Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | ₹13.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹13.6 L+₹12,208.30 (0.91%)Rejected-Finance | ₹13.6 L+₹12,208.30 (0.91%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹13.7 L+₹19,008.30 (1.41%)Rejected-Finance | ₹13.7 L+₹19,008.30 (1.41%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹14.0 L+₹52,548.30 (3.90%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | ₹14.0 L+₹52,548.30 (3.90%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹14.3 L+₹85,958.30 (6.38%)Rejected-Finance | ₹14.3 L+₹85,958.30 (6.38%) | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/S SHEIKH FEROOZ AHMAD L4 | FG CONSTRUCTION L7 | M/S ASHRAF CONSTRUCTIONS L6 | JK BUILDERS AND ENGINEERS L3 | YATTOO ENTERPRISES L5 | AAR KAY BUILDERS L2 | CLASSIC JK SUPPLIERS L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, laying, jointing and testing in repairs XPLE insulated, armoured heavy duty electirc cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 core in trenches, through pipe, under culvert or in air complete all as specified and directed. | 200 | RM | 333 ₹66,600 | 340 ₹68,000 | 400 ₹80,000 | 400 ₹80,000 | 300 ₹60,000 Lowest | 550 ₹1,10,000 | 300 ₹60,000 Lowest |
| 2.00 | All as per item Ser No 01 above but 95 Sqmm 3.5 Core | 250 | RM | 770 ₹1,92,500 | 540 ₹1,35,000 | 700 ₹1,75,000 | 900 ₹2,25,000 | 600 ₹1,50,000 | 650 ₹1,62,500 | 390 ₹97,500 Lowest |
| 3.00 | All as per item Ser No 01 above but 120 Sqmm 3.5 Core | 150 | RM | 870 ₹1,30,500 | 710 ₹1,06,500 | 900 ₹1,35,000 | 1,300 ₹1,95,000 | 750 ₹1,12,500 | 950 ₹1,42,500 | 450 ₹67,500 Lowest |
| 4.00 | All as per item Ser No 01 above but 150 Sqmm 3.5 Core | 150 | RM | 970 ₹1,45,500 | 840 ₹1,26,000 | 999 ₹1,49,850 | 1,400 ₹2,10,000 | 950 ₹1,42,500 | 1,050 ₹1,57,500 | 600 ₹90,000 Lowest |
| 5.00 | All as per item Ser No 01 above but 185 Sqmm 3.5 Core | 90 | RM | 1,620 ₹1,45,800 | 890 ₹80,100 | 1,200 ₹1,08,000 | 1,500 ₹1,35,000 | 1,050 ₹94,500 | 1,150 ₹1,03,500 | 700 ₹63,000 Lowest |
| 6.00 | S&F in repairs LT Busbar panel board, outdoor type door cubical type, slopy roof front back both side opening, pedastal mounted overall size not less than 600 x 450 x 25mm, CPRI approved, IP-54 having independent compartment for bus bar, incoming feeder and each outgoing feeders dust and vermin proof and lockable, factory made fabricated out of 3.15mm thick CRCA sheet suitable for 3 phase 415 volts 50 Hz, AC supply, bus bar chamber with 4 Nos aluminium bus bar of 150 Amps rating for 3 phase and bus bar of same capacity for neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators 01 set including necessary copper cables of suitable size for MCCB/ inter connections, common earth bus bar of GI strip 32 x 6mm at bottom with independent plates at bottom for each outgoing and incoming cables in cabel alley panel board and painted with powder coating in siemens grey colour and provision for the following incoming and outgoing all accessories :-
NOTES :-
(a) All MCCBs will be measured and paid separately under relevant item of this schedule.
(b) Rates of interconnecting copper/ aluminium cable along with necessary copper/ aluminium lugs are inclusive in the quoted rate.
(c) The dimension of panel given in the schedule are approximate size only. The contractor should obtain necessary approval/ Layout/ Drawing/ General arrangements for panel from AGE (I) prior to commencement of work.
(d) Cost for connecting of existing old underground cable of any size/ type to new incoming/ outgoing terminals by cutting the required length. Addition/ altration and provision of necessary cable lugs, cable glands, nuts & bolts etc shall be included in the quoted rates. | 9 | Each Job | 8,000 ₹72,000 Lowest | 48,500 ₹4,36,500 | 10,000 ₹90,000 | 9,000 ₹81,000 | 18,000 ₹1,62,000 | 23,000 ₹2,07,000 | 30,000 ₹2,70,000 |
| 7.00 | M&L Earthing complete with GI earth plate of size 60cm x 60cm x 6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below normal ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip of size 25x4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 and including earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, protection pipe 15mm dia light grade upto 7.5mtr and salt etc. and connected to earthing test point including dismantling of old unserviceable earthing and taking out material, complete all as specified and directed including testing after completion. | 18 | Each Set | 4,000 ₹72,000 | 4,500 ₹81,000 | 4,000 ₹72,000 | 2,000 ₹36,000 Lowest | 4,000 ₹72,000 | 3,000 ₹54,000 | 6,000 ₹1,08,000 |
| 8.00 | S&F MCCB 4 pole, current rating 400 Amp, adjustable over load and short circuit with micro processing release setting, breaking capacity of 16 KA at 415 V, 50 Hz, complete all as specified and directed. | 15 | Each | 11,000 ₹1,65,000 Lowest | 20,000 ₹3,00,000 | 22,000 ₹3,30,000 | 11,000 ₹1,65,000 Lowest | 19,000 ₹2,85,000 | 14,000 ₹2,10,000 | 15,000 ₹2,25,000 |
| 9.00 | All as per item No 08 above but 4 pole 200 Amps having breaking capacity 36 KA | 6 | Each | 7,000 ₹42,000 | 5,800 ₹34,800 Lowest | 22,000 ₹1,32,000 | 7,000 ₹42,000 | 14,000 ₹84,000 | 6,500 ₹39,000 | 9,000 ₹54,000 |
| 10.00 | All as per item No 08 above but 4 pole 160 Amps having breaking capacity 36 KA | 5 | Each | 5,496 ₹27,480 | 4,800 ₹24,000 | 6,000 ₹30,000 | 4,500 ₹22,500 Lowest | 9,000 ₹45,000 | 5,000 ₹25,000 | 8,000 ₹40,000 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Apr 2026, 6:00 pmClosed
Col P Canon Anal CWE
HQ 134 WE C/o 56 APO PIN-914134
REPAIR AND MAINT OF LT EXTERNAL ELECTRICAL WORKS MCCBs WITH PANEL UG CABLE OF SECTOR A OF SHARIFABAD MIL STN UNDER AGE (I) CIF (K)
2026_MES_759663_1
134WE-01(T)/2026-27
Open Tender
Civil Works - Others
Item Rate
180 days
AGE (I) CIF (K)
All as per tender dcuements
8 documents required · 8 mandatory
₹500
AGE (I) CIF (K)
₹40,000
2 Jun 2026
9 Apr 2026
2 May 2026
9 Apr 2026
30 Apr 2026
23 Apr 2026
9 Apr 2026 - 16 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Supply, laying, jointing and testing in repairs XPLE insulated, armoured heavy duty electirc cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 core in trenches, through pipe, under culvert or in air complete all as specified and directed. | - | RM | - | - |
| - | All as per item Ser No 01 above but 95 Sqmm 3.5 Core | - | RM | - | - |
| - | All as per item Ser No 01 above but 120 Sqmm 3.5 Core | - | RM | - | - |
| - | All as per item Ser No 01 above but 150 Sqmm 3.5 Core | - | RM | - | - |
| - | All as per item Ser No 01 above but 185 Sqmm 3.5 Core | - | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
PS01.pdf
Tender Documents • 1.09 MB
BOQ_850874.xls
BOQ • 11.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .