Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-Finance | ₹1.4 Cr | L1 | Accepted-Finance Accepted being L1 |
| 2 | L2₹1.4 CrRejected-Finance 121004 | ₹1.4 Cr | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹1.4 CrRejected-Finance WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹1.4 Cr | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹1.5 CrRejected-Finance NO 83 THAMMAIAH GARDEN ABBLIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.5 Cr | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹1.6 CrRejected-Finance NO 68 ANJENEYA TEMPLE CROSS OPP MS RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.6 Cr | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| Sl No | Description | Qty | Unit | RAMESH BABU CO L1 | devan enterprises L5 | M/S Shiv Shakti Enterprises L3 | M/S SRI BALAJI ENTERPRISES L4 | Neptune Engineers and Builders L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for shifting of Air Conditioner, Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed.
Note :- The rate for following works deemed to be included in quoted rate :-
(a) Transportation of air conditioner any type any capacity from one to other location.
(b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed
(c) Fixing only outdoor and indoor units as required and directed
(d) Connecting indoor / outdoors units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inclucating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls
(e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps.
(f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall.
(g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs.
(h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas.
(j) Fixing of copper tubing of qty of required size. | 15 | Each Job | 2,130 ₹31,950 | 2,000 ₹30,000 | 2,500 ₹37,500 | 1,850 ₹27,750 | 2,500 ₹37,500 |
| 2.00 | Removing the window/ split type AC of 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning complete all as specified and directed.
Note :- The rate of following deemed to be included in quoted rate :-
a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower
b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower
c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary
d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, tools and plants, and back in on final position complete
(e) The work shall be done by a specialized team of Engineer/Technicians of OEM.
(f) Spares will be measured and paid separately.
(g) Refrigerant gas will be measured & paid separately. | 105 | Each Job | 1,300 ₹1.4 L | 1,360 ₹1.4 L | 1,300 ₹1.4 L | 1,000 ₹1.1 L | 1,325 ₹1.4 L |
| 3.00 | Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one complete all as specified and directed. | 30 | Each | 500 ₹15,000 | 530 ₹15,900 | 550 ₹16,500 | 465 ₹13,950 | 465 ₹13,950 |
| 4.00 | Supply and fix polyurethene foam insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C of any type and at any location including taking down existing one complete all as specified and directed. | 65 | RM | 75 ₹4,875 | 100 ₹6,500 | 65 ₹4,225 | 45 ₹2,925 | 60 ₹3,900 |
| 5.00 | Supply and fix discharge valve suitable for 1.5 Ton/2 Ton split type AC including taking down existing one complete all as specified and directed. | 20 | Each | 320 ₹6,400 | 390 ₹7,800 | 355 ₹7,100 | 420 ₹8,400 | 350 ₹7,000 |
| 6.00 | Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one complete all as specified and directed. | 18 | Each | 365 ₹6,570 | 490 ₹8,820 | 455 ₹8,190 | 425 ₹7,650 | 445 ₹8,010 |
| 7.00 | Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity, including taking down existing one all as specified and directed. | 10 | Each | 712 ₹7,120 | 690 ₹6,900 | 620 ₹6,200 | 520 ₹5,200 | 700 ₹7,000 |
| 8.00 | Supply and fixing Condenser Fan motor (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity, including taking down existing one and complete all as specified and directed. | 15 | Each | 4,430 ₹66,450 | 4,100 ₹61,500 | 4,100 ₹61,500 | 4,200 ₹63,000 | 4,500 ₹67,500 |
| 9.00 | Supply and fixing as in repair of flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete all as specified and directed. | 80 | RM | 63 ₹5,040 | 85 ₹6,800 | 65 ₹5,200 | 70 ₹5,600 | 65 ₹5,200 |
| 10.00 | Supply and fixing Hermetic sealed/Rotory new compressor for 1.5 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed. | 10 | Each Job | 14,635 ₹1.5 L | 13,900 ₹1.4 L | 400 ₹4,000 | 13,100 ₹1.3 L | 5,250 ₹52,500 |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
26 May 2026, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT TO VARIOUS TYPE OF ACs SUMMER APPLIANCES AREA LIGHTING INFRASTRUCTURE EARTHING LIGHTENING PROTECTION SYSTEM UPKEEP MAINT TO ELECTRICAL SUPPLY INSTALLATION SUB STATION AND OTHER MISC EM WORKS AT AFTC 2 DC AREA AND AFS JALAHALLI
2026_MES_762617_1
8333/E8
Open Tender
Civil Works
180 days
Garrison Engineer M AF Jaalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Garrison Engineer M AF Jalahalli
₹2.2 L
Yes
9 Jun 2026
28 Apr 2026
2 Jun 2026
28 Apr 2026
26 May 2026
19 May 2026
28 Apr 2026 - 5 May 2026
Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fix polyurethene foam insulation indoor to outdoor unit suitable for 1.5 Ton to 2 Ton split type A/C of any type and at any location including taking down existing one complete all as specified and directed.
Supply and fix discharge valve suitable for 1.5 Ton/2 Ton split type AC including taking down existing one complete all as specified and directed.
Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one complete all as specified and directed.
Supply and fixing Front grill (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity, including taking down existing one all as specified and directed.
Supply and fixing Condenser Fan motor (in replacement) suitable for window type Air Conditioner of any make up to and including 1.5/2.0 TR capacity, including taking down existing one and complete all as specified and directed.
Supply and fixing as in repair of flexible PVC pipe of suitable size for indoor unit drain water of split AC suitable for any type and any capacity complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for 1.5 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 1.5 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 3/8" suitable for 1.5 Ton/2 Ton split type AC complete all as specified and directed.
Supply and fix in repair dummy nut of dia 1/4" suitable for 1.5 Ton/2 Ton split type AC complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 5/8" suitable for 1.5 Ton/2 Ton split type AC complete all as specified and directed.
Supply and fix as in repair dummy nut of dia 1/2" suitable for 1.5 Ton/2 Ton split type AC complete all as specified and directed.
Supply and fix Suction valve suitable for 1.5 Ton/2 Ton split type AC of existing make complete all as specified and directed.
Supply and fix Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC 1.5 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one all as specified and directed.
Supply and fix MS wall bracket suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces to match with the existing complete all as specified and directed.
Supply and fixing Blower of indoor unit suitable for 1.5 Ton / 2 Ton split AC including taking down existing unserviceable one at any location complete all as specified and directed.
Supply and fixing Remote assembly corded/cordless (in replacement) for any type and size of split type ACs, upto 2.0 TR including taking down existing one complete all as specified and directed.
Supply and fix PCB board of any make for indoor unit of split AC 1.5 Ton/ 2 Ton including taking down existing one complete all as specified and directed.
Supply and fix indoor unit including blower fan , PCB board and all accessories capacity 1.5/2.0 Ton split type A/C including taking down existing unserviceable one any type complete all as specified and directed.
Supply and fix single phase single pole contactor suitable for 1.5/ 2.0 split type AC complete all as specified and as directed.
Supply and fixing as in repair of Copper tubing of size 1/2" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 1/4" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 5/8" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing as in repair of Copper tubing of size 3/8" flare size conforming to relevant IS complete all as specified and directed.
Supply and fixing Blower motor (in replacement) suitable for split type Air Conditioner of any make up to 2 TR capacity including taking down existing unserviceable one, complete all as specified and directed.
Removing old unserviceable split type air conditioner outdoor unit frame and Supply and fix outdoor unit frame of the split type air conditioner 1.5/2 TR capacity, complete with refixing with all accessories such as hermetically sealed compressor and condenser unit, capacitors, relays, fan motor, duly prewired and including connecting of existing refrigerant gas piping, electrical connections and testing etc complete all as specified and directed.
Supply and fix as in repair PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and directed.
Supply and fixing Remote sensing unit (in replacement) for upto 2.0 TR split type AC including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing Condenser coil (in replacement) after disconnecting the refrigerant connection of defective condenser coil unit of split type AC upto 2.0 TR and replacing the condenser coil unit connecting the same unit with refrigerant connections complete including taking down existing one complete all as specified and directed.
Supply and fixing Hermetic sealed/Rotory new compressor for 2 TR split type AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of split type AC of capacity 2 Ton and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed.
Supply and fix overload protector for split AC 1.5/2 Ton TR capacity including taking down existing unserviceable one complete all as specified and directed.
Supply and fix flair nut of dia 5/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/2" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 3/8" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/4" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix flair nut of dia 1/16" suitable for 1.5 Ton/2 Ton of split type AC complete all as specified and as directed.
Supply and fix 3 pin metal clad plug top 20 Amps, AC 230 volts for any type of AC including taking down existing unserviceable one complete all as specified and as directed.
Supply & fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and as directed. Make : Havells/ Indo asian/ Legrand
M&L core cutting of size 50 mm dia in stone wall with the help of machine and preparing surface to make good matching with existing coloured surface complete all as specified and directed.
M&L core cutting of of size 50 mm dia in bricks wall with the help of machine and preparing surface to make good matching with existing coloured surface complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakages found in the system of window/ split type ACs up to 2 Ton capacity including vacumizing, charging and checking the gas pressure to desire level complete for satisfactory functioning complete all as specified and directed. Note: Toping up of gas shall be measured and paid separately
Supply and filling Regrigerant gas R-410A in manufacturer's sealed cylinder complete all as specified and as directed. (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas filled.
Repair and maintenance of inverter type split AC of any capacity / any Make from any location including attending breakdown calls, routine maintenance and servicing ,testing and commissioning all as specified and directed here under :- a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower. b) Checking electrical connection, cleaning, Greasing, oiling, fan motor, cleaning of air filter with blower. (c) Testing all copper tube ,joints, leads for any leaking and Top up with the refrigerant gas if necessary. (d) The work shall be done by a specialized team of Engineer/Technicians of OEM.
Supply and fix DC blower fan motor for inverter split AC of 1.5 Ton to 2 Ton capacity and including taking down existing unserviceable one of any capacity and at any location complete all as specified and directed.
Supply and fixing PCB board for oudoor unit of inverter type split type AC for 1.5 Ton/2 Ton capacity including taking down existing unserviceable one at any location complete all as specified and directed.
Supply and fixing PCB board for indoor unit of inverter type split type AC for 1.5 Ton/2 Ton capacity including taking down existing unserviceable one at any location complete all as specified and directed.
Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/175/180/185/190/260/277/286/290/308/310/315/350/360/375 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Supply and fixing Chiller tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity, complete all as specified and directed.
Supply and fixing Vegetable tray (in replacement) suitable for Refrigerator of any make, 260 to 308 litres capacity, complete all as specified and as directed.
Material and labour for Freezer compartment including door and accessories suitable for refrigerator 260, 286,308, 315 and 350 ltrs capacity refrigerator and including taking existing unserviceable one complete all as specified and as directed.
Supply and fixing PVC shelf transparent type of tough plastic suitable for refrigerator of capacity 260 to 308 ltrs complete including taking down existing unserviceable one complete all as specified and directed.
Supply and fixing superior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 308 ltrs complete all as specified and directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 260 to 308 Ltr complete all as specified and directed.
Supply and fixing Evaporator coil, suitable for refrigerator of 260 to 308 ltrs any make size and type (in replacement) complete all as specified and as directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 260 to 308 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 260 to 308 litres complete all as specified and directed.
Supply and fix in repair electric bulb 20 watt 230v threaded type for refrigerator of Capacity 260 ltrs to 308 ltrs complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 308 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. for satisfactory functioning complete all as specified and as directed. Note:Topping up of gas shall be measured and paid separately
Supply and fixing Evaporator coil, suitable for refrigerator of 165 to 260 ltrs any make size and type (in replacement) complete all as specified and directed.
Supply and fixing Relay, box type, suitable for refrigerator of any make 165 to 335 litres capacity (in replacement) fixed in repairs, complete all as specified and directed.
Supply and fix in repair magnetic beading for refrigerator of capacity 165 ltrs to 335 ltrs complete all as specified and directed.
Supply and fixing Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing one complete all as specified and directed.
Material and labour for preparing the old painted surface of refrigerator of capacity 165 litres to 350 litres and spray painting with synthetic enamel paint of approved colour complete all as specified and directed.
Supply and fixing Chiller tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity, all as specified and directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 165 to 260 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 260 litres complete all as specified and directed.
Supply and fixing Vegetable tray (in replacement) suitable for Refrigerator of any make, 165 to 260 litres capacity, complete all as specified and directed.
Supply and fixing in replacement condensing coil for refrigerator of capacity 165 to 260 Ltr complete all as specified and directed.
Supply and fixing Multi capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing in replacement Gasket, suitable for door of Refrigerator of any make, 165 to 350 litres capacity, fixed in repairs all as specified and directed.
Supply and fixing Timer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed .
Supply and fixing Copper capillary tube suitable for refrigerator including taking down existing unserviceable one, any description complete all as specified and directed.
Supply and fixing Thermostat, suitable for refrigerator of any make 165 to 350 litres capacity (in replacement) all as specified and directed.
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. for satisfactory functioning complete all as specified and directed. Note:Topping up of gas shall be measured and paid separately
Supply and fixing Filter of refrigerator including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Evaporator coil, suitable for refrigerator of 308 to 350 ltrs any make size and type (in replacement) complete all as specified and directed.
Supply and fixing in replacement of condensing coil for refrigerator of capacity 308 to 350 Ltr complete all as specified and directed.
Supply and fixing hermetically sealed new compressor (in replacement) for 308 to 350 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 308 to 350 litres complete all as specified and as directed.
Supply and fixing Starting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed
Supply and fixing Multi capacitors 4 µfd for cooling appliances including taking down existing unserviceable one all as specified and as directed.
Servicing the Voltage Stabilizer 0.5 KVA to 2 KVA single phase after replacing transformer, PCB, U/S electronic parts, setting/testing of buck/boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Supply and fixing Multi capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Over load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed..
Material and labour for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 308 to 350 litres including vacuuming and charging the refrigerant gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and directed. Note: Topping up of gas shall be measured and paid separately
Servicing the Voltage Stabilizer 4 KVA to 5 KVA single phase after replacing transformer, PCB,u/s electronic parts, setting/testing of buck/boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/180 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed . Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed .
Supply and fixing Door gasket (in replacement) suitable for lid of water cooler up to 150 litres capacity, complete all as specified and directed.
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water cooler of any make of 150/180 litres capacity, complete all as specified and directed.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 160 to 180 Litres capacity complete all as specified and directed.
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 150 litre/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 litres and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one all as specified and directed.
Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
Supply and fixing PVC drain out pipe 32 mm dia bore (in replacement) as per existing including providing necessary GI clamps, nut bolt etc.all as specified and directed
Supply and fixing ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing one all directed.
Supply and fixing Self closing push type tap 15mm dia made out of cast copper alloy chromium plated (in replacement) suitable for water cooler conforming to ISI mark, including testing and leak proof etc. complete all as specified and directed.
Supply and fix in replacement of gun metal gate valve 15mm dia including GI nipple including taking down existing one all as specified and as directed
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note:Topping up of gas shall be measured and paid separately
Material and labour for preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity all as specified and directed.
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc. (in replacement) suitable for water cooler of any make of 60/120 litres capacity, including taking down existing one all as specified and directed.
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 60/120 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed.
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note: Topping up of gas shall be measured and paid separately
Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour all as specified and directed.
Supply and fixing Electric condenser Fan motor, AC 230 volt, single phase with recommended RPM etc (in replacement) suitable for water cooler of any make of 40/80 litres capacity, complete all as specified and as directed.
Supply and fixing Evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified directed.
Supply and fix Stainless steel tray (in replacement) suitable for water cooler of 40/ 80 litres capacity all as specified and directed.
Supply and fixing hermetic sealed new compressor (in replacement) for water cooler 40/80 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed.
Supply and fixing Condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity (in replacement) complete all as specified and as directed.
Material and labour for preparing the old painted surface of the water coolers of capacity of 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed.
Material and labour for pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas and filling new compressor oil etc. complete for satisfactory functioning all as specified and directed. Note: Topping up of gas shall be measured and paid separately
Material and labour for repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed.
Supply and fixing Carbon (filter) 12” size incl taking down old unsv complete all as specified and as directed.
Supply and fix in replacement of filter for water cooler of any size any make complete all as specified and as directed.
Supply and fixing Multi capacitors 4.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Multi capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and charging of refrigerant gas R-134a to water cooler, refrigerator and deep freezer air conditioner of any type, make and capacity all as specified and directed. (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas filled.
Taking down carefully copper/aluminum point wiring (light, fan, Power) complete fittings such as switches , ceiling roses pendents , regulators sockets light fittings etc and making good disturbed surface of wall, floors , roof etc all as specified and directed.
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealed rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame , concealed in wall and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/Havells Note: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 116 here in before but for one light point controlled by one way switch.
All as per item No. 116 here in before but for one Exhaust fan/ceilling fan controlled by one by one way switch.
All as per item No. 116 here in before but for one bell point controlled by one bell push.
All as per item No.116 here in before but for one 3 pin socket outlet 5/6 Amp on the same board
All as per item No. 116 here in before but for one switch socket outlet 3 pin 5/6 Amps on independent board
All as per item No. 116 here -in - before but for One light point controlled by two, two way switches.
All as per Sl No 116 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor (FRLS) controlled by one 15/16A switch socket independently complete all as specified and directed.
Supply and Fix switch piano flush type 5/6 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 15/16 Amps 240 volts complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5/6 Amps 240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5/6 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 3 pin 5/6 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered switch socket outlet 3 pin 5/6 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5/6 and 15/16 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian
S&F fan regulator stepped type electronic for ceiling fan complete all as specified and directed.
S&F in repair Sub main wiring with 2 runs of single core, 4 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 4.00 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire alongwith PVC conduit /Casing capping shall be measured as one run length) Make : Havells, Polycab, Plaza
S&F factory made powder coated distribution board VTPN, 4 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB with fitting fixture complete all as specified and directed. Make : Indoasian/ Havells/ Legrand.
S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
Taking down of old U/S MCB DB TPN any type complete all as specified and directed.
S&F factory made powder coated distribution board TPN, 4 way double door MCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete complete all as specified and directed. Make : Indoasian/ Havells/ Legrand.
S & F TPN, MCB 40 to 63 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
M& L in repair PVC Casing & Capping medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed.
M& L in repair PVC Casing & Capping medium 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed.
S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 4"x 4" all as specified and directed.
S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 6"x 4" all as specified and directed.
S & F in repair Modular PVC box 1/2 module in the existing wall complete all as directed.
S & F in repair Modular PVC box 3 module in the existing wall complete all as specified and directed.
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including rigid non metalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame, concealed in wall and 1.5 sq mm multi stranded copper conductor FRLS cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/Havells Note: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 146 here in before but for one light point controlled by one way switch.
All as per item No. 146 but for One ceiling fan /exhaust point controlled by one switch one way 5/6 Amps and fan speed regulator
All as per item No. 146 here in before but for one bell point controlled by one bell push.
All as per item No. 146 here -in - before but for One 2/3 pin switch socket point controlled by 5/ 6 Amps switch on Independent board.
All as per item No 146 but for One socket outlet point 5/6 Amps 3 pin on same board.
All as per item No. 146 here -in - before but for One light point controlled by two, two way switches.
All as per item No.146 here -in - before but for One 3 pin switch socket outlet combination, 15 Amps, with cables 4 sq mm all as specified and directed.
Supply and Fix modular switch 1 way 5/6 Amp,1 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 1 way 15/16 Amp,1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular Socket,5/6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular Socket, 5/15/ and 6/16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 2 way 5/6 Amp, 1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian
S&F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directed.
Supply & fix of ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and as directed.
S & F of modular PVC White cover plate with frame, 2 module
S & F of modular PVC White cover plate with frame, 3 module
Supply and fix modular PVC White cover plate with frame,4 module
Supply and fix modular PVC White cover plate with frame,6 module
Supply and fix modular PVC White cover plate with frame,8 module
Supply and fix modular PVC White cover plate with frame,12 module
S&F in repair Sub main wiring with 2 runs of single core, 6 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 6.00 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire alongwith PVC conduit /Casing capping shall be measured as one run length) Make : Havells, Polycab, Plaza
S&F factory made powder coated distribution board VTPN, 6 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB with fitting fixture complete all as specified and directed. Make : Indoasian/ Havells/ Legrand.
S&Fdistribution board MCCB four pole, 160 Amp ultimate breaking capacity 25 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
Taking down of old U/S earth enclosure with MCB any type complete all as specified and directed.
S&F of Single pole and neutral enclosure with a two pin and earth plug and socket with single pole MCB 32 Amps complete all as pecified and directed. Make Legrand /Schneider /ABB
Supply and Fix triple pole and earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB 10A- 63 Amps with accessories complete all as specified and as directed. Make Legrand /Schneider /ABB
S&F in repair factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S&F in repair factory made powder coated distribution board SPN 6 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB SPN 240 volts upto 40 Amps 'C' series 10 KA breaking capacity complete fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian.
S&F in repair factory made powder coated distribution board SPN 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S&F in repair factory made powder coated distribution board SPN 12 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB SPN 240 volts 63 Amps 'C' series 10 KA breaking capacity complete complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian.
S & F MCB single pole 240 volts upto 40 Amps 'C' series 10 KA breaking capacity complete complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian.
M& L in repair PVC conduit medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed.
M& L in repair PVC conduit medium grade of size 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping complete all as specified and as directed.
S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 6"x 8" all as specified and directed.
S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 8"x 8" all as specified and directed.
S & F in repair Modular PVC box box 4 module in the existing wall complete all as specified and directed.
S & F in repair Modular PVC box box 6 module in the existing wall complete all as specified and directed.
S&F factory made powder coated distribution board VTPN, 8 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB with fitting fixture complete all as specified and directed. Make : Indoasian/ Havells/ Legrand.
M& L in repair PVC Flexible conduit of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /alluminium conductor complete all as specified and as directed.
M& L in repair PVC Flexible conduit of size 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /alluminium conductor complete all as specified and as directed.
M&L for Cutting chases, pinning in brick wall making good to facings where required in brick wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required in brick wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed.
S & F in repair 3.0 mm thick hylum sheet for fixing switches, sockets, regulators etc, including making arrangement for the same incl re-fixing the serviceable / new switches, sockets etc including fixing with new brass screws with cup washers complete of size 8"x 12" all as specified and directed.
S & F in repair Modular PVC box box 8 module in the existing wall complete all as specified and directed.
S & F in repair Modular PVC box 12 module in the existing wall complete all as specified and directed.
S & F in repair Modular blank plate one module complete all as specified and directed.
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
(c) The entire job will be carried out in AFTC, 2 DC area and Air Force stn Jalahalli
(d) Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
(e) Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility.
(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(h) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(j) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
Supply only gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed.
Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm complete all as specified and directed.
Supply only fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF
Supply only rotor of ceiling fan of any size complete all as specified and directed.
Supply only fan canopies for ceiling fan size of 1200mm/1400mm complete all as specified and directed.
Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed.
Supply only safety pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only 'U' clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed.
Supply only blades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed .
Supply only down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only outer body of ceiling fan of any size complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
Refixing existing serviceable ceiling fans 1200/1400 mm sweep servicing, painting. of ceiling fan with one coat of synthetic enamel paint by spraying including greasing/oiling, filling cavities with filler after cleaning all dust etc. complete all as specified and as directed by Engineer-in-Charge. Note : cost includes for replacement of rubber bush ,hanging hook with new cotter pins etc
Supply and fixing in replacement of unserviceable Ceiling fan 1200mm sweep, energy efficient ISI marked with star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and suitable flexible copper cable not less than 0.5 m long complete writing MES No. with synthetic enamel paint complete all as specified and directed. Make : Havells/ Bajaj/ Orient Note:- (a) Old Unserviceable ceiling fan shall be deposited to MES store yard by the contractor.
(b) The above job shall be carried out by a trained electrician having qualified in ITI (electrician Trade), documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work.
(c) The entire job will be carried out in AFTC, 2 DC area and Air Force stn Jalahalli
(dc) Defective unserviceable part like fan bush, bearing etc. will be paid under respective item here-in-after as supply only through proper documentation.
(e) Necessary T&P such as ladder, helper shall be contractor responsibility.
(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department.
(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(h) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
Supply only fan bush of suitable size for exhaust fan of the any sweep complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 250mm sweep including greasing complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 250mm sweep complete all as specified and directed.
Supply only 3.15 mfd capacity exhaust fan condenser complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 300mm sweep including greasing complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 300 mm sweep complete all as specified and directed.
Supply only 2.5 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 450mm sweep including greasing complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 450 mm sweep complete all as specified and directed.
Supply only 4 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed complete all as specified and directed.
Material and labour for winding of Exhaust fan 250 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
M&L for cutting of hole through stone wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
M&L in repair for stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/wooden beading fixed on wall including necessary fixing arrangement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsibility of the contractor
Supply and fixing Exhaust fan 250 mm sweep with louvers ,copper winding 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Material and labour for winding of Exhaust fan 300 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed.
M&L for in repair louver made of steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsible of the contractor.
Supply and fixing Exhaust fan 300 mm sweep with louvers ,copper winding 230/ 240 volt AC single phase Metal body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
M&L for cutting of hole through brick wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
Material and labour for winding of Exhaust fan 450 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
M&L Inspection, checking adjustments and minor repairs of storage water heater 25/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and re-fixing the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix.
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work.
The entire job will be carried out in AFTC, 2 DC area and Air Force stn Jalahalli
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
In case of minor defects, entire job shall be completed with in 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
Supply and fixing Heating element 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed.
Supply and fixing in replacement thermostat switch range of 30-80 degree celsius suitable for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed.
Supply and fixing in replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed.
Supply and fixing Indicator lamp for geyser 25/50 ltr capacity of colour green & red complete all as specified and as directed.
Supply and fixing PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe including taking down existing one complete all as specified and as directed.
Supply and fixing Outer body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enamelled paint including taking down existing one complete all as specified and as directed.
Supply and fixing Heating element 2.0 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity ,any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed.
Supply and fixing in replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixing in repair of heavy duty pin type fastener 4" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed. Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.
Supply and install water heater storage type (Geyser) vertical of capacity 25 Ltr, suitable for high pressure up to 8 bar powder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode, efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE 5 Star Rated with complete fittings/parts and accessories for fixing on wall/surface all as per site requirement and specified and directed . Note:- Old Unserviceable water heater shall be deposited to MES store yard. Make:- Bajaj / Racold / Havells
Material and labour for Grouting 4 Nos of M12 X100mm bolt in stone /brick masonry wall with 1:4 CM suitable for hanging geysers complete all as specified and as directed.
Supply and fixing in replacement brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed.
Supply and fixing in repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair Chlorinated PVC (CPVC)Gate Valve of size 20 mm dia, (ISI marked) complete all as specified and as directed.
Material and labour for painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
Supply and fixing in repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair Chlorinated PVC (CPVC) Gate Valve of size 25 mm dia,( ISI marked) complete all as specified and as directed.
S & F of bib tap cast copper alloy chromium plated, fancy type screwed down with screwed both ends for iron pipe 15 mm bore complete all as specified and as directed.
Supply and fixing 15 mm dia Stop valves, fancy type, chromium plated with long shank and cup(concealed type),screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
Material and labour for Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc including taking down existing one complete all as specified and directed.
S&F MS Plates Fe 410 -W (Gde- E- 250) quality- A (plain or chequered) channels, square cut or notched (ordinary and counter sunk forming holes, without any attachment complete all as specified and as directed.
S&F in framed work as in doors or gates of angle tubes or other section with gusset plates, rails, braces,guard bar etc., complete, to be prepared for hanging or sliding with and including hinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging; also fastening and fixing Fe 410 -W (Gde- E- 250) quality B complete all as specified and directed.
S&F Pre painted Coloured Galvalume roofing sheets 0.50 mm thick having Zinc aluminium alloy coating double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws and including dismantling of any type of old unserviceable sheets in roof coverings complete all as specified & directed.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified incl dismantling of old sheet complete all as specified and directed.
S&F 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
M&L for MS Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 complete all as specified and directed.
S&F Welded steel wire fabric cut to length, bent to shape required and tying with and including annealed mild steel not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members not exceeding 4kg/sqm complete all as specified and directed.
M & L Providing two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces all as specified and directed.
M&L for welding in repairs exceeding 2.5cm in length and thickness of metal to be welded in exceeding 9mm but not exceeding 20mm thickness complete all as spcified and directed.
Running welding in repairs thickness exc 6 mm but n exc 9mm, complete all as specified and directed.
M & L for 75 mm thick PCC type C1, 1:3:6 (20 mm graded stone aggregate) as in plinth protection finishing the surface even and smooth with using extra cement all as speecified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar (1:4) on brick or concrete surfaces of wall and finishing the surface even and smooth without using extra cement complete all specified and directed.
Material and labour for Preparation of new plastered surfaces of wall and applying two coats of cement based paint over one coat of primer complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, washing down, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of cement based paint complete all as specified and as directed.
Material and labour for Preparation of old plastered surface and applying one coat of exterior weather proof emulsion complete all as specified and directed
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, chajja, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed.
M & L Providing one coat of synthetic enamel paint on steel surfaces over 10 cm width or girth including preparation of old steel surfaces all as specified and directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L Pre-cast PCC 1:3:6 type C1 (using 20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 built in cement mortar of any description complete all as specified and as directed.
M&L for cement plaster rendering 10mm thick in CM 1:6 on fair faces of brickwork or concrete surface as on wall finished even and smooth without using extra cement and taking down old cement plaster on brick or stone walls, or concrete walls etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed.
M & L walling of random rubble, uncoursed, Bangalore type masonry well bonded bedded solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 all as specified and directed.
Fixing only walling random rubble, uncoursed, Bangalore type masonry (except stone) well bonded bedded solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 and including removal and refixing, built in cement mortar of any description as specified and directed. (Old stones shall be re-used)
Material and labour for keyed pointing in cement mortar 1:4 to random or polygonal rubble including racking out joints / points in cement mortar to squared rubble masonary coursed or un coursed etc complete, all as specified and directed.
S & F in repair concertina coil of 610mm dia (in stretched position) hot dip galvanised steel wire coated with CLR ante corrosive coating making diamond shape with the help of devotail clips (18 SWG) fixed over barbed with the angle iron the concertina coil is to be fixed with barbed wire at points where coil touched the bottom of barbed wire with the help of hog rings (14 SWG) complete,incl removal of old unserviceable coil of any description all as specified and directed.
S&F in repair galvanised two strand steel barbed wire 2.24 mm dia barbed wire with 2 mm barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised MS wire staples or steel pins etc as directed (each line wire to be measured)
Restraining and resecuring barbed wire including making good staples etc (each line wire to be measured) complete all as specified and directed.
M & L broken glass coping on top of walls in cement mortar 1:3 incl taking down old glass and removing the rubbish.
Renewing cement concrete tiles in patches, area n exc 1 sqm including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete all as directed. Note : The rate included for cutting out broken tiles, removing and cleaning loose tiles, preparing bed removing rubbish, removing and replacing old with new tiles to match, complete with all cuttings etc, that may be required. New tiles required is deemed to be included all as directed. The unit rate is also including necessary beding in cement mortor/Sand filling.
M&L in 300mmx300mmx25mm thick pre-polished cement concrete chequered tile jointed in neat cement slurry and pointed in white or coloured cement to match the floor, complete, all as specified and directed.
M&L for screedbed or bedding layer of mortar 20mm thick for laying floor finishes in CM 1:6 complete all as specified and directed.
M&L for broken stone boulders hard core of guage n.exc 63mm deposited spread and leveled laid in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for preparation of new/old any type of surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of floor guard paint over a coat of red oxide primer complete all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches bore of pipe 75 mm with PVC clamps and saddles including taking down old existing pipes and dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches bore of pipe 110 mm with PVC clamps and saddles including taking down old existing pipes and dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed
S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 75 mm complete all as specified and as directed.
S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 110 mm complete all as specified and as directed.
S & F in repairs 125/ 110 mm bore PVC (SWR) floor trap plain with grating incl jointing with solvent cement complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L for ceramic coloured tiles of size 350mmx250mm/ 300mm X 450mmx7 to 8 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc complete all as specified and directed.
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and supplying and fixing Joint free Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile of size n exc 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incuding screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:6) complete all as specified and directed.
Supply and fixing Anodized aluminium size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with hangers of GI wire of suitable dia (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and 6mm thick Non asbestos fibre cement building boards, fixed to sheet suitably placed in false ceiling grid made of Aluminium/G.I./ M.S.as per specification and drawing and including dismantling old unservicable ceiling board including frame of any type and description, complete all as specified and directed.
Dismantling posts or struts (wood, steel, or RCC) any section, any length n exc 5m including taking out embedded portion in concrete, brick work, masonry etc and all as specified and directed.
Excavating in post holes soft or loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm
S & F MS angle iron Hand rails, fencing posts, flat iron including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Supply only of chain link fencing MS galvanised square wire mesh of any size, dia of wire 4mm including line wires, to any type of standard rails, straining bolts, etc complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc inlcuding provision of binding wire and dismantling of old fencing wire mesh of any type etc all as specified and directed.
S&F MS round bars 10 mm dia and over Fe 290 (Gde - E-165) cut to length bent to shape required including cranking, bending spirally, hooping for columns, hooking ends all as specified and directed.
S &F in repairs Mild steel screw bolts (machine made) dia of neck 16 to 20mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, complete all as specified and directed.
Taking down and refixing precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion with grey cement and no pigment and including side kerb concrete, including removal and refixing all as specified and directed.
Site clearance by Scraping of grass/wild growth/trees cutting n.exc 0.30m girth etc in soft/loose soil by manually/mechanically including removing of rubbish from the site to a distance exc, 250m but n. exc 500m and deposited where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed
Demolition cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed
M & L for 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone agg) as in Hard standing etc. with , spike rolling ,or making impression of expanded metal, while the concrete is green including complete all as specified and directed.
M&L PCC (1:4:8) type D2 using 40mm graded aggregate 75mm thick as in sub base of floor finished even and rough to receive top layer all as specified and directed and demolition of old concrete (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment all as specified and directed.
M & L for Sand filling under floors or in foundations including watering and consolidation and all as specified and directed.
Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the grass weeds etc in the sub station yards after removing stone aggregate aside all as directed at site including setting / spreading back the aggregate complete all as specified and directed at site. Note:- (i) Additional stone aggregate required shall be measured and paid separately under relevant items of this schedule. (ii) The rate also deemed to be included for labour (iii) The sub station yards shall be kept clean through out the contract period by removing the grass/weeds as many as times required depending on the growth of the grass. (iv)The rates shall be deemed to includes the cost of removing two time the grass,weeds,debris,excess soil etc to a distance not less than 50 M and keeping the excavated surface clean and levelled all as directed.
Supply and spreading stone aggregate of size not exceeding 40 mm spread and leveled in layers not exceeding 15 cm to a true surface of broken stones for transformer and pole structure area all as directed
Supply and fixing as in repair HT tape roll 35mm width Appx 5 mtr length all as specified.
Attending complaints for non-functional/ unserviceable street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillars etc) by deploying technically qualified and experienced technicians to find out defects and taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tape to insulate the LT joint etc and testing complete all as specified and as directed at AF Station Jalahalli.
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work.
Contractor has to ensure serviceability of all Street/ Security Lights in AFS Jalahalli on Daily basis in any weather condition at their own arrangement.
Contractor or his Authorised Representative has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very regular basis. (Every succeding day)
A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User along with Contractor or his authorised Representative.
Contractor has to arrange own moveable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account.
Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipment's to remove the breakdown. Fault will be intimated through Telephone/ SMS.
Contractor shall provide conveyance to the employed labour for maintaining the services without any extra cost to department.
Vehicle mounted ladder for maitenance services shall be provided by the contractor at no extra cost to department.
Material required for the repairing of the lights shall be measured and paid separately under respective item(s) . But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the lights fittings shall deemed to be included in the rate quoted.
Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the tradesmen deployed for providing the services and department will have no liability for any type of accident. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this account.
All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
Attending and repairing complaint for one light of any type shall be measured and paid as one Job.
Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Charge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
The decision of the Accepting Officer in this regards shall be final and binding.
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity upto 36 watt LED fittings complete all as specified. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 40 to 45 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 60 to 75 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 80 to 100 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only electronic controller with accessories (LED outdoor Driver) of suitable capacity of 120 to 150 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only the electronic controller with accessories (LED outdoor Driver) of suitable capacity of 200 watt LED fittings complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply only PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Finolex or equivalent
Supply and fix digital timer switch 24 hrs including taking down of old one complete all as specified and as directed. Make:- Legrand /Indo Asian /L&T
Supply and fix as in repair NO/NC of capacity suitable for 32-40 A contactor including taking down of old one complete all as specified and as directed . Make:- Legrand /Indo Asian /L&T
Supply and fixing the surge protection device 5KV voltage compatible with industrial and out door type LED fixtures including taking down of old one complete all as specified and directed. Make - CG/Phillips/Bajaj or equivalent as per site requirement
Supply and fix contactor of capacity 32- 40 A 3 Pole 415 V with 2NO+2NC including taking down of old one complete all as specified and as directed .Make:- Legrand /Indo Asian /L& T
Supply and fix MCB 40 Amps, TP, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: , including taking down of old one complete all as specified and as directed and directed. Make:- Legrand /Indo Asian /L& T
M&L for wiring of unserviciable Timer panel box and replacement of existing size of copper wire with copper lugs and other connected items complete all as specified and as directed
Material and labour for applying one coat of cement base paint to PCC/RCC pole 7/9.0 metre long after scraping / brushing and cleaning the pole and street light bracket to be painted with one coat of Aluminium paint. Cement base paint shall be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white with synthetic enamel paint (30 Cms Each) Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete, all as specified and directed.
Material and labour for Painting of steel tubular pole 7/9.0 metre long, by applying one coat of aluminium paint after scraping / brushing and cleaning the rust on pole and street light bracket. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white with synthetic enamel paint (30 Cms Each). Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete all as specified and directed.
M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L RCC M25 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, lintel beams etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for TMT bars 10mm dia & over cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip with deep quality confirming to FE 500/FE 500D complete all as specified and directed.
Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 140x140x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32 No including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed.
Supply & fix PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Finolex
Supply and fix in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed.
Supply and fix in repair of LED street light 45/48 Watt fitting, environmental friendly long life, made up of pressure die cast aluminium housing with mid power LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. Make:Halonix/Philips/CG/Bajaj/Surya
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity. The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :-
(a) TPN MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No. (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, C&S Havells) (b) Supply Resign cast CT'S - set of 3 (c) GSM based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 32 Amps -02 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 06 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 Amp rating with brass contacts for INPUT/ and 63 Amp for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring 10 Sqmm flexible.
Supply and fixing LED flood light 70/50 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down of old unserviceable fitting of any capacity. Make : Halonix/Philips/CG/Bajaj/Surya
Supply and fixing LED flood light 100 watt 230 V AC outdoor type including necessary bracket with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down of old unserviceable fitting of any capacity. Make : Halonix/Philips/CG/Bajaj/Surya
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth and getting out in soft/lose soil , complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed.
Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
Material and labour for well burnt bricks ‘B’ class as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed. (iii) Removing excavated material out side MD land. (iv) Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Material and labour for 4 core 6 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells/ Polycab/ RPG Asian
Material and labour for 4 core 10 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 4 core 10 Sqmm to 16 Sqmm, complete all as specified and directed.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 25 Sqmm to 50 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed.
Supply and fixing in repair LED flood light 150 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lamp Protection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj /Surya
Supply and fix in repair Time switch Digital 24 hour, 440 V three phase with contactor TP of rating 32 Amps and MCB TPN of rating 40A fitted in steel enclosure with necessary accessories to fixing RCC/steel tubular pole including bracket, nuts, bolts, washers etc. and making all necessary connections through connectors complete all as specified and as directed. Make : L&T/ Havells/ Indoasian
Supply and fixing in repair IP65 rated LED Bollard with robust design and efficient light distribution 18 watt on existing pipe of any size and height with all accessories prewired fixed with FI clamps nuts bolts etc., including taking down existing fittings all as specified and directed Make : Crompton or equivalent in Halonix/Bajaj/ Philips
Supply, installation, commissioning and testing of floor mounted, free standing OEM made type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of CPRI approved IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 630 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate for bedding upto a height of 45 CM above ground level, complete all as speified and directed and comprising of the following:-
Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 300x200x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed.
Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 60 to 72 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj/Surya
Mateial and labour of new octagonal Hot Dip GI street light pole of single section 3 mm thick having integral junction box with weather proof door arrangement at 500 mm height from base plate (size of the door shall be of 100 x 500 mm with gasket) having pole size of bottom dia 130 mm & top dia 70 mm, PCD 220 mm, 7.0 mtr height with base plate of size 220x 220 x 12 mm mounted on 4 Nos M 20 x 700 mm 'J' shape GI Fdn bolt, nut and washer complete including necessary earth work, excavation, foundation work by providing PCC 1:3:6 using 20 mm stone aggregate , provision of 1 No MCB SP 6 A rating in the junction box, necessary connector arrangement along with 1 No single arm 1000 mm long GI Street light bracket complete all as specified. Note:- Excavation, earth work, sub mains and RCC foundation will be measured and paid seperately under relevent item of this schedule.
Supply and fix in repair LED flood light fitting 200 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 200W etc complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix/Surya
Supply and fix in repair LED flood light fitting 250 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 200W etc complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix/Surya
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 12 KW 3 phase 32 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor. Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1 for grouting of base including taking down unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, Ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.The panel should have three operation mode :-1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed.
(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) Gsm based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 03 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible.
Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.
Supply only of GI pipe light grade for cable protection of size 50 mm bore with fittings, complete all as specified and directed.
Material and labour for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size upto 3.50 core 25 Sqmm to 35 Sqmm, complete all as specified and directed.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tape etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box, complete all as specified and as directed for the cable size from 95 Sqmm to 150 Sqmm 3.5 core of underground LT armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall deemed to be included in the unit rate quoted.
Supply, installation, commissioning and testing of floor mounted, free standing OEM made type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of CPRI approved IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate for bedding upto a height of 45 CM above ground level, complete all as speified and directed and comprising of the following:-
Supply and fixing in repair Round spherical garden lighting, post top lantern having B22 holder suitable for LED bulb 10 watt, 220 volt,50HZ,IP65 including suitable of GI tubing ,length as per site requirement on gate pillars/ garden lights for fixing the lamp, wiring with 1.5 Sqmm PVC insulated stranded copper conductor including PCC work for fixing, of light fitting complete all as specified and directed.Make: Philips/ Havells/Bajaj/CG.
Supply and fix in repair LED 40 watt Post top energy saving environmental friendly ,design with symetrical light distribution, clear landscape luminair(CDL) made in cast aluminium spigot housing and IP 65 Protection all as directed Make - Philips /Bajaj/Havells/CG
Taking down unsv funnel of any type and size, supply and fixing in repair GI funnels for earthing, complete all as specified and as directed.
S&F in repair PCC earthing pit of outer size 450X450 X300mm and inner Size 350X350X 300mm RCC pit cover of required size with handle arrangement including necessary earth work complete all as specified and as directed .
Material and labour for resistance reducing earthing liquid certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A for improvement of earthing resistivity complete all as specified and directed.
Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mmx25mmx3mm of 450 mm long to be fixed to ground by means with necessary cement concrete and painting with two coats of synthetic enamel paint over a coat of red oxide primer, writing earth reading and connected items like painting of panel etc, and necessary excavation and earth work including taking down old, complete all as specified and as directed.
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
M&L in repair Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit, including taking down old u/s earth pit cover, complete all as specified and directed.
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified and directed.
Material and labour for Brazing of copper for continuity, complete all as specified and as directed.
Material and labour in repairs Galvanised iron Earth strip of size 32 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
Taking down existing GI earthstrip 25x3mm thick as earthing lead with its accessories and re fixing to wall/roofs etc. drawn in conduit/GI pipe etc all as specified and directed. Note:- Unit rate is deemed to be included for old broken insulators/ clamps to replace with new insulators of existing size as per site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.
Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal. head screw, complete all as specified and directed.
Taking down of serviceable aluminium strip 25x3mm and refixing the same with epoxy based insulator/post insulator/spacer for down/ lightening conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut and bolt, gutties, screws etc.on wall /roof including necessary fixing arrangement up to height 20 mtr complete all as specified and directed.
Supply and fixing in replacement of aluminium strip 25x3mm fixed with insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut and bolt, gutties, screws etc,.on wall /roof including necessary fixing arrangement up to height 20 mtr complete all as specified and directed.
S&F in repair post insulator for earthing strip above fourth floor roof top/ 6-9 Mtr wall complete all as directed.
S&F in repair insulator for earthing strip laid in floor/ roof /wall complete all as directed.
Note :- An amount of Rs 2,49,201.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
8333GENPAGE.pdf
Tender Documents • 0.56 MB
BOQ_854248.xls
BOQ • 0.56 MB
8333PS.pdf
Additional Documents • 0.90 MB
Download all tender documents and submit your bid