Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.8 L+₹5,630 (0.34%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹17.9 L+₹1.1 L (6.77%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹18.4 L+₹1.7 L (9.98%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹19.1 L+₹2.3 L (14.0%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Nov 2023, 6:00 pmClosed
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School , Mhow - 453441
REPAIR MAINT OF PUMP SETS BORE WELL PUMP SETS STARTERS AND CLEANING OF UNDER GROUND SUMPS AND OH RESERVOIRS REJUVENATING THE BORE WELLS SETS AT VARIOUS LOCATION AND ALLIED WORKS UNDER GE MAINT INF SCHOOL MHOW
2023_MES_623099_1
8605/GE(MIS)/MHOW
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
INFANTRY SCHOOL MHOW
All as per Tender document
7 documents required · 7 mandatory
₹500
Garrison Engineer (Maint) Inf School
₹40,000
Yes
29 Nov 2023
13 Oct 2023
6 Nov 2023
13 Oct 2023
3 Nov 2023
27 Oct 2023
Amount
M&L for Cleaning of over head tank, (staging from 6 meter to 18 Meter) (inside) by scraping with hard steel wire brushes and descaling of over head tank (reservoir), brooming slit and other deposit from inner side (bottom of dome ) collecting and taking out the same with the help of manual labour and removing and deposited to a distance not exceeding 50 m all as directed and making OHR complete clean and washing properly with bleaching mixed water and applying two coats of thick quick drying lime wash on entire surface (inner) top and bottom including writing date of cleaning with white paint on black painted surface of back ground at two places and painting of inner steel ladder of tank with one coat of synthetic enamel paint including painting to external surface of existing pipes (washout, overflow, delivery and inlet lines as per colour code) and all types of valves in the perimeter of OHTs all as specified and directed by Engineer-in Charge for the following :-
Over Head tank of capacity 100000 Gallon
Over Head tank of capacity 60000 Gallon
Over Head tank of capacity 50000 Gallon
Over Head tank of capacity 40000 Gallon
Over Head tank of capacity 20000 Gallon
Over Head tank of capacity 10000 to 15000 Gallons
M&L for cleaning of UG Sump of capacity 15 lakh gallon by scraping with hard steel wire brushes and physical cleaning of sump after drain out the water using Pump sets/ manual/ washout valves etc, removing the deposits and other waste materials and taking out waste to a distance of not exec 50 Mtrs all as specified and directed including cleaning and washing properly with bleaching mixed water and applying two coat of thick quick drying lime wash on entire inner surface of the sump and writing the Date of cleaning with white paint on black back ground at minimum two places out side /top of sump and painting of steel ladder of tank with two coats of synthetic enamel paint including painting and rewriting of water level indicator with existing colour complete all as specified and directed by Engineer- in – charge.Note:- Necessary T & P and material for the Job shall be arranged by contractor and ensure uninterrupted water supply to feeding area.
All as per item no 2 above, but UG sump of capacity of 50000 Gallons
M & L for cleaning of Flocculator and intake and outlet channel (inside) by scraping with the help of shovels, hard brushes and physical cleaning of surface by descaling/brooming silt and sludge and other scales from inner side ( bottom of dome) collecting and taking the same out with help of manual labour and deposited to a distance not exceeding 50 m all as directed and making the tank/channel complete clean including washing the inner surface properly with bleaching powder mixed water and painting with two coats of food grade paint over a coat of primer on entire surface (inner) including writing date of cleaning with white paint on black back ground at two places and painting with epoxy to the inner steel structure, racker arm and rotating plate form, motors , gear assy, hand rail and other connected structure all as specified and directed by Engineer-in-charge.
M&L for dismantling the electric induction motor 415 volts AC 3 Phase, capacity 75 HP to 100 HP, 440 V, 50Cycle of any make and type from the foundation and pump after disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repair/rewinding, strip opening the motor and removing of defective burnt winding, rewinding the motor after cleaning the rotor and stator with super enamelled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class ‘B’ varnish for insulation, reassembling the complete motor and re-fixing at the existing site with electric cable connection, earthing, proper alignment with pump and testing the motor on full load at site after coupling the pump for its serviceability up to entire satisfaction of Engineer-in-charge. Note :- (i) Super enamelled copper winding wire shall be measured and paid separately under appropriate item of this BOQ as supply only. (ii) Necessary T & P/ vehicles shall be arranged by the contractor and quoted rates ahll be inclusive of above provision.
All as per srl item No. 5 here-in-before but electric motor of capacity 15 HP to 50 HP.
M&L for disconnecting the Centrifugal pumps of capacity 75 HP to 100 HP of any make and model from motor and all water connections and removing/taking up from foundation, taking to respective (original pump manufacturer) authorised dealer workshop for repair/strip opening and repairing of pumping sets by changing the defective/unserviceable parts such as bearing, shaft, impeller, bush, Gland plate etc. complete and reassembling including oiling, greasing replacement of worn out nuts, bolts, gasket etc, and re-fixing in its original position at site, making all connections, commissioning and testing for smooth and noise free operation etc complete all as specified and as directed by Engineer-in-Charge. Notes :- (i). Ball bearing, shaft, impeller, bush, Gland plate & stuffing box packing, Cooling tube with Banjo nut, O ring, Shoulder ring , Gasket Packing, Vent valve, Gland rope and Set of rubber oil seal etc shall be replaced if required and the same shall be measured and paid separately under relevant item of BOQ as supply only. (ii) Necessary T & P/vehicles shall be arranged by the contractor and the quoted rates shall be inclusive of above provision.
All as per srl Item No. 07 here-in-before but pumping sets of capacity 15 HP to 50 HP.
M&L for lifting the defective open well submersible pumping set of capacity upto 10 HP complete after disconnecting electric cable connection for checking and repair and winding of open well submersible electric motor upto 10 HP by using PVC insulated copper conductor winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class ‘B’ varnish for insulation, reassembling the complete submersible motor pump and testing including reconnecting the electric cable connection complete all as directed by Engineer-in-Charge. Note :- (i) Super enamelled copper winding wire shall be measured and paid separately under appropriate item of this BOQ as supply only. (ii) Necessary T & P/vehicles shall be arranged by the contractor and the quoted rates shall be inclusive of above provision. (iii) The rates of repairing of pump, jointing and joining materials shall deemed to be included in the quoted rate.
M&L for lifting the defective bore well submersible pumping set of capacity upto 15 HP complete after disconnecting electric cable connection for checking and repair and winding of bore well submersible electric motor upto 15 HP by using PVC insulated copper conductor winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class ‘B’ varnish for insulation, reassembling the complete submersible motor pump and testing including removing dismantling of GI pipe 40mm to 80mm dia flanged/socket with electrical cable and lowering back the same including connecting GI pipes / cable etc after ,dismantling the pump set completely if required for replacement of Unserviceable /worn out parts/cable/pipe and assembling the same and servicing/ testing , complete all as directed by Engineer-in-Charge. Note :- (i) Super enamelled copper winding wire shall be measured and paid separately under appropriate item of this BOQ as supply only. (ii) Neccessary T & P/vehicles shall be arranged by the contractor and the quoted rate shall be inclusive of above provision. (iii) The rate of repairing of pump, jointing and joining materials shall deemed to be included in the quoted rate. (iv) GI Pipe and cable if replacement required shall be measured and paid separately under appropriate items of this BOQ.
Supply only in repair pump side Ball Bearing for Centrifugal Pump Set upto 30 HP as per existing make.
Supply only in repair of pump side Ball Bearing for 50 HP Centrifugal Pump Set as per existing make.
Supply only in repair of pump side Ball Bearing for 75 HP Centrifugal Pump Set as per existing make.
Supply only in repair of pump side Ball Bearing for 100 HP Centrifugal Pump Set as per existing make.
Supply only in repair of motor side Ball Bearing for 30 HP Centrifugal Pump Set as per existing make.
Supply only in repair of motor side Ball Bearing for 50 HP Centrifugal Pump Set as per existing make.
Supply only in repair of motor side Ball Bearing for 75 HP Centrifugal Pump Set as per existing make.
Supply only in repair of motor side Ball Bearing for 100 HP Centrifugal Pump Set as per existing make.
Supply only in repair,of Brass Impeller for Centrifugal Pump Set capacity 75 to 100 HP as per existing make.
Supply only in repair of C-40 Carbon steel shaft high tensile strength with key suitable for pump set of capacity 75 to 100 HP Make:- Kirloskar
Supply only in repair, of Shaft Sleeve Suitable for 30 to 50 HP Centrifugal Pump Set as per existing make.
Supply only in repair, of Shaft Sleeve Suitable for 75 to 100 HP Centrifugal Pump Set as per existing make.
Supply only in repair of oil seal suitable for Pump set upto Centrifugal Pump Sets upto 100 HP as per existing make.
Supply only in repair, of Gland Plate with complete Nut & Bolt suitable for Centrifugal Pump Sets 75 to 100 HP as per existing make.
Supply only in repair, of Lantern Ring suitable for Centrifugal Pump Sets 75 HP to 100 HP as per existing make.
Supply only in repair, of Coupling Set Suitable for centrifugal Pump Sets upto 100 HP as per existing make.
Supply only in repair set of rubber gasket packing suitable for Centrifugal Pump Set 75 to 100 HP.
Supply only in repair set of O rings suitable for Centrifugal Pump Set 75 to 100 HP.
Supply only in repair set of cooling tube with banjo nut suitable for Centrifugal Pump Set 75 to 100 HP.
Supply only in repair vent Valve made of Nylon suitable for Centrifugal Pump Set 75 to 100 HP.
Supply only in repair shoulder ring made of CI suitable for Centrifugal Pump Set 75 to 100 HP.
Supply only in repair nuts, Bolts & washers of appropriate size suitable for 75 to 100 HP centrifugal pumps.
Supply only in repair set of Keys made of material C-40 suitable for 75 to 100 HP centrifugal pumps.
Supply only in repair Gland rope packing suitable for Centrifugal pump sets upto 10 HP to 100 HP of make : Champion complete all as specified and directed.
Supply only in repair, of Super enamelled copper winding wire for rewinding the electric motors
S&F in repair of DOL starter suitable for 5 to 15 HP, 3 phase electric motor, workable at 415 Volts, 50 Hz , AC supply, with suitable over load relay , power contactor, protection relay for earth fault, over voltage, under voltage complete all as specified and directed.
Supply, fixing, laying & jointing galvanised iron water tubes 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, check nuts, caps, plugs etc. laid in trenches, lowering in bore wells etc. and testing complete all as specified and directed of 50 mm bore dia.
S&F in replacement of single phase preventer suitable for the 3 phase pump set of any capacity complete all as specified and directed.
S&F in replacement 3 pole contactor with 220/440 volt coil suitable for following starter:- complete all as specified and directed.
Supply and fix in repairs of MCCB , 415 Volts with neutral link including cable lugs all as specified and directed of following Sizes; complete all as specified and directed.
160 Amps adjustable ,3 Pole ,25 KA
200 Amps adjustable ,3 Pole ,25 KA
400 Amps adjustable ,3 Pole ,35 KA
160 Amps adjustable ,4 Pole ,25 KA
200 Amps adjustable ,4 Pole ,25 KA
400 Amps adjustable ,4 Pole ,35KA
S&F in replacement of Pneumatic Timer block suitable for mounting on contactors of 9A- 630A for star delta starter of any capacity and time delay as per existing delay timing complete all as specified and directed.
S&F in replacement of bimetal over load relay complete all as specified and directed.
S&F in replacement of V belt , Heat + Oil Resistant, antistatic belt suitable for reduction gear complete all as specified and directed.
Supply and fix obstruction less and maintenance free electromagnetic flow meter with accuracy +0.5% of full scale to with stand media pressure 20kg/cm2 & media temp -0-1200 C, MOC pipe -SS 304 (no magnetic & without painting), Electrodes - SS 316/SS 316 L/hastalloy C inner lining -PTFE/ Hard rubber ends of size of 150 mm bore complete all as specified and directed. Make : Technofriends Electronics or other equivalent as approved by GE.
4-20mA Transmitter Specifications Type - Integral/ remote mounting , Enclosure -Aluminium die-cast for amplifier/ Transmitter, Dimensions of head mount 100 mm (L) x 160 mm (W) x 80 mm (D), Remote Mount 100 mm (L) x 160 mm (W) x 80 mm (D), Cable entries - 3 Nos, for remote / integral transmitter, Cable glands - PG - 7 (Standard), Power supply - 110 V /220 V AC 50Hz Single phase, remote for mobile monitoring, Input Micro-volt signal proportional to flow rate from flow tube, Outputs - 4-20mA dc in max. 110 Ohms - Proportional ( 0 - 100% flow rate), Flow rate unit - M3/hr, LPH. LPM & LPS, Local Display - (a) 4 digit 7 segment LED display (with unit indications), (b) 8 digit 7 segment LED display for totalized quantity (with unit indication), Flow velocity - (a) 1.25 m/s, (b) 2.5 m/s, (c) 5.0 m/s, (d) 10.0 m/s, & (a) V= 0.3 m/s (b) V=1m/s, (c) V = 12 m/s. Accuracy ± 1% (10 % to 90% of calibrated range in ref.condition), ref condition - Power supply nominal ±10%, temperature 27º C ± 2ºC, Repeatability ± 0.2% of reading with IP -65 protection.
S&F in repair butterfly valves lever operated having epoxy coated cast iron body, PN 1.6, ISI marked SGI disc with integral seat of nitrle rubber of the following sizes:-
80 mm bore
100 mm bore
150mm bore
200 mm bore
250 mm bore
300 mm bore
400 mm bore
S&F in repairs CI Air release valve of size 40 mm suitable for pipeline upto 400 mm dia with single air outlet ball type CI pipe through having flanged end joints with and including necessary rubber gasket, nuts, bolts, washers etc along with CI reducer connected with sluice valve having gun metal spindle and hand wheel complete all as specified
S&F in repair Sluice valves cast iron body, double flanged, ISI marked (IS-14846), heavy duty, class PN-1.6 gun metal, with non rising spindle of solid forged bronze and operating handle, including rubber gaskets, nuts, bolts, washers all as specified and as directed complete of following sizes: -
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
S&F in repais copper lugs of 50 sqmm for motor terminal plate
S&F in repais PVC/ FRP terminal plates suitable for 75/100 HP 3 phase induction motor including provision of GI nut bolt and washers of appropriate size as per existing make and model all as specified
MODI CORPORATION
Vending Services And Solutions
Sameer Auto Engineers
ENVIRO TECH SERVICES
M/S Sunshine Construction
S.S. Engineers
Jamna Constructions
M/S GARG CONSTRUCTION
NIDHI CONSTRUCTION
Auto Traders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .