Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹9.8 L+₹33,210 (3.50%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹9.9 L+₹38,130 (4.01%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹10.1 L+₹62,628.60 (6.59%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE | |
| 5 | L5₹10.9 L+₹1.4 L (15.1%)Rejected-Finance WARD NO 07 WARD NO 07 THANA PARA NALHATI BIRBHUM WEST BENGAL 731243 | BIRBHUM | WEST BENGAL | 731243 | L5 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
Closing Date
13 Jan 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF SINGARSI
AGE I AF SINGARSI
Repair Maint of DG Sets of under Different capacities at AF Stn Singarsi under AGE I AF Singarsi
2021_MES_480271_3
C/8537/E8
Open Tender
Civil Works
Item Rate
270 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹18,000
Yes
AGE I AF SINGARSI
Yes
21 Jan 2022
29 Dec 2021
14 Jan 2022
29 Dec 2021
13 Jan 2022
30 Dec 2021
30 days
Amount
Comprehensive maintenance including periodical servicing & regular inspection of 400 KVA /320 KVA DG Sets (Make :(i) KOEL (ii) Cotton Greaves(iii) Kirloskar, Location : Sub Stn -05, Booster ) by the authorised technician / service engineer of OEM or their authorised service dealer, checking the mechanical and electrical healthyness of the diesel engine and alternator, routine servicing of the DG set including cleaning & replacement of air filter, changing of fuel filter and lubracating oil filter,draining out unserviceable engine oil from engine and refill with new engine oil, cleaning all sludge/deposits in the oil sump and removed off the site as per schedule, minor adjustment of control parameters, tracing out the defects and replacement of defective spares including taking out the old unserviceable one to keep the DG set healthy and serviceable state as specified and directed by Engr-in-charge at site. Notes :- (a) Spares , engine oil will be measured and paid separastely as applicable. (a) Apart from these routine servicings, major repair/replacement if any as decided by Engr-in-Charge will be measured and paid separately available within the scope of this schedule.
Supply only "V" bend clamp,Make : ,same as per existing of 400 KVA
Supply only Jupiter T-Bolt clamp S/F 83 mm O.D. same as per existing of 400 KVA
Supply only lubricating oil pressure sender VDO,Make : same as per existing of 400 KVA
Supply only Preline filter (without water level sensor), As per Existing of 400 KVA
Supply only Schwitzer Turbo master (Turbo charger) (S 200/80H27BECRM/74DA7-0.85A/R-VTE), As per Existing 400 KVA DG sets
Supply only Flange for turbocharger oil drain,Make : same as per existing of 400/320 KVA
Supply only Belt 'V' section (Bx58 pitch length 1520),Make : As per Existing of 400/320 KVA
Supply only Belt 'V' section (Ax56),Make : As per Existing of 400/320 KVA
Supply only Fuel filter assembly (Consisting of fuel filter & mounting bracket) of 400 /320KVA
Supply only Air filter cleaner primary element for 400 KVA DG set, As per existing DGs
Supply only Air filter cleaner safety element for 400 KVA DG set, As per existing DGs
Supply only lubricating Oil filter element for 400 KVA DG set, As per existing DGs
Supply only Fuel filter and cartridge for 400 KVA DG set, Make : As per existing DGs
Supply only Preline filter cartridge for 400 KVA DG set, Make :As per existing DGs
Supply only 'V' Belt suitable for 400 KVA DG Set same as per existing
Supply only Thermostat element for 400 KVA DG Set, existing make
Supply only AVR suitable for KOEL Alternator Model of 400/320 KVA DG set
Supply only Fuel pipe for 400/320 KVA DG set as per sample.
Supply only Rubber coupling for 400 /320 KVA DG set as per sample.
Supply only Digital Ammeter for 400 /320 KVA DG set
Supply only indicator light for 400 /320 KVA DG set
Supply only Digital Voltmeter for 400 /320 KVA DG set
Supply only Radiator cap for 400 /320 KVA DG set
Supply only door locks suitable for 400 /320 KVA DG set
Supply only door hinges suitable for 400 /320 KVA DG set
All as per item No 01 here-in-before but capacity 160 KVAs DG Set (Make : KOEL, Location : Booster & DAM Pump House)
Supply only Air Cleaner Primary element for 160 KVA DG set, Make : KOEL
Supply only Air Cleaner Safety element for 160 KVA DG Set, Make : KOEL
Supply only Fuel filter pre for 160 KVA DG set, Make : KOEL
Supply only Fuel filter micro for 160 KVA DG set, Make : KOEL
Supply only Fuel pipe for 160 KVA DG set as per sample.
Supply only spin on filter for lubricating oil for 160 KVA DG set, Make : KOEL
Supply only 'V' Belt suitable for 160 KVA DG Set same as per existing
Supply only assemble of Stop solenoid for 160 KVA DG set,existing make of DG set Make : KOEL
Supply only Relay board for 160 KVA DG set,existing make of DG set Make : KOEL
Supply only AVR suitable for Kirloskar Alternator of 160 KVA DG set
Supply only Thermostat element for 160 KVA DG set for Kirloskar Green, Make : ISI marked.
Supply only lubricating oil pressure (LOP) Sender for 160 KVA DG set, Make : KOEL
Supply only indicator light for 160 KVA DG set as per sample.(Make:L&T/Siemens/GE)
Supply only Digital Ammeter for 160 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Digital Voltmeter for 160 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Radiator cap for 160 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Rubber coupling for 160 KVA DG set as per sample.
All as per item No 01 here-in-before but capacity 62.5 KVA DG Set (Make : KOEL, Location : Pump House No-04)
Supply only RH lock with catcher up to capacity of 62.5 KVA
Supply only Fuel filter pre for 62.5 KVA DG set, Make : KOEL
Supply only Fuel filter micro for 62.5 KVA DG set, Make : KOEL
Supply only spin on filter for lubricating oil for 62.5 KVA DG set, Make : KOEL
Supply only 'V' Belt suitable for 62.5 KVA DG Set same as per existing
Supply only Fuel pipe for 62.5 KVA DG set as per sample.
Supply only Rubber coupling for 62.5 KVA DG set as per sample.
Supply only indicator light for 62.5 KVA DG set as per sample.(Make:L&T/Siemens/GE)
Supply only door hinges suitable for 62.5 KVA DG set as per sample.
Supply only Digital Ammeter for 62.50 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Digital Voltmeter for 62.50 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Radiator cap for 62.50 KVA DG set as per sample.(Make:L&T/Havells/AE)
All as per item No 01 here-in-before but capacity 30 KVA DG Set (Make : Ashok Leylend, Location : SAG Pakur)
Supply only 'V' Belt suitable for 30 KVA DG Set same as per existing
Supply only Engine Control Panel with EMS unit for 30 KVA DG Set.
Supply only Fuel Filter element set for 30 KVA Ashok Layland DG Set.
Supply only Lub Oil Filter element set for 30 KVA Ashok Layland DG Set.
Supply only Air Cleaner element set for 30 KVA Ashok Layland DG Set.
Supply only Fuel pipe for 30 KVA DG set as per sample.
Supply only Rubber coupling for 30 KVA DG set as per sample.
Supply only indicator light for 30 KVA DG set as per sample.(Make:L&T/Siemens/GE)
Supply only Digital Ammeter for 30 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Digital Voltmeter for 30 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Radiator cap for 30 KVA DG set as per sample.(Make:L&T/Havells/AE)
Supply only Engine Oil, 15W 40, Make : Castrol/Speed/HP/Shell/Viscol/Veedol.
Supply only Engine Oil, 20W 40 Make : Castrol/Speed/HP/Shell/Viscol/Veedol.
Supply only Coolant for radiator Castrol/Speed/HP/Shell/Veedol.
Supply only Battery 12 volts 180 AH heavy duty suitable for DG Set operation. Make: Exide or equivalent as approved.
Taking down the radiator of 400 KVA DG Sets from engine, transportation to the workshop, dismantling the radiator, repairing of top and bottom tank including necessary welding / brazing & making the radiator leak proof, cleaning the complete radiator internally with chemical agent (K Clean) and outside with Kerosene oil and high pressure water jet,filling of coolant including replacement of defective copper core, suction connection, main pipe, stud, stay, spacer, rubber hose (02 Nos) and assembling the radiator including replacement of all old rusted mild steel nuts, bolts washers & gasket sets and hose pipe asembly including transportation from wksp to original work site & fixing to the engine and testing complete.(Coolant for radiator will be measurd and paid separately)
Taking out self starter up to 24 volt from the 400 / 320/160/KVA DG Set, transportation to workshop opening/disconnecting all internal connection, cleaning the same taking out burnt coil, segrigation of serviceable parts for re-use, rewinding of coil with existing size of copper wire. Reassembling the same with replacement of of carbon brush 01 set, Beadix pinion 01 no, Half clutch assy 01 No, Field coil 01 No, solonoid switch 01 No., commutator 01 nos, fixing the self starter on the engine at site and testing complete all as directed by Engr-in-Charge.
Taking out self starter 12 volt from the 62.5 KVA / 30 KVA DG Set, transportation to workshop opening/disconnecting all internal connection, cleaning the same taking out burnt coil, segrigation of serviceable parts for re-use, rewinding of coil with existing size of copper wire. Reassembling the same with replacement of of carbon brush 01 set, Beadix pinion 01 no, Half clutch assy 01 No, Field coil 01 No, solonoid switch 01 No., commutator 01 nos, fixing the self starter on the engine at site and testing complete all as directed by Engr-in-Charge.
Taking out turbocharger from the 400 KVA DG Set, transportation to work shop for repair and dismantling the same, cleaning and carrying out thorough inspection of each components/spares segrigation of u/s & serviceable spares for reuse and decarbonising machine, cutting, grinding polishing etc and re-assembling of the turbocharger by replacement of turbocharger shaft, turbocharger kit and connected spare parts to match with the existing , refixing and testing as directed at site by Engineer in Charge.
All as per item above here-in-before but capacity 160 KVA DG Set
Supply and laying in replacement of following size XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor (multistranded), connected with , suitable cable gland and aluminium lugs of any size laid in trenches or passing through pipes including testing after laying, including taking up old UNSV cable complete of 240 Sqmm 3.5 Core, 1100 Volts grade size all as specified and directed by Engineer-in-Charge. Make : Universal/Plaza/Gloster/Havells/Nicco/CCI.
All as above but 10 Sqmm 4 core , 1100 volts grade
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in Hard/dense or any other type of soil for taking up or laying of cable all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms.
Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point.
Supply and laying new dry river sand laid in trenches 8cm below the cable and 15cm above the cable and punned to 18cm as cable cushioning and covering all as directed. Note:- Punned quntity will be measured paid at this item.
Supply and laying in replacement of brick well burnt locally available sub class 'B' laid over sand cushioning for cable protection in trenches width of brick perpendicullar to the length of cable including taking up of old UNSV bricks complete all as specified and directed by Engr-in-Charge.
S & F in replacement of GI tubing light grade 100mm nominal bore for cable protection fixed with clamps of M.S. Flat iron 25x3mm, GI nuts, bolts and washers to poles/under floor/under roads/alongwith walls including two coats of aluminium paint over a coat of red oxide primer on clamps complete including taking up of old UNSV GI tubing complete all as specified and directed by Engr-in-Charge.
Supply and fixing online Change over switch 600 Amps rated capacity , FN- TPN in SS enclosure , mounting on wall /Panel , including cable interlock top & bottom , cofirming to IEC 60947-3, IS/IEC 60947-3 of 50 Hz, 415 Volt as per following amps rated capacitycomplete with cable connection of existing DG set and Transformer as directed by Engr-in Charge . Make- L&T Cat part No. SK90491 or equiavelent.
Supply & Fix indoor end termination kit, heat shrinkable suitable for size 240 to 300 sqmm 3.5 core armourd XLPE cable all as directed by Engr-in -Charge.
Supply and fixing in replacement of PVC single core 25 sqmm FRLS PVC insulated copper conductor , Make : Havells /Polycab/Anchor or equiavalent
Supply only Copper lugs of size 50 mm
Supply only copper Battery terminal complete with nut , bolt and washer for fixing to existing batteries.
M&L for applying two coats of synthetic enamel spray painting to conopy diffirent capacity DG Sets of existing colour shade on surfaces of any description, exc. 10cm with or girth to external surface of DG sets by spray gun after necessary preparation of old surfaces complete all as specified and as directed by Engr-in-Charge. (Note:- Shade of paint to be approved by AGE(I).
M/S ASHA ENTERPRISE
M/S Subhadip Enterprise
M/S SINGH ENTERPRISE
M/S New Builders Corporation
LALAN SHARMA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .