Provision of CCTV cameras to monitor common areas of Retiring rooms and ticket counters at all major locations of Moradabad Division.
04-Tele-CCTVRRoom-MB25-26~NR
04-Tele-CCTVRRoom-MB25-26
Open
Works - General
12 Months
Moradabad, Uttar Pradesh
₹0
₹2.6 L
8 Jan 2026
18 Dec 2025
25 Dec 2025
01-Provision of CCTV cameras to monitor common areas of Retiring
Supply of OFC single mode 6 Fibre armoured cable. inspection by consignee.
Supply of STP ( Shielded twisted paired) CAT-6 Cable. inspection by consignee.
Supply of HDPE Pipe of 40 mm dia as per RDSO spec. RDSO/SPN/TC/45/ 2013, Rev. 2.0 Amendment-1 & amendment- 2 or latest with end cap provided with each drum. inspection by RDSO.
Laying of HDPE duct in the trenches and in the protective works already provided including in HDD portion and supply pulling of Nylon rope through it at different places as per direction of engineer in charge or site engineer.Inspection by site engineer
Drawing / Blowing of Optical Fiber Cable in PLB HDPE Duct. inspection by consignee.
Trenchless Trenching/ boring (by using HDD or manual pushing method ) in 06 congested area,culverts, track crossing and road Crossing, depth of trenchless trenching shall not be less than 1500 mm from bottom of Rail Flange/ Road Level for 40mm HDPE DUCT (Supply and laying of HDPE Duct is covered separately). Inspection by site engineer.
Supply of Full HD Fixed bullet type/Dome type IP colour camera along with suitable housing, mounting arrangements and all accessories required for fixing and as per RDSO Specification No. RDSO/SPN/TC/65/2021, Rev6.0or latest. inspection by RDSO.
Installation, Testing & Commissioning of Full HD Bullet/Dome IP Colour camera along with the mount as per RDSO Specification No. RDSO/SPN/TC/65/2021, Rev6.0 or latest. All the accessories and fixing materials including mount required for this installation are to be supplied by contractor within the same cost. Inspection by site engineer.
Supply, installation, testing, wiring & commissioning of Full HD Resolution Large Format Display LED Monitor Screen Size 55"(inches) or larger as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest. inspection by consignee.
Supply and Installation of 32 Channel 4K NVR with 4 HDD NVR supported of 10TB.Specification as per. RDSO/SPN/TC/65/2021 Version 6.0 or Latest. inspection by RDSO.
Supply of Server Hardware for Video Management and recording along with all accessories as perRDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest. inspection by RDSO.
Installation, Testing & Commissioning of Server for Video Management and recording along with all accessories as per RDSO Specification NoRDSO/SPN/TC/65/2021 Version 6.0 or latest. Inspection by consignee
Supply, Installation, testing, wiring & commissioning of PC Work station hardware as 13 per clause No 11.0 of RDSO Specification NoRDSO/SPN/TC/65/2021 Version 6.0or latest.for viewing monitoring and system management with digital keyboard and loaded with GUI client software feature as per clause no18.2.0 of RDSO/SPN/TC/65/2021Version 6.0 or latest. Software licenses conditions as per clause No20.0 of RDSO/SPN/TC/65/2021Version 6.0 or latest. inspection by RDSO.
Supply, Installation, testing, wiring & commissioning of external storage with 14 (Hardware and Software) with minimum 240TB RAW usable storage capacity with all accessories as per clause 12.0 asper RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0or latest. inspection by RDSO.
Supply, Installation, Testing & Commissioning of Aggregate Switch ( 24xG SFP ports and 4x10GSFP+ ports) as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest. inspection by RDSO. 1091993.4
Supply, Installation, Testing & Commissioning of Distribution Switch 48 Nos. 10G, 6 Nos. 40G ports equipped with minimum 02 Nos. - 40G SM Fiber Modules Redundant Power Supplies,. inspection by RITES.
Supply of single mode single fibre 10G SFP+ module compatible with Layer 3, Layer 2 and Aggregates Switches. inspection by consignee.
Installation, testing and commissioning of single mode single fibre 10G SFP module compatible with Layer 3, Layer 2and Aggregate switches. inspection by consignee.
Supply, installation, testing, wiring & commissioning of Video Management & 19 Recording software with license as per RDSO Specification No. RDSO/SPN/TC/65/2021 Version 6.0or latest amendment. (Per camera license means video management(Viewing) at multiple locations such as station, RPF post & server room by same license). direction by site engineer. Inspection by RDSO
Supply and installation of 8 TB surveillance Hard Disk(internal) used for NVR. inspection by consignee.
Supply of 3 Core x 2.5 Sq mm multistrand copper conductor, PVC insulated, armoured power cable confirming to IS:694 part I or latest). inspection by Consignee.
Supply, Installation, Testing and commissioning of 2KVA on line UPS with 3200 VAH back up. inspection by RITES.
Supply, Installation, testing & Commissioning of UPS (online) 5KVA as per RDSO Specification no. RDSO/PE/SPEC/PS/0023- 2001(Rev-0) Amendment no. 2 or latest suitable for single phase AC supply and single phase AC output, Floor Mounted Type backup time 120Minutes. Inspection by RDSO
Supply and installation of 19" 42U Rack with all accessories like Electrical fitting, Fan tray, Patch Panel, cable manager, SPD for housing IP storage unit. Inspection by consingnee
Supply of 9U Rack Enclosures for networking/ sever rack. inspection by consignee.
Floor/wall cutting and refilling the same including supply and laying of 25 mm PVC pipe ISI medium. inspection by consignee.
"Excavation of cable trench at platform/concreted surface of 120 mm wide &300 mm 27 deep with marble cutting machine as per approved cable plan at place where cess for mation width does not allow, standard width/depth of trench to be dug for safety reason .Restoring surface to normal condition as prior to trenching required material will be supplied by the contractor according to excavated surface. Inspection by site engineer.
Preparation of drawing mentioning the location of cameras wiring diagrams showing clearly the STP CAT-6, OFC, Power cable OTDR test reports of OFC cable, earth resistance test 28 reports, technical details of servers, switches, work stations, media convertors, storages and submission in soft as well 3 sets in printed to the consignee. A diagram of camera location either in pictorial view or in descriptive manner as decided by the officer in-charge should be prepared on a suitable sheet and displayed in RPF CCTV control room. Inspection by consingnee
Splicing of fiber of 24/6F OFC in the joint enclouser/fiber termination box/FMS as per site requirement. inspection by consignee
Supply and installation of FMS (12 F) rack mountable single mode with splicing and termination of OFC cables with all accessories (Pig tail and other materials required for work to be supplied by contractor. Inspection by consignee
Supply, installation, testing and commissioning of 24 port b10/100/1000 Mbps smart- managed POE switch with 4 SFP ports as per RDSO/SPN/TC/83/2020 Rev. 2.0 or latest. inspection by RITES.
Supply of Smart Managed 8 Port POE switch supports 1Gbps or more speed with 2 SFP Uplink Ports. inspection by RITES.
Supply of Wireless Keyboard with Mouse. inspection by consignee.
Supply , installation and commissioning of SFP module 10/100/1000 mbps compitable with switch single mode 1310/1550 Fiber module single fibre with suitable patch cord. inspection by consignee.
Supply of Remote Fault Remote Diagnostic System with minimum specification -Intel i7 [up to 4.7 GHz]10 Cores and 12 MB Cache, Windows OS latest, MS office professional latest, RAM- 16 GB DDR4, Storage- 1TB SSD, Screen- 14inches. Inspection by RITES.
Supply of PVC Conduit Pipe of 25 mm dia ISI marked heavy (HMS)series as per IS: 9537part-III - 1983 standards or latest. inspection by consignee.
Laying & Fixing of conduit 25mm (conduit Pipe must be fixed with clamp at the interval of 300mm)/HDPE/GI/RCC Pipe. Inspection by site engineer.
Laying of OFC Cable/STP Cable/Power Cable in conduit pipe and PVC channel. inspection by consignee.
Supply of RJ-45 connectors with cap. inspection by consignee.
Supply of OFC jumper (patch chord)(10 mtr long) with FC/PC & SC or suitable connector at both end as per site requirement (as per IRS:TC/81-2000 with latest amendments.). inspection by consignee.
Supply UTP Cat-6 Patch cord 3 Ft. long. Inspection by consignee
Fusion Splicing machine fully automatic PTC Microprocessor controlled (ARC Fusion) 42 as Specification no. TEC/GR/TX/OSM-001/04/SEP-12 or latest with all accessories such cleaver, round cable cutter, fiber stripper, spare blade for cleaver and two nos of electrode for splicing machine etc. inspection by RITES.
Supply of OTDR Machine as per technical specification Tec/GR/TX/OTD-001/05/Sep-19 or latest. Inspection by RITES
Excavating & refilling of trench in normal soil to the level of ground with rammed earth asper Drg. NO.(NR/S&T/Con/1-1/97) so as not form a drain,0.3 Mts wide & 1 Mts deep on both 44 side of the station along the track. It shall confirm to the safe distance as per signalling & cable route plan in all type of soil, it also includes clearance of roots of trees & bushes. Lesser depth due to site condition shallbe paid proportionately, after being decided in writing by engineer not below the rank of JAG. Inspection by site engineer
Supply, installation, testing, wiring& commissioning of Copper(Ethernet) to Fiber Media Convertor as per clause no 16 of RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0or latest. inspection by RDSO
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .