| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.2 LAccepted-AOC HOSUE NO 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 MP | GWALIOR | MADHYA PRADESH | 474005 | 1 | Accepted-AOC being lowest | |
| 2 | 2₹25.6 L+₹2.7 L (12.0%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | 2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | 3₹26.8 L+₹3.9 L (17.2%)Rejected-Finance | 3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | 4₹29.9 L+₹7.0 L (30.7%)Rejected-Finance | 4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | 5₹31.9 L+₹9.1 L (39.8%)Rejected-Finance | 5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Jul 2024, 6:00 pmClosed
GE (AF) TECH AREA GWALIOR
GE (AF) TECH AREA GWALIOR
REPAIRS/MAINT OF CERTAIN LT PANELS, ACBs AND AT RECEIVING SUBSTATION IN WEST WING TECH AREA AT AF STATION GWALIOR
2024_MES_663011_1
8900/1553/GWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GWALIOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) TECH AREA GWALIOR
₹90,000
Yes
31 Aug 2024
29 Jun 2024
18 Jul 2024
29 Jun 2024
16 Jul 2024
9 Jul 2024
Amount
M&L for fabrication/welding/Jointing work in existing LT Panel by providing new hinges in place of defective hinges, replacement of locking arrrangement of external door, replacement of main door gasket, replacement of rusted sheet cover including cutting, bending, Welding/soldering and refixing properly at site. Servicing and maintenance of the panel by taking out the incoming connection and all outgoing connection and outgoing cables of the panel and fixing a fresh with proper crimping/tapeing, lux/connector, cable gland including doing all necessary wiring in the panel. Note -Excavation and earth work wherever necessary is deemed to be inculded alongwith the cost and MS Sheet will be measured and paid seperately under respective item
Dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/panel boards etc and supply and fixing new cold rolled medium weight mild steel hinges in position as per existing requirement with necessary spot welding, screwing etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed.
Taking out old unserviceable insulator from LT panel boards, supply, fixing & testing conical/single bus bar system epoxy insulator including nuts, bolts and washers suitable for LT 415 Volts, 50 Hz AC supply for mounting of bus bars in LT panels/feeder pillar boxes complete all as specified and directed
Replacement of existing unserviceable/damaged part/portion of the existing feeder pillar box/ panel boards with supply and fixing new part or portion fabricated out of 3 mm thick MS sheet in position including making necessary adjustments and alignments to make the existing feeder pillar box/panel board body to required shape and size(s) and MS sheet painted both sides with two coats of synthetic enameled paint over a coat of red oxide primer with necessary filler coating complete all as specified ant directed.
Disconnecting and taking out old existing unserviceable Phase indicator lamps and supply, fixing, connecting and, testing LED type Phase indicator lamp with showing red, yellow and green colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using suitable size copper cables wires and lugs complete all as specified and directed.
M & L for preparation of old steel surfaces of steel/LT panel boards/feeder pillar boxes of size upto 1000mm x 1100mm x 450mm of any description & any position including removing disintegrated/detoriating part of paint and applying filler coat to obtain smooth surfaces and applying a coat of synthetic enamel paint using spray machine to obtain smooth finish to the entire satisfaction of Engineer-in-Charge complete all as specified and directed.
All as per items No 7 here-in-before but of size above 1000mm x 1100mm x 450mm less than 1300mm x 1450mm x 450mm complete all as specified and directed.
All as per item No 8 here-in-before do- but size of above 1300mm x 1450mm x 450mm complete all as specified and directed.
Supply, Install, Testing and Commissioning in repair CPRI approved cubical type LT Panel floor mounted out door type for 415V, 3 phase 4 wire system 50 Hz AC supply with Aluminium bus bar duly colour coded, for neutral supported with DMC/SMC insulators colour coded with heat shrinkable sleeve having short circuit current with stand minimum 21 KA for one second complete connection from bus bar to breakers with suitable copper cable , factory made fabricated with CRCA sheet totally enclosed, dust weather and vermin proof for outer shell and 3.15 mm thick with canopy , inner shell having TPN Aluminium bus bar rating 1.5 times that of controlling MCCB supported on SMC insulator with short circuit withstand capacity 35 MVA for 1 second, bottom base channel MS section not less than 100mm x 50mm x 5 mm thick, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size of copper wiring with minimum 1.5 Sqmm PVC insulated copper conductor cable , cable alleys, cable gland plates in two half , general construction confirming to IS-8623/93 and mounted on suitable PCC foundation for the complete panel base with follwoing detailed specification & control complete with suitable fixing accessories. Note: The cost of dismantling the existing LT panel is deemed to be included in the quoted rate.
OUTER SHELL:- The outer shell shall be made of 3.15 mm thick CRCA body & MS angle section 50x50x6 mm frame with front & back openable, single door system lockable/ openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of glands. The dimension of the outer shell should be adequate to accommodate the inner shell described below 50 mm space all around and shall be fabricated in such a way that the complete inner shell with its control gears and accessories should be taken outside without disturbing the outer shell. The outer shell shall be mounted on a zinc metal-coated stand. Provision of threaded earthing studs at the bottom and lifting lugs of suitable size at the top to lift the feeder pillar box safely shall be made. Computer-cut self-adhesive vinyl danger notice plate having a conventional symbol of bone and skull shall be provided. The degree of protection of outer shell shall be IP-54.
(A) Incoming:- (a) MCCB 4P,400 Amp, 25KA -01 No (Thermal magnetic type) (b) Indicating lamps for three phases - Qty 1 set of 3 Nos (c) Multifunction meter - 01 Nos (B) Outgoing:- (a) MCCB 4P, 100A, 16KA -03 Nos (Thermal magnetic type) (b) MCCB 4P, 63A, 16KA -03 Nos (Thermal magnetic type) Note:- The rate includes the cost of earthwork and PCC for grouting the panel with angle iron of size 50 x 50 x 6 mm, 90 CM below the ground level and 60 CM above the ground level.
All as per the item No 11 but with the following switch gears with incoming and outgoing (A) Incoming:- (a) MCCB 4P,200 A, 25 KA -01 (Thermal magnetic type) (b) Indicating lamps for three phases - Qty 1 set of 3 Nos (B) Outgoing:- (a) MCCB 4P, 100A, 16KA -03 Nos (Thermal magnetic type) Note:- The rate includes the cost of earthwork and PCC for grouting the panel with angle iron of size 50 x 50 x 6 mm, 90 CM below the ground level and 60 CM above the ground level.
Disconnecting, taking out and removing old existing unserviceable underground, LT XLPE/PVC insulated Aluminium conductor cable of any description and in any position complete including taking down existing protection pipe etc, for the following sizes from ducts / trenches / poles /pipes etc complete all as specified and directed :- (a) 16 Sqmm to 35 Sqmm, 4 or 3 ½ core
(b) 50 to 95 Sqmm, 3 ½ core
(c) 120 to 240 Sqmm, 3 ½ core Note:- Excavation and earth work for taking out the cable shall be measured and paid for separately under appropriate item of Schedule `A'
Re-laying, jointing and testing of serviceable retrieved LT cable from item No. 1 above (after thorough inspection of cable) XLPE / PVC insulated, armoured, heavy duty, aluminum conductor cable 1100 Volts grade of any description, laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes :- Note: Excavation returning refilling will be paid and separately under relevant items.
(a) 16 Sqmm to 35 Sqmm, 4 or 3 ½ core
(b) 50 to 95 Sqmm, 3 ½ core
(c) 120 to 240 Sqmm, 3 ½ core
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and getting out in any type soil etc complete all as specified and directed.
Sand cushioning and spreading clean, dry, fine river sand for UG electric cable in two layers (8 cm thick before laying the cable & 15 cm thick after laying cable) total 23 cm thick including gentle punning the sand upto 18 cm (total thickness) and consolidated around cable for protection of under ground cable complete all as specified and directed. (Note :- Only punned down thickness shall be measured for payment).
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in soft/loose soil etc complete as specified and directed.
Removing of surplus excavated soil not exceeding 50 M distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply & Laying PCC cable covers for protection of cable cover LV low voltage type -I flat ISI marked of size 250 mm x 150 mm x 40 mm complete all as specified and directed by Engr-in-charge. Make :- Mahatab/Ravi/Duracoat
M&L for PCC type C1 (1:3:6) (using 40mm graded aggregate) for foundation of poles struts & stay assembly etc complete all as specified and as directed.
M&L for PCC (1:3:6) type C1 in coping of poles etc (using 20mm graded coarse aggregate) including fair finishing the exposed surface even and smooth without using extra cement and necessary form work for coping of poles all as specified and directed for the following
(a) For coping of new erected poles
(b) For repiar of existing coping of poles
M&L in repair of Cable jointing kit for 1.1 KV cable for straight-through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 16 sqmm complete all as specified and as directed.
M&L in repair of Cable jointing kit for 1.1 KV cable for straight-through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured luminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and as directed.
M&L in repair of Cable jointing kit for 1.1 KV cable for straight-through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm complete all as specified and as directed.
M&L in repair of Cable jointing kit for 1.1 KV cable for straight-through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 sqmm to 185 sqmm complete all as specified and as directed.
M&L in repair of Cable jointing kit for 1.1 KV cable for straight-through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 sqmm complete all as specified and as directed.
M&L boring of holes under road, pavement, hard standing by manually depth not less than 75 cm for insertion of GI Pipe of size 80 mm bore light grade for short length complete all as specified and directed. Note :- GI pipe 40 mm dia light grade shall be measured and paid separately under relevant item of Schedule 'A'.
M&L for Supplying, Laying, jointing, and testing XLPE insulated, armored, heavy-duty, aluminum conductor cable 1100 volts grade, laid in trenches/ducts, floors, fixed to walls, etc. complete all as specified and directed for the following sizes :-. Note:- The cost of taking down the old unserviceable LT cable is deemed to be included in the quoted rate (a) 16 Sqmm, 4 core
(b) 25 Sqmm, 4 core
(c) 35 Sqmm 3 ½ core
(d) 50 Sqmm 3 ½ core
(e) 70 Sqmm 3 ½ core
(f) 95 Sqmm 3 ½ core
(g) 120 Sqmm 3 ½ core
(h) 150 Sqmm 3 ½ core
(j) 185 Sqmm 3 ½ core
(k) 240 Sqmm 3 ½ core
M&L bus bar box made out of 2mm thick MS sheet, 3 Phase, 4 wire, 415 volts AC supply outdoor cubical type, dist and vermin proof, floor block mounting type suitable for outdoor applications of size 600mm x 600mm x 450mm, using 40mm x 40mm x5mm angle iron frame with shutter and locking arrangement painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer (internally and externally) for box, height above ground 600mm and graouted 300mm below ground, legs of frame shall be grouted in PCC 1:2:4 (size 300 x 300 x 300mm block) and complete includig 40mm x 10mm 04 nos 500 mm long aluminium busbar fixed on insulators with proper colour coding including making connecteions with cable of size 300 sqmm with necessary lugs and chromium plated glands complete all as specified and directed.
M& L Cutting & removing of grass/ shrubs / plants / bushes /Trimming of tree stems etc around the pole / LT panels / earthing pits complete all as specified and directed.
S&F in repair danger notice plate of size 20x 15 cm,1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT complete all as specified & directed.
Dismantling and taking down existing unserviceable / deshaped / worn out LT steel tubular pole of any shape, size & height including demolition of existing PCC foundation complete all as specified and directed.
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and Including all necessary excavation & earth work in any type of soil for foundation of poles, PCC 1:3:6 type 'C-2' (using 40 mm graded stone aggregate ) in foundations of size 600 X 600 X 1650 mm below GL, PCC 1:2:4 type "B- 1 (using 20 mm graded stone aggregate) in plinth block(coping) of size 600 X 600 X 300 mm above GL , removing surplus soil to a distance n. exc. 50 m & depositing where directed, including necessary form work and 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and numbering of the poles shall be done with synthetic enameled painted letter of shape & size complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as 20x3mm copper strip complete all as specified and as directed
M&L for preparation of old painted surfaces of LT steel tubular pole/strut, of any description and in any position 9.00/8.50 Mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, GI pipe bracket of street/security light, anti climbing devices etc and providing three Nos radium band strips complete all as specified and directed.
Supply and fixing in repair PVC insulated and PVC sheathed twin core Aluminium conductor of size 6.0 Sqmm for connecting from bus bar box to street light fittings/ OH line to street light fitting complete all as specified and directed.
Supply and fixing in the repair of GI Pipe 50 mm dia light grade for cable protection complete all as specified and directed.
Supply and fix in repair Indicating lamps for three phases R,Y,B for LT panel complete all as specified and as directed.
S&F in repair MCCB, 4 pole, 630 Amps current rating and ultimate breaking capacity Icu = 36 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board/LT panels, complete all as specified and directed.
All as per item 43.00 here-in-before but MCCB, 4 pole, 400 Amps current rating and ultimate breaking capacity Icu = 36 KA. complete all as specified and directed.
All as per item 43.00 here-in-before but MCCB, 4 pole, 350 Amps current rating and ultimate breaking capacity Icu = 36 KA. complete all as specified and directed.
All as per item 43.00 here-in-before but MCCB, 4 pole, 250 Amps current rating and ultimate breaking capacity Icu = 36 KA complete all as specified and directed.
All as per item 43.00 here-in-before but MCCB, 4 pole, 160 Amps current rating and ultimate breaking capacity Icu = 36 KA complete all as specified and directed.
All as per item 43.00 here-in-before but MCCB, 3 pole, 125 Amps current rating and ultimate breaking capacity Icu = 16 KA complete all as specified and directed.
All as per item 43.00 here-in-before but MCCB, 3 pole, 100 Amps current rating and ultimate breaking capacity Icu = 16 KA complete all as specified and directed.
M&L for Taking down the existing unserviceable High bay light fittings of any type/capacity from any height of the hangar or any other location with all necessary T&P complete all as specified and as directed.
Supply, fixing, connecting and testing in replacement integral LED High bay light luminaries at any height of building/Hangar ranging from 3m to 16 m, 150 watts, with scondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66 with mounting bracket and all accessories and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable, including all accessories and fixing the light fitting to walls/ ceiling etc complete all as specified and directed.
M&L for breaking the existing damaged coping of existing street lights and M&L for PCC (1:3:6) type C1 in coping of poles etc (using 20mm graded coarse aggregate) including fair finishing the exposed surface even and smooth without using extra cement and necessary form work including one two coats of weather proof paint of approved color complete all as specified and directed.
Supply and fixing in repair onload change over switch 415V in sheet metal enclosure 4 poles 315 Amps Capacity, complete including necessary fixing accessories on wall/panel complete all as specified and directed.
Supply and fixing in repair ON/OFF Load change over switch 415V in sheet metal enclosure 4 pole 400 Amps Capacity, complete including necessary fixing accessories on wall / panel complete all as specified and directed.
S&F in replacement 8 Watt LED bollard light one meter long with Opel acrylic diffuser and IP-65 protection including necessary concreat work complete all as specified and directed.
Supply and replace in repair Aesthetically designed LED post Top with aluminium enclosure, powered with high power LEDs as light source and die casted heat sink exhibits lassic Victorian look with symmetrical light distribution and excellent heat dissipation for long life 35 Watt capacity complete all as specified and as directed.
Supply replace RCC rectangular base cable route indicator of 750mm height 250 mm witdth and 75 mm height at directed location complete all as specified. Note: Necessary excavation, PCC will measured and paid seperately under relevant items
Supply and fix in repair 5 pin and earth plug and socket 125 Amp capacity enclosed in a sheet metal enclosure with MCCB 125 Amp capacity complete as as directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized iron strip of 25 x 4mm as earth continuity conductor by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electric plate No 5, of SSR Part - I, 2009 & all as specified, testing on completion including provision of earth lead protected by 40 mm dia GI pipe medium grade & watering pipe 20 mm medium grade including all excavation and earth work in any type of soil, PCC pit (1:3:6) type C1 with RCC cover, charcoal, salt, funnel etc complete including making good disturbed surfaces of wall, floor. Note : (i) The rate is inclusive of cost of earthing lead of 25 x 4mm and GI protection pipe 40mm size upto 7.5 m length from the top edge of the GI plate electrode. (ii) Irrespective of what is shown on plate No 5 of SSR Part-I /2009, the earthing pit shall be precasted PCC (1:3:6) type C1 and the cover of earthing pit shall be of precast RCC (1 :2 : 4) type B1 with suitable handle fushed with surface all as specified. (iiii) The rates quoted by the contractor is deemed to be inclusive of cost of MS sheet of size 300mmX 300mmX3mm size, fixed with necessary nuts and bolts on angle iron of size 40X40x5mm & length 60cm and grouted in the ground with PCC (1:3:6) using 20mm grade stone masonery of size 200mmX200mmX250mm including necessary earth work.for marking the result and its purpose of use
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required of size 32 x 6mm galvanised iron strip complete all as specified and directed.
M&L for Annual Maintenance of Servo Voltage Stabilizer of following capacity complete with Check transformer oil level & ensure its up to the mark, Tightened input out put cable , Check and clear cable termination box for any foreign substance ( Ex Bird nest , lizards etc),Ensure stabilizer body & neutral connections are properly earthed,Check by increasing & decreasing voltage through control panel and replacing the defective spares and topping up of oil if required including half yearly preventive maintenance Checks and unlimited breakdown visits by qualified technician complete all as specified and directed by Engr-in-charge.
a) Servo Controlled Voltage Stabilizer 100 KVA Capacity
b) Servo Controlled Voltage Stabilizer 150 KVA Capacity
M&L for Annual Maintenance of Isolation transformer of following capacity complete with Check transformer oil level & ensure its up to the mark, Tightened input out put cable , Check and clear cable termination box for any foreign substance ( Ex Bird nest , lizards etc),Ensure transformer body & neutral connections are properly earthed, and replacing the defective spares and topping up of oil if required including half yearly preventive maintenance Checks and unlimited breakdown visits by qualified technician complete all as specified and directed by Engr-in-charge. Note: Topping up of Transformer Oil, replacement of defective spares like Control cards, gears etc are deemed to be included in the quoted rate.
a) Isolation Transformer 100 KVA - 01 Nos
b) Isolation Transformer 200 KVA - 01 Nos
M/s Anupam Construction Co.
BABA DEVELOPERS
Kumar Sales Corporation
M/s Sagar Construction
m/s anil traders
M/S Amit Traders
M/S KAPIL CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .