AGE(I) Navy Chennai Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
AS AS TO CENTRALISED MONITORING STATION AND PROVISION OF DRY AND FRESH RATION STORE ROOM AT MEENAMBAKKAM UNDER AGE(I) NAVY CHENNAI
2021_MES_465144_1
AGE(I)/NAVY/CHN/8181 of 2021 - 22
Open Tender
Civil Works
Item Rate
120 days
Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹15,000
Yes
22 Sept 2021
4 Aug 2021
2 Sept 2021
4 Aug 2021
1 Sept 2021
18 Aug 2021
5 Aug 2021 - 11 Aug 2021
Amount
Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed by Engineer in Charge.
M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mmx600mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 8mm thick high Pressure Non Asbestos Fiber Cement decorative Board (E-Board Classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof eith adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be interlocked between main runners @ 610mm c/c, as to form 600 mm x 600 mm grid complete all as specified and as directed by Engineer in Charge.
Taking down shutters of any description exc 1 Sqm n exc 2 sqm each leaf complete all as specified and as directed by Engineer in Charge.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) of size not exceeding 1.50 Square metre each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts complete all as specified and as directed by Engineer in Charge.
All as per Sl item No. 4 above but size exceeding 1.5 Square metre and not exceeding 4 Square metre each complete all as specified and as directed by Engineer in Charge.
S&F 30mm thick flush shutter solid core construction with block board core and plywood face panels commercial type on both side complete all as specified and as directed by Engineer in Charge.
S&F 2nd class hard wood glazed and skeleton door shutters 30mm thick open rebated and prepared to receive glass, guage etc (without sash bars), edge of framing plain chamfered or rounded fitted with cut and mitred beds for securing glass etc size of members of shutters as specified in SSR Part I section 8 clasue 8.20(a) complete all as specified and as directed by Engineer in Charge.
S&F 2nd class hard wood glazed and skeleton Ventilator/window 30mm thick open rebated and prepared to receive glass, guage etc (without sash bars ), edge of framing plain chamfered or rounded fitted with cut and mitred beds for securing glass etc size of members size of members of shutter as specified in SSR Part I section 8 clasue 8.20(b) complete all as specified and as directed by Engineer in Charge.
Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified.
M&L plain cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate as in filling of steel chowkhats and holdfast including necessary form work complete all as specified and as directed by Engineer in Charge.
S&F Anodised aluminium powder coated any colour as approved for ventilator frame and shutter , half fixed and half louvered type without sash bar , incuding 4 mm thick glass , necessary joining cleats , glazing clips , rubber packing , anodised aluminium snap beading ,screws etc and section weighing 0.55 kg/ Rm complete all as specified and as directed by Engineer in Charge.
S&F Anodised aluminium powder coated any colour as approved window shutters, incl window frame with three track sliding type, without sash bars including guide rollers as reqd nos, including 4mm thick glass necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings as required like suitable handle, star lock etc and section weighing 0.55kg/Rm complete all as specified and as directed by Engineer in Charge. (Note- Rate incl for providing slide or fix type mosquito proofing shutter and addl track if reqd)
S&F Anodised aluminium powder coated any colour as approved Door shutters, incl frame with prelaminated board of 6 mm thick at bottom , without sash bars including guide rollers as reqd nos, including 4mm thick glass necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings as required like suitable handle, star lock etc and section weighing 0.55kg/Rm complete all as specified and as directed by Engineer in Charge. (Note- Rate incl for providing slide or fix type mosquito proofing shutter and addl track if reqd)
S&F MS butt hinges cold rolled medium weight 100mm long complete all as specified and as directed by Engineer in Charge.
S&F MS butt hinges cold rolled medium weight 75mm long complete all as specified and as directed by Engineer in Charge.
S&F Aluminium, anodised, barrel tower bolts of extruded section 200mm long complete all as specified and as directed by Engineer in Charge.
S&F Aluminium, anodised, barrel tower bolts of extruded section 150mm long complete all as specified and as directed by Engineer in Charge.
S&F Extruded aluminium alloy handles, fabricated type , anodised 125 mm in size complete all as specified and as directed by Engineer in Charge.
S&F Extruded aluminium alloy handles, fabricated type , anodised 75 mm in size complete all as specified and as directed by Engineer in Charge.
S&F in repairs MS sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12 mm dia and 300 mm long complete all as specified and as directed by Engineer in Charge..
S&F in repairs second class hard wood small fittings including 50 mm thick butt hinges such as brackete of any type , stopper/cleat for door or window, articles n.exc. 200 cu cm each with MS butt hinges cold rolled medium weight 50 mm long complete all as specified and as directed by Engineer in Charge.
M&L double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box , main body with stainless steel cover , governing pivot made of brass , other parts made of mild steel heavy duty and fixed complete all as specified and as directed by Engineer in Charge.
S&F in repair Aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.4mm and fixed with beading to wooden frames with aluminium wire staples complete all as specified and as directed by Engineer in Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises.
M&L Glazed ceramic tiles in vertical surface 300 X 450 X 7mm thick incuding rendering 10 mm thick cement mortar (1:4) to receive tiles in vertical surfaces all as specified set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed by Engineer in Charge.
M&L Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc including screed bed or bedding layers of 15 mm thick cement mortar (1:6) for laying floor finishes all as specified. all as specified set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer in Charge.
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting/dado etc incuding rendering 10 mm thick cement mortar (1:4) to receive tiles in vertical surfaces , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer in Charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed by Engineer in Charge.
M&L fly ash Brick work, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer in Charge.
M&L fly ash brick work straight or curved on plan to any radius in half brick wall in cement mortar 1:4 complete all as specified and as directed by Engineer in Charge.
M&L 10 mm thick CM plaster in CM(1:4) mixed with water proofing compound @3% by weight of cement over while the padding concrete is still green complete all as specified and as directed by Engineer in Charge.
Supply only liquid water proofing compound
M&L for rendering 15mm thick in cm 1:3 cement plaster on fair faces of brick or concrete surfaces finished even and smooth without using extra cement, with water proofing compound @3% by weight of cement complete all as specified and as directed by Engineer in Charge.
Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed by Engineer in Charge.
M&L 15mm thick rendering in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth without using extra complete all as specified and as directed by Engineer in Charge.
M&L Rendering/plastering, 10mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, using WPC, surfaces finished finished even and smooth without using extra complete all as specified and as directed by Engineer in Charge. (WPC measured separately).
M&L preparation of new undecorated plastered surface of walls and applying two coat of colour distemper oil emulsion over one coat of primer on wall complete all as specified and as directed by Engineer in Charge.
M&L for complete removal of existing treatment and applying two coat of oil bound distemper (white or tinted) over a coat of whiting on wall complete all as specified and as directed by Engineer in Charge.
M&L for complete removal of existing treatmentand applying two coats of exterior wheather coats (as per manufacturers instruction ) over a coat of wall putty complete all as specified and as directed by Engineer in Charge.
M&L 12mm thick Toughened Glass partition with hatching design/ pattern as approved and fitted to top and bottom rail to floor and ceiling hardwood chamfered or rounded fitted with cut and mitred beads for securing glass with necessary fitting arrangements and gaps are filled with silicon sealant complete all as specified and as directed by Engineer in Charge.
M&L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two coats complete all as specified and as directed by Engineer in Charge.
M&L for fabrication Kitchen base unit with 18mm Boiled Water Proof Plywood ISI marked termite free With Double side Laminate HD Gloss finished box, Drawers with shutters and car case inclusive of all necessary hard ware and fittings complete all as specified and as directed by Engineer in Charge.
M&L for fabrication Kitchen wall unit with 18mm Commercial plywood ISI marked termite free With Double side Laminate HD Gloss With Double side Laminate finished box with shutters and car case inclusive of all necessary hard ware and fittings complete all as specified and as directed by Engineer in Charge.
M&L for fabrication kitchen tall unit with 18mm Commercial plywood ISI marked termite free With Double side Laminate HD Gloss With Double side Laminate finished box with glass shutters and car case inclusive of all necessary hard ware and fittings complete all as specified and as directed by Engineer in Charge.
M&L for fabrication ration unit With 18mm Commercial plywood ISI marked termite free with Double side Laminate HD Gloss With Double side Laminate finished box with shutters 4mm thicck glass shutteres and car case inclusive of all necessary hard ware and fittings complete all as specified and as directed by Engineer in Charge.
S&F of 101X508X609mm CUTLERY basket of SS 304 Quality as specified and directed by Engineer in charge
S&F of 101x508X609mm PLAIN BASKET SS 304 Quality as specified and directed by Engineer in charge.
M&L brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick wall in cement mortar 1:4 complete all as specified and as directed by Engineer in Charge.
M&L Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer in Charge.
S&F Non Skid ceramic tiles colour 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry with 3.00 Kg of cement per sqm complete all as specified and as directed by Engineer in Charge.
S & F 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed by Engineer in Charge.
Aluminium handles, cast type, anodised 125mm long fixed with screws complete all as specified and as directed by Engineer in Charge.
M&L Rendering/plastering, 10mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, surfaces finished finished even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge.
M&L 18 mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, cocking platforms and like including pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and 15 mm thick screed bed or bedding layers in cement mortar 1:4 over brushing with neat cement slurry with 3.00 Kg of cement per sqm complete all as specified and as directed by Engineer in Charge.
M&L for Point wiring for one light point controlled by one switch with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core FRLS drawn with stove enamelled steel conduit of 20 mm dia,or as per IS, concealed FRLS wiring, along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof excluding Modular Metal flsh box and white cover plate with frame the switches, sockets, fan regulator etc as required suitable for Modular type fitting /fixture all as specified and directed by Engineer in Charge.
All as per Sl item no. 57 above but for one fan /Exhaust fan point controlled by one regulator / switch.
All as per Sl item no. 57 above but for one 3 pin socket outlet 5 amps socket on same board
All as per Sl item no. 57 above but for one 3 pin socket outlet 5 amps socket on independent board
All as per Sl item no. 57 above but with 2.5 sqmm cable for one 3 pin socket outlet 15 amps on independent board with 2.5 sqmm cable as earthing conductor
S & F for Modular Switch, 1 Way, 6A, 1 Module
S & F for Modular Switch, 1 Way, 16A, 1 Module
S & F Modular Socket, 6A, 2/3 pin combined, 2 Module
S & F Modular Socket, 6A / 16A, 2/3 pin combined, 2 Module
S & F for Modular White cover plate with frame, 3 Module
S & F for Modular White cover plate with frame, 6 Module
S & F for Modular White cover plate with frame, 12 Module
S & F for Modular Metal flush box, 3 module
S & F for Modular Metal flush box, 6 module
S & F for Modular Metal flush box, 12 module
M&L for ceiling rose, 3 phase fire rated polycarbonate, isolated body all as specified and directed by Engineer in Charge
S&F for sub main Wiring for Circuit of size 2 x 4 sq.mm along with earth wire of size 1 x 4 sq.mm, Single Core, PVC insulated copper coductor (FRLS) Cable in surface / recessed PVC Conduit including tacking down old complete all as specified and directed by Engineer in Charge
S&F 2X2 LED fitting 36 Watt ,3600 lm ,6500 K suitable for LED Recessed full lit luminaire with glare free uniform illumination with longer life and less maintenance complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and lamp complete all as specified and directed internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and directed . Make : Crompton LCTLRNE-36-FO-CDL, or equivalent in Philips, Wipro as approved AGE(I)
S&F 400 mm 3 Blade Wall Fan complete with all accessories internally pre-wired and including connecting up with twin core flexible copper conductor cable with suitable size..
S&F air cooled split unit air conditioner electric driven single phase of capacity of 1.5 TR.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA
S&F of Power unit for up to 2 ton A.C complete all as specified and directed
S&F stepped type electronic fan regulator Modular type all as specified and directed by engineer in charge
S & F for sub main Wiring for Circuit of size 2 x 6.0 sq.mm along with earth wire of size 1 x 6 sq.mm, Single Core, PVC insulated copper coductor (FRLS) Cable in concealed / surface / recessed PVC Conduit
S&F sheet metal enclosure powder coated single door outdoor type for Distribution Board, SPN 8 way DB with Degree of Protection IP 54 , Detachable Gland Plate, Box Insertion Marks, Circuit Identification Label, Neutral Link, Earth Link, Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
S&F MCB SPN 32- 63 A , B curve including , Disconnecting electric connections, complete all as specified and as directed.
S&F MCB SP 06 A to 32 A , B curve including ,complete all as specified and as directed.
S&F 2X2 LED fitting 24 Watt ,3600 lm ,6500 K suitable for LED Recessed full lit luminaire with glare free uniform illumination with longer life and less maintenance complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and lamp complete all as specified and directed internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. complete all as specified and directed . Make : Crompton LCTLRNE-24-FO-CDL, Philips, Wipro
S&F Ceiling fan sweep 1200 mm BLDC motor with remote 3 blade, BEE rating 5 star, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
S&F exhaust fan 300 mm 4 Blade, Metal body, rust proof body and blades, double ball bearing with noiseless operation, 1400 RPM complete with louvers including making suitable opening at suitable height, and provision of nuts and bolts on the wall for fixing the exhaust fan complete all as specified and as directed
S&F Deep freezer hard top more than 320litre and upto 400 litre capacity having double door complete all as specified and as directed
M & L for New earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI wire 4mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 20mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : GI strip and protection pipes 20 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately.
Supply & fixing for GI wire 4 mm on wall/batten or recessed or buried in ground all as directed
kvs constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .