REPAIR, SERVICING AND PERIODICAL MAINT OF PACKAGE TYPE AND CENTRAL AC PLANT, WATER COOLER, CASSETTE TYPE AC, WINDOW TYPE AC, SPLIT TYPE AC, REFRIGERATOR, DEEP FREEZER, COLD ROOM, ICE MAKING MACHINE AND WATER COOLER PLANT INCL ALLIED WKS AT NDA KHADAK
2021_MES_459783_1
8519/E8
Open Tender
Civil Works
Item Rate
330 days
GE NDA KHADAKWASLA
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE NDA KHADAKWASLA
₹94,000
Yes
29 Oct 2021
14 Jul 2021
11 Aug 2021
14 Jul 2021
9 Aug 2021
23 Jul 2021
15 Jul 2021 - 16 Jul 2021
Amount
Repair /Maintenance of water cooler/ Split AC / Window AC /Cassatte AC/ Package AC/ Refrigerator/ Deep Freezer of any capacity & make installed at various location of NDA in situ as and when required in day-to-day maintenance and making cooling appliences servicible in all respect with replacement of any major or minor parts and obtained signature of users & JE E/M of MES all as specified and directed. The Compressive maintenance comprises with the following and all as directed:- (a) Repairing, Maintenance of Cooling Appliences with required tool and Plant of any make and any capacity/ type in situ by replacing unserviceable parts from the machine checking/repairs to sensor unit and cooling effect of water cooler for proper functioning complete all as specified and as directed. (b) Checking all electric connection from DBs to cooling Appliences, tighten properly all the screw, nut and bolt reqd to be change with help of drilling machine, necessary arc/gas welding as per site reqd necessary making leak proof water supply to the cooler. (c ) Checking serviceability of all fitted parts of cooling Appliences including compressor, blower fan, condensing unit complete, repair it if found unserviceable for smooth functioning and achieve desired cooling effect. (d) Checking the Pressure of refrigerent and recharge where necessary to achieve desired cooling after leak test with nitrogen Gas. (e) Repairs of legs of water cooler and replace if found unserviceable as per the direction. Note: (i) Contractors rep will report to JE E/M / Engr-in-charge on all working days at 9 AM to collect routine/ Urgent job work on complaint slip with all necessary tool and plant. (ii) All job work recieved on complaint slip will be repaired/ checked/ made serviceable then obtain signature of user for satisfactorily completion of Job and then returned to JE E/M / Engr-in-charge on same day of receipt. (iii) Incase of delay in attending the complaint more than 8 Hrs for routine and 3 Hrs for Urgent complaint, the contractor shall be liable to pay the penalty of Rs 500/ per day on account of delay. (iv) If compressor not work properly disconnect electric/water connecton from cooling Appliences and carry it form diffrent site to MES store for repair or after fitting the new compressore and re-installed repaired one on same place and position as per satisfaction/direction. (v) Parts required for replacement shall be measured and paid seperately under appropriate items.
Periodical Servicing of water cooler/ Split AC / Window AC /Cassatte AC/ Package AC/ Refrigerator/ Deep Freezer of any capacity & make installed at various location of NDA in situ as and when due and making cooling appliences servicible in all respect with replacement of any major or minor parts if found U/S and obtained signature of users & JE E/M of MES all as specified and directed. The Periodical Services comprises the following and all as directed:- (a) Servicing of cooling appliences unit outer and inner side complete with vaccume cleaner, soap water, caustic soda, colin etc of any capacity any make and any type in situ by replacing unserviceable parts from the machine checking/repairs to sensor unit and cooling effect of cooling appliences for proper functioning complete all as specified and as directed. (b) Drainout water from inner tank of cooling applience and cleaning the tank thoroughly. (c ) Servicing & cleaning of condensing unit/all filters, dryers complete with vaccume clenear, soap water, castic soda, colin etc of any capacity , any make and any type in situ including, leak testing, brazing the suction / discharge tubes as directed. (d) Any other required Scheduled servicing as recommended by OEM. Note: (i) Contractors rep will report to JE E/M / Engr-in-charge as and when called upon for scheduled servicing of cooling Appliences with all necessary tool and plant. (ii) All job work recieved on complaint slip will be Serviced then obtain signature of user for satisfactorily completion of Job and then returned to JE E/M / Engr-in-charge on same day of receipt. (iii) Incase of delay in attending the said Job for more than 2 days, the contractor shall be liable to pay the penalty of Rs 500/ per day on account of delay. (iv) Parts required for replacement shall be measured and paid seperately under appropriate items.
Taking out burnt blower motor from water cooler and supply and fix new blower motor with blade, single phase, 230V 50Hz, RPM - 1325, suitable for 40/80ltr, 60/80 Ltr water cooler complete all as directed.
Taking out burnt blower motor from water cooler and supply and fix new blower motor with blade, single phase, 230V 50Hz, suitable for 120/150 Ltr water cooler complete all as directed.
Taking out unserviceable Running capacitor and supply and fix new Running capacitor 8MFD/suitable for 40/80 or 60/120 ltr water cooler, Plastic casing , Copper wire terminal complete all as directed.
Taking out unserviceable Running capacitor and supply and fix new Running capacitor 15MFD/suitable for 40/80 or 60/120 ltr water cooler, Plastic casing , Copper wire terminal complete all as directed.
Ditto all as per item No 6 except for Starting capacitor 40/60 MFD suitable for 60/120 to 150 ltr water cooler Plastic casing , Copper wire terminal complete all as directed.
M & L for thermostat switch as in repair suitable for water cooler 40/80ltr, 60/120 to 150 Ltr complete all as directed.
S& F Thermostat suitable for water cooler of capacity 40 to 300 ltrs for 230V 50HZ AC including taking down of existing unsv one complete all as specified and directed
S& F condensing coil suitable for water cooler of capacity 40 ltr/hr to 80 ltr/hr cooling capacity as per existing including taking down existing unsv one complete all as specified and directed.
S& F condensing coil suitable for water cooler of capacity 60/120 ltr/hr cooling capacity as per existing including taking down existing unsv one complete all as specified and directed.
S& FEvaporator coil assembly for water cooler of capacity exceeding 40 ltrs and not exceeding 80 ltrs.
S& F Evaporator coil assembly for water cooler of capacity exceeding 80 ltrs and not exceeding 120 ltrs.
M&L for Brazing of copper tubing of Evaporator/ Condensing coil of water cooler of any cap all as directed.
M & L for PVC connections 15 mm size with PTMT nuts of length 900 mm long complete all as directed.
S&F in repair wire heater as per existing length and size for defreezing of blocked tubing all as directed.
M & L for Rigid Non-metalic PVC conduit 40mm dia medium grade with all fittings and fixing accessories such as coupler, lock nut, saddle, pipe hook and laid on floor (For wash out line).
S& F single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as directed.
S& F single pole and neutral enclosure with two pin and earth plug and socket complete with one double pole MCB 20 Amp complete all as directed.
M & L for stop cock 15 mm cast copper alloy, screwed down, high pressure with crutch or butterfly handle, external/internal threads,screwed both ends for GI pipe complete all as directed.
M & L for push cock as in repair chromium plated 15 mm (Inner/outer thread) of any type as directed and to suit with existing water cooler
M & L for Ball brass valve 15mm dia high Pressure with Polythene float and flynut complete screwed for iron pipe or brass ferrule, rod upto 6 " length PVC ball with all connecting items as in repair complete all as directed.
M & L for PTMP extension nipple, min weight 15mm-18 gms as in repair complete all as directed.
M & L for PTMP extension flange, min weight 15mm-5 gms as in repair complete all as directed.
Supply only Over load protector device for 120/150 Ltr Cap. Water Cooler complete all as directed.
Supply only Over load protect device for 40/80 Lts Cap. Water cooler complete all as directed.
Taking out unserviceable compressor and supply and fix compressor sealed unit type KCJ461/KCJ467/2612/KCE-443/444 suitable for 40/80 & 60/120 ltr water coolers including charging of Refrigerant if required complete all as directed.
Taking out unserviceable compressor and supply and fixing Compressor sealed unit type KCJ513/HR-13 suitable for120 or 150 ltr water coolers including charging of Refrigerant complete all as directed.
M & L for box type relay cat no 85001/02 suitable for 40/80/120/150ltr water cooler as in repair complete all as directed.
M& L for magnetic gaskets for top cover for water cooler of any capacity and make as per site requirement complete all as directed.
Supply and fix in replacment of Mild steel/Stainless steel legs with nut bolts/duly welded for water cooler of any size and make as per site requirment complete all as directed
Supply and fix in replacment Stainless steel waste water collection tray,class-1, min 1.2mm gauge, 500mm to 600mm length, 150mm width flat and arc type as per existing size suitable for with all necessary drain pipe connecting items i.e screw/nut bolt arc/gas welding reqd etc for water cooler of any capacity and make as per site requirement complete all as directed. Make ISI Marked
Supply and fix in replacement plug top 15A, 3 Pin for water cooler of any capacity and make as per site requirement complete all as directed
Supply and fix in replacement S/S Combination 2 in 1, 5A/15A, 5 pin, 1 flush type complete all as directed.
Supply & fix voltage stablizer for automatic opration. single phase naturally air cooled indoor type & designed for Input variation beetween 170V to 250 V with output voltage stablized at 230 V with accuracy of (± ) 2.5% and of capacity 4 KVA.wall mounted. Make V Guard/AE/ Voltas
M&L for sub main wiring 3x2.5 sqmm ( phase , neutral and earth) PVC insulated (heavy duty) 1100 volts grade, FRLS, with multi stranded copper conductor conforming to IS 694 in & including PVC casing caping of suitable size not less than 25mm ( 3 run of 2.5 sqmm cable and one run of PVC casing caping will be measured as one unit) including taking down of Old U/S wiring (from distribution board to metal clad switch socket point near water cooler) all as specified and directed.
Supply & fix three core 1.5 sqmm copper conductor cable lead of not less than 1.5 mtr including 5/15A plug top attached with one end and other end solenoid with thimble suitable for compressor any size.
M & L for prepartion of old painted metal surfaces of any description, with scrapping removing, dusting, and applying one coat red oxide primer and two coats synthetic animled paint as per existing existing colour with spray gun of different tint as appoved (external surface of water cooler capacity 60 to 120 ltr/ completer all as specified and directed
Supply and fix compressor suitable to fixed with outdoor unit of Carrier Make Cassete type Air conditioner of capacity 4.0TR. Make of Compressor Copeland Scroll complete all as directed.
Supply and fix electronic Sensor unit (PCB) with RC suitable for 4.0TR Casete type AC complete all as directed. Make carrier.
Supply and fix blower motor for indoor unit, single phase, 50 Hz, 220 Volts 820RPM,0.90A 6P ,suitable for Carrier Make 4.0 TR Casete type Air conditioner complete all as directed.
Supply and fix fan motor for out door unit with fan blade, single phase 230 Volts 1050 RPM, 1/6 HP,suitable for outdoor unit of Carrier Make 4.0 TR Cassete type Air conditioner complete all as directed.
Supply and fix fan blade made of HD PVC suitable for Carrier make 4.0 Ton outdoor unit including lock nut complete all as directed.
Supply and fix Air brake power contactor 3 phase AC 50 Hz 415V, 15Amps (as per existing) suitable for 4.0 TR Cassete type Air Conditioner complete all as directed.
Supply and fix water condenser drain pump assy suitable for carrier make casset type indoor unit (as per existing) complete all as directed.
Supply and fix sensor unit for water pump of carrier make casset type AC indoor unit (as per existing) complete all as directed.
Taking out existing unserviceable Street light fittings from wall/ceiling and supply and fix new LED 40 W street light fitting IP-66 with required size GI bracket and fixed on wall /ceiling with necessary MS clamps, bolts, nuts etc required for proper fixing complete all as directed.
M & L for prepartion of old painted metal surfaces of any description, with scrapping removing, dusting, and applying one coat red oxide primer and two coats synthetic enamled paint as per existing colour with spray gun of different tint as appoved (External surfaces of pipe, shell, tube type condensser any size ) complete all as specified and directed
Taking out existing unserviceable 'V' belt of compressor and supply and fix new 'V' belt Make Fenner type C-3000/ 116 or equivalent make as approved.
Taking out existing unserviceable 'V' belt of AHU blower and supply and fix new 'V' belt Make Fenner type B- 1882/LP/B70 or equivalent make as approved.
Dismantling of compressor of Central typy Air conditioner of capacity upto 55TR installed at Hubibullah Hall (Make :KIRLOSKAR , Model : AC870) and over haulling the same by replacing unserviceable / worn out parts including necessory machine work to the crank shaft, discharge valve plate etc for proper repair.Servicing of Oil pump by replacing oil pump repair kit. Reassembling the compressor unit with existing serviceable parts and new parts given here in after(as supply only), rectifying other deffects if any, Charging of Refrigerant gas (R-22) and Compressor Oil upto the required level to achive desired cooling effect, Connecting the compressor with the lines and testing commissioning complete all as directed. Notes: ii) Parts required for replacement shall be measured and paid seperately. iii) Unit rate includs retrieving existing refrigerant & Compressure oil from the plant, preserve carefully and re use the same after overhauling of Compressure. iv) Additional quantity of Refrigerant Gas & compressure oil required for the job for satisfactory running of plant shall be measured and paid seperately. v) Any Minor repair or small parts (costing up to Rs 1000/) those are not covered in item shall to be done by the contractor and rate for the same is included with the unit rate.
Cleaning of shell and tube type condenser of Central type Air conditioner 55 TR Capacity ( Installed at Hubibullah Hall ) with dilute hydrochloric acid and brushing to internal portion of condenser includin replacement of gasket,testing after cleaning complete all as directed.
Supply and incorporate Piston assy cast Aluminium including Piston rings, scraper rings & Seeger rings complete of compressor Make Kirloskar Model : AC 870 and all as directed.
Supply and incorporate Piston sleeves of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and incorporate Plunger for unloading mechanism of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and incorporate Piston pin of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and incorporate bush for Piston pin of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and incorporate Half section of bearing of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and incorporate Suction and discharge rid with valve plate of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and incorporate set of shaft seal complete of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and incorporate Gasket set complete of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and incorporate Oil heater complete of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and incorporate oil pump repair kit complete of compressor Make Kirloskar Model : AC 870 complete all as directed.
Supply and incorporate connecting rod of compressor Make Kirloskar Model : AC 870 complete all as directed.
M&L for Refrigerant Gas Leakage Testing with Nitrogen Gas Leak test including all equipememt and necessary arrengement for arresting leakage and Charging the required quantity of similar Gas as per existing refrigerant and reconfirmation of leakage removal for various cooling appliences at different places all as directed.
Supply and fill compressor oil of suitable grade POE complete all as directed
Taking out existing unserviceable 'V' belt of compressor and supply and fix new 'V' belt Make Fenner type SPC-4000 or equivalent make as approved.
Taking out existing unserviceable Pressure control device and supply and fix new Pressure control device(High pressure cut off with indicator) type MP-5 complete all as directed.
Taking out existing unserviceable Pressure control device and supply and fix new Pressure control device (low pressure cut off with indicator) type MP-1, complete all as directed.
Taking out existing unserviceable Pressure control device and supply and fix new Pressure control device(High pressure cut off with indicator) type MP-15 complete all as directed.
Taking out existing unserviceable Oil Pressure control device and supply and fix new Oil Pressure control device (Oil pressure cut off with indicator) type MP-35 complete all as directed.
Taking out existing unserviceable Oil Pressure control device and supply and fix new Oil Pressure control device (Oil pressure cut off with indicator) type MP-55 complete all as directed.
Taking out existing unserviceable Loading/unpoading soloniod Valve three way 1/4BSP, 22 bar pressure, 100 degree C, 230 Volt and supply and fix new Loading/unpoading soloniod Valve three way 1/4BSP, 22 bar pressure, 100 degree C, 230 Volt complete all as directed. Make Danfoss /Indfoss
Taking out existing unserviceable High Pressure gauge and supply and fix new high Pressure gauge 0-25 Kg/cm square as per existing size complete all as directed.
Taking out existing unserviceable Low Pressure gauge and supply and fix new Low Pressure compound gauge 0-16/0-(-760) Kg/cm square suitable for R-22 as per existing size complete all as directed.
Taking out existing unserviceable monometer gauge and supply and fix new Monometer water suction gauge 0-10.6 Kg/cm square as per existing size complete all as directed.
Taking out existing unserviceable monometer gauge and supply and fix new Monometer water Discharge gauge 0-21 Kg/cm square as per existing size complete all as directed.
Taking out existing unserviceable water pressure switch and supply and fix new water pressure switch (IPS) for oil air water stem as per existing size complete all as directed.
Taking out existing unserviceable liquid soloniod valve and supply and fix new liquid solenoid valve/pilot solenoid valve MAG-2, 208-240V, 50-60 Cy, 15W as per existing size complete all as directed.
Taking out existing unserviceable filter dryer 1/4 inch outer thread, C-032Fand fix of new filter dryer 1/4 inch outer thread, C-032F as per existing size complete all as directed.
Dismentiling carefully all water connections, decoping of pumps from electric motor taking out from foundation and transporting pump body to workshop for necessary machining works as directed and reqd and reinstalling the pump to its original position and commissioning etc instaled at Habbibullah hall/ATT Plant for diffrent capacity
Repair and rewinding of electric induction motor by using super enamelled copper wire (Class-F) as per existing gauge, heating and varnishing complete. The repair work involves taking out burntout winding coiles from stator, cleaning of slots throughly , removing all dirt grease an other unwanted particle, replacmement of UNSV parts where reqd (as directed) capacity of motor 75/50 HP complete all as direced NOTE : (i) Unit rate is deem to be included for taking out otor from its position, shifting of motor from pump housed to workshop, getting back to plant house, reinstalling at site, connecting up, couple with the pump and testing complete, retrieved windg wire will be the contractors property and necessary credit amount is deemed to be included in the quoted rate, hence no credit has been considered in credit schedule. (ii) Spare parts other than rewinding job required for replacment shall be measured and paid speeratly as supply only.
Repair and rewinding of electric induction motor by using super enamelled copper wire (Class-F) as per existing gauge, heating and varnishing complete. The repair work involves taking out burntout winding coiles from stator, cleaning of slots throughly , removing all dirt grease an other unwanted particle, replacmement of UNSV parts where reqd (as directed) capacity of motor 20/15/10 HP complete all as direced. NOTE : (i) Unit rate is deem to be included for taking out otor from its position, shifting of motor from pump housed to workshop, getting back to plant house, reinstalling at site, connecting up, couple with the pump and testing complete, retrieved windg wire will be the contractors property and necessary credit amount is deemed to be included in the quoted rate, hence no credit has been considered in credit schedule. (ii) Spare parts other than rewinding job required for replacment shall be measured and paid speeratly as supply only.
Dismantling/opening the pump part by part without damaging any other parts , descaling and cleaning of all parts for inspection and finding serviceability/unserviceability of the parts and carefully assembling of pumps by using existing serviceable parts including replament of gasket packing greasing all bearings, bushing,etc and replaement of unserviceable parts as directed installed at Habbiullah Hall/ATT Plant 10/15/20 HP ( Cooling water pump/ Blower motor of AC plant ), thoroughly, complete refix at their existing position reinstall the pumpr at existing position, complete all electric connections and testing complete all as directed. .
Preventive maintenanc of AC, 3 Phase induction motor of capacity 20/15 HP by dismantiling the motor completely without damaging any parts and applying air dry insulating varnish, of appropriate grade (make doctor bake/appex), cleaning bearing refix at their existing position with bearing grease, checking terminals and thimbles tighting the all terminal joints replace terminal plates where necessary/reinstall the motor at existing position, connecting electric connections and testing complete all as directed.
Preventive maintenanc of AC, 3 Phase induction motor of capacity 7.5/10 HP by dismantiling the motor completely without damaging any parts and applying air dry insulating varnish, of appropriate grade (make doctor bake/appex), cleaning bearing refix at their existing position with bearing grease, checking terminals and thimbles tighting the all terminal joints replace terminal plates where necessary/reinstall the motor at existing position, connecting electric connections and testing complete all as directed.
Taking out existing burnt contactor from panel and Supply,fix and connecting 3 Pole power contactor, 415 Volt, AC 3 Phase,AC3 rating 45 Amps, AC 3 Phase, AC1 rating 50 Amps, with 400/230 Volt coil,(as per existing ) Make L&T / Telemecaniqee /C &S/BCH/Schneider.( Power contactors may be of different make as fitted in existing pannel so that the contactors can be accommodated in its position) complete all as directed.
Taking out existing burnt contactor from panel and Supply,fix and connecting 3 Pole power contactor, 415 Volt, AC 3 Phase, AC3 rating 18 Amps AC1 rating 20 to 32 Amps, with 400/230 Volt coil,(as per existing ) Make L&T / Telemecaniqee /C &S/BCH/Schneider.( Power contactors may be of different make as fitted in existing pannel so that the contactors can be accommodated in its position) complete all as directed.
Taking out existing Thermal over load relay and supply and fixing of new relay type AUR1 make Schneider or equivalent of L&T/C & S/ / L & T/BCH/ Schneider/Telemecaniqee.( Relays may be of different make as fitted in existing pannel so that the relays can be accommodated in its position) complete all as directed.
Taking out existing burnt Add on auxilary contact block from panel and Supply,fix and connecting new Add on auxilary contact block with 2 NO + 2NC, front mounted ,415 Volt, Make C & S / L & T/BCH/ Telemecaniqee/schneider.( Add on block may be of different make as fitted in existing so that theblocks can be accommodated in its position) complete all as directed.
Taking out existing burnt timer from panel and Supply,fix new Timer 0-30/60Sec pluse time 50-100 msec, 800 SD 2-230 selce,415 Volt, reqd for star delta Make L & T, C & S / BCH/ Telemecaniqee/schneider.(Timer may be of different make as fitted in existing so that the timer can be accommodated in its position) complete all as directed.
Supply and fix in replacment of of Miniature circuit breaker tripple pole 415 volt, 25-63 Amps having rupturing capacity 10kA 'C' Series complete all as directed.
Cleaning of cooling coil fins and filters complete of AHU of 55 TR capacity installed Habibullah hall by caustic soda and Nylon brush as per direction and refix at their existing position
M&L for servicing the Air handling units capacity 40/55 TR, with and including cleaning complete units, sheet metal parts, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent Vaniklin at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connection, cleaning of air filters,prefilters & fine filters box type with washable nylon filters media having 90% efficiency to control dust particles up to 10 microns fitted in aluminum framed with both side wire mesh of size 610x610x50mm of class EU-4 and for fine filters 99% efficiency to control dust particles up to 10 microns 610x610x500 mm EU-7 as per sample suitable for 55 TR AHU plant,greasing of blower motor,replacement of unserviceable bearings, water drain lines, renewal of rusted sheet metal screws, and testing & commissioning the unit all as specified and as directed
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) connected to galvanized Iron strip 25x 4mm by means of bolts, nuts and washers of galvanized iron or steel, GI light grade protection pipe 15mm dia, GI medium grade water pipe 20mm dia with funnel all as shown in electric plate No 3 of SSR-2020 pt-I and testing complete including earth work excavation in any type of strata /soil PCC 1:2:4 as in earthing pit, 50 mm PCC pit cover with 6mm iron handle attached , common salt charcoal all as specified including testing on complete. Note : GI Strip beyond 7.5 mtr shall be measured and paid for sperately.
M&L for Duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 25 mm as specified and including the following:- (a) Cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Applying rubber based adhesive CPRX compound. (c) Sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) Securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
M&L for disconnecting electrical connections 5 HP motor located at the top of cooling tower and dismantling and taking out fan blade assembly along with motor mounted on base frame at the top of cooling tower after cutting all nuts, bolts and fixtures from the mounting frame and removing whole assembly including motor and base frame from the top of cooling tower with the help of T&P for servicing of cooling tower suitable for 40 TR capacity including following complete for servicing cooling tower plant through cleaning re-agent complete pipe line, including servicing of cooling tower motor and fan and make the necessary alignment with motor and replacement of bearing of suitable cap after necessary work including greasing and replacement of nut bolts and preventing leakage and balancing the cooling tower with all suitable legs if any by means of suitable additives etc all as directed and specified. (a) Cleaning /scrapping of inner& outer surface of FRP basin, repair of damaged portion if any to and for FRP lining of all surfaces joints to avoid leakage including replacement of all nuts and bolts joining all parts of Basin complete (b) cleaning of serviceable PVC fills(Big size ) in columns of size 60x30x15 cm (c) Cleaning of serviceable PVC fills(small size ) in comb of size 60x15x15 cm
M&L for preparation of old painted surfaces of AC plant cooling water pump/condenser water pump sets up to 10 HP including base frame and condenser water pipe line from condenser to cooling tower including cooling tower frame by scrapping and removing rust, accumulated grease/dust etc and applying two coats of synthetic enamel paint over a coat of zinc chrome primer on rusted portion and marking machine numbers all as directed for central AC plant,.
S&F Pre-filter made up of GI sheet frame size 65x 25cm with Nylon wire mesh 10 Micron grade with efficiency more than 90% suitable of AHU of 55TR Cap Central AC Plant
Dismantling and taking out serviceable/ unservicable split type airconditioning machine carefully complete of capacity 1.5 TR/2.0 TR with outdoor unit, indoor unit, copper pipes, cables etc and depositing AC unit to MES store for repair and reinstall at site after carring out necesary repair work.
Supply & Install Hi wall Split AC unit with invertor compressor 1.5 TR indoor/ outdoor unit complete, complete with cordless remote controlunit and with in built air ioniser and plasma filtrer for better air quality with minimum 5 star rating, duel compressor invertor single phase including additional copper tubing with insulation,MS Bracket for Outdoor Unit and extra copper tubing with insulation and Drain out flexible pipe of lenght as per sit requirement including all necessary fixing arrengementall as directed. Make: LG Model LG A/CLS-Q18SWZA or equivalent in Voltas/ Hitachi/ Carrier
Supply & Install Hi wall Split AC unit with invertor compressor 2 TR indoor/ outdoor unit complete, complete with cordless remote controlunit and with in built air ioniser and plasma filtrer for better air quality with minimum 3 star rating, duel compressor invertor single phase including additional copper tubing with insulation,MS Bracket for Outdoor Unit and extra copper tubing with insulation and Drain out flexible pipe of lenght as per sit requirement including all necessary fixing arrengementall as directed. Make: LG Model LG KS Q24ENXA or equivalent in Voltas/ Hitachi/ Carrier Note : Above item incorporated as per Para 9a(III) of DWP2020 as Orinary repair.
M & L for making holes by core cutting machine on stone/concrete / brick walls.Dia of hole not exc.50mm and thickness of wall 50cm to 70cm for entry of suction and discharge pipes of AC and making good distarbed surfaces with cement morted and finally finished with plaster of parise and painted the distrubed surfaces with existing type of paint and tint complete all as directed.
Supply & fix in replacement of Starting capacitor of 80-100 Mfd, AL Casing, Copper wire terminal suitable for 1.5 TR split AC,
Supply & fix in replacement of Starting capacitor of 100-120 Mfd, AL Casing, Copper wire terminal suitable for 2.0 TR split AC,
Supply & fix in replacement of rotary compressor suitable for 3.0 Ton split Air conditioner 3 phase, 415 volt and fixed in out door unit complete all as specified and as directed. Note : Make of compressor Toshiba/Emerson/ Kirloskar copland/Hitachi.
Supply & fix in replacement of compressor suitable for 2.0 Ton split Air conditioner working on R-22/R410/R404 refrigerant, single phase, 230 volt and fixed in out door unit complete all as specified and as directed.Make of compressor Toshiba/Emerson/ Kirloskar copland/Hitachi.
Supply & fix in replacement of rotary compressor suitable for 1.5 Ton split Air conditioner working on R-22/R410/R404 refrigerant, single phase, 230 volt and fixed in out door unit complete all as specified and as directed. Note :Make of compressor Toshiba/Emerson/ Kirloskar copland/Hitachi.
Supply & fix in replacement four pole power contactor 25Amps, with standard coil voltage suitable for 3.0TR split Air conditioner complete all as directed.Make L&T type MCX 02 or equivalent make of C&S, Legrand, BCH, Siemens.
Supply & fix in replacement single pole contactor Type MR 25 Amps, with coil voltage 230 volts for spilt type AC 1.5/2.0 TR complete all as directed. Make L & T type MR11NW or equivalent of C&S, Legrand, BCH, Siemens.
Supply & fix in replacement electronic auto sensor unit (PC card with all component) suitable for AC/DC Supply of make LG/Sumsung/Carrier /Bluestar Make for Split AC 2.0/1.5/3.0 Ton capacity complete all as directed.
Supply & fix in replacement air blower motor with shaft suitable for indoor unit of 1.5 TR split type AC of any approved make (as per existing make of AC) complete all as directed.
Supply & fix in replacement air blower motor with shaft suitable for indoor unit of 2.0 TR split type AC of any approved make (as per existing make of AC) complete all as directed.
Supply & fix in replacement fan motor with fan blade suitable for outdoor unit of 1.5 TR split type AC of any approved make (as per existing make of AC) complete all as directed.
Supply & fix in replacement fan motor with fan blade suitable for outdoor unit of 2.0 TR split type AC of any approved make (as per existing make of AC) complete all as directed.
Supply & fix in replacement copper tube of suction line of split AC 1.5/2.0/3.0 OTR 5/8" dia including necessaring flearing/soldering and provn of flair nut for jointing complete all as directed
Supply & fix in replacement copper tube of suction line of split AC 1/4" dia including necessaring flearing/soldering and provn of flair nut for jointing complete all as directed.
M & L for providing insulation of copper pipes of split AC with 19 mm thick nitrile foam insulation tube and finally wraping with heatlon taps, binding with PVC tag complete all as directed.
Supply & fix in replacement of Runing capacitor 45/4 Mfd, AL Casing, Lug terminal 440 volt, 50Hz for split or window type AC of capacity 2.0TR. Make :Havells/Universal/Usha/Epcos
Supply & fix in replacement of Runing capacitor 36/4 Mfd , AL Casing, Lug terminal 440 volt, 50Hz for split or window type AC of capacity 1.5TR. Make :Havells/Universal/Usha/Epcos
Supply & fix in replacement of box type relay suitable for window type AC. Make SRIRAM Model SR 1622 or Emerson.
Supply & fix in replacement thermostat suitable for window type AC 1.5/2.0 TR complete all as directed.
S&F PVC Insulated FR, PVC Round Sheathed, copper conductor flexible cable ,2.5 sqmm ,3 core, multi stranded, 1100V grade, conforming to IS 694 all as specified and directed
Supply & fix in replacement of universal/Strainer filter cum dryier suitable for 1.5/2.0 TR AC/Water cooler/Refrigerator.
Supply & fix in replacement of universal/Strainer filter cum dryier dcl 304 suitable for 3/4TR AC Cold Room
Supply & fix in replacement blower motor with blade, single phase, 230V 1500 RPM, 1/5 HP, Suitable for 1.5/2.0 TR window type Air conditioner.
Supply & fix in replacement of capacitor 4 MFD,Plastic casing , Copper wire terminal 230 volt, 50 Hz
Supply & fix in replacement electronic sensor unit (PCB) suitable for 1.5/2.0 TR window AC of any make as ordered.
Supply & fix of in replacement compressor hermetical sealed reciprocating type suitable for 1.5 Ton AC.Make of compressor Toshiba/Emerson/ Kirloskar copland/Hitachi.
Supply & fix in replacement of compressor hermetical sealed reciprocating type suitable for 2.0 Ton AC.Make of compressor Toshiba/Emerson/ Kirloskar copland/Hitachi.
Supply only thermostat suitable for 1.5 T/2T for Window AC suitable capacity for 230 V 50 HZ AC supply all as directed.
Supply only for cooling coil made out of copper tube of size as per existing coil capacity and specification suitable for 1.5 T/2T window AC of any make and type as per existing complete all as directed
Supply only Remote control for AC as per sample of any make ,type capacity all as specified and directed
M &L for taking out split AC indoor/outdoor unit complete with copper tubing of any type size and make for shifting at other place after making necessary opening in existing wall any type /thickness and fixing of AC with cooper tubing and drain out pipline after necessary servicing complete all as specified and directed. Note:Transportation of AC is included in this quoted rate
S&F for flexible pipe 40mm dia heavy duty from oudoor unit to indoor unit including taking down of old unsv complete all as specified and directed
Supply & fix in replacement compressor suitable for 310/320 ltr Refrigerators complete all as directed. Make of compressor Toshiba/Emerson/ Kirloskar copland/Hitachi.
Supply & fix in replacement compressor suitable for 190/215/220 ltr Refrigerators complete all as directed. Make of compressor Toshiba/Emerson/ Kirloskar copland/Hitachi.
Supply & fix in replacement of thermostat suitable for refrigerator of any capacity up to 320 ltr. Make: INDFOS/RENUTRAL/DENFOSS
Supply & fix in replacement Relay suitable for Sumsung / Godrej/ LG/ Voltas make refrigerator as directedand to match as per existing refrigerator complete all as directed.
Supply & fix in replacement of defrost timer for refrigerator of capacity 215 /310/320 Ltr to match as per existing refrigerator.) complete all as directed.
Supply & fix in replacement of bimetal contactor for refrigerator of capacity 215/310/320 Ltr to match as per existing refrigerator complete all as directed.
Supply & fix in replacement of magnatic gasket for door suitable for Refrigerator of any type and capacity complete all as directed.
S& F chiller door of approved brand for refrigerator of any make and type capacity 165/180 ltrs as ordered and suitable for fitted with existing cooling chamber of refrigerator including taking down of existing unsv one as specified and directed
S& Fchiller door of approved brand for refrigerator of any make and type capacity 220/250/310 ltrs as ordered and suitable for fitted with existing cooling chamber of refrigerator including taking down of existing unsv one as specified and directed
S&F for chiller tray of approved quality brand suitable for 165/180/220/310/320 ltrs capacity refrigerator including taking down of existing unsv one as specified and directed
S&Fin repairs pvc try for vegitable/fruits of approved quality brand suitable for 165/180/220/310/320 ltrs capacity refrigerator including taking down of existing unsv one as specified and directed
Supply & fix in replacement compressor sealed unit including relay suitable for 325/200 Ltrs Deep freezears complete all as directed.Make of compressor Toshiba/Emerson/ Kirloskar copland/Hitachi.
Supply & fix in replacement of thermostat suitable for Deep Freeze of any capacity suitable to set with the existing compressor complete all as directed.
Supply & fix in replacement of blower motor with blade, single phase, 230v 50 Hz, RPM-1325 suitable for deep freezer
S& F in replacement of voltage stabilizer for automatic operation,Copper wound, single phase naturally air cooled indoor type, ISO certified & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA Make one of the following : Bluestar/V-Guard/ Brent Ford/ Vinitec/ Automatic Electric.
S&F only Over load protector device suitable for existing deep freezer as specified and directed
S&F only relay device suitable for 325/200 Ltrs Deep freezer as specified and directed
S& F in replacement including connection 3 pole AC power contactor, AC1 Rating 32 Amps nd AC 3 rating 18A, 415 Volt with auxilary contact 1NO + 1NC, having coil voltage 380 to 400 Volts complete all as directed. Make Simens cat No C4NE22 or equivalent
S& F in replacement of connecting Intigrated circuit board with all electronic components suitable for 8.5 TR capacity Carrier Pakage type Air conditioner complete all as directed.
S& F in replacement of connecting high pressure cut off valve 275 lbs suitable for 8.5TR capacity package AC of make Carrier complete all as directed.
S& F in repairs connecting low pressure cut off valve 25 lbs suitable for 8.5TR capacity package AC of make Carrier complete all as directed.
S& F in repairs connecting SPPR Circuit board suitable for 8.5TR capacity Package type AC complete all as directed Make Carrier.
Supply & fix in replacement of only electronic sensor unit (PCB) suitable for 8.5 TR Package type AC of any make as ordered.
Servicing & maintenance (as and when directed) of Cold room/walk -in-freezer out door/indoor unit outer and inner side cleaning of condensing unit/all filters, dryears complete with vaccume clenear, soap water, castic soda, colin etc of any capacity of any make in situ including, leak testing, brazing the suction / discharge tubes checking electric connection from DBs to machine , sensor unit/cooling effect of airconditioner etc any time during period of the contract for proper functioning complete all as specified and as directed.
Taking out unserviceable circuit board and supply and fix new electronic circuit board (PCB Kit) for walk -in - cooler/walk -in- freezer suitable for Carrier / Blue Star make unit, fixinx and connecting to existing system complete all as directed.
Taking out unserviceable defrosting timer and supply and fix new defrosting timer with sensor suitable for 3/4Ton AC , cold room 40Amps rating suitable for Carrier / Blue Star make Walk-in-cooler/freezer including connecting complete all as directed. Make : SubZero or equivalent.
Taking out burnt power contactor from the panels and supply, fix new 3 pole, 415 Volt power contactor with NO & NCs and AC3 current rating 12 Amps complete all as directed. Make L&T, type MNX 12. Cat Ref CS94108/ CS94109 or equivalent.make of ABB/GE power.
Ditto all as per item No 162 above but AC3 current rating 18 Amps complete all as directed make L&T, type MNX 18. Cat Ref CS94100/CS94101 or equivalent make of ABB/GE power.
Ditto all as per item No 162 above but AC current rating 22 Amps complete all as directed make L&T, type MNX 22. Cat Ref CS94980/CS94981 or equivalent make of ABB/GE power.
Ditto all as per item No 162 above but AC3bcurrent rating 25 Amps complete all as directed make L&T, type MNX 25. Cat Ref CS94110/CS94111 or equivalent make of ABB/GE power.
Taking out burnt power contactor from the panels and supply, fix & connecting new 3 pole, 415 Volt power contactor of AC3 current rating 25 Amps, 2 NO + 2NC complete all as directed make L&T, type ML 1.5, equivalent make of ABB/GE power.
Taking out burnt Single Phase Prevntor from the panels and supply, fix new Single Phase Prevntor Relay (Type SDz5 415V) and testing complete all as directed.
Taking out unserviceable solenoid valve of cold room and supply, fix new solenoid valve as per existing type complete all as directed. Make Danfoss / Indfoss.
Disconnecting and taking out unserviceable fan motor of evaporator with blade and supply and fix new eveporator fan motor with blade as per existing sweep and r.p.m, single phase, 230 volts, 1/2HP including necessary adjustment, fixing and connecing complete all as directed. Make :GE/UNIVERSAL/BLUESTAR/ POPULAR
Disconnecting and taking out unserviceable fan motor with blade of any sweep and make fixed in out door unit of Cold room and supply and fix new fan motor as per existing sweep and r.p.m, single phase, 230 volts, 1/5HP including necessary adjustment, fixing and connecing complete all as directed.
S&F Strip heater not less than 6-8 mtr length for cold Room Door as per existing specication and as direted.
Taking out existing unserviceable door locks of cold room and supply and fix new door locks along with all fittings and fixing accessories as per the existing to suit with the ystem complete all as directed.
Taking out burnt connector blocks from machine and supply and fix connector block 32 Amps rated with 4 terminals and connecting complete with replacement of cable lugs. (connector blocks made of bakelite/epoxy).complete all as directed.
Taking out existing damagad magnetic gasket for door of walk-in-cooler/walk-in-freezer and supply and fixing new rubber gasket of suitable size and fixed on doors/frames with fixing media to make cold room leak proof.
Supply and fixing SS-304 equal angle of size 25mm x 25mm x 3mm, fixing with door frame of cold room by means of counter shunk screw/rivets as directed to make good the deshaped door frame including taking out damaged angles from the frame.
supply and fix temprature indicating unit in automatically defrosting control monitor sensor display suitable for any type and any capacity for different cold room (as per existing make of Cold room)
Taking down burnt compressor from its position and supply, install, conecting and testing of hermetically sealed compressure of capacity 3.5 HP, suitable for R-22 refrigerant, AC 3 phase, 415 volt, 50 Hz, having capacity of cooling 4 C suitable for cold room Make of compressor Toshiba/Emerson/ Kirloskar
Taking down burnt compressor from its position and supply, install, conecting and testing of hermetically sealed compressure of capacity 3 HP, suitable for R-404/410 A refrigerant, AC 230/415 volt, 50 Hz, having capacity of cooling (-) 22 C suitable for walk -in-freezer Make of compressor Toshiba/Emerson/ Kirloskar copland/Hitachi.
S&F in replacement SS-304 Strip of size 150mm and thickness not less than 3mm as per exixting specication and as directed.
Servicing & maintenance (as and when directed) of Child water storage unit outer and inner side cleaning of condensing unit/all filters, dryears complete with vaccume clenear, soap water, castic soda, colin etc of capacity 4.5 HP of any make and any type in situ including, leak testing, brazing the suction / discharge tubes checking electric connection from DBs to machine , sensor unit/cooling effect of airconditioner etc any time during period of the contract for proper functioning complete all as specified and as directed.
Taking down burnt compressor from chilled water plant and supply, install connecting and testing of hermetically sealed compressure of capacity 4.5 HP, suitable for R-22 refrigerant, AC 3 phase, 415 volt, 50 Hz, having capacity of cooling 4 C suitable for chilled water plant installed at cadet mess.
Supply and fix in replacement of solenoid valve- Type HM2
Supply and fix in replacement of relay -Type LR1-D12316
Supply and fix in replacement of temperature indicator sub-O SZ 7510P
Supply and fix in replacement of temperature indicator sub-T-72
Supply and fix in replacement of relay MNX-12 Make Castle/Danfos/Indfos
Supply and fix in replacement of relay MNX-A18 Make Castle/Danfos/Indfos
Servicing & maintenance (as and when directed) of Ice making/Ice Cube machine unit outer and inner side cleaning of condensing unit/all filters, dryears complete with vaccume clenear, soap water, castic soda, colin etc of any make and any type in situ including, leak testing, brazing the suction / discharge tubes checking electric connection from DBs to machine , sensor unit/cooling effect of airconditioner etc any time during period of the contract for proper functioning complete all as specified and as directed.
Supply & Fix in replacement of solenoid valve suitable for ice making machine of make as per existing ice machine/super refrigerator Co Ltd
Supply & Fix in replacement of fan motor of condensing unit suitable for ice making machine of 1/5 hp of make as per existing ice machine/super refrigerator co Ltd.
S& Fix in replacement of Compressor sealed unit of capacity 1 TR suitable for ice making machine of cap 10 ltr hr of make as per existing ice machine/super refrigerator co Ltd.
Supply & charging refrigerant gas R-410 to cooling appliances/cooling equipments complete all as directed
Supply & charging refrigerant gas R-134 (a) to cooling appliances/cooling equipments complete all as directed.
Supply & charging refrigerant gas R-404 (a) to cooling appliances/cooling equipments complete all as directed.
Supply & charging refrigerant gas R-22 to cooling appliances/cooling equipments complete all as directed.
Taking down old unserviceable PUF Panel/slab insulation, PUF panel and S& FPUF Panel/slab insulation, PUF panel cladded with 0.45mm thickness SS sheet both side, 40 kg/cum PUF density for wall, ceiling 120mm thickness panel including all connecting accessories i.e flashing, silicon, liquid puf, revets etc as per directed.
Taking down old unserviceable PUF Panel/slab insulation, PUF panel and S& Ffreezer room PUF Panel/slab insulation, PUF panel cladded with 0.45mm thickness SS sheet both side, 40 kg/cum PUF density for floor slab 100mm thickness panel including all connecting accessories i.e flashing, silicon, liquid puf, revets etc as per directed.
S& F swing type insulated door 900(W)x2000(H)x120 (thikness) mm incl frame of required size PUF insulated Panel cladded with both side SS Sheet, complete with strip heater of not less than 6mtr, kick plate and all acessories i.e locks, hinges, recets etc complete all as per directed
Servicing/ maintenance (as and directed) of Air cooler/Desert cooler of any capacity type disconnected form water/electric connection and carry out to EM Store and after servicing and testing install the other location as per direction. Note :Daily maint complaints in wirting given/handed over by this office shall be attend and rectified by the rep detailed by the contractor. The rate deem to be included in quoted rate. No extra claim on all this shall be entertained.
Supply & Fix in replacement of submersible pump suitable for 4000 cfm air cooler vertical/horizontal type as required at site. Make Bajaj/Livia/Orizon/Popular
Supply & Fix in replacement of fan blade suitable for plastic body air cooler.
Supply & Fix in replacement of fan motor single shaft of air cooler having 105 watt out put, 1450 r.p.m, operating on 230 v AC
M & L for fan motor1/8 hp double shaft type suitable for air cooler, operating on 230 V AC supply
Supply only capacitor 4 mfd Pastic casing Lug terminal complete all as specified and directed .
M&L for Sub main wiring two single core PVC insulated unsheathed cable 1100 volts grade, FRLSH, 4 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit including PVC insulated unsheathed FRLSH 4 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed.
SUNIT TRADING CORPORATION
Tejas Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .