Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.8 LAccepted-AOC | ₹15.8 L Quoted ₹16.1 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹16.1 L+₹5,464 (0.34%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | ₹16.1 L+₹5,464 (0.34%) | L-2 | Rejected-Finance other than L-1 |
| 3 | L-3₹18.6 L+₹2.5 L (15.4%)Rejected-Finance 29 IQBAL COLONY SONWAR SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | ₹18.6 L+₹2.5 L (15.4%) | L-3 | Rejected-Finance other than L-1 |
| 4 | L-4₹20.2 L+₹4.1 L (25.5%)Rejected-Finance | ₹20.2 L+₹4.1 L (25.5%) | L-4 | Rejected-Finance other than L-1 |
| 5 | L-5₹21.1 L+₹5.0 L (31.0%)Rejected-Finance | ₹21.1 L+₹5.0 L (31.0%) | L-5 | Rejected-Finance other than L-1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
19 Jun 2023, 6:00 pmClosed
Maj. Sujith Mohan, GE
Garrison Engineer 864 Enggr Wks Sec, PIN-913864,C/o 56 APO
Repair/replacement of Lt panel and UG network at BB Cantt Srinagar
2023_MES_597437_1
864/WS-33/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
B B Cantt.
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹50,000
Yes
11 Aug 2023
22 May 2023
21 Jun 2023
22 May 2023
19 Jun 2023
5 Jun 2023
Amount
Excavation in trenches not exceeding 1.5 mtr in wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavted soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
M&L for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata & relaxing taken out cable complete all as specified and directed.
M&L PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) in coping / plinth blocks for poles and the like including weathering , slightly rounded or chamfered angles and throating, as directed including necessary Steel form work and finishing the surfaces fair in forms complete all as specified and directed.
S & F in replacement of heat shrink insulation tubes for all the bus bars of Lt Panels and maintaining the RYB sequence in the system complete all as specified and as directed
M & L for earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl copper strip 20x3 mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 32x6mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT/HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the over head line Complete side fencing of Sub Station Area 2/4 Pole Structure in the arc of HT/LT overhead lines feeders (including repair and jointing of ACSR conductor if damaged during cutting of trees) and removal of the rimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed Notes :- All tools required for the job shall be arranged by the contractor within the overall cost quoted in the item.
S&F in replacement MCCB 4 Pole, 415 V,16 KA breaking capacity, thermal magnetic type of capacity 40/63/100 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed .
S&F in replacement MCCB 4 Pole, 415 V, 16 KA breaking capacity, thermal magnetic type of capacity 125 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed .
S&F in replacement MCCB 415 V, 4 Pole, 36 KA breaking capacity, adjustable type of capacity 160 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed.
S&F in replacement MCCB 4 Pole,415 V, 36 KA breaking capacity, adjustable type of capacity 200 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed.
S&F in replacement MCCB 4 Pole,415 V, 36 KA breaking capacity, adjustable type of capacity 250 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 36 KA breaking capacity, thermal magnetic type of capacity 315/320 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed.
S&F in replacement MCCB 4 Pole,415 V, 36 KA breaking capacity, adjustable type of capacity 400 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 415 V, 36 KA breaking capacity, adjustable type magnetic type of capacity 500 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 415 V, 36 KA breaking capacity, adjustable type magnetic type of capacity 630 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed .
M&L for electrical insulation tape roll of 25mm wide and 20 Mtr length heavy duty in repair/maintenance of cables or fixing of thimbles or colour coding of cables in panels/joints etc complete all as specified and directed.
S&F in replacement spot light RYG underwater 3/5/7 Watt submersible gardern fountain with RGB lightingh EU plug complete all as specified and as directed by Engr-in-Charge
Supply & laying LT cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 Volts graded of cross section area :-
70 sqmm, 3.5 core.
50 sqmm, 3.5 core.
35 sqmm, 3.5 core.
25 sqmm, 3.5 core.
16 sqmm, 4 core.
10 sqmm, 4 core.
10 sqmm, 2 core.
Supply only for Aluminium thimble/ferrule suitable for LT UG Cable,1100V for the following size of cable:-
M&L for surface dressing not exc 15cm deep and averaging 10cm deep and cleaning of surroundings of electrical installations/sub stations/2 & 4 pole structure/ Panels/ transformers drainage installation by cutting vegetation, bushes, grass etc. and surface dressing, complete all as specified and directed.
S&F in replacement Volt meter digital, 96 x 96mm size, 0-500 volts, AC, complete all as specified and directed.
S&F in replacement ampere meter digital, 96 x 96mm size, 0-100A size, AC, complete all as specified and directed.
S&F in repairs/replacement phase indicating lamps LED type RYB, complete all as specified and directed.
S&F in repairs/replacement die cast resin CT for digital Amp meter, ratio of CT, complete all as specified and directed.
M&L for wiring of voltmeter or ammeter with copper conductor single core 1.5 sqmm size, complete all as specified and directed.
Taking up or down defective/faulty LT underground cable 1100 volts of size upto 185 sqmm 3.5 core from the existing trench /duct/pole etc an Re-laying the same in the trenches/duct/pole etc after rectification of defects, including meggering of cable, provn of cable lugs, glands, thimble, insulation tape and connecting up with existing control gears, panels etc as per site requirement, complete all as specified and as directed. Note:- Excavation, returning filling etc shall be measured and paid seperately.
Supply, installation, testing and commissioning of LT Panel board suitable for 415 Volts, 3 Phase 4 wire, 50 Hz AC supply system confirming to IS:8623/93, outdoor type floor mounted alongwith factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15mm thick with ingress protection of IP-54 grade having heat shrinkable sleeves, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof. The panel shall be front/rear openable and having inner & outer shells. The inner shell dully compartmented for each control gear, including powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1200 mm x 1200 mm x 450 mm , mounted on angle iron stand made out of angle size 50x 50 x 6mm grouted in PCC foundation in cement concrete 1:2:4 type B-1 platform 70 cm above the ground level and 45 cm below the ground level (using 20mm graded crushed stone aggregate),
S&F control unit into sheet metal enclosure on suitable angle iron stand including all fixing accessories, complete all as specified and directed and including following :- (a) Each control unit consist of MCCB 63 Amps - 01 No. (b) Single phase preventor - 01 No. (c) RYB indication LED light - 01 Set (d) Ammeter 0-100 Amps - 01 No. (e) Voltmeter 0-500 Volts - 01 No.
S&F microprocessor based singal phase electronic meter temper proof energy meter of rating 10-60 Ampere with optical cummunication port, confirming to IS-13779 of 1999, IEC 1036 and CBIP technical report 1988, 2 wire, 240 Volts, 50 Hz with fixing arrangement including taking down old old one, complete all as specified and directed .
S&F Trivector meter, three phase, 4 wire, 3x240 volts, temper proof energy meter of rating 10-60 Ampere with optical cummunication port, confirming to IS-13779 of 1999, IEC 1036 and CBIP technical report 1988, 2 wire, 240 Volts, 50 Hz with fixing arrangement including taking down old old one, complete all as specified and directed.
M&L for submain wiring with three single core 6 Sqmm PVC insulated unsheathed copper conductor cable, drawn in and including 19/20mm dia PVC rigid non metalic conduit / flexibe PVC pipe medium density, ISI Marked, complete. Note:- 3 runs of 6 Sqmm (3x6sqmm ) cable and one run of conduit will be measured as one unit.
M&L for submain wiring with three run single core 10 Sqmm PVC insulated unsheathed copper conductor cable, drawn in and including 25mm dia PVC rigid non metalic conduit / flexibe PVC pipe medium density, ISI Marked, complete all as specified and directed. Note:- 3 runs of 10 Sqmm (3x10sqmm ) cable and one run of conduit will be measured as one unit.
Supply & fix single pointed air termination copper rod 12mm dia, 300 mm long on roof of Gurad Posts and Watching towers in various location complete all as specified and directed.
Supply & fix aluminium strip 32 mm x 6 mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M&L for PCC block of size 0.30m x 0.30m x 0.60m in cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) including necessary formwork for fixing GI pipe 50mm bore, complete all as specified and directed.
Supply and fixing in replacement On load change over switch in sheet metal enclousure 4 of pole of capacity 63 Amp complete all as specified and directed.
Supply and fixing in replacement On load change over switch in sheet metal enclousure 4 of pole of capacity 100 Amp complete all as specified and directed.
Supply and fixing in replacement On load change over switch in sheet metal enclousure 4 of pole of capacity 160 Amp complete all as specified and directed.
Supply and fixing in replacement On load change over switch in sheet metal enclousure 4 of pole of capacity 200 Amp complete all as specified and directed.
Supply and fixing in replacement On load change over switch in sheet metal enclousure 4 of pole of capacity 320 Amp complete all as specified and directed.
Supply and fixing in replacement On load change over switch in sheet metal enclousure 4 of pole of capacity 400 Amp complete all as specified and directed.
Supply and fixing in replacement On load change over switch in sheet metal enclousure 4 of pole of capacity 630 Amp complete all as specified and directed.
Supply and fix in replacement busbar chamber wall mounted 8 way 250 Amps cubical type complete all as specified and directed.
Supply and fix in replacement busbar chamber wall mounted 8 way up to 315 Amps cubical type complete all as specified and directed.
Supply and fix in replacement busbar chamber wall mounted 8 way 400 Amps cubical type complete all as specified and directed.
Supply and fix in replacement busbar chamber wall mounted 8 way 630 Amps cubical type complete all as specified and directed.
Supply and fixing in replacement MCB SP 240V, 10KA 'C' curve miniature circuit breaker and current carrying capacity 6 to 32 Amps in the MCB DB or FRP looping box of security lights poles/ panels complete with connection testing and commissioning all as directed.
Supply and fixing in replacement MCB SPN 240V, 10KA 'C' curve miniature circuit breaker and current carrying capacity 32 Amps in the MCB DB or FRP looping box of security lights poles/panels complete with connection testing and commissioning, all as directed.
VEDA INFRASTRUCTURE
M/S TAHIRA ENTERPRISES
M/S VALLEY ENTERPRISES
M/S Khan Hussain & Co.
NORTHERN ELECTRICAL WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .