Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 CrAccepted-AOC 143 RAM GALI HAJINDER NAGAR II KANPUR UP PIN 208007 | KANPUR NAGAR | UTTAR PRADESH | 208007 | ₹5.1 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹5.5 Cr+₹40.2 L (7.95%)Rejected-Finance 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹5.5 Cr+₹40.2 L (7.95%) | L2 | Rejected-Finance BEING OTHER THAN LOWEST |
| 3 | L3₹5.8 Cr+₹74.6 L (14.8%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹5.8 Cr+₹74.6 L (14.8%) | L3 | Rejected-Finance BEING OTHER THAN LOWEST |
| 4 | L4₹6.5 Cr+₹1.5 Cr (29.3%)Rejected-Finance | ₹6.5 Cr+₹1.5 Cr (29.3%) | L4 | Rejected-Finance BEING OTHER THAN LOWEST |
| 5 | L5₹6.8 Cr+₹1.7 Cr (34.3%)Rejected-Finance NOT SPECIFIED | ₹6.8 Cr+₹1.7 Cr (34.3%) | L5 | Rejected-Finance BEING OTHER THAN LOWEST |
Tender Value
₹7.0 Cr
EMD Value
₹6.7 L
Closing Date
5 Sept 2023, 6:00 pmClosed
CE (AF) Prayagraj
CE (AF) Prayagraj UP Pin 211012
PROVISION OF MAFI SUBSTATION AND ALLIED WORKSAT AF STATION BIHTA
2023_MES_603963_1
958801/C/E8
Open Tender
Civil Works
Lump-sum
365 days
BIHTA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE(AF) Bihta
₹6.7 L
Yes
2 Nov 2023
17 Jun 2023
12 Sept 2023
17 Jun 2023
5 Sept 2023
22 Aug 2023
Amount
SCHEDULE A PART I (BUILDING WORKS)
Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I .
Sch A Part II (INTERNAL ELECTRIFICATION )
Lump sum price worked out by the contractor for Internal Electrification as listed in Sch ‘A’ Part II .
Sch A Part III (INTERNAL WATER SUPPLY )
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL ELECTRIFICATION )
Lump sum price worked out by the contractor for External Electrification as listed in Sch ‘A’ Part IV .
Sch A Part V (EXTERNAL WATER SUPPLY )
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part V.
Sch A Part VI (ROAD/ PATH & CULVERT)
Lump sum price worked out by the contractor for Road, Path & Culvert as listed in Sch ‘A’ Part VI.
Sch A Part VII ( SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for Sewage disposal as listed in Sch ‘A’ Part VII
Sch A Part VIII (AREA DARINAGE)
Lump sum price worked out by the contractor for Area drainage as listed in Sch ‘A’ Part VIII
Sch A Part IX (SECURITY WALL & FENCING )
Lump sum price worked out by the contractor for Security Wall & fencing as listed in Sch ‘A’ Part IX.
Sch A Part X (LIGHTENING PROTECTION)
Lump sum price worked out by the contractor for Lightening protection as listed in Sch ‘A’ Part X.
Sch A Part XI (STEEL GATE)
Lump sum price worked out by the contractor for Steel gate as listed in Sch ‘A’ Part XI.
Sch A Part XII (SITE CLEARANCE/ AREA DEVELOPMENT)
Lump sum price worked out by the contractor for Site clearance/Area development as listed in Sch ‘A’ Part XII
Sch A Part XIII (Miscellaneous Items of B/R and E/M)
S&F ceiling fan 1200mm sweep, BEE 5 Star rated, ceiling fan with brushless direct current (BLDC) motor, class of insulation : B, 3 Nos blades, 30 cm long down rod, 2 Nos canopies, shackle kit, safety rope, electronic regulator unit for speed control, copper winding power factor not less than 0.9, service valve ( CMM/W) minimum 6, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019 ), THD less than 10% and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm suitable for 230 V, 50 Hz single phase AC supply, earthing etc including necessary connection with ceiling rose 3 core 1.0 Sqmm PVC insulated round flexible cable complete all as specified & directed
S&F Air Ventilating fan AC single phase 230 volts 50 Hz of size 300 mm sweep metallic body with louvers and connecting the same to electric source with using copper conductor 1.5 Sq mm PVC insulated flexible three core cable complete including cutting the square / round hole of required size in wall, finishing the same for disturbed surfaces to match with the adjoining surface complete all as specified & directed.
S&F Exhaust fan of 450 mm sweep BEE 3 star rating (heavy duty) metallic body single phase 230 V, AC, 1400 RPM with louvered shutter including mounting frame, nut bolts, washers, fasteners etc with suitable size hole and connecting up including provision of 3 core of 1.5 Sqmm multi stranded copper conductor cable IS-694 marked from ceiling rose to exhaust fan connector and testing etc including cutting the square / round hole of required size in wall, finishing the same for disturbed surface to match with the adjoining surface complete all as specified and directed.
S & F wall mounted type LED light fitting batten type complete with LED 1 x 20 watt (4 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrated electronic driver complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable suitable size. etc complete all as specified and directed.
S & F wall/surface mounted type bulk head LED light fitting complete with LED lamp of 1x 10 watt, made of polycarbonate housing & enclosed with cover & integrated electronic driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable suitable size etc complete all as specified and directed.
S & F suspended LED light fitting batten type complete with LED lamp of 1x 20 watt (4 ft) extruded aluminium body with heat sink provided for efficient heat dissipation and integrated electronic driver complete with all accessories internally prewired and including connecting up with three core twisted flexible copper conductor cable complete all as specified & directed.
S & F wall / surface mounted type LED mirror light fitting batten type complete with LED lamp 05 watt white / cool white (1 ft long) polycarbonate body and integrate electronic drive complete with all accessories internally prewired and including connecting up with three core twisted flexible copper conductor cable complete all as specified & directed.
S&F MCB TPN 63 Amp, 415 V, 'C' curve, having current rating 10 KA complete including providing thimble for outgoing cables all as specified and directed.
S & F MCB SP, 6 to 32 Amps , 240 volts, 'B' curve, having current rating 10 KA complete including providing thimble for outgoing cables all as specified and directed.
S & F MCB SPN, 32 to 40 Amps , 240 volts, 'B' curve, having current rating 10 KA complete including providing thimble for outgoing cables all as specified and directed.
M & L for earthing complete with Galvanised steel earth plate 600 mm x 600 mm x 6mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.50 mtr below normal ground level connected to continuous (without joint) galvanised wire 4 mm dia as earthing wire (lead) by means of bolts, nuts, check nuts and washers of brass connected including gun metal or phosphorus bronze of size 75 mm x75 mm x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil including 15 mm bore Gl tubing light grade and necessary fitting for protection of Gl wire including laying of charcoal, dust and common salt, 40 mm thick pre-cast reinforced cement concrete (Not less than M20 grade nominal mix) cover with 8 mm dia TMT bars@ 75 mm c/c both way with 12 mm dia round bar as handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, 15mm thick rendering in cement mortar 1:4 internally and upto 150mm below ground level & externally. PGI funnel with wire mesh, complete all as shown on electrical plate No.3 of SSR Part -1( 2009) and connected in earth test including and marking building numbers and writing test results on a 3.00 mm thick painted mild steel earth pit marking plate (200 mm x 100 mm) duly welded with a 450 mm long 100 mm dia round MS rod fixed with the earth pit chamber by grouting and provision of arrangement of making of test result complete all specified and directed. Note :- (i) The unit rate quoted is deemed to be inclusive of cost of Earth test point and earth wire and protection pipe upto 7.5 metre beyond the earth plate electrode and the earth resistance of the whole system shall be as near as possible to 0 but shall not exceed 5 ohm in any case
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick, directly buried in the ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron strip of size 32 x 6mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe for earth strip, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, with RCC cover 40 mm thick 1;2:4, Type B0 (Using 12.5 mm graded crushed stone aggregate) reinforced with 8mm dia TMT bars @75 C/C both ways with MS handle 8mm dia, and angle iron 40x40x3mm frame and chamber of PCC (1:3:6) type C-1 (Using 20 mm graded crushed stone aggregate) including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m and connecting, testing and marking building numbers and writing test results on a 3.00 mm thick painted mild steel earth pit marking plate (200 mm x 100 mm) duly welded with a 450 mm long 100 mm dia round MS rod fixed with the earth pit chamber by grouting complete all as shown on electric plate No. 03 of SSR-2009 Part-I complete all as specified and directed. Notes: (a) The unit rate quoted is deemed to be inclusive of cost of Earth lead & protection pipes length upto & including 7.50 metre (b) Earth filling shall be done by approved soil (c) Soil should be free from stone, boulders, aggregate, gravels etc.
M&L for Sub main wiring with two runs of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC concealed conduits medium grade ISI marked 32mm dia (External)in roof & walls with conduit accessories and one run of single core PVC(Green colour) insulated but unsheathed multi stranded copper conductor of size 1 x 4 Sqmm 1100 volts grade cable as earth continuity conductor including making good the disturbed surfaced to match the existing surface complete all as specified and directed. Note: Two runs of 4 Sqmm , one run of 4 Sqmm earth conductor and one run of conduit shall be measured and paid as one metre length of unit.
S&F LED Street light fitting having ingress protection class minimum IP-65 , suitable for road lighting luminaire with high power LED and maintenance free system for capacity 20 W complete with and including 32 mm bore light grade GI pipe bracket (1.5m long) duly bent to shape including 2 Nos mild steel Flat iron (40 mm x 5 mm) clamps, nuts, bolts, washers etc. complete all as specified and directed. Note : Mild steel clamps, nuts, bolts, washers etc shall be painted with 2 coats of aluminium paint over a coat of red oxide metal primer before fixing at different positions.
M&L for cutting into existing main distribution G.I. pipe line and inserting 'Tee' of size 40 mm x 40mm x 25 mm with all connected accessories complete all as specified & directed.
M&L for brick masonry valve pit chamber of size 600 mm x 600 mm x 600 mm( internal dimension), with 3.15 mm thick mild steel sheet cover fixed with two Nos stainless steel hinges of 75 mm long on angle iron frame of size 40 mm x 40 mm x 6 mm thick (mild steel sheet cover and angle iron frame shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer) , PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate ) as in foundation, 230 mm thick brick masonry wall with sub class B bricks, built in cement mortar 1:4, 50mm thick coping with PCC 1:3:6 , type C-0 ( using 12.5mm graded crushed stone aggregate) , 15 mm thick rendering in cement mortar 1:4 to all internal and exposed surfaces of valve pit including necessary excavation and earth work etc complete all as shown in drawing & as directed.
Supply, laying , jointing & testing of HT XLPE cable 95 Sqmm, 3 core, 11000 volt grade (earthed) screened, PVC bedded, galvanised steel strip armoured (Heavy duty) with aluminium stranded conductor ISI marked IS-7098 (Part-I) 1977 and Part-II of 1985 laid in pipe / ducts/ trenches under floor and road or fixed to wall etc complete all as specified & directed. Note:- Excavation & earthwork will be measured & paid under respective items.
S&F cable jointing kit suitable for HT 11 KV (earthed) grade cable for indoor type cable end termination cold shrink type joint complete with jointing material and accessories for HT cable 95 Sqmm, 3 core XLPE, armoured, aluminium stranded conductor complete all as specified & directed.
S&F cable jointing kit suitable for HT 11 KV (earthed) grade cable for outdoor type cable end termination cold shrink type joint complete with jointing material and accessories for HT cable 95 Sqmm, 3 core XLPE, armoured, aluminium stranded conductor complete all as specified & directed.
S&F cable jointing kit suitable for HT 11 KV (earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories for HT cable 95 Sqmm, 3 core XLPE, armoured, aluminium stranded conductor complete all as specified & directed.
S&F precast cement concrete factory made kerb stone of size 300 x 250 x 100 mm (Sketch enclosed) laid and set in cement mortar 1:4 complete all as specified and as directed. Note : (a) Grade of Concrete Mix shall not be less than M25 (b) Kerb stones shall be tested in NABL approved laboratory for grade of concrete and test certificate shall be produced by the contractor before incorporation in the work (c) Cost of testing charges are deemed to be included in the unit rate quoted.
M&L for 150 mm spread thickness granular sub base using broken graded stone aggregate 40mm to 63mm size interstices filled laid in two layers of 75mm thickness each layer spread, rolled and consolidated to required gradient and camber as required complete all as specified and directed.
Supply, installation, testing & commissioning of SF insulated VCB, HT 11 KV, 3 Phase, 50 HZ, indoor type, totally enclosed/metal clad switch gear complete having rupturing capacity of 400 MVA, 400 Amps, overload earth fault and short circuit protection, Voltmeter range (0-15 KV) and Ammeter (0-630 Amps), required battery bank with charging arrangement complete of following specifications mentioned in IS/IEC-62271-100 &200 including latest amendments/additions including following:- (a) Motorised spring charging mechanism with 24 volts DC universal motor 200 watts and having charging time less than 10 seconds.(b) Bus bar chamber including a set of 3 phase 600 Amps copper bus bars to be provided for further extension in future, if necessary.(c) Dual core dual ratio Current Transformer (CT) chamber comprising of 3 Nos, single phase resin cast / ring core CTs of 200-100 / 5+5, burden not less than 15 VA and accuracy class 0.5, for metering, having class 5P10 for protection as per IS:2705-01 Set (d) Potential Transformer (PT), 3 Phase, dry type (resin cast) fixed type 11KV/110 Volts, Burden 100 VA, Accuracy class 0.5 with HT & LT HRC fuses/MCB for primary and secondary complete all as specified and as directed as per IS: 3156-01 Set.
(e) SCADA compatible self-powered IDMT numerical relays, over current & earth fault relay with adjustable setting, short circuit fault relay for complete protection of HT, 11KV, 3 Phase feeder having facility to record fault current with MODBUS communication on RS 485 communication port-01 No including 1 No voltage monitoring relay for under voltage/over voltage protection. (f) Earthing switch rated for full making capacity with provision for safe & reliable position indicator (g) (i) Assembly of Vacuum circuit breaker shall be completely insulated as per the relevant IS/IEC (ii) The vacuum interrupted bottle shall be of the same make of VCB (iii) Spring charged and electrically operated independent closing/ tripping, trip, free, operating mechanism including manual closing/tripping push button and breaker close/ open option shall be provided . Note:- 1. Any auxiliary fittings/fitments for protection and functioning shall be provided as per the relevant IS.2. The contractor shall submit GA drawings and technical specification of VCB to GE for his approval before placing order 3. VCB has to be integrated with existing HT Panel/RMU and cost of integration is deemed to be included in quoted rate.
Supply, installation, testing & commissioning of 11 KV, 400 A, 3 pole, 50 HZ , 26 KA for 3 sec rupturing capacity, floor mounted, compartmentalised, indoor type, free standing [grouted in PCC 1:2:4 type B1(Using 20 mm graded stone aggregate)], duly labelled with vinyl stickers, modular construction, 6 way HT Panel fabricated in minimum 14 SWG CRCA sheet, supported with suitable size base channel not less than 75x75x5 mm, painted in Siemens Grey shade RAL 703, compartmentalised, dust and vermin proof, minimum IP 42 protection with bus /PT/relay compartment having IP 52 , doors and covers with non-ageing gasket, doors with concealed hinges with handle and locking facility, electrolytic grade copper bus bar of rectangular cross section of adequate size for 600 A , cable glands, cable bottom entry for incoming and outgoing cable, danger plate, thermostatically controlled strip heater with provision of double earthing terminals, lifting studs, louvers for proper ventilation covered with fine GI screen comprising of following : - (For Sub Station No. 1) (a) 11 KV, 3 pole, 50 HZ 400 A draw out type VCB -06 Nos ( 02 Nos for incoming, 02 Nos for outgoing and 02 Nos for bus coupler) confirming to IEC 62271-100 and 62271-200 ,E2 class, rupturing capacity 25 KA for 03 seconds, manual and motorised spring charging mechanism suitable to operated by 240 volts AC single phase/110 V DC supply. 24 volt DC universal motor 200 watts and having charging time less than 10 seconds or as all per Original Equipment Manufacturer (OEM) design, with overload, earth fault and short circuit protection, interrupter life minimum 30000 times at rated current and minimum 100 times at short circuit current (b) Dual core dual ratio Current Transformer (CT) chamber, class E insulation, comprising of 3 Nos, single phase resin cast / ring core CTs of 200-100 / 5+5, burden not less than 15 VA and accuracy class 0.5, for metering, having class SP10 for protection as per IS:2705 for each circuit breaker - 06 Sets for 06 VCBs.
(c)1 No. Potential Transformer (PT), 3 phase, dry type (resin cast) fixed type 11 KV / 110 Volts, class 'E' insulation, Burden 100 VA, Accuracy class 0.5 with HT HRC fuses & TPN MCB for primary and secondary respectively complete all as specified and as directed as per IS: 3156 - 02 Set (01 each for incoming) (d) SCADA compatible self-powered , programmable type IDMT numerical relays having overload, earth fault and short circuit tripping facility, facility to record fault event with fault current and nature of fault , adjustable over current & earth fault and fault time setting (separate for earth fault and overcurrent), suitable DC auxiliary supply, housed on horizontal draw out type case, flush pattern with accessories duly connected with trip and alarm system -06 Nos total for complete protection of HT ,11 KV,3 Phase feeder MODBUS communication on RS 485 communication port - 04 No. including 1 No voltage monitoring relay for under voltage / over voltage protection -06 Nos (e) PLC shall also be wired to all VCB's to monitor open/close status. The unit shall be supported with power pack of 110 Volt battery with battery charger (110-volt DC output) for supply backup for PLC & motor operation. The unit shall include all necessary standard fitting required at site.
Supply, installation, testing & commissioning of 11 KV, 400 A, 3 pole, 50 HZ , 26 KA for 3 seconds rupturing capacity, floor mounted, compartmentalised, indoor type, free standing [grouted in PCC 1:2:4 type B1(Using 20 mm graded stone aggregate)], duly labelled with vinyl stickers, modular construction, 6 way HT Panel fabricated in minimum 14 SWG CRCA sheet , supported with suitable size base channel not less than 75x75x5 mm, painted in Siemens Grey shade RAL 703, compartmentalised, dust and vermin proof, IP 42 protection with bus /PT/relay compartment having IP 52 , doors and covers with non-ageing gasket, doors with concealed hinges with handle and locking facility, electrolytic grade copper bus bar of rectangular cross section of adequate size for 600 A , cable glands, cable bottom entry for incoming and outgoing cable, danger plate, thermostatically controlled strip heater with provision of double earthing terminals, lifting studs, louvers for proper ventilation covered with fine GI screen comprising of following : - (for Sub Station No. 2) (a) 11 KV, 3 pole, 50 HZ 400 A draw out type VCB -06 Nos ( 02 Nos for incoming, 02 Nos for outgoing and 02 Nos for bus coupler) confirming to IEC 62271-100 and 62271-200 ,E2 class, rupturing capacity 25 KA for 03 seconds, manual and motorised spring charging mechanism suitable to be operated by 240 Volts, 1 P/110 V DC supply 24 volt DC universal motor 200 watts and having charging time less than 10 seconds or as all per OEM design, with overload, earth fault and short circuit protection, interrupter life minimum 30000 times at rated current and minimum 100 times at short circuit current. (b) Dual core dual ratio Current Transformer (CT) chamber, class E insulation, comprising of 3 Nos, single phase resin cast / ring core CTs of 200-100 / 5+5, burden not less than 15 VA and accuracy class 0.5, for metering, having class SP10 for protection as per IS:2705 for each circuit breaker - 06 Sets for 06 VCBs.
(c)1 No. Potential Transformer (PT), 3 phase, dry type (resin cast) fixed type 11 KV / 110 Volts, class 'E' insulation, Burden 100 VA, Accuracy class 0.5 with HT HRC fuses & TPN MCB for primary and secondary respectively complete all as specified and as directed as per IS: 3156 - 02 Set (01 each for incoming) (d) SCADA compatible self-powered , programmable type IDMT numerical relays having overload, earth fault and short circuit tripping facility, facility to record fault event with fault current and nature of fault , adjustable over current & earth fault and fault time setting (separate for earth fault and overcurrent), suitable DC auxiliary supply, housed on horizontal draw out type case, flush pattern with accessories duly connected with trip and alarm system -06 Nos total for complete protection of HT ,11 KV,3 Phase feeder MODBUS communication on RS 485 communication port - 04 No. including 1 No voltage monitoring relay for under voltage / over voltage protection -06 Nos (e) PLC shall also be wired to all VCBs to monitor open/close status. The unit shall be supported with power pack of 110 Volt battery with battery charger (110 volt DC output) for supply backup for PLC & motor operation. The unit shall include the following with all necessary standard fitting required at site (f) One set of mechanical indicator for ON / OFF indication for all VCB (g) LED type indication lamps for CB ON, CB Close, CB trip, spring charged , Trip circuit healthy with push button and one set of capacitive voltage indication for R-Y-B -01 set for each VCB
Supply, install, commissioning and testing step down transformer indoor type, HT 11 KV , 3 Phase 433 Volts, 4 wire, 50 HZ Delta /Star connected, vector group DYN 11 double copper wound, ONAN, on load tap changing facility on HT side to vary secondary voltage of + 7.5% in steps of 2.5%, continuous rating of capacity 160 KVA including bushing on HT and cable end box on LT side. The transformer shall be confirming to IS-1180 Part 1 : 2014 and BEE 3 level certified complete with all standard fittings and accessories, gauges, first filling of transformer oil etc complete all as specified and as directed (For Sub Station No. 2) (a) Oil conservator with filling hole and cap drain valve and oil level gauge (b) Silica gel breather with connecting pipe, first fill of dehydrating agent (c) Explosion relief mounted on tank with double diaphragm and equalizer pipe connected to conservator air spoon (Pressure release valve.)(d) Air release plug. (e) Oil temperature indicator (gauge) having range 0⁰ C to 120⁰ C, 100 mm dial type . (f) Thermometer pocket with thermometer dial size 100 mm dia (g) Drain valve with threaded adapter(h) Sampling valve(j) Cover lifting eyes (k) Jacking pads, handling and lifting lugs (l) Rollers type four No. Wheels (m) Rating plate and terminal marking plate (n) cable end box on HT and LT side (o) Hand hole of sufficient size to assess the interior of the tank(p) First filling of transformer oil. Note: Contractor shall make necessary arrangements for factory inspection for Representative of Accepting Officer to witness Routine tests as Per IS:1180. The cost of testing of transformer shall be deemed to be included in the unit rate quoted.
Supply, installation, testing and commissioning step down transformer outdoor type, plinth mounted, HT 11 KV , 3 Phase 433 Volts, 4 wire, 50 HZ Delta /Star connected, vector group DYN -11 double copper wound , ONAN , on load tap changing facility on HT side to vary secondary voltage of + 7.5% in steps of 2.5%, continuous rating of capacity 630 KVA including bushing on HT and cable end box on LT side. The transformer shall conforming to IS-1180 Part 1 : 2014 and min BEE 3 level certified complete with all standard fittings and accessories, gauges, first filling of transformer oil etc complete including suitable platform of size and design as per manufacturer recommendations. (a) Oil conservator with filling hole and cap drain valve and oil level gauge (b) Silica gel breather with connecting pipe, first fill of dehydrating agent (c) Explosion relief mounted on tank with double diaphragm and equalizer pipe connected to conservator air spoon (Pressure release valve)(d) Air release plug (e) Oil temperature indicator (gauge) having range 0⁰ C to 120⁰ C, 100 mm dial type(f) Thermometer pocket with thermometer dial size 100 mm dia(g)Drain valve with threaded adapter(h) Sampling valve (j) Cover lifting eyes (k) Jacking pads, handling and lifting lugs(l) Rollers type four No. Wheels(m) Rating plate and terminal marking plate(n) Cable end box on HT & LT side (o) Hand hole of sufficient size to assess the interior of the tank(p) First filling of transformer oil (q) Platform constructed with PCC/Brick work and finished with cement mortar of size and design as per manufacturer recommendations. Note: Contractor shall make necessary arrangements for factory inspection for Representative of Accepting Officer to witness Routine tests as Per IS:1180. The cost of testing of transformer shall be deemed to be included in the unit rate quoted.
Supply, install, testing and commissioning 1:1 Isolation Transformer Indoor type minimum IP 23 enclosure, 415 volts at no load AC 3 phase 50 Hz capacity 160 KVA, core type double copper wound ONAN cooled oil immersed delta connected on primary side and star connected on secondary side in accordance with vector symbol DYN-11 (vector group) with neutral brought out on secondary side (LV side) efficiency >98% and having tapping at +5% in steps of +1% by means of off circuit tap link board. The maximum temperature rise 115⁰ Celsius by winding resistance method after continuous full load on an ambient temparature of 50⁰ Celsius. The transformer shall confirm to IS: 1180: 2014 and shall comprise of the following:- (a) Rating and diagram plate. (b) Two earthing terminals in two side. (c) Lifting lugs (d) Off circuit link board. (e) Base channel with Bi- directional Rollers. (f) Danger board (g) 100 mm dial type thermometer. (h) Cable entry boxes etc complete all as specified and directed.
Supply, install, testing and commissioning 1:1 Isolation Transformer Indoor type (minimum) IP 23 enclosure, 415 volts at no load AC 3 phase 50 Hz capacity 630 KVA, core type double copper wound ONAN cooled oil immersed delta connected on primary side and star connected on secondary side in accordance with vector symbol DYN-11 (vector group) with neutral brought out on secondary side (LV side) efficiency >98% and having tapping at +5% in steps of +1% by means of off circuit tap link board. The maximum temperature rise 115⁰ Celsius by winding resistance method after continuous full load on an ambient temp of 50⁰ Celsius. The transformer shall confirm to IS: 1180: 2014 and shall comprise of the following:- (a) Rating and diagram plate. (b) Two earthing terminals in two side. (c) Lifting lugs (d) Off circuit link board. (e) Base channel with Bi- directional Rollers. (f) Danger board (g) Thermometer with electronic display (h) Cable entry boxes etc complete as required.
S & F synthetic rubber insulated mats for voltage upto 33 KV for electrical purpose as per IS-15652-2006, (superseding IS-5424) suitable for electrical shock safety of size 1.0 M x 2.0 M x 3.0 mm thick all as specified & directed.
M&L for Earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to copper strip of size 25 x 3mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore medium grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, with RCC cover 40 mm thick 1;2:4, Type B0 (Using 12.5 mm graded crushed stone aggregate) reinforced with 8mm dia TMT bars @75 C/C both ways with MS handle 8mm dia and angle iron 40x40x3mm frame and chamber of PCC 1:3:6, type C-1 (Using 20 mm graded crushed stone aggregate), including earth work in any type of soil, removal of surplus soil to a distance not exceeding 50m, and connecting, testing and marking building numbers and writing test results on a 3.00 mm thick painted mild steel earth pit marking plate (200 mm x 100 mm) duly welded with a 450 mm long 10 mm dia round MS rod fixed with the earth pit chamber by grouting complete all as shown on electric plate No. 03 of SSR-2009 Part-I complete all as directed. Notes: (a) The unit rate quoted is deemed to be inclusive of cost of Earth lead & protection pipes length upto & including 7.50 metre (b) Earth filling shall be done by approved soil (c) Soil should be free from stone, boulders, aggregate, gravels etc.
Supply, installation, testing and commissioning of back up power supply with 36 volts DC low maintenance type chargeable battery of 18 cell of 02 volts , 40 Amps hour each including battery charger set having float cum boost charging facility suitable for 36 Volts battery Bank of 40 AH each, and control equipment of suitable size in sheet steel cabinet of 2 mm thick floor mounted for input 230 volts (+)(-)10 volt single phase, 50 Hz AC complete for 11 KV VCB Breaker panel with complete control wiring for connecting the DC tripping system to relays wiring shall be copper conductor of single core and size not less than 2.5 Sqmm running in PVC conduit, including stand for mounting of batteries in rack formation, made up of slotted angle iron frame complete all as specified & directed.
PROTECTION (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency (iv) Single phase Prevention (v) Spike and surge protection (vi) Earth Fault protection. INDICATOR DIGITAL :- (i) Power indicator (ii) Voltage indicator (iii) Frequency Meter (iv) Power Factor indicator (v) Ammeter, Temperature Meter, Digital Ammeter& Digital voltmeter (vi) Phase sequence indicator (vii) Oil level indicator
PROTECTION (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency (iv) Single phase Prevention (v) Spike and surge protection (vi) Earth Fault protection. INDICATOR DIGITAL:- (i) Power indicator (ii) Voltage indicator (iii) Frequency Meter (iv) Power Factor indicator (v) Ammeter, Temperature Meter, Digital Ammeter& Digital voltmeter for input and output side measurement (vi) Phase sequence indicator (vii)Oil level indicator
Supply, install, testing and commissioning CPRI type tested, factory made, totally enclosed, IP 54 dust, weather and vermin proof, CRCA sheet indoor LT Panel for 415V, 3 phase 4 wire, 50 Hz AC system with TPN tinned copper bus bar of rating 1.5 times that of controlling MCCB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar, general construction confirming to IS-8623/93, having bottom base channel of mild steel section not less than 75mm x 75 mm x 5 mm , entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size ( minimum 1.5 Sqmm) PVC insulated copper conductor cable , cable alleys(ACB Cable alley should be sizeable enough to accommodate multi core control cables for remote operations), cable gland plates in two half including LED indicating lamp for all phases and , mounted on suitable PCC foundation for the complete panel base with following detailed specification, control and accessories complete(LT Panel No. 01 for Sub Station No. 01) :-
Supply, erection, testing and commissioning of BBT of 1250 Amp TPN, copper air insulated compact BBT with copper earthing including bends, flange, flat elbow, end plug, interconnection adaptor box between LT panels with BBT (Between LT panels of 630 KVA outdoor Transformer, 630 KVA DG set, 630 KVA stabilizer , 630 KVA Isolation transformer with BBT installed at Substation No. 01) and including required canopy for outdoor BBT portion complete all as specified and directed Note:- Any other parts/items not specified above but the same are essential for completion of BBT system shall be considered in unit rate quoted.
Supply, erection, testing and commissioning of BBT of 400 Amp TPN, copper air Insulated compact BBT with copper earthing including bends, flange, flat elbow, end plug, interconnection adaptor box between LT panels with BBT (between LT panels of 160 KVA indoor Transformer, 160 KVA DG set, 160 KVA stabilizer , 160 KVA Isolation transformer with BBT installed at Sub station No 02) complete all as specified and directed Note:- Any other parts/items not specified above but the same are essential for completion of BBT system shall be considered in unit rate quoted.
Supply and erection of steel tubular pole swaged type 410-SP 31 (LT 9.00 M long pole) complete confirming to IS: 2713 complete with MS base plate of size 300 mm x 300 mm x 6 mm finial taper plug, bolts, nuts & screws complete all as specified including consisting of following works:- (a) Excavation in trenches not exceeding 1.5 M wide & 1.65 M deep for pole foundation & getting out in any type of soil , returning filling in the excavated soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 M complete all as specified and directed. (b) M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) in foundation filling and mass concrete for padding of size 1200x600x150 mm (thickness) cross section under pole foundation complete all as specified and directed. (c) M&L for providing PCC 1:3:6, type C-2 (using 20mm graded crushed stone aggregate) as in foundation, filling and mass concrete for pole of size 1200x600x1500 mm complete all as specified and directed (d) M&L for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminum paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block(e) M&L for writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole complete all as specified and directed (f) Painting of coping with 02 coats of cement based paint over one coat of cement primer all as directed(g) M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of size 600x600 mm above GL 300 mm height. Note : Manufacture's test certificate for poles shall be produced by contractor before execution work.
S&F LED Street light fitting 70 watt, with surge protection 4KV inbuilt in driver and minimum 10 KV separate, IP66 having Pressure die cast aluminium housing with heat resistant toughened glass, individual LED lenses complete and suitable for mounted on 32/40 mm dia pipe/ pole complete all as specified & directed. Note :- (a) The driver should be potted anti-vibration type, IP66 should sustain 440 volt for 2-4 hrs (b) LM-79 and LM-80 test report with 50000 glowing hrs LED life from NABL lab shall be provided (c) CRI (Colour Rendering Index of fixture shall be greater than 70 (d) CCT ( Colour correlated Temperature) of fixture shall be ± 300K (v) system lumen efficiency shall be > 100 lumen/Watt.
S&F new pole mounted thermoplastic cable junction box for street light 4-5 module with IP-65 protection, halogen free and weather proof with metric knockouts for cable entry for outdoor installation of approximate size 126x288x111 mm with front door opening system including terminals for one incoming and two outgoing cables of size 10 Sqmm, 4 core, one MCB SP 3 to 6 Amps, 240V AC with mounting clamp of flat iron, nuts, bolt and washers complete all as specified and directed.
M&L for providing twin core PVC insulated sheathed(heavy duty) unarmoured aluminium conductor cable (for phase and neutral) of size 2.50 Sqmm for connection drawing through pole or GI brackets of street light fittings with junction box or OH conductor complete all as specified and directed.
S&F street light bracket (with two set of GI clamps of size 25 x 3 mm, nuts & bolts & washers) made out of 32 mm medium grade GI pipe bend to shape and with fixing arrangement duly welded all as directed, length of pipe should not be less than 1.5 mtrs complete all as specified & directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including providing HDPE pipe of 150 mm bore suitable for 0.4 mpa working pressure complete all as specified & directed
S&F of LED aviation light fitting , pressure die cast aluminum housing, recess mounted, round type, 230V, 7.5W capacity and making all electric connections with two core PVC insulated , PVC sheathed copper conductor flexible cable 24/0.2 mm complete all as specified and directed.
S&F UPS for 30 minute backup single phase AC input 160 to 260 V and output 230 ± 1% of capacity 2 KVA complete all as specified and directed.
S&F LLDPE Septic tank designed to carry sewage and sludge water with inbuilt up flow filter & media for 10 users including excavation in any type of soil, PCC 1:4:8, Type D2 (Using 40 mm graded crushed stone aggregate) below foundation, vent shaft, connection etc as per manufacturer's instructions complete all as specified and directed.
M&L for soakage well of size 1.20 m x 3.00 m, excavation in any type of soil, foundation in PCC 1:3:6, Type C-2 (Using 40 mm graded crushed stone aggregate), walls of honey combed masonry with top ring M-25 concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25 (Using 20 mm graded stone aggregate ) cover, interconnecting pipes of RCC complete filled with brick bats complete all as specified and directed. Note : Earth work excavation including returning, filling in and removal of surplus soil upto a distance of 50 M is deemed to be included in the unit rate quoted.
S&F 32 mm bore galvanized steel water tubing light grade including all necessary fittings fixed to walls/ poles with end sealed for cable protection complete all as specified and directed. Note : Suitable size and numbers of MS clamps, nuts, bolts & washers for fixing of pipe to pole shall be deemed to be included in quoted rates.
S&F 100 mm bore galvanized steel water tubing light grade including all necessary fittings fixed to walls/ poles laid in trenches/floors with end sealed for cable protection complete all as specified and directed. Note : Suitable size and numbers of MS clamps, nuts, bolts & washers for fixing of pipe to pole shall be deemed to be included in quoted rates.
Forming embankment including raising or lowering earth, spreading in layers not exceeding 30 cm thick ramming / rolling and finishing to required size shape etc not exceeding 1.5 m high from base soil by approved earth/soil obtained from outside MOD land including transportation complete all as specified & directed. Note: The unit rate quoted is deemed to inclusive of cost soil including transportation.
SAGGI ELECTRIC COMPANY
Sant Construction Co.
SHARDA CONSTRUCTIONS
United Sales Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .