| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.0 L+₹51,707.50 (2.53%)Rejected-AOC 728 1 JOGIWARA VISHAVKARMA MANDIR ROAD AMBALA CITY | AMBALA CITY | AMBALA | HARYANA | 134003 | L2 | Rejected-AOC L2 |
Tender Value
₹21.0 L
EMD Value
₹41,960
Closing Date
24 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Hakimpet
Secunderabad
PROVISION OF CERTAIN MAJOR REVENUE AND MINOR WORKS AT AFS HAKIMPET UNDER GE (AF) HAKIMPET
2022_MES_559966_1
8450/E8
Open Tender
Civil Works
Item Rate
180 days
Hakimpet
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) HAKIMPET
₹41,960
Yes
28 Jan 2023
27 Oct 2022
26 Nov 2022
27 Oct 2022
24 Nov 2022
10 Nov 2022
Amount
Surface excavation n. exc 30cm deep and averaging 15cm deep and getting out in any type of soil.
Demolition of cement concrete in ground floor including tile, terrazo tile and paving n exc 15cm thickness(below or above ground level) unreinforced concrete and removed debris outside MD land.
M & L Hardcore of gauge exc. 63mm, deposited, spread and levelled in layers n. exc 15cm thick, watered and rammed to a true surface complete all as specified.
M&L 100 mm thick Cement concrete type C-2 1:3:6 using 40mm graded stone aggregate as in sub base all as specified and directed.
M&L sand filling under floor all as specified and directed.
M&L Machine pressed precast conctete interlocking paver block with colour pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 all as specified and directed.
M& L Providing, cement concrete in kerbs or mud stops, rounded 1 :2:4 type B1 using 20mm graded stone aggregate including form work as required finished sufaces even and smooth complete all as specified and directed.
Supply and fix sheet glass, ordinary quality, 4 mm thick, in squares not exc 0.50 Sqm in each pane and glazing with oil putty complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement plaster on brick or stone walls/ceilings etc including raking out joints , hacking for key and scrubbing down with water etc., and removed debris outside MD land complete all as specified and directed.
M&L for rendering 15mm thick in CM(1:4) on fair faces of brickwork or concrete surfaces finished fair and even all as specified and as directed.
Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings at max hight of 10.0m complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified.
Dismantling of stone slabs of any description or thickness in floors and approns etc, laid ,bedded and pointed in any mortar all as specified and directed.
M & L 20 mm thick Granite (of any type) tiles machine cut, bedded over cement screed bed 15 mm thick in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
Rounding to edge of stone slab one edge, such on in stop, cooking plateform, and other similar situation complete all as specified and directed.
Complete removal of existing treatment from walls including scrapping and removing the entire scales of existing treatment complete all as directed.
M&L for applying two coats of OBD including preparation on wall surfaces over and including 3 mm thick wall putty on wall surfaces complete all as specified and directed.
M &L rendering 10 mm thick in CM 1:3 on celling surface, finished even and smooth with out using extra cement all as specified and directed.
M & L preparing old surfaces, including cornices and applying two coat of white wash on celling all as speicified and directed.
Excavation in post holes each n.exc 0.50 cum getting out. Returning filling in layers n.exc 25cm etc removal at surplus soil to a distance n.exc 50 mt and making good surface in any type of soil.
M&L Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) laid in base, mass concrete all as specified and directed by Engineer In charge.
M&L for 75mm thick PCC type D-2, 1:4:8 (40mm graded stone aggregate) laid in sub base finish cement concrete surface fair and even.
M&L for providing cement concrete 1:2:4 type D2(using 20mm graded aggregate) as in foors and pavings as specified and directed.
Form work to sides of concrete footings plinth beams and similar work etc with rough finished surfaces all as specified.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F Steel work as in tubular trusses including special shaped washers etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St 240 complete all as specified.
Proving and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line,level and curvature,jointed with cement mortar 1:3(1 cement :3 course sand) including making joints with or without grooves(thickness of joints except at sharp curve shall not more than 5mm) including making drainage opening wherever required complete all as specified.
Taking down chowkats or frames exc. 1.5 Sq mtr and not exc 4.0 Sqm each with shutters without taking off shutters from the frames complete all as specified and as directed by the Engineer-in-Charge
S&F Factory made UPVC fully sound proof windows/doors including frames/choukats,shutters,powder coated with 19mm thick DGU(Double glazed unit) glass with all fittings and fixtures and locking arrangements including spacer,drying agent and sealents complete all as specified and as specified.
M &L 40 mm thick PCC (1:2:4 ) type B0 using 12.50 mm graded stone aggregate as in floor finished even and smooth complete all as specified and directed.
M &L 75 mm thick PCC (1:2:4 ) type B1 using 20 mm graded stone aggregate as in floor finished even and smooth complete all as specified and directed.
M &L 150 mm thick PCC (1:2:4 ) type B1 using 20 mm graded stone aggregate as in floor finished even and smooth complete all as specified and directed.
M & L 20 mm thick Granite (of any type ) tiles machine cut,fixing in skirting dado or risers,jointed with grey cement slurry mixed with pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed
M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 is to be finished even and smooth (with out using extra cement) complete all as directed
M&L for applying two coats of distemper oil emulsion over a coat of primer on newly plastered surface of wall all as directed.
Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-In-Charge
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc.complete all as specified
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in deep and getting out in hard/dense soil for foundation of culvert.
M&L for RCC 1:2:4 type B-1 (using 20mm graded aggregate) asin retaining wall,drains and the like of any thickness complete all as specified and as directed
Framed work such as grills and gratings etc with end bars shouldered and or reveted conforming Fe-290 Grade E-165 including necessary weldings and achorage in to concrete complete all as specified and as directed
S&F mild steel plates(chequered or plain) 5mm thick or over in thickness FE-410W(Gde E-250)quality A including cutting,welding,drilling etc complete all as specified and as directed.
S&F mild steel round bars 10mm dia and over as in cover handle including necessary cutting and welding of Fe-290(Gde E-165) complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm
Removing excavated material exc. 1.5 m but n.exc 5km and depositing where directed
M&L for Preparing new steel and iron surfaces of any description over 10 cm widthor girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
Taking down existing unserviceable point wiring of any description/type/ size of light/ fan/tube/power/two way/bell point etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
M & L for Point wiring on surface conduit with 1.5 Sq mm copper conductor single core PVC insulated FRLS 1100 V multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 1.6 mm thick MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated hylam sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc all as specified and directed for
(a) One light point controlled by one, one way switch 5A, SP
(b) One ceiling fan/Exhaust fan point controlled by one, one way switch and regulator
(c) One 2/3 pin 5 Amps socket outlet point controlled by one switch on the same board
(d) One 3 Pin 5 Amps switch socket Independent board
(e) one Bell point controlled by one Bell Push
All as per ser item here-in-before but for one 16 Amps switch socket combination on independent board with 4 sqmm FRLS cables for phase and neutral and 4 sqmm FRLS cable green in colour as earth continuity conductor.
Supply and fix switch piano flush type 5 Amps, one way complete all as specified and directed.
Supply and fix Bell push, flush type, 5 amp , complete all as specified and directed.
Supply and fixing socket outlet 2/3 pin (5 pin) multi purpose 5 Amp flush type.
Supply and fix Switch socket combination 2 in 1, 3 pin, 5 Amps flush type universal complete all as specified and directed.
Supply and fix Switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified.
Supply and fix Ding Dong Bell suitable for working on 230 Volts 50 HZ Supply
Supply an fix stepped type electronic regulator for ceiling fan flush type suitable for 230V 50Hz Ac Supply complete all as specified and directed by engineer in charge
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer in charge
Supply and fix ceiling fan with three blades (White colour), 1200mm sweep with down rod and canopy (5 star rating) suitable for running on 230V 50 Hz Ac complete all as Specified and directed by Engr In Charge.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by engineer in charge
Removing and refixing the same, disconnecting the 2X2 Fitting/LED batten 20 Watts/Led Batten 10 Watts/Round Panel/20 Watt Box type fitting with tube and fixtures from its original position for rewiring and again refixing after rewiring on original position with necessary wire complete all as specified and as directed by engineer in charge
Taking Down of old SPN DB 8 way with MCBs and rewiring of DB with suitable size of wire all as specified and as directed by Engineer in Charge
Supply and fix heavy duty exhaust fan Copper wound with metal body, metal frame & metal blades of size 300mm sweep, 1200 RPM suitable for working on single phase, 230 volts, 50 Hz AC supply complete including Louvers &suitable nuts & bolts and connecting cable from ceiling rose to exhaust fan
M&L for cutting round holes into or through stone walls built in cement mortar or cement lime mortar and walls of cement concrete of superficial of 300 mm dia and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required for exhaust fan opening complete all as specified and directed by Engineer-in-Charge.
Supply and fix single pole and neutral enclosure (SPN) with a two pin and earth plug and socket complete with one single pole MCB of 20/25 Amps rating complete all as specified and as directed. management in multiple optics complete with
Supply and fix Manual Changeover switch suitable for three phase 415 volts 50 Hz 63Amps TPN with connection to DG Set all as specified and directed by Engineer in charge
Disconnecting and removing ceiling fan of any sweep any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including painting of ceiling fan complete with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust etc & testing complete all as specified. NOTE :- (1) Necessary repairs/ replacement of unserviceable parts shall be measured and paid seperately.(2)Labour element for replacing of u/s parts deemed to be included in rate quoted.
Material and labour for rewinding of the ceiling fan/exhaust fan complete with equivalent new super enamelled copper wire of existing gauge and weight as per manufacturer's design and instructions including varnishing of ceiling fan of any make and any sweep complete all as specified and directed including taking out burnt copper wire. Note: old winding material is property of the contractor
Supply only the following items suitable for ceiling fans / exhaust fans of any size and sweep and make :-
(a) Capacitor 2.5 Mfd capacity 240 Volts.
(b) Sealed ball bearing
(c) Rubber bushes with MS clamps,nut,bolts &spilt pins
S & F Vertical type TPN DB 4 way double door with incoming including MCCB TP 63 to 100 Amps as required suitable for 415 volts,16 KA AC 3 phase 50 Hz and suitabe for outgoing SP/TP with isolated neutral bar complete all as specified and directed by engineer in Charge
S and F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 Volts double door with Flush type system complete all as specified.
Supply and Fix MCB SPN 40 Amps suitable for fixing in MCB DB all as specified and directed by engineer in charge
S & F MCB SP 6 to 32 Amps 240 volts 10 KA 'C' series for fixing in MCB DB's all as specified and directed by Engineer in charge
M & L for Submain wiring with two single core 6 Sq mm PVC insulated FRLS copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC surface conduit and conduit accessories of suitable dia medium grade including running up of one runs of 6 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
M & L for Submain wiring with two single core 2.5 Sq mm PVC insulated FRLS copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC surface conduit and conduit accessories of suitable dia medium grade including running up of one runs of 2.5 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
Supply and fixing LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal IP 65/66 protection complete including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box
S & F bracket for security light made out of GI pipe 40 mm dia bore not less than 1.2 mtr long and fixed on walls/poles with 2 nos MS clamps made out of MS flat 40x5mm thick complete with MS nuts, bolts and washers etc complete all as specified and directed by Engg-in-Charge
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom 1.75m long with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate)
Saiansh Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .