Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.7 LAccepted-AOC 72 133 THOTTILPATTY SALEM CAMP METTUR DAM 636456 | METTUR DAM | SALEM | TAMIL NADU | 636456 | ₹4.7 L Quoted ₹4.5 L | 1 | Accepted-AOC L1 |
| 2 | 2₹4.7 LRejected-AOC H 29 COOLIE LINE METTUR DAM 636 401 | METTUR DAM | SALEM | TAMIL NADU | 636401 | ₹4.7 L | 2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | KSS Engineering Contractor L1 | MEGALA ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Providing necessary temporary scaffolding arrangements in the Boiler bottom area upto 7.5 Mtrs elevation in all the four sides of the boiler for dismantling, cleaning and rectification of defective / dislocated boiler seal trough seal plates and providing patch plate, and refixing of S.S woven wire mesh, dismantling the scaffolding arrangements after completion of work. | 260 | m2 | 135 ₹35,100 | 165 ₹42,900 |
| 2.00 | Dismantling cleaning and refixing of S.S woven wire mesh (old/new) inside boiler bottom seal trough area, dismantling the existing wire mesh and lowering to ground level. | 40 | m2 | 227 ₹9,080 | 252 ₹10,080 |
| 3.00 | Cleaning the dismantled mesh, removing the bend / distortion on the mesh, reconditioning the damaged bars and support plates, lifting the cleaned mesh to 7.5 mtrs elevation and refixing new/old S.S mesh with new S.S bolt, nut & washer. | 40 | m2 | 795 ₹31,800 | 920 ₹36,800 |
| 4.00 | Cutting, rectification and re-welding the existing seal plate in the bottom ash hopper area. (Patch plate will be provided by the TANGEDCO if required). | 10 | m2 | 9,432 ₹94,320 | 9,465 ₹94,650 |
| 5.00 | Charges for removal of worn out/ damaged insulation and Aluminium sheet from Boiler pipe lines | 50 | m2 | 333 ₹16,650 | 350 ₹17,500 |
| 6.00 | Charges for cutting of new / old ceramic blanket/wool mattress for required size and fixing on Boiler pipe lines | 50 | m2 | 437 ₹21,850 | 460 ₹23,000 |
| 7.00 | Charges for cutting new Aluminium / G.I sheet to required size, bending forming and making locking grooves and fixing / repairing, dents removal from released Aluminium/ G.I sheets, fixing on insulation and positioning the sheets intact with suitable fasteners on Boiler pipe lines | 50 | m2 | 525 ₹26,250 | 555 ₹27,750 |
| 8.00 | Light Resin Bonded wool Mattresses, Size 1.62 m X 1.22 m X 60mm thick confirming to IS 8183,93. Density: 150 Kg/m3, 0.75 inch X 23 SWG G.I wire knitting with machine stitched both sides and laid in HDPE | 50 | m2 | 677 ₹33,850 | 710 ₹35,500 |
| 9.00 | Skin casing fixing screws | 300 | Nos. | 6.2 ₹1,860 | 7 ₹2,100 |
| 10.00 | SS Wire Mesh 3230 x 500 x 16mm weaving square gap, Material:SS304 for boiler seal trough area | 8 | Nos. | 12,550 ₹1.0 L | 12,810 ₹1.0 L |
Tender Value
Refer Docs
EMD Value
₹4,400
Closing Date
26 Nov 2025, 2:00 pmClosed
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I BM Unit II Boiler pressure parts AOH 2025 Dismantling cleaning and rectification of defective seal trough seal plates SS woven wire mesh providing patch plate
2025_EB_622615_1
CE / MTPS-I / SE / M-I / BM /OT. 344 / 2025-26
Open Tender
Power/Energy Projects/Products
20 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹4,400
Yes
29 May 2026
12 Nov 2025
27 Nov 2025
12 Nov 2025
26 Nov 2025
12 Nov 2025
Amount
Providing necessary temporary scaffolding arrangements in the Boiler bottom area upto 7.5 Mtrs elevation in all the four sides of the boiler for dismantling, cleaning and rectification of defective / dislocated boiler seal trough seal plates and providing patch plate, and refixing of S.S woven wire mesh, dismantling the scaffolding arrangements after completion of work.
Dismantling cleaning and refixing of S.S woven wire mesh (old/new) inside boiler bottom seal trough area, dismantling the existing wire mesh and lowering to ground level.
Cleaning the dismantled mesh, removing the bend / distortion on the mesh, reconditioning the damaged bars and support plates, lifting the cleaned mesh to 7.5 mtrs elevation and refixing new/old S.S mesh with new S.S bolt, nut & washer.
Cutting, rectification and re-welding the existing seal plate in the bottom ash hopper area. (Patch plate will be provided by the TANGEDCO if required).
Charges for removal of worn out/ damaged insulation and Aluminium sheet from Boiler pipe lines
Charges for cutting of new / old ceramic blanket/wool mattress for required size and fixing on Boiler pipe lines
Charges for cutting new Aluminium / G.I sheet to required size, bending forming and making locking grooves and fixing / repairing, dents removal from released Aluminium/ G.I sheets, fixing on insulation and positioning the sheets intact with suitable fasteners on Boiler pipe lines
Light Resin Bonded wool Mattresses, Size 1.62 m X 1.22 m X 60mm thick confirming to IS 8183,93. Density: 150 Kg/m3, 0.75 inch X 23 SWG G.I wire knitting with machine stitched both sides and laid in HDPE
Skin casing fixing screws
SS Wire Mesh 3230 x 500 x 16mm weaving square gap, Material:SS304 for boiler seal trough area
SS Bolts & Nuts
T & Ps and consumables
MEGALA ENTERPRISES (BID ID -1518848)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
BOQ_744549.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid