Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹18.8 L+₹1.5 L (8.62%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate |
Tender Value
₹22.8 L
EMD Value
₹45,600
Closing Date
24 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Sachin H Chavan IDSE
GE NORTH BATHINDA MIL STN-151004
PROVN OF CERTAIN MINOR WORKS AND REV WORKS AREA UNDER AGE BR-V AND AGE E/M OFFICE OF GE NORTH BATHINDA AT BATHINDA MIL STN
2021_MES_462929_1
8936/NIT-43/21-22
Open Tender
Civil Works
Item Rate
150 days
GE NORTH BATHINDA MIL STN
E Class and category a i
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹45,600
Yes
14 Sept 2021
27 Jul 2021
26 Aug 2021
27 Jul 2021
24 Aug 2021
11 Aug 2021
27 Jul 2021 - 3 Aug 2021
60 days
Amount
SCHEDULE 'A' B/R Works
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil including cutting of grass, roots, bushes if any and filling of lower portion with soil obtained from cutting and dressing complete all as specified and as directed by Engineer-in-charge.
Surface dressing not exceeding 15cm deep in soft/ loose soil including cutting of grass, roots, bushes if any and filling of lower portion with soil obtained from cutting and excavation after sepration of grass, roots, bushes etc and dressing and removing from site all grass, roots and extra soil if any complete all as specified and as directed by Engineer-in-Charge.
Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Material and labour for hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:2:4), type B-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, sub base of sewage tank & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for 40 mm thick damp proof course in cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary form work and including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, complete all as specified and as directed by Engineer-in- charge. (Note :- WPC shall be measured & paid separately as Supply only)
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Form work to flat sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs, sides of chajjas etc and similar works rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge
Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed by Engineer-in-charge.
Material & labour for continuous brick edging (sub class ‘B’) with width equal to the width of brick laid dry on end vertically including necessary earth work, embedding bricks at depth as directed and removal of surplus soil complete all as specified. Note : Each row shall be measured and paid separately.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work in half brick thick wall using burnt clay bricks (sub class 'B' old size burnt clay bricks) straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in- charge.
Material and labour for mild steel TMT bars 10mm dia and above, cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose)
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Supply only water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
Material and labour for mild steel work tubular poles/post including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to latest relevant IS grade St-240 complete all as specified & directed by Engineer-in- charge.
Material and labour for mild steel framed work, framed/truss work made by using hollow square/rectangular/round pipe (ERW or induction butt welded tubes conforming to latest relevant IS), or other section like angle, tee, plate, distance pieces, cleats etc. and cut to shape, drilled and counter sunk for screw, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and fixed with angle cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, conforming to Gde Fe-410-W (Gde E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge. Note ;- Sketch of new truss design and steel section to be used shall be approved by Engineer-in-charge in writing before execution)
Supply and fixing Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick, any colour having tensile strength of 550 Mpa as in ridge (including cutting and bent to shape), roof covering, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing anodised aluminium snap grid frame work of size of grid 605 x605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 6mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 80 mm thick (M40 grade) precast interlocking tile/paving block factory casted (made by using PVC paver mould / Rubber paver moulds on Vibrating Table Machine) using grey cement and no pigment, shape haxagon / trigular / zigzag / I-shaped etc, as directed, prepolished & preglazed, specification as per relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over sand upto required thick layer and filling the interstices etc complete all as specified and as directed by the Engineer-in-Charge. Note : - (i) Sand for filling shall be measured & paid separately as Supply only but labour for spreding leveling shall be included in the unit rate of this item)
Supply only fine sand without silt (Fazilka/Zera or any other approved sources) for filling under interlocking tiles and the interstices etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in coping/packing around chequered tiles/interlocking tiles/PCC jalli & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for Glazed ceramic coloured tiles of size 300mmx 200mm / 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for machine cut 18 to 22 mm thick, Kota stone slab (size of slab not less than 550x550mm) as in flooring, laid over and including 20mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) and polishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut 18 to 22mm thick, Kota stone slab as in riser of steps, skirting, dado and on pillar, laid over and including 15mm thick bedding layer in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangular complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory made 125 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Material and labour for PCC (1:3:6) type C-0, using 12.5 mm graded aggregated as in back filling of chowkhats and for hold fast complete all as specified and as directed by Engineer-in-Charge
Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard wood with lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated (two panels as approved) and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8 and fitted to chowkhats, menbers shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item of BOQ.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out 5mm thick plain clour PVC sheet reinforced with MS square tube including painting of edges to match with sheet, all as specified & shown in relevant drawing of item No. 8095 in MES Schedule SSR-2020 (Part-II), fixed in opening complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory made solid core PVC door shutter 30mm thick (stiles) consisting of frame made out of MS tubes of 19mm gauge thickness and size of 19mmx19mm for stiles and for top and bottom rails 15mmx15mm. MS frame shall have a coat of red oxide primer of approved make and shall be covered with heat moulded plain colour PVC sheet, 'C' channel of size 30x50mm forming stiles and 5mm thick wide PVC sheet strip of 20mm width stuck inside with solvent cement for stiles, and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and 10mm (5x2mm) thick, 20mm thick PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive and an additional 5mm thick PVC strips of 20mm width is to be stuck on interior side of C channel using PVC solvent adhesive as per manufacturer's instructions, door to be fixed to frame with and including 3 Nos MS powder coated butt hinges of size 100mm long x 25mm wide and 2mm thick and fixing with 32mm long steel screws drilled suitable to pass through both the walls of the MS tube complete all as specified in SSR-2009 (Part-I, specifications) & shown in relevant drawing of item No. 8080 in SSR-2020 (Part-II, rates). The width of stiles & rails will be in proportion to the width of the door shutter as specified in SSR-2020 (Part-II). complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, without glazing bars (mosquito proof shutter) including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing, factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, suitable steel handle, steel peg stay, fixing lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply only 100mm long Mild steel butt hinges medium weight, cold rolled, complete all as specified & directed by Engineer-in-charge.
Supply & fixing 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing anodised aluminium handle cast type 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing mild steel pressed handle, oval type, stove enamelled black 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing mild steel barrel tower bolt stove enammelled black with bright, 200mm long complete all as specified & directed by Engineer-in-charge.
Supply & fixing mild steel sliding door bolts 300mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts washers, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel sliding door bolts 250mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts washers, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in- charge.
Supply and fixed 3mm thick sheet glass ordinary quality duly frosted, on one side, not exceeding 0.5sqm in each pane complete all as specified & directed by Engineer-in- charge.
Supply & fixing, 3mm thick figured glass pin head type in squares / retangular not exceeding 0.5sqm in each pane for steel or wooden doors/wondows including fixing material complete all as specified and as directed by Engineer-in- charge.
Supply & fixing galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified & directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed to wall with stack clamps (interval of 1m) made out of FI 50x5mm and 16mm dia round iron stay including nut bolt and jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, laid in trenches or in floor jointing with cement mortar complete all as specified and as directed by Engineer-in- charge.
Material & Labour for Stack clamps for 100mm dia of pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including PCC work, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) without oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 75mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) without oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) 'P' trap complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Cast iron floor trap 100mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Cast iron floor trap 75mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch fitted with oval access door as specified & directed by Engineer-in- charge.
Supply & fixing 75mm bore CI branch pieces single (equal or unequal), ordinary or inverted (Spigot or socket type) or with parallel branch fitted with oval access door as specified & directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron cowl complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) vent cowl suitable for 110mm bore PVC pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 150mm x 150mm size salt glazed stone ware gully traps, square or round mouthed, type 'P' complete all as specified and as directed by Engineer-in- charge.
Material and labour cutting into existing manholes/septic tank for connecting new drain upto 150mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round to 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required complete all as specified & directed by Engineer-in-charge.
Material and labour for cement concrete (1:4:8), type D2 using 40mm graded stone aggregate as in bed of drain pipe of size upto 150mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
Material and labour for 150mm bore (internal dia) salt glazed stone ware (SGSW) drain pipe, grade ‘A’, laid on concrete bed to required slope in trenches, jointing with packed spun yarn and in cement and sand mortar (1:1) and tested complete all as specified and directed by Engineer-in-Charge. (Note : Excavation, earrh work and concrete bed shall be measured and paid separately under appropriate item of BOQ.)
Supply & fixing vitreous China squatting pan 'Orissa' pattern white of size 580mmx440mm white with integral foot rests, excluding flushing cistern, flush pipe above floor but including PVC (SWR) 'P' trap 100/110mm bore and including setting the trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, including PVC flush pipe upto finished floor level, joints of flush pipe and trap make leakproof and testing upto entire satisfaction of Engineer-in-charge before filling concrete complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fixing vitreous china wash basin, white, flat back of size 550mm x 400mm, including 32mm chromium plated waste coupling and PVC waste pipe including bracket and cutting for and pinning in end of bracket or erecting including fixing only pillar tap (new or serviceable old pillar tap as per site condition ) complete all as specified and as directed by Engineer-in-Charge. (Note :- Pillar tap if required in replacement, shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply & fixing vitreous china urinal, bowl flat back size 465x355x265mm white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing vitreous china urinal, half stall type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar, complete all as specified & directed by Engineer-in-charge. Cat part no. USR-WHT-13261 of jaquar or equivalent make mentioned in Appendix 'A' of PSS-II
Supply and fixing MS chromium plated, soap tray approximate size 160mmx160mmx90mm, including fixing to wall with CP screws and PVC plug complete all as specified and directed by Engineer-in-Charge.
Supply and fixing bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply and fixing stop valve/angle valve cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply only ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply only gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 15mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply only gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Supply and fixing 32mm bore pipe Low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying three coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing newly plastered or concrete surface of wall by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for newly plastered of walls applying two coats of oil bound distemper (washable) over a coat of wall chalk whitening complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Supply and fixed pillar tap cast copper alloy with capstan head, chromium plated, fancy type, high pressure with or without letter 'Hot' or 'Cold' with long shank and fly nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
SCHEDULE 'A' ELECTRIFICATION WORKS
Material and labour for concealed Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.2mm thick sheet) concealed in wall, 3mm thick bakelite plastic laminated hylem sheet for mounting of switches/socket/regulator with brass screws & cup washers and covering, wiring for light /fan/ bell point controlled by one switch (on indipendent board), including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 104 but for one socket out let 5/6 Amps point controlled by one switch on same board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
All as per above Srl item No. 104 but for one socket out let 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed Point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and made out of 1.6mm thick sheet), 3mm thick bakelite plastic laminated hylem sheet for mounting of switches/socket with brass screws & cup washers and covering, wiring for one socket out let 15/16 Amps point controlled by one switch (on indipendent board), including provn of 2.5 Sqmm FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
Supply and fixing switch piano flush type, single pole one way, 6 Amp, 250 Volts AC, complete all as specified.
Supply and fixing socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, 250 Volts AC, complete all as specified.
Supply and fixing switch piano flush type, single pole one way,15/16 Amp, 250 Volts AC, complete all as specified.
Supply and fixing Socket outlet 2 in 1, 3 pin, 5/6 and 15/16 Amp flush type, 250 Volts AC, complete all as specified.
Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, 250 volts, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, 5/6Amps, 250 volts, batten fitting with LED bulb 9 watt complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stepped type (1-4/5), electronic Fan regulator (one module), 100-120 watt, 250 volts, fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (Laminated sheet shall be measured and paid in point wiring item of BOQ).
Supply and fixing Wall Mount retro LED 18/20 watt, batten decorative type, approx 4 feet long, pre wired including LED tube light 18/20W, 6000K, 100 lumens/watt with inbuilt driver complete fitting and all other accessories fitting arrangement including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector complete all as specified and as directed by Engineer-in-Charge. Make :- Cat Part No. LT8-20-865-2 and DMLN1LT8-16 of Crompton and BLRB18W and BLRB-DB118 of BAJAJ
Supply and fixing LED mirror light fiting 10 watt (100 lumens per watt), 6000K, complete fitting ready to use in all respect with lamp and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Sleek Pressure die cast aluminium housing/body, heat resistant clear glass, LED lens for wide beam, energy saving, IP65/66 protection, not less than 5700K, better optics for uniform distribution street/security light/ Roadway luminaire with high power LED 35 watt complete fitting with driver, LED strip and all other accessories etc, suitable for 40/32mm OD entry for direct mounting on pipe bracket, fixing on building and including brackets made out of GI tubing light grade 40mm dia, 2 metre long bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing with MS clamp (02 Nos) and nut bolts, including before fixing applying two coats of aluminium paint on bracket and clamp over a coat of red oxide primer, including making electric connection with using twin core copper cable of suitable size complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) TPN, 4 Way 433 V (8+12 modules), double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 08 Way 230/240V, double door, earth bar, 200 Amp rated copper bus bar and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 04 Way 230/240V, double door, earth bar, 200 Amp rated copper bus bar and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in provision of MCB, SPN, 40Amps, 10 KA 'C' curve 230 Volt AC, 50 HZ including necessary attachement MCB SPN, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in provision of MCB, SPN, 63Amps, 10 KA 'C' curve 230 Volt AC, 50 HZ including necessary attachement MCB SPN, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing MCB TPN 63 Amps 415 Volt AC, C curve, 4 module capacity not less than 10 KA complete all as specified.
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing exhaust fan 300 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Make - Usha / Bajaj / Khaitan / Orient / Crompton / Polar Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and hanging/fixing ceiling fan 1200 mm sweep in white/off white colour, 50watt, copper winding, 3 Blade, single phase, 230 volts 50 Hz double ball bearing, energy saver/energy-efficient, alongwith hanging rod (length as per site requirement or as directed by Engineer-in-charge), canopy (lower and upper), rubber real, nut bolts, lock pin etc. including making electrical connection with flexible round twin core multi strand copper cable suitable size complete all as specified and as directed by Engineer-in-Charge. Make and cat part :- Entrust 50 of Crompton / Energia of USHA / ES 50 of Havelles / Electra 50 of Bajaj Note :- (i) Srl Number of ceiling fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Ceiling fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
Supply and fixing electric water heater (Geyser), storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (Geyser Box) with a two pin and earth plug and socket complete with one single pole MCB of capacity 25 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
Supply and fixing recessed LED ceiling tile with wide light window for maximized glare free output suitable for 600x600mm and ceiling cutout 595x595mm modular grid/POP ceiling complete fitting with separate electronic driver and high brightness LEDs 36 W (100 lumens per watt), not less than 5700K including connecting electric connection, complete all as specified and as directed by Engineer-in-Charge. Make : Cat part No. LCTLRN-36-F0-CDL of Crompton / BZRSQL 36W GZ1 CW of Bajaj / PCGLLL 36 57 of Polycab / VENUSNEOHE2X2PLR18-42WLED857MOD of Havells
Material and labour for concealed sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Supply and laying XLPE LT Cable of size 16 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and laying XLPE LT Cable of size 16 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and laying XLPE LT Cable of size 35 Sqmm, 3.5 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Easyways Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .