RequiredExperience with Government
RequiredOEM Authorization Certificate Bid to RA enabled No LED Luminaire (for Flood Light) ( 30 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) STANDARDS LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes * Photo biological safety of LEDs used shall be as per IS:16108/2012 (exempt group) Yes * Types of LED Luminaire Type B * 1/7 as per the IS: 16107(Part-2 Sec.-1)/2012 Types of LED Modules as per the IS: 16103(Part-2)/2012 Type 3 * LED Rating/System Wattage/Rated Power 120W 120W Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt * Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP65 IP65 Mounting brackets (included) Adjustable * Warranty for free replacement (in Years) 2 2 ELECTRICAL EFFICIENCY Input operating Voltage range and frequency 140 to 270 V olts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V * Automatic Higher Cut off voltage above 300 volt Yes * Rated voltage 230 V AC 50 Hz * AC Power Factor at full load ≥ 0.95 * Driver Efficiency (in %age) ≥85 * Total Harmonics Distortion (in %age) ≤ 10 * "The total circuit power shall not be more than 110 percent of the value declared by the manufacturer" Yes * OPTICAL LED chip Efficacy ≥130 Lm/Watt * Colour temperature (+/-500K) 6000K * Working life for LED (Minimum 50
Required000 burning hours as per LM-80 report) Yes * Colour Rendering Index(CRI) ≥70 * Beam Angle ≥120 * 2/7 Optic lense materal (UV stabilised) (Write NA for without optic lense supply) Poly carbonate lense * THERMAL MANAGEMENT Heat sink should be die- cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes * Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes * Junction temperature < 85 degC * Operating temperature range -20 deg C to +50 deg C * Operating Humidity Range 10 % to 95% RH * PROTECTION Short circuit Protection Yes * Over load protecton Yes * Over Voltage protection Yes * Reverse polarity Yes * High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes * Insulation resistance between earth and current carrying part >100 M ohm * The luminaire shall be protected against surges and transients ( Internal) >/=5KV * The luminaire shall be protected against surges and transients of >/=10KV (External) Yes * CONSTRUCTIONAL The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes * The luminaire body must be corrosion resistant epoxy powder coated Yes * 3/7 All fastners must be of stainless steel Yes * The entire housing (both LED section and driver section) shall be dust and water proof having IP 66 protection as per IS:10322 (Part 1):1982 latest Yes * Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust
Requiredwater
Requiredinsects etc.
RequiredYes * Luminaries light transparency should be of Toughened glass Yes * Toughned transparent glass cover thickness >/=4 mm * Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes * Number of electronic control gear (power supplies) 2 Nos. 2 Nos. Driver components shall be industrial grade or above Yes * PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes * The Luminaires works on single phase three wires system (Phase
RequiredNeutral and Earth) Yes * Suitable connector shall be provided for LED connection between driver output and LED Yes * Length of ISI marked three core wire (shall be provided along with 50 cm * 4/7 supply of material) Light Source SMD LED Chip as per LM 80/IS16106 * MARKING "Manufactures Name and and brand on the aluminium die cast body Engraved/Embossed * Manufacturer’s name
Requiredmodel number
Requiredserial number Yes * Date of manufacture (month-year)
Requiredand lot number as identification mark inside each unit and the outside of each packaging box Yes * The operation characteristics voltage and power be marked inside of each LED luminaire unit Yes * REPORTS AND CERTIFICATIONS LED Make OSRAM/NICHIA/CREE SAMSUNG/SEOUL LUMILED/PHILIPS EDISON/SYSKA LUMENMAX EVERLIGHT BRIDGELUX NATIONSTAR/REFOND * System must have EMI/EMC compliance as applicable (Test reports shall be furnish on demand by buyer/consignee) Yes * LM 79 (Photometry) (Ref.IS:16106:2012) report from Central Government lab/NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-79 report shall have total lumen output
Requiredpower
RequiredPF
RequiredCurrent in Amps
RequiredCRI & CCT etc.
Required) Yes * LM 80 & TM 21 (Part of LM 80) (Ref. IS:16105:2012) Reports and Photo biological Yes * 5/7 report for LED report from Central Government lab NABL/ILAC accrediated lab. Reports shall be furnish on demany by buyer (LM-80 report shall haveand the Pohoto Biological report of the LED Chip being used in the luminaire) Availability of test Report from Central Government lab/NABL/ILAC accrediated lab to Indian Standrad IS:10322/part 5/sec-5/2012 and IS 16107 (Part 2/Sec 1) : 2012 Yes * Seller has to furnish Type test report on demand by buyer/consignee Yes * DC or AC supplied electronic control gear for LED Module shall comlpy as per IS:15885 (Part 2/Sec.13) Yes * LED Luminaire for Flood Light shall comply with Complusory Registration(CRS) of BIS for safety as per IS 10322 (Part 5/Section 5): 2012 as applicable on the date Yes * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.