| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAdmitted-Finance | ₹3.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.8 Cr+₹24.1 L (6.70%)Admitted-Finance | ₹3.8 Cr+₹24.1 L (6.70%) | L2 | Admitted-Finance |
| 3 | L3₹3.9 Cr+₹33.1 L (9.18%)Admitted-Finance | ₹3.9 Cr+₹33.1 L (9.18%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Gaikhonlung Panmei L1 | Sophila Muinao L3 | Nongthombam Motilal Singh L2 |
|---|---|---|---|---|---|---|
| 1.00DC Bangalow | ||||||
| 2.00( I )- Construction of Perimeter fencing | ||||||
| 3.00SH: (A)DISMANTLING & DEMOLISHING | ||||||
| 4.00 | Dismantling barbed wire or flexible wire rope in fencing includingmaking rolls and stacking within 50 metres lead. | 1 | Each | 25 ₹25 Lowest | 26 ₹26 | 26 ₹26 |
| 5.00 | Dismantling steel work in single sections including dismemberingand stacking within 50 metres lead in:(i)Channels, angles, tees and flats | 279.86 | Kg | 1.5 ₹419.79 Lowest | 2 ₹559.72 | 2 ₹559.72 |
| 6.00 | Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within50 metres lead as per direction of Engineer - in- charge. | 9.53 | m3 | 2,337 ₹22,271.61 Lowest | 2,551 ₹24,311.03 | 2,493 ₹23,758.29 |
| 7.00 | Demolishing dry brick pitching in floors, drains etc. includingstacking serviceable material and disposal of unserviceablematerial within 50 metres lead | 11.42 | m3 | 867 ₹9,901.14 Lowest | 947 ₹10,814.74 | 925 ₹10,563.5 |
| 8.00SH: (B)FENCING(182 Rm + 53.00 m for old fencing=235.00Rm) | ||||||
| 9.00EARTH WORK | ||||||
| 10.00 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil. | 339.45 | m3 | 308 ₹1,04,550.6 Lowest | 336 ₹1,14,055.2 | 328 ₹1,11,339.6 |
Tender Value
₹3.0 Cr
EMD Value
₹6.1 L
Closing Date
17 Mar 2025, 1:00 pmClosed
EE-II
MPHC Office Complex
Upgradation and additional security works of DC Bungalow and Office, Churachandpur under Part-V of the Scheme for Assistance to State for Capital Investment FY 2024-25
2025_MPHCL_2631_1
05/EE-II/MPHC/2023-24
Open Tender
Civil Works
Works
180 days
As per tender documents
As per tender documents
11 documents required · 11 mandatory
₹25,000
MD MPHC
₹6.1 L
18 Mar 2025
10 Mar 2025
17 Mar 2025
10 Mar 2025
17 Mar 2025
10 Mar 2025
10 Mar 2025 - 16 Mar 2025
Amount
DC Bangalow
( I )- Construction of Perimeter fencing
SH: (A)DISMANTLING & DEMOLISHING
Dismantling barbed wire or flexible wire rope in fencing includingmaking rolls and stacking within 50 metres lead.
Dismantling steel work in single sections including dismemberingand stacking within 50 metres lead in:(i)Channels, angles, tees and flats
Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within50 metres lead as per direction of Engineer - in- charge.
Demolishing dry brick pitching in floors, drains etc. includingstacking serviceable material and disposal of unserviceablematerial within 50 metres lead
SH: (B)FENCING(182 Rm + 53.00 m for old fencing=235.00Rm)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a ) Mild steel
(b)Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
BRICK WORKS
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4 coarse sand)
STONE WORKS
Polygonal rubble masonry/R.R. masonry (uncoursed/brought to courses) squared rubble masonry (uncoursed/brought to courses) with hard stone of approved quality in foundation & plinth in cement mortar 1: 6 (1 cement:6 coarse sand) i/c levelling up with cement concrete 1:6:12 (1 cement:6 coarse sand:12 stone aggregate 20 mm nominal size) at plinth level.
FINISHING
12mm cement plaster 1:4 (1 cement : 4 coarse sand).
15mm cement plaster 1:4 (1 cement : 4 coarse sand).
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
MISCELLANEOUS
75 cm, high fencing with angle iron post 50 X 50 X 6 mm of 1.24 m long placed at every 2.44 m apart embeded in R.C.C. columns and every 1st, 5th and corner posts to be struted providing with 6 (six) horizontal lines and two diagonals of G.I. barbed wire ( 0.164 kg/m.) between two posts filled and fixed with G.I. staples etc. complete.
( II )- Construction of Steel Gate
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
BRICK WORKS
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in Superstructure above plinth level upto V level in all shapes and sizes in: (i) (1 Cem: 4 C/Sand)
STEEL WORKS
Providing and fixing steel gate partly grills and partly M.S. sheet 3.16 mm thick with M.S. angle frame of 65 X 65 X 6 mm including handles, hold fasts, locking arrangment and applying a priming coat of red lead paint ( as per standard design),
FINISHING
12mm cement plaster 1:4 (1 cement : 4 coarse sand).
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
( III )- Repairing of DC Residential building
SH: (A)DISMANTLING & DEMOLISHING
Dismantling cement asbestos or other hard board ceiling orpartition walls including stacking of serviceable materials anddisposal of unserviceable materials within 50 metres lead.
Dismantling doors, windows and clerestory windows (steel orwood) shutter including chowkhats, architrave, holdfasts etc.complete and stacking within50 metres lead (i)Of area 3 sq. metres and below
Dismantling wooden boardings in lining of walls and partitions,excluding supporting members but including stacking within 50metres lead : 15.35.1 Upto 10mm thick
Dismantling tile work in floors and roofs laid in cement mortarincluding stacking material within 50 metre lead.15.23.1 For thickness of tiles above 25 mm and upto 40 mm
SH: (B) REPAIRING BUILDING
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
Repairs to plaster of thickness 12mm to 20mm in patches of area2.5 sq. metres and under including cutting the patch in propershape, raking out joints and preparing and plastering the surface ofthe walls complete including disposal of rubbish to thedumpingground within 50 metres lead : 14.1.1 With cement mortar 1:4 (1 cement: 4 fine sand)
WOOD WORKS
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Tolhao wood
Providingandfixingpanelledorpanelledandglazedshuttersfordoors,windowsandclerestorywindowsincludingISImarkedM.Sbutthingesbrightfinishedofrequiredsizewithnecessaryscrews,excludingpanellingwhichwillbepaidforseparately,allcompleteas per direction of Engineer-in-charge.(a) Local best quality Tolhao wood(b)35 mm thick shutters
Providing and fixing M.S. round or square bars with M.S. flats at required spcing in wooden frames of windows and clerestory windows.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125 mm
Providing and fixing bright finished brass hard drawn hooks and eyes (i) 300mm
Providing and fixing 20mm plank as eave board with :- (a) Tolhao/Uchan wood.
ROOFING AND CEILING
P/F false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bounded pressed particle board conforming to I.S: 3087 finished wiP/F false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bounded pressed particle board conforming to I.S: 3087 finished with a ccoat of aluminium primer on both sides 7 edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-section 35 X 15 X 1.5 mm size main runners placed 600 mm centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S. rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600 X 1200 mm centre to centre i/c fixing to the frame with C.P brace screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately).
FLOORING
Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tilesmust be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips ofrequired thickness, leveling system and rubber mallet for placingthe tiles gently and easily.(1)Double charge vitrified tile polished finish of size (ii)Size of Tile 600 x 600 mm
FINISHING
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including priming coat with cement primer:- sqm Rs.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
2nd class brick masonary 15 x 15cm open surface drain in c.m. 1: 5(1cem: 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem: 5 c/sand : 10gr. st. aggrt. 40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem: 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
SH : ( B ) SANITARY ITEMS
Providing and fixing white vitreous china pedestal type water closet ( European type W.C. pan ) with seat and lid, 10 litre low level white PVC. flushing cistern i/c flush pipe ,manually controlled device (handle lever) conforming to IS 7231 with all fiiting and fixture complete i/c cutting and making good the wall and floor, wherever required: i) W.C pan with ISI marked white solid plastic seat and lid.
Providing and Fixing wash basin with C.I. brackets, 15mm C.P BRASS PILLAR TAPS, 32mm C.P brass waste of standard patter, i/c painting of fittings and brackets,cutting and making good the walls whereever required a) white vitreous china flat back wash basin size 450x300mm with single 15 mm C.P brass pillar tap.
Providing and fixing C.P. bib cock of superior quality.
Providing and fixing brass stop cock of superior quality.
Providing and fixing 610 x 20 mm Diplomat brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws
Providing and fixing 600 X 450 mm bevelled edge Mirror of superior glass (of approved quality) quality complete with 6mm thick hard board ground fixed to wooden cleat with C.P. brass screws and washers complete.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc. (Internal work). a)15 mm diameter
Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc. (External work). a) 32 mm diameter
Providing and fixing 100mm H.C.I. soil, waste & vent pipe
Providing and fixing grating for gully trap or Nahni trap. Satinless steel i) 100 mm nominal diameter.
Providing and fixing Lead chaulked joints to 100 mm H.C.I. pipes
Providing and fixing 100 mm terminal guard.
Providing and fixing 100x100x100mm H.C.I.plain branch of the required degree.
Providing and fixing C.P. brass shower rose with 12.5 mm or 19 mm inlet.(a) 20 mm diameter. ordinary
SH: Providing and installing IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades without regulator etc.as reqd. (Make Bajaj/Usha or Similar)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F call bell/buzzer suitable foe DC/AC single phase 230V complete as reqd.
S/F bell push modular type complete as reqd.
S/F 25 amp air-conditioner power plug point i/c 4 modules metal box on surface or in recess 4-modules plate and cover in front, 25 amp modular starter modular socket outlet and 25 amp plug i/c connection etc. as reqd.
S/F 1.5 ton 5 stars inverter service split air conditioner with stabilizer in built including all accessories for maximum separation of 5mts and connection as reqd. Make Samsung, Model No. AR18TV5PAWK.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
( IV )- Extention of Bedroom
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level. ( a ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
BRICK WORKS
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4 coarse sand)
FINISHING
12mm cement plaster 1:4 (1 cement : 4 coarse sand).
15mm cement plaster 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
WOOD WORKS
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Tolhao wood
Providing wood work in trusses, purlins, rafter, posts, post plate wall plate & the like wrought framed hoisted & fixed in position.(a) First class Uningthou wood.
Providingandfixingpanelledorpanelledandglazedshuttersfordoors,windowsandclerestorywindowsincludingISImarkedM.Sbutthingesbrightfinishedofrequiredsizewithnecessaryscrews,excludingpanellingwhichwillbepaidforseparately,allcompleteas per direction of Engineer-in-charge.(a) Local best quality Tolhao wood(b)35 mm thick shutters
Providing and fixing M.S. round or square bars with M.S. flats at required spcing in wooden frames of windows and clerestory windows.
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125 mm
Providing and fixing bright finished brass hard drawn hooks and eyes (i) 300mm
ROOFING AND CEILING
P/F false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bounded pressed particle board conforming to I.S: 3087 finished wiP/F false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bounded pressed particle board conforming to I.S: 3087 finished with a ccoat of aluminium primer on both sides 7 edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-section 35 X 15 X 1.5 mm size main runners placed 600 mm centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S. rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600 X 1200 mm centre to centre i/c fixing to the frame with C.P brace screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately).
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
FLOORING
Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tilesmust be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips ofrequired thickness, leveling system and rubber mallet for placingthe tiles gently and easily.(1)Double charge vitrified tile polished finish of size (ii)Size of Tile 600 x 600 mm
FINISHING
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Applying priming coat :- (b) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including priming coat with cement primer:- sqm Rs.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
2nd class brick masonary 15 x 15cm open surface drain in c.m. 1: 5(1cem: 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem: 5 c/sand : 10gr. st. aggrt. 40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem: 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
SH : ( B ) SANITARY ITEMS
Providing and fixing white vitreous china pedestal type water closet ( European type W.C. pan ) with seat and lid, 10 litre low level white PVC. flushing cistern i/c flush pipe ,manually controlled device (handle lever) conforming to IS 7231 with all fiiting and fixture complete i/c cutting and making good the wall and floor, wherever required: i) W.C pan with ISI marked white solid plastic seat and lid.
Providing and Fixing wash basin with C.I. brackets, 15mm C.P BRASS PILLAR TAPS, 32mm C.P brass waste of standard patter, i/c painting of fittings and brackets,cutting and making good the walls whereever required a) white vitreous china flat back wash basin size 450x300mm with single 15 mm C.P brass pillar tap.
Providing and fixing C.P. bib cock of superior quality.
Providing and fixing brass stop cock of superior quality.
Providing and fixing 610 x 20 mm Diplomat brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws
Providing and fixing 600 X 450 mm bevelled edge Mirror of superior glass (of approved quality) quality complete with 6mm thick hard board ground fixed to wooden cleat with C.P. brass screws and washers complete.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc. (Internal work). a)15 mm diameter
Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc. (External work). a) 32 mm diameter
Providing and fixing grating for gully trap or Nahni trap. Satinless steel i) 100 mm nominal diameter.
Providing and fixing Lead chaulked joints to 100 mm H.C.I. pipes
SH: Providing and installing IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades without regulator etc.as reqd. (Make Bajaj/Usha or Similar)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
(V) Construction of SM Barrack
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Mild steel and Medium\Tensile steel bars.
( b ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
BRICK WORKS
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4 coarse sand)
STEELWORKS
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
Providing & fixing 3 mm thick M.S. sheet door shutter and gate shutter with chaukat frame of 60 X 60 X 5 mm, door frame 50 X 50 X 5 mm bracing and lodging rod, hold fast etc. of 40 X 40 X 5 mm with locking arrangement, hooks and handles with sliding bolts and including the cost of priming coat.
Extra for providing and fixing wind ties of 40x 6mm flat iron section
FINISHING
12mm cement plaster 1:4 (1 cement : 4 coarse sand).
15mm cement plaster 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
WOOD WORKS
Steel glazed windows and ventilators of standard rolled steel section joints mitred and welded with 15 x 3 mm lugs 10 cm long with steel plugs embedded in cement concrete block 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 stone aggregate 20 mm nominal size) or wooden plugs and screws of rawl plugs and screws or with fixing clips with bolts and nuts as required including providing and fixing of 4 mm thick glass panes with glazing clips complete including applying a priming coat of approved steel primer excluding cost of metal beadings and other fittings except necessary hinges or pivots as required.(i) Ready made steel windows (side hung /top hung)
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125 mm
Providing and fixing 20mm plank as eave board with :- (a) Tolhao/Uchan wood.
ROOFING AND CEILING
P/F false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bounded pressed particle board conforming to I.S: 3087 finished wiP/F false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bounded pressed particle board conforming to I.S: 3087 finished with a ccoat of aluminium primer on both sides 7 edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-section 35 X 15 X 1.5 mm size main runners placed 600 mm centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S. rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600 X 1200 mm centre to centre i/c fixing to the frame with C.P brace screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately).
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
FLOORING
Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tilesmust be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips ofrequired thickness, leveling system and rubber mallet for placingthe tiles gently and easily.(1)Double charge vitrified tile polished finish of size (ii)Size of Tile 600 x 600 mm
FINISHING
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coat :- (b) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including priming coat with cement primer:- sqm Rs.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
2nd class brick masonary 15 x 15cm open surface drain in c.m. 1: 5(1cem: 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem: 5 c/sand : 10gr. st. aggrt. 40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem: 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
SH: Providing and insstalling IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades without regulator etc.as reqd. (Make Bajaj/Usha or Similar)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Wiring for submain with 10m2 weather proof twin core Al. cond. Cableand G.I. bearer wire as reqd.
(VI) Construction of Kitchen cum dining hall
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Mild steel and Medium\Tensile steel bars.
( b ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
BRICK WORKS
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4 coarse sand)
STONE WORKS
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 Kanhaighat coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : (i) Cement mortar 1:6(1 cement: 6 Kanhaighat coarse sand)
STEELWORKS
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
Extra for providing and fixing wind ties of 40x 6mm flat iron section
FINISHING
12mm cement plaster 1:4 (1 cement : 4 coarse sand).
15mm cement plaster 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
WOOD WORKS
Providingandfixingpanelledorpanelledandglazedshuttersfordoors,windowsandclerestorywindowsincludingISImarkedM.Sbutthingesbrightfinishedofrequiredsizewithnecessaryscrews,excludingpanellingwhichwillbepaidforseparately,allcompleteas per direction of Engineer-in-charge.(a) Local best quality Tolhao wood (b)35 mm thick shutters
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Tolhao wood
25mm wooden planking, tongued and grooved in flooring including fixing with iron screws complete with :a) Ist class teak wood
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125 mm
Providing and fixing bright finished brass hard drawn hooks and eyes (i) 300mm
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Providing and fixing 20mm plank as eave board with :- (a) Tolhao/Uchan wood.
ROOFING AND CEILING
P/F false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bounded pressed particle board conforming to I.S: 3087 finished wiP/F false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bounded pressed particle board conforming to I.S: 3087 finished with a ccoat of aluminium primer on both sides 7 edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-section 35 X 15 X 1.5 mm size main runners placed 600 mm centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S. rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600 X 1200 mm centre to centre i/c fixing to the frame with C.P brace screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately).
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
FLOORING
Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tilesmust be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips ofrequired thickness, leveling system and rubber mallet for placingthe tiles gently and easily.(1)Double charge vitrified tile polished finish of size (ii)Size of Tile 600 x 600 mm
FINISHING
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coat :- (b) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including priming coat with cement primer:- sqm Rs.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
2nd class brick masonary 15 x 15cm open surface drain in c.m. 1: 5(1cem: 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem: 5 c/sand : 10gr. st. aggrt. 40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem: 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
SH: Providing and installing IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades without regulator etc.as reqd. (Make Bajaj/Usha or Similar)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Wiring for submain with 10m2 weather proof twin core Al. cond. Cableand G.I. bearer wire as reqd.
( VII) Construction of Toilet block
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
(b) 1:3:6 (1 cem :3 coarse sand:6 graded stone aggrt.40mm n/size).
(c) 1:2:4 (1 cem :2 coarse sand:4 graded stone aggrt.20mm n/size).
RCC WORKS
Providing and laying in position ready mixed plain cement concrete or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland/ Portland Slag cement, admixture in recommended proportions as per IS:9103 to accelerate / retard setting of concrete,to improve ductility and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge; for the follwing grades of concrete.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Mild steel and Medium\Tensile steel bars.
( b ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
BRICK WORKS
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4 coarse sand)
STONE WORKS
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 Kanhaighat coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : (i) Cement mortar 1:6(1 cement: 6 Kanhaighat coarse sand)
STEELWORKS
Extra for providing and fixing wind ties of 40x 6mm flat iron section
FINISHINGS
12mm cement plaster 1:4 (1 cement : 4 coarse sand).
15mm cement plaster 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
WOOD WORKS
Providingandfixingpanelledorpanelledandglazedshuttersfordoors,windowsandclerestorywindowsincludingISImarkedM.Sbutthingesbrightfinishedofrequiredsizewithnecessaryscrews,excludingpanellingwhichwillbepaidforseparately,allcompleteas per direction of Engineer-in-charge.(a) Local best quality Tolhao wood (b)35 mm thick shutters
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Tolhao wood
Providing wood work in trusses, purlins, rafter, posts, post plate wall plate & the like wrought framed hoisted & fixed in position. (c) Uchan/Tairen/Tolhao/Khangra.
25mm wooden planking, tongued and grooved in flooring including fixing with iron screws complete with :a) Ist class teak wood
Providing and fixing M.S. round or square bars with M.S. flats at required spcing in wooden frames of windows and clerestory windows.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125 mm
Providing and fixing bright finished brass hard drawn hooks and eyes (i) 300mm
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Providing and fixing 20mm plank as eave board with :- (a) Tolhao/Uchan wood.
ROOFING AND CEILING
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
FLOORING
Providing and fixing 10mm thick acid and/or alkali resistant tilesof approved make and colour using acid and/or alkali resistingmortar bedding and joints filled with acid and/or alkali resistingcement as per IS : 4457 complete as per the direction of Engineer-in- Charge(a)In flooring on a bed of 10 mm thick mortar 1:4(1 acid proof cement: 4 coarse sand)(.i)Acid and alkali resistant tile.
Providing and fixing 10mm thick acid and/or alkali resistant tilesof approved make and colour using acid and/or alkali resistingmortar bedding and joints filled with acid and/or alkali resistingcement as per IS : 4457 complete as per the direction of Engineer-in- Charge(a)In flooring on a bed of 10 mm thick mortar 1:4(1 acid proof cement: 4 coarse sand) (.i)In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand).
FINISHING
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Applying priming coat :- (b) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including priming coat with cement primer:- sqm Rs.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
2nd class brick masonary 15 x 15cm open surface drain in c.m. 1: 5(1cem: 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem: 5 c/sand : 10gr. st. aggrt. 40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem: 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
SH : ( B ) SANITARY ITEMS
Providing and fixing white vitreous china pedestal type water closet ( European type W.C. pan ) with seat and lid, 10 litre low level white PVC. flushing cistern i/c flush pipe ,manually controlled device (handle lever) conforming to IS 7231 with all fiiting and fixture complete i/c cutting and making good the wall and floor, wherever required: i) W.C pan with ISI marked white solid plastic seat and lid.
Providing and Fixing wash basin with C.I. brackets, 15mm C.P BRASS PILLAR TAPS, 32mm C.P brass waste of standard patter, i/c painting of fittings and brackets,cutting and making good the walls whereever required a) white vitreous china flat back wash basin size 450x300mm with single 15 mm C.P brass pillar tap.
Providing and fixing C.P. bib cock of superior quality.
Providing and fixing brass stop cock of superior quality.
Providing and fixing 610 x 20 mm Diplomat brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws
Providing and fixing 600 X 450 mm bevelled edge Mirror of superior glass (of approved quality) quality complete with 6mm thick hard board ground fixed to wooden cleat with C.P. brass screws and washers complete.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc. (Internal work). a)15 mm diameter
Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the walls etc. (External work). a) 32 mm diameter
Providing and fixing 100mm H.C.I. soil, waste & vent pipe
Providing and fixing grating for gully trap or Nahni trap. Satinless steel i) 100 mm nominal diameter.
Providing and fixing Lead chaulked joints to 100 mm H.C.I. pipes
Providing and fixing 100 mm terminal guard.
Providing and fixing 100x100x100mm H.C.I.plain branch of the required degree.
Providing and fixing C.P. brass shower rose with 12.5 mm or 19 mm inlet.(a) 20 mm diameter. ordinary
P/F C.I cover with frame for (manhole and chamber) (a) 600x450mm (Heavy duty)
SH: Providing and installing IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories(usha/ Bajaj/ Orient)
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Wiring for submain with 10m2 weather proof twin core Al. cond. Cableand G.I. bearer wire as reqd.
(VIII) Construction of 15000 litre Water Reservoir
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level
(b) 1:3:6 (1 cem :3 coarse sand:6 graded stone aggrt.40mm n/size).
(c) 1:2:4 (1 cem :2 coarse sand:4 graded stone aggrt.20mm n/size).
RCC WORKS
Providing and laying in position ready mixed plain cement concrete or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland/ Portland Slag cement, admixture in recommended proportions as per IS:9103 to accelerate / retard setting of concrete,to improve ductility and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge; for the follwing grades of concrete.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
(c) Edges of slab and breaks in floors and walls (i) Under 20cm wide
FINISHING
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
FLOORING
Providing and fixing 10mm thick acid and/or alkali resistant tilesof approved make and colour using acid and/or alkali resistingmortar bedding and joints filled with acid and/or alkali resistingcement as per IS : 4457 complete as per the direction of Engineer-in- Charge(a)In flooring on a bed of 10 mm thick mortar 1:4(1 acid proof cement: 4 coarse sand)(.i)Acid and alkali resistant tile.
Providing and fixing 10mm thick acid and/or alkali resistant tilesof approved make and colour using acid and/or alkali resistingmortar bedding and joints filled with acid and/or alkali resistingcement as per IS : 4457 complete as per the direction of Engineer-in- Charge(a)In flooring on a bed of 10 mm thick mortar 1:4(1 acid proof cement: 4 coarse sand) (.i)In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand).
SH : ( B ) ELEVATED PLATEFORM
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
RCC WORKS
Providing and laying in position ready mixed plain cement concrete or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland/ Portland Slag cement, admixture in recommended proportions as per IS:9103 to accelerate / retard setting of concrete,to improve ductility and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of Engineer-in-charge; for the follwing grades of concrete.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Mild steel and Medium\Tensile steel bars.
( b ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
STEELWORKS
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level.(i)1000 litres net capacity storage tanks
(IX) SH: Construction of Sentry Tower (2 nos)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Mild steel and Medium\Tensile steel bars.
( b ) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, Pillars, Piers, Abutments, Posts and Struts.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
(d) Suspended floors, roofs, landings, balconies and access platform,with water proof ply 12mm thick.
(e) Edges of slab and breaks in floors and walls (i) Under 20cm wide
BRICK WORKS
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
STONE WORKS
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 Kanhaighat coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : (i) Cement mortar 1:6(1 cement: 6 Kanhaighat coarse sand)
STEELWORKS
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
Extra for providing and fixing wind ties of 40x 6mm flat iron section
FINISHING
12mm cement plaster 1:4 (1 cement : 4 coarse sand).
15mm cement plaster 1:4 (1 cement : 4 coarse sand).
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
WOOD WORKS
Providing wood work in trusses, purlins, rafter, posts, post plate wall plate & the like wrought framed hoisted & fixed in position. (c) Uchan/Tairen/Tolhao/Khangra.
Providing and fixing steel gate partly grills and partly M.S. sheet 3.16 mm thick with M.S. angle frame of 65 X 65 X 6 mm including handles, hold fasts, locking arrangment and applying a priming coat of red lead paint ( as per standard design),
Supplying 40 mm X 3 mm X 275 mm F.B. twisted plate i/c cost of bolts & nuts.
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Providing and fixing 20mm plank as eave board with :- (a) Tolhao/Uchan wood.
ROOFING AND CEILING
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
FLOORING
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4graded stone aggregate) finished with a floating coat of neatcement including cement slurry, but excluding the cost of nosingof steps etc. complete.40mm thick with 20mm nominal size stone aggregate
FINISHING
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coat :- (b) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
SH: Providing and installing IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
3 pin 5/6 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F50 W LED 5000K energy saving IP 65 Flood Light luminaries with high power COB LED as light source Havell's LHEPBFUEIN6W050
Wiring for submain with 10m2 weather proof twin core Al. cond. Cableand G.I. bearer wire as reqd.
(X) Construction of Light vehicle Garrage
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for: (a) Foundation footings, bases of columns etc. and mass concrete.
(c) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
STONE WORKS
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 Kanhaighat coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : (i) Cement mortar 1:6(1 cement: 6 Kanhaighat coarse sand)
STEELWORKS
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc.complete. (a) Electric resistance or induction butt welded tubes
FINISHING
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
ROOFING AND CEILING WORK
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
FLOORING
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4graded stone aggregate) finished with a floating coat of neatcement including cement slurry, but excluding the cost of nosingof steps etc. complete.40mm thick with 20mm nominal size stone aggregate
FINISHING
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
25mm wooden planking, tongued and grooved in flooring including fixing with iron screws complete with :a) Ist class teak wood
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
2nd class brick masonary 15 x 15cm open surface drain in c.m. 1: 5(1cem: 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem: 5 c/sand : 10gr. st. aggrt. 40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem: 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
Providing and fixing 20mm plank as eave board with :- (a) Tolhao/Uchan wood.
Providing and fixing M.S. round holding down with nuts and wahser plates completes
SH: Providing and installing IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F50 W LED 5000K energy saving IP 65 Flood Light luminaries with high power COB LED as light source Havell's LHEPBFUEIN6W050
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Wiring for submain with 10m2 weather proof twin core Al. cond. Cableand G.I. bearer wire as reqd.
(XI) Construction of Hall
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars
Centering and shuttering including strutting, propping etc. and removal of form for:(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Lintels, beams, plinth beams, girders, bressumers and cantilevers,with water proof ply 12mm thick.
(c) Columns, Pillars, Piers, Abutments, Posts and Struts.
STONE WORKS
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 Kanhaighat coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with : (i) Cement mortar 1:6(1 cement: 6 Kanhaighat coarse sand)
BRICK WORKS
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in : (i) cement mortar 1:4 (1 cement : 4 coarse sand)
WOOD WORKS
Providing wood work in trusses, purlins, rafter, posts, post plate wall plate & the like wrought framed hoisted & fixed in position. (c) Uchan/Tairen/Tolhao/Khangra.
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Tolhao wood
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws..(a) Local best quality Tolhao wood .(35mm thick).
Providing and fixing M.S. round or square bars with M.S. flats at required spcing in wooden frames of windows and clerestory windows.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 Kanhaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125 mm
Providing and fixing 20mm plank as eave board with :- (a) Tolhao/Uchan wood.
FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
FLOORING
Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tilesmust be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips ofrequired thickness, leveling system and rubber mallet for placingthe tiles gently and easily.(1)Double charge vitrified tile polished finish of size (ii)Size of Tile 600 x 600 mm
ROOFING AND CEILING WORK
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
P/F false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bounded pressed particle board conforming to I.S: 3087 finished wiP/F false ceiling with 12 mm thick plain / semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bounded pressed particle board conforming to I.S: 3087 finished with a ccoat of aluminium primer on both sides 7 edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-section 35 X 15 X 1.5 mm size main runners placed 600 mm centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S. rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600 X 1200 mm centre to centre i/c fixing to the frame with C.P brace screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately).
FINISHING
Applying priming coat :- (b) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
White washing with lime to give an even shade: —(a)New work (three or more coats)
Colour washing such as green, blue or buff to give an even shade :(a)Newwork(twoormorecoats)withabasecoatofwhitewashingwith lime
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
2nd class brick masonary 15 x 15cm open surface drain in c.m. 1: 5(1cem: 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem: 5 c/sand : 10gr. st. aggrt. 40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem: 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
SH: Providing and installing IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades without regulator etc.as reqd. (Make Bajaj/Usha or Similar)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
Wiring for submain with 10m2 weather proof twin core Al. cond. Cableand G.I. bearer wire as reqd.
DC OFFICE CHURACHANDPUR
(XII) GROUND FLO
SH: (A)DISMANTLING & DEMOLISHING
Dismantling doors, windows and clerestory windows (steel orwood) shutter including chowkhats, architrave, holdfasts etc.complete and stacking within50 metres lead (i)Of area 3 sq. metres and below
Dismantling tile work in floors and roofs laid in cement mortarincluding stacking material within 50 metre lead.15.23.1 For thickness of tiles above 25 mm and upto 40 mm
Dismantling cement asbestos or other hard board ceiling orpartition walls including stacking of serviceable materials anddisposal of unserviceable materials within 50 metres lead.
Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within50 metres lead as per direction of Engineer - in- charge.
Repairs to plaster of thickness 12mm to 20mm in patches of area2.5 sq. metres and under including cutting the patch in propershape, raking out joints and preparing and plastering the surface ofthe walls complete including disposal of rubbish to thedumpingground within 50 metres lead : (a) With cement mortar 1:4 (1 cement: 4 fine sand)
SH: (B) REPAIRING BUILDING
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
WOOD WORKS
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Teak wood
Providingandfixingpanelledorpanelledandglazedshuttersfordoors,windowsandclerestorywindowsincludingISImarkedM.Sbutthingesbrightfinishedofrequiredsizewithnecessaryscrews,excludingpanellingwhichwillbepaidforseparately,allcompleteas per direction of Engineer-in-charge.(a) Local best quality Teak wood
Providing and fixing M.S. round or square bars with M.S. flats at required spcing in wooden frames of windows and clerestory windows.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125 mm
Providing and fixing bright finished brass hard drawn hooks and eyes (i) 300mm
ROOFING AND CEILING
Providing and fixing at all height false ceiling including providingand fixing of frame work made of special sections, power pressedfrom M.S. sheet and galvanised with zinc coating of 120 gms/ sqm(both sided inclusive) as per IS : 277 and consisting of angle cleatsof size 25mm wide x 1.6mm thick with flanges of 27mm and37mm, at 1200mm centre to centre, one flange fixed to the ceilingwith dash fastener 12.5mm diax50mm long with 6mm diabolts,other flange of cleat fixed to the angle hangers of25x25x0.55mm of required length with nuts and bolts of requiredsize and the other end of the angle hanger fixed with intermediateG.I. channels 45x15x0.9mm running at the spacing of 1200mmcentre to centre, to which the ceiling section 0.5mm thick bottomwedge of 80mm with tapered flanges of 26mm each having clips of10.5mm at 450mm centre to centre, shall be fixed in a directionperpendicular to G.I. intermediate channel with connecting clipsmade out of 2.64mm diax230mm long G.I. wire at every junction,including fixing perimeter channels 0.5mm thick 27mm high havingflanges of 20mm and 30mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws @ 230mm interval, including fixing ofgypsum board to ceiling section and perimeter channel with thehelp of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing andfinishng to a flush finish of tapered and square edges of the boardwith recommended jointing compound,jointing tapes, finishingwith jointing compund in 3 layers covering upto 150 mm on bothsides of joint and two coats of primer suitable for board,all as permanufacturer's specification and also including the cost of makingopenings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as perdrawings, and specification and direction of the Engineer in Chargebut excluding the cost of painting with :(i) Fully Perforated Gypsum Plaster Board of size 1200 x 2400 x 12.5mm having approx. 15% perforated size and pattern as approvedby the Engineer-in-charge and as per manufacter's specification,with all 4 sides tapered and backed by acoustical tissue with NRCvalue not less than 0.60.
FLOORING
Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tilesmust be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips ofrequired thickness, leveling system and rubber mallet for placingthe tiles gently and easily. (a)Double charge vitrified tile polished finish of size(i)Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacture) , with water absorption less than 0.08 % and conforming to I.S.15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (! Cement :3 3 coarse sand), joining with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. (i) Size of Tile 600X600mm
FINISHING
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including priming coat with cement primer:- sqm Rs.
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
SH: Providing and installing IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
(c) 2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
70mm2 3.5 core PVC ins.(heavy duty) Al.cond.armoured cable of 1.1KV grade of size not exceeding 25mm2 but not exceeding 125mm2 direct in ground i/c excavation sand, cushioning protective covering & refilling etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
1. 200 amp. TPN on load changeover switch - 1 No.
2. 200 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 4 Nos.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades without regulator etc.as reqd. (Make Bajaj/Usha or Similar)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F call bell/buzzer suitable foe DC/AC single phase 230V complete as reqd.
S/F bell push modular type complete as reqd.
S/F 25 amp air-conditioner power plug point i/c 4 modules metal box on surface or in recess 4-modules plate and cover in front, 25 amp modular starter modular socket outlet and 25 amp plug i/c connection etc. as reqd.
S/F 1.5 ton 5 stars inverter service split air conditioner with stabilizer in built including all accessories for maximum separation of 5mts and connection as reqd. Make Samsung, Model No. AR18TV5PAWK.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F surface/ pendent mounting 1 x 18 W LED lamp channel luminories complete with all accersories connection etc. as required
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
(XIII) FIRST FLOOR
SH: (A)DISMANTLING & DEMOLISHINGR
Dismantling doors, windows and clerestory windows (steel orwood) shutter including chowkhats, architrave, holdfasts etc.complete and stacking within50 metres lead (i)Of area 3 sq. metres and below
Dismantling tile work in floors and roofs laid in cement mortarincluding stacking material within 50 metre lead.15.23.1 For thickness of tiles above 25 mm and upto 40 mm
Dismantling cement asbestos or other hard board ceiling orpartition walls including stacking of serviceable materials anddisposal of unserviceable materials within 50 metres lead.
Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within50 metres lead as per direction of Engineer - in- charge.
Repairs to plaster of thickness 12mm to 20mm in patches of area2.5 sq. metres and under including cutting the patch in propershape, raking out joints and preparing and plastering the surface ofthe walls complete including disposal of rubbish to thedumpingground within 50 metres lead : (a) With cement mortar 1:4 (1 cement: 4 fine sand)
SH: (B) REPAIRING BUILDING
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:5:10 (1 cement :5 coarse sand :10 graded stone aggrt. 40mm nominal size).
WOOD WORKSG
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local best quality Teak wood
Providingandfixingpanelledorpanelledandglazedshuttersfordoors,windowsandclerestorywindowsincludingISImarkedM.Sbutthingesbrightfinishedofrequiredsizewithnecessaryscrews,excludingpanellingwhichwillbepaidforseparately,allcompleteas per direction of Engineer-in-charge.(a) Local best quality Teak wood
Providing and fixing M.S. round or square bars with M.S. flats at required spcing in wooden frames of windows and clerestory windows.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125 mm
Providing and fixing bright finished brass hard drawn hooks and eyes (i) 300mm
ROOFING AND CEILING
Providing and fixing at all height false ceiling including providingand fixing of frame work made of special sections, power pressedfrom M.S. sheet and galvanised with zinc coating of 120 gms/ sqm(both sided inclusive) as per IS : 277 and consisting of angle cleatsof size 25mm wide x 1.6mm thick with flanges of 27mm and37mm, at 1200mm centre to centre, one flange fixed to the ceilingwith dash fastener 12.5mm diax50mm long with 6mm diabolts,other flange of cleat fixed to the angle hangers of25x25x0.55mm of required length with nuts and bolts of requiredsize and the other end of the angle hanger fixed with intermediateG.I. channels 45x15x0.9mm running at the spacing of 1200mmcentre to centre, to which the ceiling section 0.5mm thick bottomwedge of 80mm with tapered flanges of 26mm each having clips of10.5mm at 450mm centre to centre, shall be fixed in a directionperpendicular to G.I. intermediate channel with connecting clipsmade out of 2.64mm diax230mm long G.I. wire at every junction,including fixing perimeter channels 0.5mm thick 27mm high havingflanges of 20mm and 30mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450mm centre, with25mm long drive-all screws @ 230mm interval, including fixing ofgypsum board to ceiling section and perimeter channel with thehelp of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing andfinishng to a flush finish of tapered and square edges of the boardwith recommended jointing compound,jointing tapes, finishingwith jointing compund in 3 layers covering upto 150 mm on bothsides of joint and two coats of primer suitable for board,all as permanufacturer's specification and also including the cost of makingopenings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all complete as perdrawings, and specification and direction of the Engineer in Chargebut excluding the cost of painting with :(i) Fully Perforated Gypsum Plaster Board of size 1200 x 2400 x 12.5mm having approx. 15% perforated size and pattern as approvedby the Engineer-in-charge and as per manufacter's specification,with all 4 sides tapered and backed by acoustical tissue with NRCvalue not less than 0.60.
FLOORING
Providing and laying Vitrified tiles in floor in different sizes(thickness to be specified by the manufacturer) with waterabsorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tilesmust be cut with the zero chipping diamond cutter only . Laying oftiles will be done with the notch trowel, plier, wedge, clips ofrequired thickness, leveling system and rubber mallet for placingthe tiles gently and easily. (a)Double charge vitrified tile polished finish of size(i)Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacture) , with water absorption less than 0.08 % and conforming to I.S.15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (! Cement :3 3 coarse sand), joining with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. (i) Size of Tile 600X600mm
FINISHING
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including priming coat with cement primer:- sqm Rs.
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
SH: Providing andd installing IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
(c) 2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades without regulator etc.as reqd. (Make Bajaj/Usha or Similar)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F call bell/buzzer suitable foe DC/AC single phase 230V complete as reqd.
S/F bell push modular type complete as reqd.
S/F 25 amp air-conditioner power plug point i/c 4 modules metal box on surface or in recess 4-modules plate and cover in front, 25 amp modular starter modular socket outlet and 25 amp plug i/c connection etc. as reqd.
S/F 1.5 ton 5 stars inverter service split air conditioner with stabilizer in built including all accessories for maximum separation of 5mts and connection as reqd. Make Samsung, Model No. AR18TV5PAWK.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F surface/ pendent mounting 1 x 18 W LED lamp channel luminories complete with all accersories connection etc. as required
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
(XIV)SECOND FLOOR
WOOD WORKS
Providingandfixingpanelledorpanelledandglazedshuttersfordoors,windowsandclerestorywindowsincludingISImarkedM.Sbutthingesbrightfinishedofrequiredsizewithnecessaryscrews,excludingpanellingwhichwillbepaidforseparately,allcompleteas per direction of Engineer-in-charge.(a) Local best quality Teak wood
Providing and fixing M.S. round or square bars with M.S. flats at required spcing in wooden frames of windows and clerestory windows.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :(a) 300x16 mm
Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : (a) 250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete :(a) 125 mm
Providing and fixing bright finished brass hard drawn hooks and eyes (i) 300mm
FINISHING
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including priming coat with cement primer:- sqm Rs.
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
SH: Providing and installing IEI
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in pvc casing & capping with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in PVC casing & capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC casing & capping etc.as reqd.
(a) 2X2.5mm2+1X2.5mm2 earth wire
(b) 2X4mm2+1X4mm2 earth wire
(c) 2X10mm2+1X10mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades without regulator etc.as reqd. (Make Bajaj/Usha or Similar)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
S/F call bell/buzzer suitable foe DC/AC single phase 230V complete as reqd.
S/F bell push modular type complete as reqd.
S/F 25 amp air-conditioner power plug point i/c 4 modules metal box on surface or in recess 4-modules plate and cover in front, 25 amp modular starter modular socket outlet and 25 amp plug i/c connection etc. as reqd.
S/F 1.5 ton 5 stars inverter service split air conditioner with stabilizer in built including all accessories for maximum separation of 5mts and connection as reqd. Make Samsung, Model No. AR18TV5PAWK.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb
S/F surface/ pendent mounting 1 x 18 W LED lamp channel luminories complete with all accersories connection etc. as required
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
(XV) Installation concertina/Razor wire on DC office
Demolishing Cement Concete manually/ by mechanical means and disposal of material withn 50 m lead as per direction of Engineer in charge
providing and laying in position cement concrete of specified grade excluding the cost of centering , shuttering all works upto plinth level - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nsize
75 mm high fencing with angle iron post 50X50X6 mm of 1.24 m long placed at every 2.44 m apart embedded inRCC columns and every 1st, 5th and corner posts to be strutted providing with 6 horizontal line and two diagonals of GI barbed wire (0.164 kg/m) between two posts filled and fixed with GI staples etc complete.
Providing and laying a Concertina/ Razor wire embedded along post fitted and stapples over the existing fence.
Nongthombam Motilal Singh (BID ID -8556)
Sophila Muinao (BID ID -8554)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
Documents.pdf
Tender Documents • 17.61 MB
Drawing.pdf
Additional Documents • 4.15 MB
BOQ_2890.xls
BOQ • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .