Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 CrAdmitted-Finance | ₹15.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹16.1 Cr+₹27.7 L (1.75%)Admitted-Finance DHANBAD | DHANBAD | JHARKHAND | 818142 | ₹16.1 Cr+₹27.7 L (1.75%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Dilip Kumar Ray L1 | SANJAY KUMAR SHARMA ENGICON PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.00Elevated Storage Reservoir | |||||
| 1.01Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging Consisting of columns, internal and External bracings spaced vertically not More than 4.0 metres centre to centre for ESR having capacity upto 500 cum and Not more than 6m c/c for ESR shaving Capacity above 500 Cum including Excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and outside face of the container and also plaster with plastic paint in all columns and bracings including refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, outside, Stainless steel ladder in contenor, C.I. manhole frame and covers, water level indicators,l ightening conductor, G.I. pipe railing around walk way and top slab, Providing Stair case from ground level to roof level , MS Grill Gate of 2M Height with locking arrangement of approved design,B.B. Masonary Chambers For all valves ventilations shafts, providing and applying three coats acrylie emulsion with silicon edditives paint to the structure including roof slab, epoxy painting to internal surface and anti-termite treatment for underground part soft the structure and giving satisfactory water tightness test as per IS code. the job to include painting then ame of the scheme and other details on the reservoir as per the directions of engineer in chief. | |||||
| 1.02Providing spiral stair case from ground level to roof level, M.S. Grill gate of 2M height with locking arrangement of approved design, B.B. Masonry chambers for all valves, providing and applying three coats of Cement paint to the structure including roof slab, epoxy painting to internal surface and anti-termite treatment forunder ground part soft he structure and giving satisfactory water tightness test as per I.S. code. The job to include painting then ameof the scheme and other details on there servoir as per the directions of Engineer In - Charge. | |||||
| 1.03Notes | |||||
| 1.04The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 2009 or revised.) | |||||
| 1.05The design shall satisfy the stipulations as per I.S. 1893 -1984 and I.S.13920/1993 for seismic force and I.S.-11682 / 1985 for R.C.C. staging of over head tanks. | |||||
| 1.06For design having more than 6 columns, provision of internal bracing is obligatory. External bracings is also obligatory. | |||||
| 1.07The Entire structure shal be M/250 mix only .However concrete in contract with water such as container base slab,walls,roofs slab & putting in water base area shall be in M300 | |||||
| 1.08Plain round mild steel bars grade- I conforming to I.S.432 part-I orhigh yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall beused, grade- I Imild steel bars will not be allowed | |||||
| 1.09Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. | |||||
Tender Value
₹14.6 Cr
EMD Value
₹14.6 L
Closing Date
11 Apr 2022, 4:00 pmClosed
EXECUTIVE ENGINEER
DWSD No-1, Giridih
Construction of Dhengadih and adj village Rural Water Supply Scheme
2022_DWSD_57459_1
DWSD/RPWS/GIRIDIH-1/31/2021-22
Open Tender
Civil Works - Water Works
Turn-key
365 days
UNDER DWSD NO 1 GIRIDIH
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
EXECUTIVE ENGINEER DWSD NO 1 GIRIDIH
₹14.6 L
O/O ENGINEER IN CHIEF DWSD
27 Jun 2022
2 Apr 2022
13 Apr 2022
2 Apr 2022
11 Apr 2022
2 Apr 2022
4 Apr 2022
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Elevated Storage Reservoir | |||||
| 1.01 | Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging Consisting of columns, internal and External bracings spaced vertically not More than 4.0 metres centre to centre for ESR having capacity upto 500 cum and Not more than 6m c/c for ESR shaving Capacity above 500 Cum including Excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and outside face of the container and also plaster with plastic paint in all columns and bracings including refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, outside, Stainless steel ladder in contenor, C.I. manhole frame and covers, water level indicators,l ightening conductor, G.I. pipe railing around walk way and top slab, Providing Stair case from ground level to roof level , MS Grill Gate of 2M Height with locking arrangement of approved design,B.B. Masonary Chambers For all valves ventilations shafts, providing and applying three coats acrylie emulsion with silicon edditives paint to the structure including roof slab, epoxy painting to internal surface and anti-termite treatment for underground part soft the structure and giving satisfactory water tightness test as per IS code. the job to include painting then ame of the scheme and other details on the reservoir as per the directions of engineer in chief. | - | - | - | - |
| 1.02 | Providing spiral stair case from ground level to roof level, M.S. Grill gate of 2M height with locking arrangement of approved design, B.B. Masonry chambers for all valves, providing and applying three coats of Cement paint to the structure including roof slab, epoxy painting to internal surface and anti-termite treatment forunder ground part soft he structure and giving satisfactory water tightness test as per I.S. code. The job to include painting then ameof the scheme and other details on there servoir as per the directions of Engineer In - Charge. | - | - | - | - |
| 1.04 | The design of the structure be in accordance with relevant I.S. specification (I.S. 3370 - 2009 or revised.) | - | - | - | - |
| 1.05 | The design shall satisfy the stipulations as per I.S. 1893 -1984 and I.S.13920/1993 for seismic force and I.S.-11682 / 1985 for R.C.C. staging of over head tanks. | - | - | - | - |
| 1.06 | For design having more than 6 columns, provision of internal bracing is obligatory. External bracings is also obligatory. | - | - | - | - |
| 1.07 | The Entire structure shal be M/250 mix only .However concrete in contract with water such as container base slab,walls,roofs slab & putting in water base area shall be in M300 | - | - | - | - |
| 1.08 | Plain round mild steel bars grade- I conforming to I.S.432 part-I orhigh yield strength deformed bars conforming to I.S. 1786 or I.S. 1139 shall beused, grade- I Imild steel bars will not be allowed | - | - | - | - |
| 1.09 | Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. | - | - | - | - |
| 1.1 | These rates include providing M.S. ladder for E.S.R.s upto 2 lakh litres capacity and providing spiral stair case for E.S.R. above 2 lakh litres capacity. | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.03 MB
SBD.pdf
Tender Documents • 0.93 MB
BOQ_77596.xls
BOQ • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .