CE/TTPS/SE/ES
Superintending Engineer-Electrical Systems- Tuticorin Thermal Power Station-Tuticorin
Fault attending in Boiler auxiliary motors and modules valve motor soot blower motor and preventive maintenance of Ash Silo Transformer A and B of Unit IV and V from the date of commencement of work upto 31 03 2022
2021_EB_210940_1
CE/TTPS/ SE/ES /230 /2021-22
Open Tender
Electrical Works
Item Rate
180 days
TTPS
As per BQR conditions in NIT
6 documents required · 6 mandatory
₹0
₹2,300
Yes
23 Feb 2022
4 Oct 2021
12 Oct 2021
4 Oct 2021
11 Oct 2021
4 Oct 2021
Maintenance of L.T. Boiler auxiliary motor: Determination of power cable, removal of LT Boiler auxiliary motor from the bed, measurement of IR values and winding resistance values of the motor, field coil and tacho coil in the RC feeder motor and fault rectification by dismantling the motor and replacing the failed and worn out parts reassembling and refixing the motor on the bed checking complete alignment, reconnecting the power cable and conducting trial run satisfactorily. (Including cost of consumables and hire charges for T&P)
Maintenance of L.T. Boiler valve motor / Soot blower motor: Determination of power cable, removal of valve motor from the actuator, measurement of IR values and winding resistance values in the motor, and fault rectification by dismantling the motor and replacing the failed and worn out parts reassembling and refixing the motor on the actuator reconnecting the power cable and conducting trial run satisfactorily. (Including cost of consumables and hire charges for T&P) Valve motor = 12 Nos. Soot blower motor = 24 Nos. Total 36 Nos.
Rectification of LT Module: Inspection of module during fault and rectification of the fault by tracing the control circuit, checking of tightness, replacing failed parts complete checking the healthiness of module and outgoing cable in the BMCC, BVMCC and Soot blower modules.
Maintenance of Ash Silo Transformer: Removal of Terminal box cover, measurement of IR values checking tightness, inspection of cables, breather, explosion vent, oil level and collecting of oil sample for BDV test and complete cleaning of Ash silo Transformer A & B. (Including cost of consumables and hire charges for T&P)
S. MURUGAN CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .