
77 Seventy Seven 77 Seventy Seven 77 Seventy Seven 77 Seventy Seven
78 Seventy Eight 78 Seventy Eight 78 Seventy Eight 78 Seventy Eight
79 Seventy Nine 79 Seventy Nine 79 Seventy Nine 79 Seventy Nine
80 Eighty 80 Eighty 80 Eighty 80 Eighty
81 Eighty One 81 Eighty One 81 Eighty One 81 Eighty One
82 Eighty Two 82 Eighty Two 82 Eighty Two 82 Eighty Two
83 Eighty Three 83 Eighty Three 83 Eighty Three 83 Eighty Three
84 Eighty Four 84 Eighty Four 84 Eighty Four 84 Eighty Four
85 Eighty Five 85 Eighty Five 85 Eighty Five 85 Eighty Five
86 Eighty Six 86 Eighty Six 86 Eighty Six 86 Eighty Six
87 Eighty Seven 87 Eighty Seven 87 Eighty Seven 87 Eighty Seven
88 Eighty Eight 88 Eighty Eight 88 Eighty Eight 88 Eighty Eight
89 Eighty Nine 89 Eighty Nine 89 Eighty Nine 89 Eighty Nine
90 Ninety 90 Ninety 90 Ninety 90 Ninety
91 Ninety One 91 Ninety One 91 Ninety One 91 Ninety One
92 Ninety Two 92 Ninety Two 92 Ninety Two 92 Ninety Two
93 Ninety Three 93 Ninety Three 93 Ninety Three 93 Ninety Three
94 Ninety Four 94 Ninety Four 94 Ninety Four 94 Ninety Four
95 Ninety Five 95 Ninety Five 95 Ninety Five 95 Ninety Five
96 Ninety Six 96 Ninety Six 96 Ninety Six 96 Ninety Six
97 Ninety Seven 97 Ninety Seven 97 Ninety Seven 97 Ninety Seven
98 Ninety Eight 98 Ninety Eight 98 Ninety Eight 98 Ninety Eight
99 Ninety Nine 99 Ninety Nine 99 Ninety Nine 99 Ninety Nine
100 One Hundred 100 One Hundred 100 One Hundred 100 One Hundred
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only EURO Four Thousand Nine Hundred Sixty Only RMB Ten Thousand Three Hundred Fifty Two Only INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only USD 155885/- + EURO 4960/- + RMB 10352/- + INR 691647/-
USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only plus EURO Four Thousand Nine Hundred Sixty Only plus RMB Ten Thousand Three Hundred Fifty Two Only plus INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only
85 Eighty Five 60 Sixty 52 Fifty Two 47 Forty Seven
8 Eight Hundred 9 Nine Hundred 3 Three Hundred 6 Six Hundred
55 Fifty Five Thousand 4 Four Thousand 10 Ten Thousand 91 Ninety One Thousand 0 0 0 0 0 plus
1 One Lac 0 0 6 Six Lac 0 0 0 0 1
1 One 1 One 1 One 1 One 0 0 1 0 1
2 Two 2 Two 2 Two 2 Two 0 0 1 1 0
3 Three 3 Three 3 Three 3 Three 0 0 1 1 1
4 Four 4 Four 4 Four 4 Four 0 1 0 0 0
5 Five 5 Five 5 Five 5 Five 0 1 0 0 1
6 Six 6 Six 6 Six 6 Six 0 1 0 1 0
7 Seven 7 Seven 7 Seven 7 Seven 0 1 0 1 1
8 Eight 8 Eight 8 Eight 8 Eight 0 1 1 0 0
9 Nine 9 Nine 9 Nine 9 Nine 0 1 1 0 1
10 Ten 10 Ten 10 Ten 10 Ten 0 1 1 1 0
11 Eleven 11 Eleven 11 Eleven 11 Eleven 1 1 1 1 1 USD One Lac Fifty Five Thousand Eight Hundred Eighty Five Only plus EURO Four Thousand Nine Hundred Sixty Only plus RMB Ten Thousand Three Hundred Fifty Two Only plus INR Six Lac Ninety One Thousand Six Hundred Forty Seven Only
12 Twelve 12 Twelve 12 Twelve 12 Twelve
13 Thirteen 13 Thirteen 13 Thirteen 13 Thirteen
14 Fourteen 14 Fourteen 14 Fourteen 14 Fourteen
15 Fifteen 15 Fifteen 15 Fifteen 15 Fifteen
16 Sixteen 16 Sixteen 16 Sixteen 16 Sixteen 0 0 0 0 0 +
17 Seventeen 17 Seventeen 17 Seventeen 17 Seventeen 0 0 0 0 1 /- +
18 Eighteen 18 Eighteen 18 Eighteen 18 Eighteen 0 0 0 1 0 /-
19 Nineteen 19 Nineteen 19 Nineteen 19 Nineteen 0 0 0 1 1
20 Twenty 20 Twenty 20 Twenty 20 Twenty 0 0 1 0 0
21 Twenty One 21 Twenty One 21 Twenty One 21 Twenty One 0 0 1 0 1
22 Twenty Two 22 Twenty Two 22 Twenty Two 22 Twenty Two 0 0 1 1 0
23 Twenty Three 23 Twenty Three 23 Twenty Three 23 Twenty Three 0 0 1 1 1
24 Twenty Four 24 Twenty Four 24 Twenty Four 24 Twenty Four 0 1 0 0 0
25 Twenty Five 25 Twenty Five 25 Twenty Five 25 Twenty Five 0 1 0 0 1
26 Twenty Six 26 Twenty Six 26 Twenty Six 26 Twenty Six 0 1 0 1 0
27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 27 Twenty Seven 0 1 0 1 1
28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 28 Twenty Eight 0 1 1 0 0
29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 29 Twenty Nine 0 1 1 0 1
30 Thirty 30 Thirty 30 Thirty 30 Thirty 0 1 1 1 0
31 Thirty One 31 Thirty One 31 Thirty One 31 Thirty One 1 1 1 1 1 USD 155885/- + EURO 4960/- + RMB 10352/- + INR 691647/-
32 Thirty Two 32 Thirty Two 32 Thirty Two 32 Thirty Two
33 Thirty Three 33 Thirty Three 33 Thirty Three 33 Thirty Three
34 Thirty Four 34 Thirty Four 34 Thirty Four 34 Thirty Four
35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr 35 Thirty Fivr
36 Thirty Six 36 Thirty Six 36 Thirty Six 36 Thirty Six
37 Thirty Seven 37 Thirty Seven 37 Thirty Seven 37 Thirty Seven
38 Thirty Eight 38 Thirty Eight 38 Thirty Eight 38 Thirty Eight
39 Thirty Nine 39 Thirty Nine 39 Thirty Nine 39 Thirty Nine
40 Forty 40 Forty 40 Forty 40 Forty
41 Forty One 41 Forty One 41 Forty One 41 Forty One
42 Forty Two 42 Forty Two 42 Forty Two 42 Forty Two
43 Forty Three 43 Forty Three 43 Forty Three 43 Forty Three
44 Forty Four 44 Forty Four 44 Forty Four 44 Forty Four
45 Forty Five 45 Forty Five 45 Forty Five 45 Forty Five
46 Forty Six 46 Forty Six 46 Forty Six 46 Forty Six
47 Forty Seven 47 Forty Seven 47 Forty Seven 47 Forty Seven
48 Forty Eight 48 Forty Eight 48 Forty Eight 48 Forty Eight
49 Forty Nine 49 Forty Nine 49 Forty Nine 49 Forty Nine
50 Fifty 50 Fifty 50 Fifty 50 Fifty
51 Fifty One 51 Fifty One 51 Fifty One 51 Fifty One
52 Fifty Two 52 Fifty Two 52 Fifty Two 52 Fifty Two
53 Fifty Three 53 Fifty Three 53 Fifty Three 53 Fifty Three
54 Fifty Four 54 Fifty Four 54 Fifty Four 54 Fifty Four
55 Fifty Five 55 Fifty Five 55 Fifty Five 55 Fifty Five
56 Fifty Six 56 Fifty Six 56 Fifty Six 56 Fifty Six
57 Fifty Seven 57 Fifty Seven 57 Fifty Seven 57 Fifty Seven
58 Fifty Eight 58 Fifty Eight 58 Fifty Eight 58 Fifty Eight
59 Fifty Nine 59 Fifty Nine 59 Fifty Nine 59 Fifty Nine
60 Sixty 60 Sixty 60 Sixty 60 Sixty
61 Sixty One 61 Sixty One 61 Sixty One 61 Sixty One
62 Sixty Two 62 Sixty Two 62 Sixty Two 62 Sixty Two
63 Sixty Three 63 Sixty Three 63 Sixty Three 63 Sixty Three
64 Sixty Four 64 Sixty Four 64 Sixty Four 64 Sixty Four
65 Sixty Five 65 Sixty Five 65 Sixty Five 65 Sixty Five
66 Sixty Six 66 Sixty Six 66 Sixty Six 66 Sixty Six
67 Sixty Seven 67 Sixty Seven 67 Sixty Seven 67 Sixty Seven
68 Sixty Eight 68 Sixty Eight 68 Sixty Eight 68 Sixty Eight
69 Sixty Nine 69 Sixty Nine 69 Sixty Nine 69 Sixty Nine
70 Seventy 70 Seventy 70 Seventy 70 Seventy
71 Seventy One 71 Seventy One 71 Seventy One 71 Seventy One
72 Seventy Two 72 Seventy Two 72 Seventy Two 72 Seventy Two
73 Seventy Three 73 Seventy Three 73 Seventy Three 73 Seventy Three
74 Seventy Four 74 Seventy Four 74 Seventy Four 74 Seventy Four
75 Seventy Five 75 Seventy Five 75 Seventy Five 75 Seventy Five
76 Seventy Six 76 Seventy Six 76 Seventy Six 76 Seventy Six
77 Seventy Seven 77 Seventy Seven 77 Seventy Seven 77 Seventy Seven
78 Seventy Eight 78 Seventy Eight 78 Seventy Eight 78 Seventy Eight
79 Seventy Nine 79 Seventy Nine 79 Seventy Nine 79 Seventy Nine
80 Eighty 80 Eighty 80 Eighty 80 Eighty
81 Eighty One 81 Eighty One 81 Eighty One 81 Eighty One
82 Eighty Two 82 Eighty Two 82 Eighty Two 82 Eighty Two
83 Eighty Three 83 Eighty Three 83 Eighty Three 83 Eighty Three
84 Eighty Four 84 Eighty Four 84 Eighty Four 84 Eighty Four
85 Eighty Five 85 Eighty Five 85 Eighty Five 85 Eighty Five
86 Eighty Six 86 Eighty Six 86 Eighty Six 86 Eighty Six
87 Eighty Seven 87 Eighty Seven 87 Eighty Seven 87 Eighty Seven
88 Eighty Eight 88 Eighty Eight 88 Eighty Eight 88 Eighty Eight
89 Eighty Nine 89 Eighty Nine 89 Eighty Nine 89 Eighty Nine
90 Ninety 90 Ninety 90 Ninety 90 Ninety
91 Ninety One 91 Ninety One 91 Ninety One 91 Ninety One
92 Ninety Two 92 Ninety Two 92 Ninety Two 92 Ninety Two
93 Ninety Three 93 Ninety Three 93 Ninety Three 93 Ninety Three
94 Ninety Four 94 Ninety Four 94 Ninety Four 94 Ninety Four
95 Ninety Five 95 Ninety Five 95 Ninety Five 95 Ninety Five
96 Ninety Six 96 Ninety Six 96 Ninety Six 96 Ninety Six
97 Ninety Seven 97 Ninety Seven 97 Ninety Seven 97 Ninety Seven
98 Ninety Eight 98 Ninety Eight 98 Ninety Eight 98 Ninety Eight
99 Ninety Nine 99 Ninety Nine 99 Ninety Nine 99 Ninety Nine
100 One Hundred 100 One Hundred 100 One Hundred 100 One Hundred
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Package Name Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
Package Code Civil Works
Specification No. SRTS-II/C&M/WC-3660/NIT-218(E)/2023
SRTS-II/C&M/WC-3660/NIT-218(E)/2023
1 Fill up only green shaded cells in Sch-3 and Bid Form of price bid
2 All the cells in Sch-5 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for proceed given at the right top of the worksheet and go to Sch-3.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Service Contract) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods and Services) :
● No cell is required to be filled in by the bidder in this worksheet.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid from of price bid :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder 0
Address of Bidder
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
email ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule - 1
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Bidder) : To:
Sr.GM , Contracts & Materials Department,
Name : Power Grid Corporation of India Ltd.,
Address : SRTS-II, RHQ
Singanayakanahalli
Bengaluru-560064
Construction of Storage platform for spares of ±320 kV HVDC Line Materials at Palakkad SS
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Description Material Code HSN Code Whether HSN in column ‘6’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘8’ is confirmed. If not indicate applicable rate of GST * Item Description Unit Qty. Unit Ex-works price (excluding GST) Total Ex-works price (excluding GST) GST
1 7000005840 20 FABRICATION AND SUPPLY 76169990 18% Supply of Galvanised Steel PG Clamps for Sheild / Earth wire of dia 10.98 mm in line with the drawing enclosed Nos 1300 Included 0.00 0 0.00
2 76169990 18% Supply of Galvanised Steel PG clamps suitable to accommodate Earthwire of 10.98 mm in one groove and 12 mm OPGW cable in the other groove, in line with the tentative drawing enclosed. Nos 1300 Included 0.00 0 0.00
3 76169990 18% Supply of 1.5 mm thickness Galvanised steel 'C' / 'U' clamp suitable for 10.98 mm earthwire / shield wire,in line with the drawing enclosed. Nos 23400 Included 0.00 0 0.00
Total Ex-Works Price 0.00 0.00
Total Type Test charges as per Schedule-7 0.00
Total Ex-works Price including Type Test charges 0.00 0.00 Total GST
Note : Specify amount of GST on the transaction between the Contractor and the Employer.
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule - 1 Direct Total 0 Sole Bidder `
BO Total #REF! 0
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address (Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd., , & …….. …….. …….. …….. …….. ……..
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted. Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Item Description Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price Direct 0.00 Direct
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF! #REF! #REF!
Total Ex-works Price including Type Test charges #REF! #REF! #REF!
Discount Sch-1 #REF! MPD Sch-1 #REF!
Dis Alert #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Place : Printed Name :
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule - 2
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(SCHEDULE OF RATES AND PRICES :Transportation, In-transit insurance, loading and unloading.)
Bidder’s Name and Address (Bidder) : To:
Sr.GM , Contracts & Materials Department,
Name : Power Grid Corporation of India Ltd.,
Address : SRTS-II, RHQ
Singanayakanahalli
Bengaluru-560064
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Description Material Code Description Unit Quantity Unit Prices F&I including packing and forwading Including taxes Total Prices
1 7000005840 20 FABRICATION AND SUPPLY 1000015274 Supply of Galvanised Steel PG Clamps for Sheild / Earth wire of dia 10.98 mm in line with the drawing enclosed Nos 1300 Included
2 Supply of Galvanised Steel PG clamps suitable to accommodate Earthwire of 10.98 mm in one groove and 12 mm OPGW cable in the other groove, in line with the tentative drawing enclosed. Nos 1300 Included
3 Supply of 1.5 mm thcikness Galvanised steel 'C' / 'U' clamp suitable for 10.98 mm earthwire / shield wire,in line with the drawing enclosed. Nos 23400 Included
Total F&I Price 0.00
Place : Printed Name :
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule - 3
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
C&M Department Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanjka Multipackage lum-sum #REF!
Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
All Prices are in Indian Rupees.
SI. No. DSR-2021 Ref SAC (Service Accounting Codes) Whether SAC in column '2’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘ 4 ’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Rate in Rs. Total in Rs. GST TAX as confirmed by Bidder Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
I Civil Works Revaluation of J column Tax Calculation
Construction of Hostel Building (GF only) incl. Internal & External Electrification, Internal Roads & RR masonry drains Revaluation of J column Tax Calculation
PART -A-Civil schedule items Revaluation of J column Tax Calculation
1 (1.1.1+1.1.2+1.1.3+1.1.4)/4 995413 18% confirmed By mechanical transport including loading, unloading and stacking with in a lead of 1 km.Lime, moorum, building rubbish, earth, manure or sludge and excavated rocks : ( considering a lead of 1 km ) Cum 2880.00 Included 0.00 0 0
2 2.6.1 995413 18% confirmed Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil cum Cum 2925.00 Included 0.00 0 0
3 2.7.1 995413 18% confirmed Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.Ordinary rock ./DFR Cum 5.00 Included 0.00 0 0
4 2.8.1 995413 18% confirmed Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. Cum 595.00 Included 0.00 0 0
5 2.10.1.1 995413 18% confirmed Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m All kinds of soil .Pipes, cables etc, not exceeding 80 mm dia Metre 100.00 Included 0.00 0 0
6 2.10.1.2 995413 18% confirmed Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m All kinds of soil Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia Metre 50.00 Included 0.00 0 0
7 2.10.1.3 995413 18% confirmed Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m All kinds of soil .Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm Metre 100.00 Included 0.00 0 0
8 2.25A (MOD- ITI CSR LOA rate) 995413 18% confirmed Excavating, supplying and filling of borrowed good earth in the plinth of buildings, sides of buildings and low lying areeas with in the premises as per specification (including royalty) by mechanical transportion upto all leads in identified borrowed areas by Engineer in Charge and also including consolidation by ramming and watering of the earth in layers not exceeding 20 cm in foundations, trenches, plinth, sides of foundation etc. complete. Borrowed earth areas are to be approved by Engineer in charge . Cum 2430.00 Included 0.00 0 0
9 2.25 995413 18% confirmed Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum 1000.00 Included 0.00 0 0
10 2.26.1 995413 18% confirmed Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.All kinds of soil Cum 200.00 Included 0.00 0 0
11 2.26.2 995413 18% confirmed Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.ordinary rock/DFR Cum 10.00 Included 0.00 0 0
12 2.27 995413 18% confirmed Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. Cum 170.00 Included 0.00 0 0
13 2.34.1 995413 18% confirmed Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos / Lindane emulsifiable concentrate of 20% Litres 150.00 Included 0.00 0 0
14 4.2.2 995413 18% confirmed Providing and laying plain cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing :1:1½:3 (1 cement:1½ coarse sand:3 graded stone aggregate 20 mm nominal size) Cum 1.00 Included 0.00 0 0
15 4.1.8 995413 18% confirmed Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Cum 350.00 Included 0.00 0 0
16 4.10. 995413 18% confirmed Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). Sqm 70.00 Included 0.00 0 0
17 4.12 995413 18% confirmed Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification per 50 kg bag of cement 20.00 Included 0.00 0 0
18 4.13 995413 18% confirmed Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. Sqm 70.00 Included 0.00 0 0
19 4.17 995413 18% confirmed Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size,well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. Sqm 70.00 Included 0.00 0 0
20 4.1.4 995413 18% confirmed Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources) (This item shall be operated for kerb stone, screed/bed of drain & top of RR masonry wall) Cum 70.00 Included 0.00 0 0
21 5.1.3 995413 18% confirmed Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (This item shall be operated for grade slab of Hostel building) Cum 45.00 Included 0.00 0 0
22 5.33.1.2 (MOD) 995413 18% confirmed Providing and laying in position ready mixed M-30 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge.(Note :- Cement content considered in this item is @ 340 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately).All works upto plinth level (This item shall operated for buildings, Boundary wall including road works RCC) Cum 295.00 Included 0.00 0 0
23 5.33.2.2(MOD) 995413 18% confirmed Providing and laying in position ready mixed M-30 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge.(Note :- Cement content considered in this item is @ 340 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately).All works above plinth level up to floor V level Cum 140.00 Included 0.00 0 0
24 5.35 995413 18% confirmed Add for using extra cement in the items of design mix over and above the specified cement content therein. Quintal 110.00 Included 0.00 0 0
25 5.9.1 995413 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for foundations Sqm 950.00 Included 0.00 0 0
26 5.9.2 995413 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) - Pardie Walls including attached pilasters, buttresses, plinth & string courses etc. Sqm 100.00 Included 0.00 0 0
27 5.9.3 995413 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for :Suspended floors & Slabs, roofs, landings, balconies and access platform. Sqm 780.00 Included 0.00 0 0
28 5.9.4 995413 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for :Shelves ( Cast-in-situ ) Sqm 50.00 Included 0.00 0 0
29 5.9.5 995413 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers & cantilevers Sqm 750.00 Included 0.00 0 0
30 5.9.6 995413 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for :Columns, pillars, piers abutments posts & struts Sqm 252.00 Included 0.00 0 0
31 5.9.7 995413 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for :Stairs (excluding landings) except spiral staircases. Sqm 25.00 Included 0.00 0 0
32 5.9.13 995413 18% confirmed Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards Sqm 50.00 Included 0.00 0 0
33 5.9.15 995413 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for :Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like Sqm 25.00 Included 0.00 0 0
34 5.9.19 995413 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for :Weather shade, Chajjas, corbels etc., including edges Sqm 30.00 Included 0.00 0 0
35 5.11.1 995413 18% confirmed Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m from floor level for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) Sqm 600.00 Included 0.00 0 0
36 5.22.6+5.22A.6/2 995413 18% confirmed Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level: Thermo-Mechanically Treated bars Fe 500D. Kg 38000.00 Included 0.00 0 0
37 5.30. 995413 18% confirmed Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. Metre 50.00 Included 0.00 0 0
38 6.1.2+ modified 995413 18% confirmed Brick work with non modular fly ash bricks conforming to IS:12894 bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 80.00 Included 0.00 0 0
39 6.34.2 + modified 995413 18% confirmed Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:6 (1 cement : 6 Coarse sand) (230mm width Bricks for Hostel Building wall ) Cum 160.00 Included 0.00 0 0
40 6.12.2+ Modified 995413 18% confirmed Half brick masonry with non modular fly ash bricks conforming to IS:12894, class designation 75 average compressive strength in foundations and plinth in :Cement mortar 1 : 4 ( 1 cement : 4 coarse sand ). Sqm 20.00 Included 0.00 0 0
41 6.13.2+ Modified 995413 18% confirmed Half brick masonry with cnon modular fly ash bricks conforming to IS:12894, class designation 75 average compressive strength in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) Sqm 95.00 Included 0.00 0 0
42 6.15 995413 18% confirmed Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. Sqm 95.00 Included 0.00 0 0
43 7.1.1 995413 18% confirmed Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 320.00 Included 0.00 0 0
44 (8.2.2.1+8.2.2.2) /2 (MOD) 995413 18% confirmed Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade of any area Sqm 20.00 Included 0.00 0 0
45 8.3.2 995413 18% confirmed Extra for providing edge moulding to 18 mm thick granite stone counters, vanities etc.including machine polishing to edge to give high gloss finish etc. complete. Metre 60.00 Included 0.00 0 0
46 9.21.1 995413 18% confirmed Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Sqm 35.00 Included 0.00 0 0
47 9.23 995413 18% confirmed Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). Sqm 35.00 Included 0.00 0 0
48 9.48.2 995413 18% confirmed Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings/wooden frames with rawl plugs screws etc. Kg 900.00 Included 0.00 0 0
49 9.90.2 995413 18% confirmed Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Size 50 mm Each 6.00 Included 0.00 0 0
50 9.92.2 995413 18% confirmed Providing and fixing chromium plated brass handles with necessary screws etc. complete.100 mm Each 25.00 Included 0.00 0 0
51 9.96.1 995413 18% confirmed Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete300x16 mm Each 26.00 Included 0.00 0 0
52 9.97.2 995413 18% confirmed Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm Each 16.00 Included 0.00 0 0
53 9.97.4 995413 18% confirmed Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :150x10 mm Each 16.00 Included 0.00 0 0
54 9.100.1 995413 18% confirmed Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm Each 24.00 Included 0.00 0 0
55 9.101.2 995413 18% confirmed Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper Each 26.00 Included 0.00 0 0
56 9.103 995413 18% confirmed Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. Each 13.00 Included 0.00 0 0
57 9.114.1 995413 18% confirmed Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. completeTriple strip vertical type Each 12.00 Included 0.00 0 0
58 9.117.1 995413 18% confirmed Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws,joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin-charge. Extruded section profile size 48x40 mm Metre 40.00 Included 0.00 0 0
59 9.118.1 995413 18% confirmed Providing and fixing to existing door frames. 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats.The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge including all fittings(For W.C. and bathroom door shutter). Sqm 15.00 Included 0.00 0 0
60 9.129 995413 18% confirmed Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS:12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge Sqm 30.00 Included 0.00 0 0
61 10.14.1.1 995413 18% confirmed Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb ( Work shops) Metre 75.00 Included 0.00 0 0
62 10.18 995413 18% confirmed Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing Each 8.00 Included 0.00 0 0
63 10.25.2 (MOD) 995413 18% confirmed Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in treads, landings, of stair cases, including In gratings, frames, guard bar, ladder, railings, brackets, gates, hand rails with MS tube and similar works incl. Boundary wall Y-angle for Barberbed wire fencing kg 100.00 Included 0.00 0 0
64 11.23.5 995413 18% confirmed Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur green marble for stair case steps ( Tread and risers), landings. Sqm 25.00 Included 0.00 0 0
65 11.24 995413 18% confirmed Extra for pre finished nosing to treads of steps of marble stone over above item Metre 30.00 Included 0.00 0 0
66 11.25 995413 18% confirmed Extra for marble stone flooring in treads of steps and risers using single length upto 2.0m.over the above item of marble fooring including roughening/removing of top Tread portion of steps of 01 mm layer for a width of 75 mm on tread edge of steps.Grooving/Cutting three parallel equidistant lines having width of 4 mm on tread edge of marble steps. The rate quoted shall include all the operations mentioned above. Sqm 25.00 Included 0.00 0 0
67 11.37 995413 18% confirmed Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. Sqm 45.00 Included 0.00 0 0
68 8.31 995413 18% confirmed Providing and fixing Ist quality ceramic glazed wall tiles of conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete Sqm 65.00 Included 0.00 0 0
69 11.41.2 (MOD) 995413 18% confirmed Providing and laying vitrified floor tiles (Glossy finish)in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of 600mm x600mm Sqm 390.00 Included 0.00 0 0
70 11.46.2 995413 18% confirmed Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm Sqm 205.00 Included 0.00 0 0
71 11.41.2 (MOD) 995413 18% confirmed Providing and laying vitrified antiskid tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of 600mm x600mm Sqm 75.00 Included 0.00 0 0
72 12.21.1 995413 18% confirmed Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase Metre 225.00 Included 0.00 0 0
73 12.22 995413 18% confirmed Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. Each 6.00 Included 0.00 0 0
74 12.41.2 995413 18% confirmed Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,Single socketed pipe 110 mm diameter Metre 24.00 Included 0.00 0 0
75 12.42.6.2 995413 18% confirmed Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Plain Shoe 110 mm Shoe Each 12.00 Included 0.00 0 0
76 12.43.2 995413 18% confirmed Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm Each 18.00 Included 0.00 0 0
77 12.44 995413 18% confirmed Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Each 6.00 Included 0.00 0 0
78 13.1.2 995413 18% confirmed 12mm thick cement plaster of mix 1:6 (1 cement : 6 fine sand). Sqm 905.00 Included 0.00 0 0
79 13.2.2 995413 18% confirmed 15 mm cement plaster on rough side of single or half brick masonry wall or laterite stone masonry wall of mix 1:6 (1 cement : 6 fine sand) Sqm 350.00 Included 0.00 0 0
80 13.7.1 995413 18% confirmed Providing plastering 12mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. Sqm 690.00 Included 0.00 0 0
81 13.16.1 995413 18% confirmed 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) Sqm 450.00 Included 0.00 0 0
82 13.11 995413 18% confirmed 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). Sqm 720.00 Included 0.00 0 0
83 13.24.2 995413 18% confirmed Extra for plastering done on moulding, cornices or architraves including neat finish to line and level :im Two coats Sqm 150.00 Included 0.00 0 0
84 13.29.3 995413 18% confirmed 18 mm thick plain cement mortar band in cement mortar 1:4 (1cement : 4 fine sand): Raised Band cm per metre 2000.00 Included 0.00 0 0
85 13.42.1 995413 18% confirmed Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work Sqm 1705.00 Included 0.00 0 0
86 13.43.1 995413 18% confirmed Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer Sqm 1705.00 Included 0.00 0 0
87 13.45.1 995413 18% confirmed Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm Sqm 720.00 Included 0.00 0 0
88 13.62.1 995413 18% confirmed Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacturer. Sqm 5.00 Included 0.00 0 0
89 13.80 995413 18% confirmed Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Sqm 1705.00 Included 0.00 0 0
90 21.1.1.2 995413 18% confirmed Providing and fixing sliding aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. : For Fixed portion.. Powder coated aluminium (minimum thickness of powder coating 50 micron) Kgs 235.00 Included 0.00 0 0
91 21.1.2.2 995413 18% confirmed Providing and fixing Sliding aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, to be paid for separately) For Aluminium shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required including all fittings like handles, telescopic stays. Powder coated aluminium (minimum thickness of powder coating 50 micron) Kgs 65.00 Included 0.00 0 0
92 21.3.2 995413 18% confirmed Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):one side facial area only be measured for payment.Fully glazed windows with openable shutters outside and wire mesh shutters openable inside. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) Sqm 56.00 Included 0.00 0 0
93 21.8 995413 18% confirmed Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width metre 190.00 Included 0.00 0 0
94 22.5 995413 18% confirmed Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. Sqm. 20.00 Included 0.00 0 0
95 22.7 995413 18% confirmed Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. Sqm 660.00 Included 0.00 0 0
96 17.1.1 995413 18% confirmed Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. Each 2.00 Included 0.00 0 0
97 17.3.1 995413 18% confirmed Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid Each 2.00 Included 0.00 0 0
98 17.7.3 995413 18% confirmed Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a 15 mm C.P. brass pillar taps Each 9.00 Included 0.00 0 0
99 17.10.1.1 995413 18% confirmed Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board. 510x1040 mm bowl depth 250 mm Each 2.00 Included 0.00 0 0
100 17.5.1 995413 18% confirmed Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with CP push cock type flushing arrangement, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: Single half stall urinal with CP push cock type flushing cistern Each 4.00 Included 0.00 0 0
101 17.22 995413 18% confirmed Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. each 2.00 Included 0.00 0 0
102 17.28.1.1 995413 18% confirmed Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete . Semi rigid 32mm dia Each 11.00 Included 0.00 0 0
103 17.28.1.2 995413 18% confirmed Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete Flexible pipe 40mm dia Each 1.00 Included 0.00 0 0
104 17.31 995413 18% confirmed Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each 9.00 Included 0.00 0 0
105 17.33 995413 18% confirmed Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. Each 9.00 Included 0.00 0 0
106 18.8.2 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings like bends ,tees, unions etc. with onestep CPVC solvent cement and the cost of cutting chases and makinggood the same of Engineer in Charge.including testing of joints complete as per direction. Concealed work, including cutting chases and making good thewalls etc.20 mm nominal outer dia Pipes Metre 120.00 Included 0.00 0 0
107 18.8.3 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings like bends ,tees, unions etc. with onestep CPVC solvent cement and the cost of cutting chases and makinggood the same of Engineer in Charge.including testing of joints complete as per direction. Concealed work, including cutting chases and making good thewalls etc.25 mm nominal outer dia Pipes Metre 220.00 Included 0.00 0 0
108 18.8.4 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings like bends ,tees, unions etc. with onestep CPVC solvent cement and the cost of cutting chases and makinggood the same of Engineer in Charge.including testing of joints complete as per direction. Concealed work, including cutting chases and making good thewalls etc.32 mm nominal outer dia Pipes Metre 85.00 Included 0.00 0 0
109 18.7.5 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal outer dia Pipes Metre 45.00 Included 0.00 0 0
110 18.7.6 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal outer dia Pipes Metre 45.00 Included 0.00 0 0
111 18.9.2 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work in trenches as well as exposed on wall with clamps .20 mm nominal outer dia Pipes Metre 10.00 Included 0.00 0 0
112 18.9.3 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work in trenches as well as exposed on wall with clamps .25 mm nominal outer dia Pipes Metre 15.00 Included 0.00 0 0
113 18.9.4 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work in trenches as well as exposed on wall with clamps. 32 mm nominal outer dia Pipes Metre 50.00 Included 0.00 0 0
114 18.9.5 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work in trenches as well as exposed on wall with clamps 40 mm nominal outer dia Pipes Metre 50.00 Included 0.00 0 0
115 18.9.6 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work in trenches as well as exposed on wall with clamps. 50 mm nominal outer dia Pipes Metre 50.00 Included 0.00 0 0
116 18.9.7 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work in trenches as well as exposed on wall with clamps.62.50 mm nominal inner dia Pipes Metre 10.00 Included 0.00 0 0
117 18.9.9 995413 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work in trenches as well as exposed on wall with clamps. 100 mm nominal inner dia Pipes Metre 10.00 Included 0.00 0 0
118 18.21.2.1 995413 18% confirmed Providing and fixing unplasticised PVC connection pipe with brass unions 45cm long and 15cm nominal bore Each 17.00 Included 0.00 0 0
119 18.51.1 995413 18% confirmed Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore. Each 4.00 Included 0.00 0 0
120 18.53.1 995413 18% confirmed Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15mm nominal bore. Each 11.00 Included 0.00 0 0
121 18.22.1 995413 18% confirmed Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100mm diameter Each 4.00 Included 0.00 0 0
122 18.48 995413 18% confirmed Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Per litre 4000.00 Included 0.00 0 0
123 18.62.4 995413 18% confirmed Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball.40 mm nominal bore, 206mm long, weighing not less than 690 gms Each 1.00 Included 0.00 0 0
124 18.32.1 995413 18% confirmed Constructing masonry chamber 30 x 30 x 50 cm inside with 7.5 class designation fly ash brick work in cm 1 : 5 ( 1 cement : 5 fine sand ) for stop cock with CI surface box 100 x 100x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2 :4 ( 1cement : 2 coarse sand:4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10(1 cement:5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement 1:3(1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design:With fly ash .(non modular) bricks of class designation 7.5 For gate valves Each 4.00 Included 0.00 0 0
125 18.17.1A 995413 18% confirmed Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore Each 3.00 Included 0.00 0 0
126 18.17.1 995413 18% confirmed Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore Each 3.00 Included 0.00 0 0
127 18.17.2 995413 18% confirmed Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore Each 4.00 Included 0.00 0 0
128 18.17.3 995413 18% confirmed Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore Each 1.00 Included 0.00 0 0
129 18.17.4 995413 18% confirmed Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore Each 1.00 Included 0.00 0 0
130 19.4.3.1 995413 18% confirmed Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :180 x 150 mm size P type with FPS bricks.With fly ash (non modular) bricks of class designation 7.5 Each 3.00 Included 0.00 0 0
131 19.7.1.1 995413 18% confirmed Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1 1/2:3 mix (1 cement :1 1/2 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) Inside size 90x80 cm and 45 cm deep With fly ash (non modular) bricks of class designation 7.5 Each 2.00 Included 0.00 0 0
132 19.7.2.1 995413 18% confirmed Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 1 1/2 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) With fly ash . (non modular) bricks of class designation 7.5 Each 1.00 Included 0.00 0 0
133 19.8.1.1 995413 18% confirmed Extra for depth for manholes :Size 90x80 cm With fly ash (non modular) bricks of class designation 7.5 Metre 5.00 Included 0.00 0 0
134 19.8.2.1 995413 18% confirmed Extra for depth for manholes :Size 120x90 cm With fly ash . (non modular) bricks of class designation 7.5 Metre 5.00 Included 0.00 0 0
135 19.18.1 995413 18% confirmed Supplying and fixing C.I. cover without frame455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg Each 2.00 Included 0.00 0 0
136 19.18.2 995413 18% confirmed Supplying and fixing C.I. cover without frame for manholes :500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg Each 1.00 Included 0.00 0 0
137 16.3.10 + 2.25 995413 18% confirmed Supplying and filling of Murram in foundations including laying in layers of 20cm and consolidating each layer as per the instructions of Engineer in charge stacking at site. Cum 1040.00 Included 0.00 0 0
138 16.1 (MOD) 995413 18% confirmed Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 30 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 100 metres. sqm 1500.00 Included 0.00 0 0
139 16.68 995413 18% confirmed Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge Sqm 1245.00 Included 0.00 0 0
140 16.69 995413 18% confirmed Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature,jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by Engineer-in-charge). Cum 42.00 Included 0.00 0 0
141 16.3.1 995413 18% confirmed Supplying and stacking at site.90 mm to 45 mm size stone aggregate Cum 200.00 Included 0.00 0 0
142 16.3.6 995413 18% confirmed Supplying and stacking at site.Stone screening 13.2 mm nominal size (Type A) Cum 50.00 Included 0.00 0 0
143 16.3.10 995413 18% confirmed Supply and stacking of Murram at site Cum 15.00 Included 0.00 0 0
144 16.4 995413 18% confirmed Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . Cum 720.00 Included 0.00 0 0
145 16.79 995413 18% confirmed Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. Cum 720.00 Included 0.00 0 0
146 13.33.1 995413 18% confirmed Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :Flush/ Ruled pointing Sqm 480.00 Included 0.00 0 0
147 19.6.1 995413 18% confirmed Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :100 mm dia. R.C.C. pipe Meter 50.00 Included 0.00 0 0
148 19.6.2 995413 18% confirmed Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe Meter 50.00 Included 0.00 0 0
149 19.6.3 995413 18% confirmed Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe Meter 50.00 Included 0.00 0 0
150 19.6.4 995413 18% confirmed Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :300 mm dia. R.C.C. pipe Meter 50.00 Included 0.00 0 0
151 19.35.1 995413 18% confirmed Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes. meter 6.00 Included 0.00 0 0
152 19.35.2 995413 18% confirmed Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.600 mm dia RCC pipes. meter 20.00 Included 0.00 0 0
153 16.45 995413 18% confirmed Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.).25mm wide and 40mm deep per cm depth per cm width per metre length 1240.00 Included 0.00 0 0
154 16.46.1 995413 18% confirmed Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints all complete as per direction of the Engineer-in-Charge. Using grade 'A' sealing compound conforming to IS: 1834.(25mm wide and 40mm deep) per cm depth per cm width per metre length 1240.00 Included 0.00 0 0
155 19.32.1 (MOD) 995413 18% confirmed Making Percolation pit 2.5 m diameter 5.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay broken bricks and pebbles..class designation 7.5 (This item shall be operated along the boundary as approved by Engineer in-charge - as per CMDA norms) each 3.00 Included 0.00 0 0
PART B-Civil Non schedule items Revaluation of J column Tax Calculation
1 NS-1 995413 18% confirmed Diluting and injecting chemical emulsion (excluding of the cost of the chemical emulsion) for PRE-CONSTRUCTIONAL ANTI-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (Plinth area of the building at ground floor only shall be measured for payment). (Only application charges shall be paid under this item)Chlorpyriphos / Lindane Emulsifiable concentrate 20% with 1% concentration. Sqm 660.00 Included 0.00 0 0
2 NS-2 995413 18% confirmed Providing & fixing mesh Arpita or equivalent made out of galvanized iron of nominal thickness 0.35 mm with a zinc coating of 120 gms per sqm along the junctions of masonry and concrete works including fixing,scaffolding,lead & lifts etc.(This item shall be operated in Col-wall,Beam-wall and closing of electrical conduit junctions) Sqm 65.00 Included 0.00 0 0
3 NS-3 995413 18% confirmed Providing and fixing PVC shock absorbers for rear side of doors Each 13.00 Included 0.00 0 0
4 NS-4 995413 18% confirmed Providing and placing with lime concrete Brick bat coba or cinder filling to the sunk floors in toilets well compacted carefully by hand beating to required slopes including consolidation, curing, mix shall be one part lime mortar 2 1bar 2 parts brick bat coba and finishing the same with the cement mortar 1 : 4, 1 cement : 4 coarse sand by adding water proof compound as per manufactures specifications : For toilet sunken portions. Cum 6.00 Included 0.00 0 0
5 NS-5 995413 18% confirmed Providing and fixing CP brass over head arm of length minimum 30cm for fixing shower through 15mm GI pipe with wall flange. Nos 5.00 Included 0.00 0 0
6 NS-6 995413 18% confirmed Providing and fixing CP flange washers for CP bib cocks and angle cocks Nos 15.00 Included 0.00 0 0
7 NS-7 995413 18% confirmed Providing and fixing stainless steel gratings with or with out hole for waste pipe for floor/nahni traps 100mm dia. Nos 15.00 Included 0.00 0 0
8 NS-8 995413 18% confirmed Supplying and fixing of approved make CP towel rail 600mm long including CP screws etc. complete. Jaquar make Nos 9.00 Included 0.00 0 0
9 NS-9 995413 18% confirmed Supplying,installing,testing and commissioning approved make 15 mm CP health faucet with CP flexible tube 1.0 m long,CP crutch,nozzle and 2- way Bib Cock with wall flange etc. complete. Jaquar Model No. 573 and 041 or equivalent. Nos 5.00 Included 0.00 0 0
10 NS-10 995413 18% confirmed Providing and fixing composite wall mixer with two inlets ( for cold and hot water ) one tap outlet and common shower out let with cp brass arm of required length for connection. Wall flanges lever controlled operation complete.( model No 2015 of Nova spectrum or equivalent model in Seiko etc.) Nos 4.00 Included 0.00 0 0
11 NS-11 995413 18% confirmed Supplying, laying,jointing ,testing and commisioning approved make upvc pipes SWR grade B conforming to IS 13592.The quoted rates shall include necessary fittings like Tees, bends, offsets etc. including MS angle with GI clamps complete: 110mm dia Metre 50.00 Included 0.00 0 0
12 NS-12 995413 18% confirmed Supplying, laying,jointing ,testing and commisioning approved make upvc pipes SWR grade B conforming to IS 13592.The quoted rates shall include necessary fittings like Tees, bends, offsets etc. including MS angle with GI clamps complete: 75mm dia Metre 50.00 Included 0.00 0 0
13 NS-13 995413 18% confirmed Supply, Laying, jointing and commisioning approved make PVC -U pipe of grade SN4 confirming to IS 15328.The quoted rate shall include necessary fittings like Tees Bends, Offsets etc, complete.200 mm diameter Metre 10.00 Included 0.00 0 0
14 NS-14 995413 18% confirmed Supply, Laying, jointing and commisioning approved make PVC -U pipe of grade SN4 confirming to IS 15328.The quoted rate shall include necessary fittings like Tees Bends, Offsets etc, complete.160 mm diameter Metre 10.00 Included 0.00 0 0
15 NS-15 995413 18% confirmed Supplying, laying,jointing ,testing and commisioning approved make upvc pipes SWR grade B conforming to IS 13592.The quoted rates shall include necessary fittings like Tees, bends, offsets etc. including MS angle with GI clamps complete: 40mm dia Metre 20.00 Included 0.00 0 0
16 NS-16 995413 18% confirmed Supplying, laying,jointing ,testing and commisioning approved make upvc pipes SWR grade B conforming to IS 13592.The quoted rates shall include necessary fittings like Tees, bends, offsets etc. including MS angle with GI clamps complete: 50mm dia Metre 10.00 Included 0.00 0 0
17 NS-17 995413 18% confirmed Supply, fixing and testing of cast iron lever operated slim seal type Butterfly valves of CI body and spheroidal graphite iron disc (SG iron),with nitrile rubber seal, tested to 20 kg / sq.cm Confrming to BS 5155 / MF6 standards and including a set of GI flanges as per BS-10 table 1 including bolt nuts, and Neoprene rubber gaskets etc.50 mm dia Nos 4.00 Included 0.00 0 0
18 NS-18 995413 18% confirmed Supply, fixing and testing of brass Automatic Air release valve approved quality for booster line Vertical riser a) 20 mm dia Nos 1.00 Included 0.00 0 0
19 NS-19 995413 18% confirmed Supply and fixing of side wall grab bar of approved make Nos 1.00 Included 0.00 0 0
20 NS-20 995413 18% confirmed Supply and fixing of PVC floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) with brass CP frame & cover (150 mm x 150 mm). Trap of 100 mm dia inlet and 75 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) Nos 16.00 Included 0.00 0 0
21 NS-21 995413 18% confirmed Supply and fixing of PVC P-trap 110 dia with necessory of 50 dia multitrap connection (heavy duty) with brass CP frame & cover (150 mm x 150 mm). Trap of 100 mm dia inlet and 100 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) Nos 4.00 Included 0.00 0 0
22 NS-22 995413 18% confirmed Supply and fixing of CP Floor cleanout (150mmx150mm). For removing Clogging, etc., complete Nos 8.00 Included 0.00 0 0
23 NS-23 995413 18% confirmed Supply and fixing of 125 micron thick plastic sheet including cutting fixing etc., complete ( for road work). Sqm 1800.00 Included 0.00 0 0
Internal Electrification Revaluation of J column Tax Calculation
1.0 LT PANELS (COMMON SPECIFICATION) Revaluation of J column Tax Calculation
HOSTEL BLOCK PANEL Revaluation of J column Tax Calculation
1.1 NS 995413 18% confirmed Supply and installation of type Main Distribution Board for each Band Blocks: Supply, installation and commissioning pre-wired, factory fabricated, distribution board of steel sheet 14SWG (Main frame) & 16SWG (remaining) thick CRCA sheets(thickness not less than 1.6mm) for 415V AC system, IP-52 protected duly powder coated paint, with tinned copper bus bars of suitable size, incoming, out going and internal cable/wires termination including Glanding, Energy meters, connecting with earth pit with 2 runs of copper wire/strip (excl supply copper wire/Strip) supply, installation and terminaof MCCB, MCBs of Type-C, 25kA Short circuit rating) , in complete shape along with any other required accessories, with following configuration: i.200A FPMCCB - 1No ii.Busbars for 3-Phases, Neutral and Earthing iii.63A, FP MCBs -6No. vi. 16A-SP MCBs-4No. v. Direct Connected (with out CT) 3-Phase, 4-Wire -6No. Static Energy meters (LCD display) of class 1.0 or better accuracy, with kWh, kVAh,kVARh, MD with Min current rating starting from 0A and Max. current rating should not be less than 60A. v. Red, Yellow, Blue LED indicating lamps for each phase of incomer vi)Mounting Arrangement: Suitable stand shall be provided for Wall mounting with stang extended upto ground level. Incomer: 100 TP+NL 25kA MCCB Outgoing:63A TP+NL MCCB - 4 Nos Bus: Aluminum rated for 150A. Bus size shall be rated based on 0.7A/sq.mm. Bus thickness shall not be more than 8mm. Neutral bus size shall be same the phase size. Set 1.00 Included 0.00 0 0
2.0 DISTRIBUTION BOARDS Revaluation of J column Tax Calculation
2.1 NS 995413 18% confirmed Supply and installation of type Main Distribution Board for D Type Quarter: Supply, installation and commissioning pre-wired, factory fabricated, distribution board of steel sheet (thickness not less than 1.6mm) for 415V AC system, IP 52 protected duly powder coated paint, with tinned copper bus bars of suitable size, incoming, out going and internal cable/wires termination including Glanding, Energy meters, connecting with earth pit with 2 runs of copper wire/strip (excl supply copper wire/Strip supply, installation and termination of MCCB, MCBs of Type-C, 10kA Short circuit rating) , with following configuration: i. 100A, 16kA, FPMCCB - 1No iii. 63A, FP MCBs -2No. & 32A DP MCB-2No. iv. 16A 4P MCBs -2No. v. Direct Connected (with out CT) 3-Phase, 4-Wire -2No Static Energy meters (LCD display) of class 1.0 or better accuracy, with kWh, kVAh,kVARh, MD with Min current rating starting from 0A and Max. current rating should not be less than 60A v. Red, Yellow, Blue LED indicating lamps for each phase. vi)Mounting Arrangement: Wall Mounting with support frame extended upto ground level. vii) Provision for incoming cables of 3.5x70sq.mm armoured acbles and for conduit for flats :8Way LPDB I / C - 63A TP+NL MCB - 1 No O / G - 63A DP RCCB 30mA - 3 Nos i.63A Four Pole(3Phase and Neutral) RCCB, 30mA - 2No ii.Busbars for 3-Phases, Neutral and Earthing iii, 32A- SPMCBs-10 iv.16A, SPMCBs --5 v. 6A SP MCB-10 Nos Including all interconnections & accessories etc as reqd.-class 3 energy limiting of IEC 60898. Set 5.00 Included 0.00 0 0
2.2 NS 995413 18% confirmed 40A TP+NL MCB in weather proof enclosure including all accessaries. Vendor need to ensure the cable termination should be have enough space. Rate shall be same for concealing in wall or surface fixing as required as per site conditions. Set 1.00 Included 0.00 0 0
3.0 Cables Revaluation of J column Tax Calculation
3.1 NS 995413 18% confirmed Supply, Erection, Testing and commissioning of LT XLPE insulated 1.1 kV Armored conductor cables of following sizes. trays, trenches, ducts and as per the site conditions. Grade- 3.5C x 70 sq.mm Al. Ar LT XLPE cable Mtr 50.00 Included 0.00 0 0
3.2 NS 995413 18% confirmed Supply, Erection, Testing and commissioning of LT XLPE insulated 1.1 kV Armored conductor cables of following sizes. trays, trenches, ducts and as per the site conditions. Grade- 4C x 10 sq.mm Al. Ar. LT XLPE cable Mtr 60.00 Included 0.00 0 0
4.0 Terminations Revaluation of J column Tax Calculation
4.1 NS 995413 18% confirmed Supply & terminating the ends of cables of following sizes using Siemens type sigle compression cable glands, crimping type Aluminum/Copper lugs of required size, crimping paste, tapes, bolt nuts, double washers, spring washers, gland earthing clips complete. Each cable shall be identified with cable tags above the panel / DB. Cable shall be properly dressed before termination and bent at an angle of 15 times the radius of the cable. No extra holes shall be made on top of panel and if any made shall be sealed properly. The final tightness at every terminal shall be done with a torque wrench and tightened up to the recommended level. Flexible wires shall be glanded with cast aluminum glands and earthed and connected properly. Size- 3.5C x 70 sq.mm Al. Ar LT XLPE cable Nos 4.00 Included 0.00 0 0
4.2 NS 995413 18% confirmed Supply & terminating the ends of cables of following sizes using Siemens type sigle compression cable glands, crimping type Aluminum/Copper lugs of required size, crimping paste, tapes, bolt nuts, double washers, spring washers, gland earthing clips complete. Each cable shall be identified with cable tags above the panel / DB. Cable shall be properly dressed before termination and bent at an angle of 15 times the radius of the cable. No extra holes shall be made on top of panel and if any made shall be sealed properly. The final tightness at every terminal shall be done with a torque wrench and tightened up to the recommended level. Flexible wires shall be glanded with cast aluminum glands and earthed and connected properly. Size- 4C x 10 sq.mm Al. Ar. LT XLPE cable Nos 4.00 Included 0.00 0 0
5.0 SUB MAINS Revaluation of J column Tax Calculation
5.1a NS 995413 18% confirmed Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required Supply, Laying, Testing and Commissioning of 2 runs of 4sqmm + 1 run of 2.5sqmm(E) PVC insulatedFRLS multistrand copper wire in FRLS PVC conduits of 25mm dia with all accessories as required at site for 16/6A sockets and 25A metal clad sockets. Size- 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Mtr 150.00 Included 0.00 0 0
5.1b NS 995413 18% confirmed Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required Supply, Laying, Testing and Commissioning of 2 runs of 4sqmm + 1 run of 2.5sqmm(E) PVC insulatedFRLS multistrand copper wire in FRLS PVC conduits of 25mm dia with all accessories as required at site for 16/6A sockets and 25A metal clad sockets. Size- 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Mtr 150.00 Included 0.00 0 0
5.2 NS 995413 18% confirmed Supply, Laying, Testing and Commissioning of 3 runs of 2.5sqmm PVC insulatedFRLS multistrand copper wire in FRLS PVC conduits of 25mm dia with all accessories as required at site for 6A sockets. Maximum of 2 sockets may be looped to a single circuit. Rate shall include chipping and chasing of walls wherever required at site. Chicken mesh shall be used for finishing the wall chasing.PVC conduit shall be as per IS 9537(P-III) (heavy duty for ceiling& floor medium duty for wall).--2.5 SQ MM, 25 MM pvc Mtr 550.00 Included 0.00 0 0
5.3 NS 995413 18% confirmed Supply, Laying, Testing and Commissioning of 3 runs of 1.5sqmm PVC insulatedFRLS multistrand copper wire in FRLS PVC conduits of 25mm dia with all accessories as required at site for 6A sockets. Maximum of 4 sockets may be looped to a single circuit. Rate shall include chipping and chasing of walls wherever required at site. Chicken mesh shall be used for finishing the wall chasing.PVC conduit shall be as per IS 9537(P-III) (heavy duty for ceiling& floor medium duty for wall). Mtr 170.00 Included 0.00 0 0
5.4 NS 995413 18% confirmed Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. - 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. Mtr 50.00 Included 0.00 0 0
5.5 NS 995413 18% confirmed Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. - 4 X 16 sq. mm + 2 X 6 sq. mm earth wire. Mtr 25.00 Included 0.00 0 0
5.6 NS 995413 18% confirmed Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) Each 1.00 Included 0.00 0 0
6.0 POINT WIRING Revaluation of J column Tax Calculation
6.1a NS 995413 18% confirmed Supply, Erection, Testing and commissioning of 3R 1.5sqmm PVC insulatedFRLS copper wire in FRLS PVC conduit (heavy duty for ceiling & floor medium duty for wall) along with Modular 6A one way switch with molded front plate GI anodized enclosure and other associated accessories as required as per the site conditions. PRIMARY POINT Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. LIGHT POINT(switch board to first fittings) Pts 30.00 Included 0.00 0 0
6.1b NS 995413 18% confirmed Supply, Erection, Testing and commissioning of 3R 1.5sqmm PVC insulatedFRLS copper wire in FRLS PVC conduit (heavy duty for ceiling & floor medium duty for wall) along with Modular 6A one way switch with molded front plate GI anodized enclosure and other associated accessories as required as per the site conditions. PRIMARY POINT Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. FAN POINT With two way switch control and regulator. Pts 42.00 Included 0.00 0 0
6.1c NS 995413 18% confirmed Supply, Erection, Testing and commissioning of 3R 1.5sqmm PVC insulatedFRLS copper wire in FRLS PVC conduit (heavy duty for ceiling & floor medium duty for wall) along with Modular 6A one way switch with molded front plate GI anodized enclosure and other associated accessories as required as per the site conditions. PRIMARY POINT Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. LIGHT POINT With two way control. Pts 10.00 Included 0.00 0 0
6.1d NS 995413 18% confirmed Supply, Erection, Testing and commissioning of 3R 1.5sqmm PVC insulatedFRLS copper wire in FRLS PVC conduit (heavy duty for ceiling & floor medium duty for wall) along with Modular 6A one way switch with molded front plate GI anodized enclosure and other associated accessories as required as per the site conditions. PRIMARY POINT Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Exhaust Fan POINT(from SB to socket). Pts 3.00 Included 0.00 0 0
6.2a NS 995413 18% confirmed SECONDARY POINT ( Looped from first point to next light fittings.) Pts 55.00 Included 0.00 0 0
6.2b NS 995413 18% confirmed 6A socket controlled by 6A switch to be fixed in the lighting switch board. Pts 10.00 Included 0.00 0 0
6.3a NS 995413 18% confirmed Supply, Laying, Testing and Commissioning of 3 runs of 1.5sqmm PVC insulatedFRLS multistrand copper wire in FRLS PVC conduits of 25mm dia with all accessories as required at site for Circuit mains from DB to switch board and looping from SB to SB.Rate shall include chipping and chasing of walls wherever required at site. Chicken mesh shall be used for finishing the wall chasing.PVC conduit shall be as per IS 9537(P-III) (heavy duty for ceiling& floor medium duty for wall).Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.- 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. Mtr 500.00 Included 0.00 0 0
6.4a NS 995413 18% confirmed Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required- 1 or 2 Module. Each 10.00 Included 0.00 0 0
6.4b NS 995413 18% confirmed Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required- 3 Module. Each 10.00 Included 0.00 0 0
6.4c NS 995413 18% confirmed Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required- 4 Module. Each 10.00 Included 0.00 0 0
6.4d NS 995413 18% confirmed Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required- 6 Module (200mmX75mm) Each 10.00 Included 0.00 0 0
6.5 NS 995413 18% confirmed Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. Each 10.00 Included 0.00 0 0
6.6 NS 995413 18% confirmed Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Each 10.00 Included 0.00 0 0
6.7 NS 995413 18% confirmed Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.- Double Pole. Each 20.00 Included 0.00 0 0
6.8 NS 995413 18% confirmed Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. Each 20.00 Included 0.00 0 0
6.9a NS 995413 18% confirmed Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm X 150 mm X 60 mm deep Each 10.00 Included 0.00 0 0
6.9b NS 995413 18% confirmed Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 150 mm X 150 mm X 60 mm deep Each 10.00 Included 0.00 0 0
7.0 SOCKETS Revaluation of J column Tax Calculation
7.1 NS 995413 18% confirmed Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc.incl flat/round pin as required. For Exhaust fan Nos 40.00 Included 0.00 0 0
7.2 NS 995413 18% confirmed Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required Nos 40.00 Included 0.00 0 0
7.3 NS 995413 18% confirmed Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. Nos 20.00 Included 0.00 0 0
7.4 NS 995413 18% confirmed Supply, Installation, testing and commissioning of 1 No 16/6A universal sockets suitable controlled by 1 no 16A switch(indicator) in a single modular plate and fixing the same for a single location with a dummy if necessary and other associated accessories including suitable back box as required as per the site conditions. For utility purpose. Nos 10.00 Included 0.00 0 0
7.5 NS 995413 18% confirmed Supply, Installation, testing and commissioning of 1 No of 20A modular switch with DP MCB. For indoor A/c units & Lab sockets. Nos 2.00 Included 0.00 0 0
7.6a NS 995413 18% confirmed Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) Nos 10.00 Included 0.00 0 0
7.6b NS 995413 18% confirmed Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm) Nos 10.00 Included 0.00 0 0
8.0 EARTHING Revaluation of J column Tax Calculation
Common Note: All earthing cables/wires pvc outer sheath should be having of green colour only. Below 25 Sq.mm cable shall be FRLS and above 25 Sq.mm cable shall be FR. All single core flexible cables for earthing shall be laid in FRLS PVC conduit only. Rates shall be inclusive of terminations using suitable lugs, PVC glands, PVC conduits etc. Rates shall be same for all types of laying. Earth flats shall be laid on trays before laying the cables, inspected for quality of joints and reported. Copper or aluminium earth flats shall be overlapped by double the length of it's width at the welded joints. Rate shall be inclusive for welding, slag removing, painting with aluminium paint and connecting at the panel end using suitable bolt & nuts, washers etc. Rate shall be same for laying in trenches, clamping on wall and laying on trays. When laid on trays, all earth flats shall be bolted with tray at 3mtrs interval using suitable boltnut & washers. Copper flats shall be exothermically welded at the joints. Revaluation of J column Tax Calculation
8.1 NS 995413 18% confirmed Supply, laying of 6 sqmm multi stranded FRLS copper wire in suitable PVC conduit with all accessories as required. mts 20.00 Included 0.00 0 0
8.2 NS 995413 18% confirmed Supply, laying of 8 SWG bare copper wire mts 150.00 Included 0.00 0 0
8.3 NS 995413 18% confirmed Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. NOS 50.00 Included 0.00 0 0
8.4 NS 995413 18% confirmed Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 2.00 Included 0.00 0 0
8.5 NS 995413 18% confirmed Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) in surface or in recess for connections etc. as required. Mtr. 50.00 Included 0.00 0 0
8.6 NS 995413 18% confirmed Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Mtr. 20.00 Included 0.00 0 0
8.7 NS 995413 18% confirmed Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. Mtr. 20.00 Included 0.00 0 0
8.8 NS 995413 18% confirmed Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. Mtr. 20.00 Included 0.00 0 0
9.0 CONDUITS Revaluation of J column Tax Calculation
9.1 NS 995413 18% confirmed Supply and installation of various sizes of PVC/ MS conduits ISI make with fish wire, concealed in wall / floor including chipping chasing and allied civil works. Finishing shall be limited to rough plastering only. 19mm dia 1.8mm thick PVC conduit Mtr 20.00 Included 0.00 0 0
9.2 NS 995413 18% confirmed Supply and installation of various sizes of PVC/ MS conduits ISI make with fish wire, concealed in wall / floor including chipping chasing and allied civil works. Finishing shall be limited to rough plastering only. 25mm dia 1.8mm thick PVC conduit Mtr 20.00 Included 0.00 0 0
9.3 NS 995413 18% confirmed Supply and installation of various sizes of PVC/ MS conduits ISI make with fish wire, concealed in wall / floor including chipping chasing and allied civil works. Finishing shall be limited to rough plastering only. 32mm dia 1.8mm thick PVC conduit Mtr 20.00 Included 0.00 0 0
9.4 NS 995413 18% confirmed Supply and installation of various sizes of PVC/ MS conduits ISI make with fish wire, concealed in wall / floor including chipping chasing and allied civil works. Finishing shall be limited to rough plastering only. 50mm dia 1.8mm thick PVC conduit Mtr 20.00 Included 0.00 0 0
10.0 SAFETY EQUIPMENTS & MISCELLANEOUS Revaluation of J column Tax Calculation
10.1 NS 995413 18% confirmed First aid box complete medical kit. sets 1.00 Included 0.00 0 0
10.2 NS 995413 18% confirmed Supply, installation, testing and commissioning of shielded Co-axial cable for TV sets and terminating to the TV point in PVC conduits. Rate shall be inclusive of allied civil works.---Co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. mts 45.00 Included 0.00 0 0
10.3 NS 995413 18% confirmed Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required--Telephone socket outlet EACH 5.00 Included 0.00 0 0
10.4 NS 995413 18% confirmed Supply, installation, testing and commissioning of shielded 2 pair telephone cable for telephone points in PVC conduits and terminating to the RJ-11 jack. Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required Rate shall be inclusive of allied civil works. mts 60.00 Included 0.00 0 0
10.5 NS 995413 18% confirmed Supply, installation, testing and commissioning of RJ-11 jack and fixing associated accessories as required at site. Rate shall be inclusive of allied civil works. Nos 1.00 Included 0.00 0 0
10.6 NS 995413 18% confirmed Supply, installation, testing and commissioning of RJ-45 jack and fixing associated accessories as required at site. Rate shall be inclusive of allied civil works. Nos 1.00 Included 0.00 0 0
10.7 NS 995413 18% confirmed Supply and installation of anodized Fan hook box Nos 42.00 Included 0.00 0 0
10.8 NS 995413 18% confirmed Supply and installation of 16SWG GI perforated trays of following sizes on supports as required at site and as per drawing. 250mm wide x 50mm height. Mtr 15.00 Included 0.00 0 0
10.9 NS 995413 18% confirmed 6 Kg dry chemical powered type Portable Fire extinguisher 5.00 Included 0.00 0 0
11.0 LIGHT FITTINGS / FANS Revaluation of J column Tax Calculation
Supply, installation, testing and commissioning of following light fixtures with all accessories. Rate shall include of necessary support arrangement as required at site. Revaluation of J column Tax Calculation
11.1 NS 995413 18% confirmed Supply, installation, testing and commissioning of 20W 1200mm long box type LED tube light fitting with electronic driver CRI>80% & THD<10% in metal housing with all required accessories as per site condition. Nos 90.00 Included 0.00 0 0
11.2 NS 995413 18% confirmed 1400mm sweep ceiling fan with support rod, clamp and other related accessories as per site condition Nos 50.00 Included 0.00 0 0
11.3 NS 995413 18% confirmed Supply, installation, testing and commissioning of 25W LED street light fitting suitable for fixing in the above pole. The light output shall be white without any reflectors. Similar to Jaguar make LSRT02S025XX Nos 6.00 Included 0.00 0 0
11.4 NS 995413 18% confirmed Supply installation testing and commissioning of 18W LED suface mounted ceiling light fitting with all required accessories as per site condition. Nos 5.00 Included 0.00 0 0
11.5 NS 995413 18% confirmed Supply installation testing and commissioning of 18W LED wall mounted bulk head outdoor type light fitting with all required accessories as per site condition. Nos 15.00 Included 0.00 0 0
11.6 NS 995413 18% confirmed Supply installation testing and commissioning of 350mm sweep PVC exhaust fan with all required accessories as per site condition. Nos 8.00 Included 0.00 0 0
Outdoor Electrification Revaluation of J column Tax Calculation
Outdoor Electrification-DISTRIBUTION BOARDS / MCB/ SOCKETS Revaluation of J column Tax Calculation
1 NS 995413 18% confirmed Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole Nos 12.00 Included 0.00 0 0
Outdoor Electrification-Cables Revaluation of J column Tax Calculation
1 NS 995413 18% confirmed Supply, Erection, Testing and commissioning of LT XLPE insulated 1.1 kV grade Armored conductor cables of following sizes. Rate shall be same for clamping on the wall, laying on trays, trenches, ducts and as per the site conditions. 4C x 6 sq.mm Al. Ar. LT XLPE cable Mtr 1715.00 Included 0.00 0 0
Outdoor Electrification-Terminations Revaluation of J column Tax Calculation
1 NS 995413 18% confirmed Supply & terminating the ends of cables of following sizes using Siemens type sigle compression cable glands, crimping type Aluminum/Copper lugs of required size, crimping paste, tapes, bolt nuts, double washers, spring washers, gland earthing clips complete. Each cable shall be identified with cable tags above the panel / DB. Cable shall be properly dressed before termination and bent at an angle of 15 times the radius of the cable. No extra holes shall be made on top of panel and if any made shall be sealed properly. The final tightness at every terminal shall be done with a torque wrench and tightened up to the recommended level. Flexible wires shall be glanded with cast aluminum glands and earthed and connected properly. 4C x 6 sq.mm Al. Ar. LT XLPE cable Nos 136.00 Included 0.00 0 0
2 NS 995413 18% confirmed LT Cable trench - Excavation and backfilling of the sand trench along the side of the road. The trench shall be 750mm deep 450mm wide. The bottom shall be filled one layer of 75mm fine river sand and cables shall be laid on top of it. On the laid cables one more layer of 75mm thick river sand , underground utility marking tape (ESB marker red color PVC tape shall be laid on top of it without any gap. The trench shall be backfilled, watered and rammed to suit original level. Mtr 650.00 Included 0.00 0 0
Outdoor Electrification-LIGHT FITTINGS Revaluation of J column Tax Calculation
1 NS 995413 18% confirmed Supply, installation, testing and commissioning of Street light single arm pole with civil foundations. The projected portion above ground shall be 6 mts. Rate shall be inclusive of pole, excavation, concreting, backfilling, coping, Interconnecting cable, wiring , junction box with MCB, coil earthing with 8 SWG G.I wire etc. The pole shall be supplied with control gear and all accessories. Excavation of trenches shall be covered separately. Nos 30.00 Included 0.00 0 0
2 NS 995413 18% confirmed Supply, installation, testing and commissioning of Street light double arm pole civil foundations. The projected portion above ground shall be 6 mts. Rate shall be inclusive of pole, excavation, concreting, backfilling, coping, Interconnecting cable, wiring , junction box with MCB, coil earthing with 8 SWG G.I wire etc. The pole shall be supplied with control gear and all accessories. Excavation of trenches shall be covered separately. Nos 1.00 Included 0.00 0 0
3 NS 995413 18% confirmed Supply, installation, testing and commissioning of Street light single arm wall mounted pole. The shall be mounted at from above ground shall be 1.5 mts. Rate shall be inclusive of pole, excavation if any, chasing of wall, Interconnecting cable, wiring , junction box with MCB, earthing with 8 SWG G.I wire etc. The pole shall be supplied with control gear and all accessories. Excavation of trenches shall be covered separately if any. Nos 11.00 Included 0.00 0 0
4 NS 995413 18% confirmed Supply, installation, testing and commissioning of 25W LED street light fitting suitable for fixing in the above poles. The light output shall be white without any reflectors. Similar to Jaguar make LSRT02S025XX Nos 68.00 Included 0.00 0 0
Total for Civil & Electrical Portion 0.00 0
Total GST Tax as confirmed by Bidder 0.00
Grand Total including GST 0.00
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule - 2 Dis
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address (Bidder) : To: As per Percent on Sch-2 #REF!
Sr.GM , Contracts & Materials Department, Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : SRTS-II, RHQ
Singanayakanahalli Multipackage Discount #REF!
Bengaluru-560064
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total F&I Price #REF!
Place : Printed Name :
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule - 3
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : ERECTION CHARGES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Bidder) : To: As per Percent on Sch-3 #REF!
Sr.GM , Contracts & Materials Department, Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : SRTS-II, RHQ
Singanayakanahalli Multipackage lum-sum #REF!
Bengaluru-560064
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! (a) Detailed Soil Investigation
#REF! #REF! #REF! #REF! #REF! (b) All kinds of soil except fissured rock & hard rock
#REF! #REF! #REF! #REF! #REF! (e) River Crossing Location
#REF! #REF! #REF! #REF! #REF! (f)
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
Total Erection Price (A+B) #REF!
Place : Printed Name :
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule - 4
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Bidder) : To:
Sr.GM , Contracts & Materials Department,
Name : Power Grid Corporation of India Ltd.,
Address : SRTS-II, RHQ
Singanayakanahalli
Bengaluru-560064
TOTAL TRAINING CHARGES 0.00
Date : -- Printed Name :
Place : Designation :
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule - 5
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Bidder) : To:
Sr.GM , Contracts & Materials Department,
Name : Power Grid Corporation of India Ltd.,
Address : SRTS-II, RHQ
Singanayakanahalli
Bengaluru-560064
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST ON Service Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Services between the Contractor and the Employer (identified in Schedule 1') which are not included in the Unit price as per the provision of the Bidding Documents, as applicable. 0.00
2 TOTAL GST ON GOODS
Total GST on AMC charges
Date : --2023 Printed Name :
Place : Designation :
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule - 5
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Bidder’s Name and Address (Bidder) : To:
Sr.GM , Contracts & Materials Department,
Name : Power Grid Corporation of India Ltd.,
Address : SRTS-II, RHQ
Singanayakanahalli
Bengaluru-560064
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST ON GOODS #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST ON SERVICES #REF!
Total GST on Installation Services (Schedule-3) and Training to be imparted in India (Schedule-4)
GRAND TOTAL [1+2] #REF!
Date : --2023 Printed Name :
Place : Designation :
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule - 6
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR
(GRAND SUMMARY)
Bidder’s Name and Address (Bidder) : To:
Sr.GM , Contracts & Materials Department,
Name : Power Grid Corporation of India Ltd.,
Address : SRTS-II, RHQ
Singanayakanahalli
Bengaluru-560064
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment
2 TOTAL SCHEDULE NO. 2 0.00
RATES AND PRICES : FREIGHT & INSURANCE CHARGES
1 TOTAL SCHEDULE NO. 3 0.00
Service/ Installation
2 TOTAL SCHEDULE NO. 5 0.00
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2] 0.00
Date : --2023 Printed Name :
Place : Designation :
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Schedule 7
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Bidder) : To: As per Percent on Sch-7 #REF!
Sr.GM , Contracts & Materials Department, Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : SRTS-II, RHQ
Singanayakanahalli Multipackage Discount #REF!
Bengaluru-560064
Type test Charges
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) #REF! Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
TOTAL TYPE TEST CHARGES 0.00
Dis Alert #REF!
Date : --2023 Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
SRTS-II/C&M/WC-3660/NIT-218(E)/2023
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR 0 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0 0
Bidder’s Name and Address (Bidder) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
SRTS-II/C&M/WC-3660/NIT-218(E)/2023
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Bidder) : To: As per Percent on Sch-7 #REF!
Sr.GM , Contracts & Materials Department, Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : SRTS-II, RHQ
Singanayakanahalli Multipackage Discount #REF!
Bengaluru-560064
Type Tests on Earthwire
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
Sub-Total (I) #REF!
TOTAL TEST CHARGES (I) #REF!
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : --2023 Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
SRTS-II/C&M/WC-3660/NIT-218(E)/2023
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR 0 0 0
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) 0 0 0
Bidder’s Name and Address (Bidder) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
SRTS-II/C&M/WC-3660/NIT-218(E)/2023 Bid Form Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Price bid) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : --2023 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Sr.GM , Contracts & Materials Department, 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
SRTS-II, RHQ 11 th 11 November
Singanayakanahalli 12 th 12 December
Bengaluru-560064 13 th
Name of Contract : Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 1 Plant and Equipment 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 4 Training charges for training to be imparted. 24 th
Schedule 5 Taxes and Duties not included in Schedule 1 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
Schedule 7 Break-up of Type Test Charges for Type Tests to be conducted 27 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : --2023 Printed Name :
Place : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges #REF! #REF!
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) #REF! #REF!
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! 0.00
B) CENTRAL SALES TAX #REF! 0.00
C) VAT #REF! 0.00
D) ENTRY TAX / OCTROI #REF! 0.00
F) TOTAL TAXES & DUTIES #REF! 0.00
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
#REF! Excise Duty #REF! #REF!
#REF! CST #REF! #REF!
#REF! VAT #REF! #REF!
#REF! Entry Tax/ Octroi #REF! #REF!
Others as Others
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0
b) Excise Duty, as applicable on (a) above at the rate : 10.00% Rs. 0
c) Amount on which Sales Tax is applicable 0.00 0
d) CST, as applicable on (a) + ED (b) above at the rate : 2.00% Rs. 0
e) VAT, as applicable on (a) + ED (b) above at the rate : 1.00% 0
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. 0
h) Entry Tax, as applicable on (e) above at the rate : Rs. 0.00
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR Statement of Quoted / Corrected Prices Page
Spec. No. SRTS-II/C&M/WC-3660/NIT-218(E)/2023
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges #REF! #REF!
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) #REF! #REF!
6 DISCOUNT #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! #REF!
B) CENTRAL SALES TAX /VAT #REF! #REF!
C) ENTRY TAX / OCTROI #REF! #REF!
D) OTHERS #REF! 0.00
E) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
a) Excise Duty Rs. #REF!
b) CST /VAT Rs. #REF!
c) Entry Tax / Octroi Rs. #REF!
d) Others Rs. #REF!
II) Bidder has offered following discount(s)
III) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated : Details of dicounts
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. #REF! Gross LS #REF! #REF! #REF! Gross % #REF! #REF! #REF!
b) Excise Duty @ 10.3% of (a) above Rs. #REF! #REF! #REF!
c) CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above Rs. #REF! Sch-1 Direct LS #REF! #REF! #REF! Sch-1 Direct % #REF! #REF! #REF!
d) Others Rs. Sch-1 BO LS #REF! #REF! #REF! Sch-1 BO % #REF! #REF! #REF!
e) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF! Sch-2 LS #REF! #REF! #REF! Sch-2 % #REF! #REF! #REF!
f) Entry Tax @ 1% of (e) above Rs. #REF! Sch-3 LS #REF! #REF! #REF! Sch-3 % #REF! #REF! #REF!
Sch-7 LS #REF! #REF! #REF! Sch-7 % #REF! #REF! #REF!
Construction of Hostel Building, Roads, Drains, Internal and External Electrification for ITI Complex at Perumbakkam Chennai under CSR Statement of Quoted / Corrected Prices Page Different Manner #REF!
Text for Discount #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
First Envelope and Bid forms.xlsx
xlsx • 1.83 MB
Road layout drawing ITI Chennai.pdf
pdf • 1.26 MB
SFQP.pdf
pdf • 2.22 MB
Column lay out.pdf
pdf • 0.69 MB
Electrical layout drawing ITI CSR.pdf
pdf • 1.23 MB
Foundation lay out.pdf
pdf • 0.70 MB
Lintel lay out & details.pdf
pdf • 0.75 MB
List of Approved Manufacturers for LT Electrical Works.pdf
pdf • 0.19 MB
Plinth beam layout & details sheet 1 of 2.pdf
pdf • 0.72 MB
Plinth beam layout & details sheet 2of 2.pdf
pdf • 0.64 MB
Roof beam lay out & details sheet 1 of 2.pdf
pdf • 0.74 MB
Roof beam Layout &details sheet 2 of 2.pdf
pdf • 0.66 MB
Slab lay out.pdf
pdf • 0.69 MB
Stair case & water tank details sheet 3 of 3.pdf
pdf • 0.63 MB
Stair case beam lay out 1 of 3.pdf
pdf • 0.68 MB
Stair case details sheet 2 of 3.pdf
pdf • 0.69 MB
Technical Specification.PDF
pdf • 0.64 MB
Tie beam lay out & details sheet 1 of 2.pdf
pdf • 0.73 MB
Tie beam lay out & details sheet 2 of 2.pdf
pdf • 0.66 MB
02_Section-II_Instructions to Bidders (ITB)_PRANIT_July 2021.pdf
pdf • 0.75 MB
1_ Invitation for bids(Section-I).pdf
pdf • 0.19 MB
3A-Annexure-A(BDS)-QR.pdf
pdf • 0.15 MB
3B-Annexure-B(BDS)_Vol-I.pdf
pdf • 0.14 MB
3C-Annexure-C(BDS)_Vol-I.pdf
pdf • 0.14 MB
3_ Bid Data Sheet(BDS)-Section-III.pdf
pdf • 0.34 MB
4.Conditions of Contract_Civil Works-Section-IV.pdf
pdf • 0.39 MB
4A_GCC Civil_ Amendments I - X.pdf
pdf • 3.64 MB
5.Special Conditions of Contract (SCC)-Section-V.pdf
pdf • 0.20 MB
Attachemnt-21_Affidavit for self-certification.DOCX
docx • 0.02 MB
Attachment 24- Certificate by Bidder.docx
docx • 0.02 MB
Attachment-18-SAFETY PACT.docx
docx • 0.04 MB
Attachment-20-KMP Delaration..doc
doc • 0.03 MB
Attachment-23_Declaration regarding events encountered pursuant to ITB Clause 2.1.docx
docx • 0.03 MB
Integrity_Pact_Format.doc
doc • 0.06 MB
Vol-I_Annexures A to B(SCC).docx
docx • 0.02 MB
Price_schedule.xlsx
xlsx • 1.34 MB
RFx_Extn-2_PDF.pdf
pdf • 0.02 MB
RFx_Extn-1_PDF.pdf
pdf • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .