Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC NO 9 1 2ND FLOOR NORTH WALL ROAD KONDITHOPE CHENNAI 600079 | CHENNAI | CHENNAI | TAMIL NADU | 600079 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹5.8 L+₹81,000 (16.1%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹6.2 L+₹1.1 L (22.0%)Rejected-AOC | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | Akash Engineering Associates (P) Ltd L1 | MNK ASSOCIATES L3 | VARSHA & CO L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & Erection of 16 mtr High Mast Tower of polygonal shape for asymmetric loading of upto eight luminaries for wind sped upto 180km/hr. The mast shall be made from steel grade of BSEN 10025 and should be in two sections (each of length 8375 mm or Top length 5470mm & Bottom length 10980mm) with the bottom section shall be of 4mm thick and top section of 3mm thick both the sections should be joined by telescopic slip joint. The Bottom dia should be of 410mm or more while top dia should of 150mm. The bottom section should have anti vandalism looking type door size of 1200mm*250mm. The mast Section should be fabricated for metal protections through hot dip galvanized and thickness of galvanization should be less than 86microns. The mast should be suppied with components including head frame 7 Pulley assembly, winch, Bracket, Lantern, carriage ring for, Luminaries 7 CG box mtg. Arms Resting Bracket guide, Ring, Compensating Disc, lightning arrestor, LED AOL, wire rope, Safety, Wire rope, D Suckle, Clamps, nuts & Bolts, Internal cable, foundation accessories, winchassembly with two drums with SWL 750KG, and internal power tool of 2HP with control panel. The size of Base plate diameter should be of 570mm or more thickness should be 25mm with suitable foundation Work, Supply and fixing of 200W LED Flood light fitting system made of pressure die cast aluminium housing with heat resistant toughened glass cover confirming to IP65. Separate compartment for LEDs & electronic driver with CCT of 4100K-6000K, PF>0.9. System efficacy>85. Operating voltage range of 140V to 270V with surge arrestor Minimum of 4 KV. Driver current is 750mA. THD < 10% umens package not less 100 Im/W for LED Source. Supply and delivery of 3 core 1.5sqmm Flexible cable with ISI mark. etc - 8 Nos; Supply and laying of 3.5 core x 25sqmm PVC armoured (Aluminium)L.T.U.G. cable as per Standard Specification | 1 | Nos | 5,04,000 ₹5,04,000 Lowest | 6,15,000 ₹6,15,000 | 5,85,000 ₹5,85,000 |
Tender Value
₹6 L
EMD Value
₹6,000
Closing Date
1 Jul 2025, 3:00 pmClosed
COMMISSIONER TIRUNELVELI
S.N.HIGH ROAD MAIN OFFICE TIRUNELVELI CORPORATION
Supplly and erection 16 Mtr Highmast light at Near Amma Unavagam in ward no.13
2025_MAWS_570986_1
10/2025-26/11
Open Tender
Electrical Works
Works
90 days
S.N.HIGH ROAD MAIN OFFICE TIRUNELVELI CORPORATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹6,000
4 Sept 2025
19 Jun 2025
1 Jul 2025
19 Jun 2025
1 Jul 2025
19 Jun 2025
Amount
Supply & Erection of 16 mtr High Mast Tower of polygonal shape for asymmetric loading of upto eight luminaries for wind sped upto 180km/hr. The mast shall be made from steel grade of BSEN 10025 and should be in two sections (each of length 8375 mm or Top length 5470mm & Bottom length 10980mm) with the bottom section shall be of 4mm thick and top section of 3mm thick both the sections should be joined by telescopic slip joint. The Bottom dia should be of 410mm or more while top dia should of 150mm. The bottom section should have anti vandalism looking type door size of 1200mm*250mm. The mast Section should be fabricated for metal protections through hot dip galvanized and thickness of galvanization should be less than 86microns. The mast should be suppied with components including head frame 7 Pulley assembly, winch, Bracket, Lantern, carriage ring for, Luminaries 7 CG box mtg. Arms Resting Bracket guide, Ring, Compensating Disc, lightning arrestor, LED AOL, wire rope, Safety, Wire rope, D Suckle, Clamps, nuts & Bolts, Internal cable, foundation accessories, winchassembly with two drums with SWL 750KG, and internal power tool of 2HP with control panel. The size of Base plate diameter should be of 570mm or more thickness should be 25mm with suitable foundation Work, Supply and fixing of 200W LED Flood light fitting system made of pressure die cast aluminium housing with heat resistant toughened glass cover confirming to IP65. Separate compartment for LEDs & electronic driver with CCT of 4100K-6000K, PF>0.9. System efficacy>85. Operating voltage range of 140V to 270V with surge arrestor Minimum of 4 KV. Driver current is 750mA. THD < 10% umens package not less 100 Im/W for LED Source. Supply and delivery of 3 core 1.5sqmm Flexible cable with ISI mark. etc - 8 Nos; Supply and laying of 3.5 core x 25sqmm PVC armoured (Aluminium)L.T.U.G. cable as per Standard Specification
VARSHA & CO (BID ID -1386628)
MNK ASSOCIATES (BID ID -1386676)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_682144.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .