Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹48.0 L+₹2.8 L (6.12%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹48.4 L+₹3.1 L (6.94%)Rejected-Finance 1286 TOTA RAM KI DHANI JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹52.9 L+₹7.7 L (17.0%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L4 | Rejected-Finance Not being lowest | |
| 5 | Rejected-Technical 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | - | Rejected-Technical Rejected due to OVER LOADED and below one class |
Tender Value
₹48.6 L
EMD Value
₹97,200
Closing Date
20 Jul 2024, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
PROVN OF SECURITY FENCE (800 METER) WITH 02 IRON GATE AT KISHANGARH AND WAITING ROOM WITH TOILET AT MIL STN JAISALMER UNDER GE (A) JAISALMER
2024_MES_659804_1
8366/24-25/E8
Open Tender
Civil Works
Item Rate
270 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹97,200
Yes
27 Nov 2024
14 Jun 2024
23 Jul 2024
14 Jun 2024
20 Jul 2024
5 Jul 2024
Amount
Excavating in post holes (or similar holes) in hard/dense soil, each not exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50 Mtr and making good surface all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified & directed by Engineer-in-charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified & directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge.
Removing excavated material soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified & directed by Engineer-in-charge.
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified & directed by Engineer-in-charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footing foundation beams, plinth beam, base for coulm, etc basement slab under ream piles and mass concrete complete all as specified & directed by Engineer-in-charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in Col, Pillars post and struts etc complete all as specified & directed by Engineer-in-charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in beams, cantilever, bressummers, lintel over 1.5m span etc complete all as specified & directed by Engineer-in-charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate)e as on Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs andd in shelves and the like complete all as specified & directed by Engineer-in-charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as for chajjas complete all as specified & directed by Engineer-in-charge.
Use and waste of formwork to sides of concrete foundation, footing, base of column, raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter to rough finish surface of concrete flat complete all as specified & directed by Engineer-in-charge.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (Horizontal or sloping) to rough finish surface of concrete flat. complete all as specified & directed by Engineer-in-charge.
Use and waste of formwork to soffits of floor or roof beams, beam haunching, grider, bressumber, lintels, cantilever, sleves including supports, over hang etc also splay between floor and beams to rough finish surface of concrete flat. complete all as specified & directed by Engineer-in-charge.
Use and waste of formwork to sides of pillars, posts, struts piers, columns and stanchion to rough finish surface of concrete square, rectangular or polygonal. complete all as specified & directed by Engineer-in-charge.
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified & directed by Engineer-in-charge.
Use and waste of formwork to edges of concrete flats ,treads, break in floors window cills, concrete railing , opening in concrete wall, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide to rough finish surface of concrete flat. complete all as specified & directed by Engineer-in-charge.
M&L TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified & directed by Engineer-in-charge.
Ditto as item No 23 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified & directed by Engineer-in-charge.
M&L for modular brickwork with flyash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
M&L Rendering 15 mm thick cement plaster in CM 1:6 on fair faces of brick/concrete work surfaces finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L rendering 5 mm thick on fair faces of concrete surface in ceiling in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L Rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete work surfaces finished even and smooth without using extra cement including water proofing compound complete all as specified & directed by Engineer-in-charge. NOTE: Water proofing compound shall be measured and paid seperately.
Supply only integral water proofing compound complete all as specified & directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces and applying three coats of white wash on ceiling complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified & directed by Engineer-in-charge.
M&L preparing of plaster surface and apppying of two coat of oil bound distemper on newly plaster surface over applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified & directed by Engineer-in-charge.
M&L for 75 mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing path & finishing the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
M&L 25 mm thick plain cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in floor for receiving screed bed complete complete all as specified & directed by Engineer-in-charge.
M&L 75mm PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection and hard standing including providing contraction joints with wooden spacers complete all as specified & directed by Engineer-in-charge.
M&L for Granite 20mm thick table rubbed and polished in steps, jambs, pillars, window cills, cooking platformsand like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixure of pigment to match with marble shade of Makrana white complete all as specified and as directed by the Engineer in Charge
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick area of each tile not exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM 1:6 provided with 3mm thick joints accomplished by providing PVC spacers and joints filled with epoxy filling complete all as directed (size 600mm to 600mm) complete all as specified and directed by Engineer-in-charge.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick area of each tile not exc 0.36 sqm in Skirting/dado over 10mm thick backing coat in CM (1:4) provided with 3mm thick joints accomplished by providing PVC spacers and joints filled with epoxy filling complete all as specified and directed by Engineer-in-charge.
M&L for non skid ceramic coloured tiles of size 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified & directed by Engineer-in-charge.
S&F glazed ceramic coloured tiles of size 350 x 250mm x 7mm /450mmx350mmx7mm thick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including rendering 10mm thick as backing coat in CM (1:4) complete all as specified and directed by Engineer-in-charge.
M&L 3mm thick sheet figured glass pin head type and glazing with oil putty in square n. exc 0.50 sqm each pane. complete all as specified and directed by Engineer-in-charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified & directed by Engineer-in-charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 150 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed by Engineer-in-charge.
S&F 150 mm long Aluminium handles, cast type, anodised complete all as specified & directed by Engineer-in-charge.
S&F butt hinges, extruded alluminium, with mild steel hinge pin, bright polished and fixed, type 100mm size C21 complete all as specified & directed by Engineer-in-charge.
S&F 200mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & directed by Engineer-in-charge.
S&F 15mm bore steel water tubing (ISI marked) medium grade galvanised, with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore steel water tubing (ISI marked) medium grade galvanised, with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F steel water tubing (ISI marked) medium grade galvanised, 50mm bore with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F for light colour vitreous china WHB Thin Rim Table top of size 495 x 395 x 150 mm (minimum) including CP waste pipe etc and making holes in the counter for fixing basin and mixer complete all as specified and directed by Engineer-in-charge. (Make : Jaquar JDS-WHT-25909 or equivalent in Appx 'C'list of makes)
S&F Hall stall vitreous china urinal white colour of size 710 x 480 x 300 mm Ist quality with flushing valve for urinal with complete kit including CP waste with PVC down pipe upto floor level as per urinal required size complete all as specified and directed by Engineer-in-charge. (Make : Jaquar Cat part No. URS-WHT-13261 or equivalent in Appx 'C'list of makes)
S & F for wall mounted vitreous china wash down water closet (pedestal pattern) pan white with “P” or “S” trap including concealed flushing cistern 10 lts capacity with plug , handle etc. connection to drain or outgoing and to syphonage pipe complete all as specified and directed by Engineer-in-charge. (Make : Jaquar CAT part KUS-WHT-35953BIUFSM or equivalent in Appx 'C'list of makes)
S&F CP brass Central Hole Table Top Wash Hand Basin mixture fixed to GI pipe complete all as specified and directed by Engineer-in-charge. (Make-Jaquar cat part No FLR-CHR-5167NB or equivalent in Appx 'C'list of makes)
S&F bib taps, copper alloy two way chromium plated suitable for 15mm bore pipe with captain head complete all as specified and directed by Engineer-in-charge. (Make-Jaquar cat part No FLR-CHR-5041N or equivalent in Appx 'C'list of makes)
S&F bib tap, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F stop valve, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for 15 mm bore iron pipe or for union complete all as specified & directed by Engineer-in-charge.
S&F (Health facut) with 1 Mtr flexible tube with wall hook bracket etc, complete set of superior quality complete all as specified and directed by Engineer-in-charge. (Make : Jagur Cat No ALD-CHR-573 or Marc/ESS-ESS or equivalent in Appx 'C'list of makes)
S&F for CP Brass toilet paper holder with wall hook bracket etc, complete set of superior quality complete all as specified and directed by Engineer-in-charge. (Make : Jagur Cat No ACH-CHR-1153S or Marc/ESS-ESS or equivalent in Appx 'C'list of makes)
S&F Looking Glass mirror (size 1500 x 1200 mm) 5 mm thick with anti crack film on back and pencil polished glass edges fixed on all with brackets complete all as specified and directed by Engineer-in-charge.
M&L for Anodised aluminium frame powder coated for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-charge.
S&F for Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete complete all as specified and directed by Engineer-in-charge.
S&F for anodised aluminium powder coated window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-charge.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed by Engineer-in-charge.
M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engineer-in-charge.
S&Fof 5.5 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares exceeding 0.50 Sqm in each pane complete all as specified and directed by Engineer-in-charge.
S&F aluminium 4 levers rebated mortice lock, vertical type, size 75 mm complete all as specified and directed by Engineer-in-charge.
S&F 15 mm dia Stop valves, cast copper alloy screwed presure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed but fancy type chromium plated complete all as specified and directed by Engineer-in-charge.
S & F 450 mm long PVC connection pipe of 15mm bore with PTMT nut at both ends complete all as specified & directed by Engineer-in-charge.
S&F tubular towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges fixed with chromium plated brass screws complete all as specified & directed by Engineer-in-charge.
S&F Sand Cast iron soil, waste and vent pipes 100mm dia in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.
S&F Sand Cast iron soil, waste and vent pipes 75 mm dia in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.
S&F Sand Cast iron soil, waste and vent pipes 100mm dia in any length with or without ears, with cement joints, Fixed to wall complete all as specified & directed by Engineer-in-charge.
S&F Sand Cast iron soil, waste and vent pipes 75 mm dia in any length with or without ears, with cement joints, Fixed to wall complete all as specified & directed by Engineer-in-charge.
S&F CI Bends 100 mm dia (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified & directed by Engineer-in-charge.
S&F CI Bends 75 mm dia (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified & directed by Engineer-in-charge.
S&F CI 100mm Bends (any radius) with duck's foot or heel rest complete all as specified & directed by Engineer-in-charge.
S&F cast iron 100 mm dia P or S trap complete all as specified & directed by Engineer-in-charge.
S& F Cast iron 75 mm cowl complete all as specified & directed by Engineer-in-charge.
S&F 75 mm nahani trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) etc complete all as specified & directed by Engineer-in-charge.
M&L for APP based polymeric membrane minmum weighing 3 Kg/Sqm and minmum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) including priming of surface by forced application including 10mm thick 1:3 CM with water proofing compound complete all as specified & directed by Engineer-in-charge.
M&L Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat complete all as specified & directed by Engineer-in-charge.
S&F for roller blinds of fibre including rolling mechanism up & down, right & left, brackets for fixing to windows complete all as specified & directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks 1000 litres capacity triple layered (White) cylindrical vertical with closed top hoisted and 20mm ball valves high pressure with polythene float and flynut complete fixed in position complete all as specified & directed by Engineer-in-charge.
Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed by Engineer-in-charge. Note :-Fixing only chain link fencing, steel round bars for protection will measured and paid separately.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire complete as specified & directed by Engineer-in-charge. Note :-Supply only chain link fencing will measured and paid separately.
S&F galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified & directed by Engineer-in-Charge. Note :- Eeach line wire to be measured.
S&F razor type concertina coil ( two coils) SG Hot galvanised spring tensile wire of DTS 145 to 150 kg /sqm zinc coated 250-300 gm/sqm and dia of coil when unstreached 600 mm having minimum number of circle 10 per RM hot dia galvanised razor ribbon type of size 0.50 mm thickness 19 mm width before warpping on central core wire fixed with GI 11066 mm thick clips and securing nut bolt held Z coils together and extra two row panels wire of guage complete all as specified and directed by the Engineer-in-Charge.
S & F for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confiorming to round bars Fe-410-W (Gde.E-250) quality A- or Fe 290 (Gde-E-165) complete all as specified & directed by Engineer-in-Charge.
S& F for mild steel work post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed by Engineer-in-charge.
S&F framed work such as grills, gratings, etc with ends of bars shouldered and / or riverted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, raillings, frame work of water tanks and similar work confirming to Fe-290 grade E-165 complete all as specified & directed by Engineer-in-charge.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm but not.exc 10 cm long, diameter of neck 11 to 15mm complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
M&L plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straigth or curved) complete all as specified & directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe all as specified & directed by Engineer-in-charge.
M&L for mild steel TMT bars 6mm to 8mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge.
M&L for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc., complete for 10 users complete all as specified & directed by Engineer-in-Charge.
M&L for Soakage well excavation in any type of soil foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M25concrete including intercepting chamber and screen chamber made of brick masonry in CM, RCC Cover Slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2m dia x 3M effective depth complete all as specified & directed by Engineer-in-charge.
M&L for modular brickwork with flyash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4) complete all as specified & directed by Engineer-in-charge.
M&L for plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in surface channels and drains etc like including necessary forms/ moulds complete all as specified & directed by Engineer-in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified & directed by Engineer-in-charge.
M&L for precast cement concrete (1:2:4) type B- 1(using 20 mm graded stone aggregate) as in landings, shelves, cover slabs (manholes etc) and similar articls with plain faces, set in cement morat (1:6) with and including necessary form work complete all as specified & directed by Engineer-in-charge. Note :- Reinforcement shall be measured and paid separately.
M & L for 150mm bore dia reinforced cement concrete pipes, class NP3, laid and jointed with collars complete all as specified and directed by Engr-in-Charge. (Note :- Excavation and earth work shall be measured and paid separately.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in-charge. Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement.
M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for conduits and IS : 3419 - 1976 for conduit accessories) with terminated to suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- Note : Modular switch and socket shall be measured and paid separately.
(a) One light point controlled by one switch.
(b) One ceiling Fan/Exhaust fan point controlled by one switch.
(c) One 2/3 Pin socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No 105.00 above but with copper conductor cable 4 sq mm for 3 pin socket outlet, 15 Amps including provision of 4 sq mm PVC insulated copper conductor cable as earth continuity condutor on independent board complete all as specified & directed by Engineer-in-charge.
S&F modular switch one way 6 A, 1 module complete all as specified & directed by Engineer-in-charge.
S&F modular socket 6A-2/3 pin combined 2 module complete all as specified & directed by Engineer-in-charge.
S&F modular switch socket combined 16 A, 5 pin, 3 module complete all as specified & directed by Engineer-in-charge.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete all as specified & directed by Engineer-in-charge.
S&F modular fan regulator, 120 W 2 module on the existing sheet etc as required complete all as specified & directed by Engineer-in-charge.
Supply and fixing 415V 10K A 'C' curve miniature circuit breaker (MCB) of tripple pole and neutral rated capacity TPN 40 To 100 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 6 Amps to 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
S&F LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten, extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver, optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge.
S & F surface and wall mounted LED tube light along with fixture, 4 ft, 20 W, extruded aluminium housing provided for efficient heat disspation with polycarbonate ,operating voltage 240 V, 50 HZ, AC supply and operating tempureture 0 to 50 C, power factor >0.9, lumen output > 2000 and provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified & directed by Engineer-in-charge.
Supply and fixing of building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lighting souce and PC cover having TOP opening sepreate drive compartment with bracket of GI pipe medium grade of 40mm bore dia, 1.2 meter in length, MS clamps made of FI 40 mm x 6mm incl nuts, bolts & washers including two coats of synthetic enamel paint over a coat of zink chrome primer and connecting complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB TPN 4 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
S&F fans ceiling fans complete with three blade, down rod, accessories 230 V, 1200 mm sweep necessary connecting cable recommended / provided by manufacturer complete all as specified & directed by Engineer-in-charge.
Supply & fix steel body heavy duty exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified & directed by Engineer-in-charge.
Supply & fix water heater storage type (Geyser) vertical type, inner container of capacity 25 ltrs, electrically operated, AC 230 Volts, BEE 5 star rated. including required Nos of fashner nuts required suitable size fixed in brick wall complete all as specified & directed by Engineer-in-charge.
Supply & fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified & directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom, burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron wire 4mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 122.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply, laying, testing and commissioning of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size of cross sectional aera 35 Sqmm 3½ core with cable lugs, gland, cable termination box etc complete all as specified & directed by Engineer-in-Charge. Note :- Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. (Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB Tripple pole and netural rated capacity 100 Amps, 415 volts breaking capacity 10 KA complete all as specified and directed by Engineer-in-charge.
S&F 50 mm bore GI tubing "light garde "in treches on pole for protection of cables complete all as specified & directed by Engineer-in-charge.
S&F gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the size 20 mm bore with fittings and accessories. ISI marked and as per IS 14846 complete all as specified & directed by Engineer-in-Charge
S&F gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the size 50 mm bore with fittings and accessories. ISI marked and as per IS 14846 complete all as specified & directed by Engineer-in-Charge.
M&L for cutting the existing pipe and inserting Tee 50x50x25mm complete all as specified and directed Engg-in-Charge.
M/s Ramniwas Bishnoi (BID ID -3058079)
GEMRARAMCONTRACTOR (BID ID -3067228)
M/s Shri Inder Construction Company (BID ID -3051255)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .