| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹4.8 L+₹79,999 (19.8%)Rejected-Finance PLOT NO 361 FLAT NO 06 FIRST FLOOR SECTOR 11 HIRAN MAGRI UDAIPUR 313001 RAJ | UDAIPUR | UDAIPUR | RAJASTHAN | 313001 | L2 | Rejected-Finance HIGHER AMOUNT QUOTED |
Tender Value
₹7.3 L
EMD Value
₹14,700
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I UDAIPUR
ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
PROVN OF CERTAIN SANCTION WORKS AT UDAIPUR MIL STN UNDER AGE (I) UDAIPUR
2020_MES_385238_1
8537/E8/AGE I UDAIPUR
Open Tender
Miscellaneous Works
Item Rate
120 days
ARMY AREA UDAIPUR
AS PER NIT
5 documents required · 5 mandatory
₹500
AGE I UDAIPUR
₹14,700
Yes
19 Dec 2020
10 Oct 2020
6 Nov 2020
10 Oct 2020
4 Nov 2020
14 Oct 2020
60 days
Amount
Material & Labour for Submain wiring with two run of single core FRLS 4 Sqmm multi stranded copper conductor cable drawn through and incl 25 mm dia PVC non metallic rigid conduits and the conduits accessories incl one run of earth continuity conductor with 2.5 sqmm multi stranded copper conductor cable all as specified and directed. Note :- Two run of single core cable and one run of earth continuity conductor and one metre of conduit shall be measured as one unit.
Fixing only wall mounted split Air conditioners, indoor and outdoor units complete with cordless remote control unit and with in built , air ioniser and plasma filter for better indoor air quality with cooling and heating function of capcity 1.5 TR, single phase,240 volts, electric driven to be fitted on wall with rawl plugs including making holes for inlet/outlet in the wall and making good existing surfaces including insulation of tubing with expanded polyethylene foam insulation tubing and making necessary connections including for un plasticized PVC pipes medium duty 20mm dia for draining out condensed water, fixing necessary arrangement of fixing outdoor unit on outside wall with suitable size mild steel angle bracket all as required and directed including necessary connection through voltage stabilizers complete all as spacified and directed. Note:- 1. Wiring between FCU and consensing unit etc shall be deemed to be included in the unit rates quoted. 2. Required length of suitable size copper tubing from FCU to condensing unit shall be deemed to included in the unit rates quoted.
Supply & Fixing Voltage stablizer for automatic operation, SP naturally air cooled in door type designed for input variation 170 V to 250 V output stablized at 230 V with accuracy of + 2.5% and capacity 2KVA complete all as specified and directed. Make: Voltas/ Bule star/ LG
Fixing of Deep Freezer single door hard top 240 volt, 50 Hz, capacity 300 ltr to 320 ltr, electric driven, single phase complete all as specified and directed.
Material & Labour for cutting holes exc. half brick but not exc one brick in stone walls built in CM or in cement lime mortar for inserting holdfasts & making good dismantled portion in CM(1:3) or PCC(1:2:4) Type B-1 as required complete all as specified and directed.
Material & Labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in fixing hold fast complete all as specified and directed.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed.
Material & Labour for applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and directed.
Material & Labour for applying two coats of cement base paint, white or tinted on old wall surface including preparation of surface.
Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out soft/loose soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm soft/loose soil.
Removing excavated material n exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting point
Supply and LayTubes Medium Grade,galvanlised with all fitting laid in borewell of dia 50 mm. Note:-i) Rates to be deemed including joint of GI tubing with screwed flanged joints,together with all fittings (such as bends,elbows,tees,short pieces,connectors,back nuts,diminishing pieces,caps,plugs and unions,etc)and fixing complete with clips etc.
Supply and fix fully automatic star delta starter with sheet steel enclosure suitable for -5 HP submersible motor in existing location including making connection with PVC insulated 1100 volts grade ,single core , multistranded copper conductor 4 of size 10.0 sq mm ,all as directed and specified .
Supply and fixing in position cast iron non return valve of size 80 mm internally screwed ISI marked.
Supply, installation and testing of Submersible pump, electric driven 415 V, TP suitable for 150 mm dia bore well ( Casing pipe size 150 mm) 5HP 10 Stage Pump all as specified and directed.
Material & Labour for XPLE insulated Armoured heavy duty electric cable with aluminium conductor,1000 Volts grade, cross sectional area 16 sq.mm 4 Core
Material & Labour for Sand Cushioning for PVC cable screened and washed sand and punning to provide a required covers all as specified and directed
Material and labour for stone slab roughly hammered dressed stone 25 to 40 mm thick 25 to 30 cm wide and not less than 60 cm long laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over underground cable protection
Fixing only chain link fencing including line wires, any mesh, size & type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as speified and directed.
Supplied only Mild Steel galvaised Chain link fencing, of any size, thickness or type complete all as speified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal /square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 10cm & n exc 15cm long dia of shank 5 to 10 mm
S&F Roof trusses/ hollow section (Square or rectangular tube) (framed), trussed purlins crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats, Flat iron Fillets etc fixed in poisition conforming to Fe-410 (Gde-250) complete all as speified and directed.
M/s Ajay kumar Garge
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .