| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L1 | Accepted-AOC L1 accepted bidder | |
| 2 | L2₹24.0 L+₹17,134.90 (0.72%)Rejected-Finance DT 2660 PANI TANKI DHURVA RANCHI JHARKHAND | RANCHI | RANCHI | JHARKHAND | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹25.3 L+₹1.5 L (6.13%)Rejected-Finance AT SUNDER NAGAR PO BHURKUNDA DT RAMGARH JHARKHAND 829106 | BHURKUNDA | RAMGARH | JHARKHAND | 829106 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹27.3 L+₹3.5 L (14.7%)Rejected-Finance VIDYA NAGAR SUKHDEO NAGAR ROAD NO 3 HARMU RANCHI 834002 | RANCHI | RANCHI | JHARKHAND | 834002 | L4 | Rejected-Finance Not being L1 |
Tender Value
₹38.5 L
EMD Value
₹48,200
Closing Date
20 Feb 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GM(Civil)/TA
Town Admin Deptt, CCL HQ , Ranchi- 834029
Replacement of Main panel /distribution panel and electrical works at different building at DHC, CCL, Ranchi.
2023_CCL_269688_1
CCL/TA/Tender/EnM/22-23 /5243-53 Dt. 30.01.2023
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
CCL, Darbhanga House, Ranchi
As per NIT
5 documents required · 5 mandatory
₹48,200
29 Apr 2023
7 Feb 2023
21 Feb 2023
8 Feb 2023
20 Feb 2023
8 Feb 2023
8 Feb 2023 - 14 Feb 2023
Amount
Item Description/ Heading
Providing and installation of G frame panel Board / Enclosure, O/G FP,MCCBs G-Frame, 400 AMP, LS Frame MCCB incomer and 8 way Four pole out going double door without incoming and out going MCCB/MCB.Make : Havells or equivalent, confirming to IS 8623,IEC-61439.(Analysed Rate)
Providing and installation of G frame panel Board / Enclosure, O/G FP, MCCBs G-Frame ,250 AMP, LS Frame MCCB incomer and 8 way Four pole out going double door without incoming and out going MCCB/MCB.Make : Havells or equivalent, confirming to IS 8623,IEC-61439.(Analysed Rate)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 400 AMP, 35 KA,FP.(Analysed Rate)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 AMP, FP. (Analysed Rate)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 AMP,35 KA, FP.(Analysed Rate)
Providing and fixing following rating and breaking capacity and pole MCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 63 AMP, FP.(Analysed Rate)
Providing and laying of 6 sq mm , 2 core armoured , cross linked polyethene and XLPE,inner sheathed -thermoplastic, galvanised steel formed wire,single wire armouring with Aluminium conductor for voltage at 1.1 KV, make Havells, polycab, or equivalent. AS per is 7098 (part-1)1988 latest.(Analysed Rate)
Providing and laying of 35 sq mm , 4 core armoured , cross linked polyethene and XLPE,inner sheathed -thermoplastic, galvanised syeel formed wire,single wire armouring with Aluminium conductor for voltage at 1.1 KV,make Havells, polycab, or equivalent. AS per is 7098 (part-1)1988 latest.(Analysed Rate)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm (refer CPWD DSR E&M-18 7.1.1)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(ISI Marked) Group A. (refer CPWD DSR E&M-18 1.10.1)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(ISI Marked) Group B (refer CPWD DSR E&M-18 1.10.2)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C (refer CPWD DSR E&M-18 1.10.3)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (ISI Marked) 2X 1.5 sq.mm. + 1 X 1.5 sq .mm. earth wire.(refer CPWD DSR E&M-18 1.14.1)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(ISI Marked) 2X 2.5 sq.mm. + 1 X 2.5 sq .mm. earth wire.(refer CPWD DSR E&M-18 1.14.2)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (ISI Marked) 2X 10 sq.mm. + 1 X 6 sq.mm. earth wire. (refer CPWD DSR E&M-18 1.14.5)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch. (refer CPWD DSR E&M-18 1.24.1)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch.(refer CPWD DSR E&M-18 1.24.3)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket.(refer CPWD DSR E&M-18 1.24.4)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket. (refer CPWD DSR E&M-18 1.24.5)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.(refer CPWD DSR E&M-18 2.10.1)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole & neutral. (refer CPWD DSR E&M-18 2.10.5)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm) .(refer CPWD DSR E&M-18 1.27.3)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm). (refer CPWD DSR E&M-18 1.27.6)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (refer CPWD DSR E&M-18 1.25)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door. (refer CPWD DSR E&M-18 2.3.3)
providing and fixing of recessed ceiling mounted LED light fitting 15 watt 5700K high efficiency powder coated white finish in round profile ,Make Philips/ Crompton/Havel’s/ HPL.or equivalent. (Analysed Rate)
Providing and fixing of recessed mounting LED round pannel down light 18/20 watt.Make Crompton , Havells, Bajaj,Philips or equivalent. Including making suitable arrangement for fixing on ceiling of hight 30 to 40 fit approx. in side Auditorium.(Analysed Rate)
Providing and fixing of recessed mounting LED round pannel down light 18/20 watt.Make Crompton , Havells, Bajaj, philips, or equivalent.(Normal height) (Analysed Rate)
Providing and fixing of garden light 10 watt inverted pyramind tripod type LED Bolard ,Make : Crompton, Philips, or equivalent similar to existing garden light. (Analysed Rate)
Total impact of GST for the purpose of CTC
SEEMA CONSTRUCTION
M/S B.N. PANDEY
HANS ELECTRICALS
stage.html
html • 0.04 MB
techsummary_279034.pdf
PDF • 2.91 MB
finsummary_279034.pdf
PDF • 2.91 MB
AWARD30.pdf
PDF • 5.23 MB
finance_279034.pdf
PDF • 0.29 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .