Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC TIORKHALI MAHESHGANJ NADIA | NADIA | NADIA | WEST BENGAL | 790804 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹45.9 L+₹58,525 (1.29%)Rejected-Finance PO CHANDL PS BISHNUPUR DIST SOUTH 24 PGS PIN 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹46.7 L+₹1.4 L (3.12%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹47.0 L+₹1.6 L (3.62%)Rejected-Finance ROOM NO B 111 PART III GANESH MURTINAGAR CAPT PRAKASH PETHE MARG CUFFEPRADE CALABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹48.1 L+₹2.8 L (6.14%)Rejected-Finance BHANGARMATH THAKURANICHAWK PO SAMABAYPALLY BALLY HOWRAH 711205 | HOWRAH | HOWRAH | WEST BENGAL | 711205 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
26 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
ADDN/ ALTN TO KITCHEN OF BLDG NO O-9 AND SHED OF BLDG NO O-5, SHED OF BACK SIDE OF BLDG NO O-1(L) AND O-1(R) AT INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2024_MES_640780_1
8218/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹90,000
Yes
21 Mar 2024
5 Feb 2024
27 Feb 2024
5 Feb 2024
26 Feb 2024
19 Feb 2024
Amount
Excavating in post holes soft /loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm.
M & L PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed.
S&F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of Fe-410-W(Gde-E-250) quality-A complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridges , valley gutter, Sun shed etc fixed with self tapping screws as specified.
M & L applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of surfaces complete.
M & L for heavy duty coloured ceramic floor tiles of size 300 x 300x 10 mm thick, suitable for high traffic external tiles, anti skid, scratch resistance and neutral to UV rays and acid alkali resistance as in floor including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M & L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth using without extra cement complete all as specified and directed.
M&L brick work with Fly ash bricks' old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed.
M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished rendering surfaces even and smooth (without using extra cement) complete all as specified and directed.
M & L two coats of cement based paint on newly plastered surface of wall including preparation and one coat of chalk white of surfaces complete all as specified and directed.
S & F powder coating of any colour (Thickness or powder coating not less than 50 micron). Anodised aluminium window three track and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F Aluminium door frame and operable shutter, windows and partitions and ventilators with one or more rebates including jointing cleat for fixing etc , complete all as specified and as directed.
S & F powder coating of any colour (Thickness or powder coating not less than 50 micron). Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified.
S & F 5.5 mm thick plain sheet glass ordinary quality and glazing with oil putty or wooden beads in square area exc. 0.5 Sqm in each pane complete all as specified and directed.
S&F in repairs 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap as in roof, wall fixed with coach screw and washer in roof, or cranked hook bolts complete all as directed by the Engr-in-Charge
S & F 5.0 mm thick Toughned glass good quality as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes as required complete all as specified and directed.
S&F in stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples as directed by Engr-in-Charge.
Demolition of Reinforcement Cement Concrete(reinforcement cut as required to facilitate demolition) Roof, floors (other than ground floors), beams, staircase, landing, chajjas and similar suspended work complete all as specified and directed.
M & L RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall, beam and columns in floor, roof landing,, balconies, conopies, deck slab and shelves etc complete all as specified and directed.
Use and waste of formwork to sides and soffits of suspended slabs, floor slab, landing and similar work n. exc. 200 mm thick rough finished surfaces of concrete complete all as specified and directed.
S & F mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
Supply and fixing 2nd class hard wood plain solid straight chowkats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified and as directed by Engineer-in-charge.
S &F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F stainless steel butt hinges 100mm medium weight all as directed.
S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as directed complete all as directed.
M&L False ceiling with 'E' board "Classic" , reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium powder coated snap grid to support the boards/files with aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides including hanging arrangements with 1.6mm dia GI wire and anodised adjuster and applying two coats of oil bound distemper over a coat of alkali resistant primer on exposed surfaces complete as in repair, all as specified and as directed
M&L non skid ceramic colour tiles of area of each tile exc .18 Sqm but n exc exc .38 Sqm and 8-10 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement complete including 15 mm thick screed bed cement mortar 1:6 complete all as specified and directed. all as specified and directed.
M & L glazed ceramic colour tiles size 450 mm x 300 mm x 6 to 7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement including 10 mm thick plastering in cement mortar 1:4 complete all as specified and directed. to match complete all as specified and directed.
M & L glazed ceramic colour tiles size 600 mm x 300 mm x 6 to 7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement including 10 mm thick plastering in cement mortar 1:4 complete all as specified and directed. to match complete all as specified and directed.
M & L for 20 mm thick screed bed or bedding layer of mortar as in backing coat of stone on fair face of brick wall or concrete surface in cement mortar 1:4 complete all as specified and directed.
M & L 18 to 20 mm thick machine cut one side polished natural hard stone (Granite)any type in step, jambs, pillars, window cills, cooking plate from and similar places etc like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L Vitrified ceramic joint free colour tiles area of each tile exc 0.18 Sqm but n exc exc 0 .36 Sqm and 7 to 8 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement complete including 15 mm thick screed bed cement mortar 1:6 complete all as specified and directed. all as specified and directed .
M&L Vitrified ceramic joint free colour tiles for Vertical surface of area of each tile exc 0.18 Sqm but n exc exc 0 .36 Sqm and 7 to 8 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement complete including 10 mm thick screed bed cement mortar 1:3 complete all as specified and directed. all as specified and directed .
S&F 18-19 mm thick Plywood, grade BWR,type BB, fixed with screws to timber frame for wardrobe/shelf all as specified and directed
M&L Decorative laminate type -1, 0.9 mm thickness of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's as per specification and drawing.
S&F Stainless steel powder coated tray of various size for drawers to keep kitchen utensil with smoothly sliding arrangement complete all as specified
S&F in repairs 4 levers brass body, lock ,drawer graded 1 size 50 mm, complete all as directed by the Engineer-in-Charge.
S&F in repairs aluminium 'E' channel for sliding drawer shutter of cub board in two way 300 mm long complete all as directed by the Engineer-in-Charge.
S&F 100 mm double action spring hinges (Hydraulic hinges) brass with phosphors bronze wire spring bright polished all as specified
S&F 100 mm Extruded brass handles, fabricated type polished all as specified
Supply and Fixing PVC solid wall lining consisting of 5 mm thick plain colour PVC sheet used inclusive of solvent cement and fixing at site on PVC frame as per manufacturer’s specification and instruction) directed .
Supply and Fixing PVC fillets of width 35 mm, made of 5 mm thick PVC sheet, for wall panelling inclusive of fixing as in grid / frame on wall at a distance .6m horizontal & vertical for wall lining/panelling as per specification of manufacturer and as directed.
M& L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed. all as specified and directed.
M&L for brushing neat cement slurry with 3.0 kg of cement per sq metre complete all as specified and directed. all as specified and directed.
M&L non skid endure joint free colour stepping tiles area of each tile exc 0.18 Sqm but n exc exc 0 .36 Sqm and 15 mm thick, Stair tread steps tiles etc, set and jointed in neat cement slurry and pointed in coloured cement complete including 15 mm thick screed bed cement mortar 1:6 complete all as specified and directed. all as specified and directed.
M&L non skid endure joint free colour stepping tiles for Vertical surface of area of each tile exc 0.18 Sqm but n exc exc 0 .36 Sqm and 15 mm thick, in Stair riser etc, set and jointed in neat cement slurry and pointed in coloured cement complete including 10 mm thick rendering cement mortar 1:3 complete all as specified and directed. all as specified and directed.
S&F Stainless Steel Sink l.0mm thick Overall size 915mm x 460mm and Two Bowl size 410 mm x 355 mm x 165 mm for Kitchen or Laboratory with Plugs, Washers, Brass chromium plated Waste Fitting 32mm dia, PVC waste pipe, a Pair of Cast Iron Brackets duly Painted including Cutting and Pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including Taking down/out unserviceable Sink and connected Items, complete all as specified and as directed.
S&F PVC Lipping edge tape decorative type 20-25 mm width and 0.5-1.0 mm thick all as specified and directed
M&L preparation of surfaces and pasting of wall paper of any design/ pattern/ shade, complete all as specified
M & L 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth using without extra cement complete all as specified and directed.
S&F 1st class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for ecuring glass,etc.; sizes of me-mbers of shutters as specified in SSR Part, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F 100 mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed all as specified.
S & F 10 to 12 mm thick gypsum board false ceiling including 0.55 mm thick GI perimeter channel, GI channel tray frame work having one flange of 20mm and another flange of 30mm with web of 27mm, fixed to surrounding wall using nylon sleeves and screws @ 450mm centre to centre / GI intermediate channel of size 45mm x 0.90mm thick with two flange of 15mm each suspended from the soffit of roof slab/ truss @1220mm c/c with MS angle of suitable size fixed to soffit of ceiling with GI cleat and expansion fasteners with and including ceiling section ( not exc 1.2 metre length ) of 0.55 mm thickness having kurled web of 50 mm and flange of 25 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel @ 457 mm centre to centre with necessary nuts and bolts and gypsum board screwed to ceiling section with stainless steel screws @ 230mm c/c including applying two coats of plastic emulsion paint over a coat of primer to exposed surfaces complete all as specified and directed.
S& F 12 mm thick seamless waterproof and termite proof WPC Louvers wall panelling fixed with probond adhesive and screwed to the wall complete all as specified and directed.
SCHEDULE 'A' PART-II (INTERNAL ELECTRIFICATION WORKS Taking down carefully existing aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete and making good the disturbed surfaces of walls, Floors, ceilings etc to match with existing all as specified and directed.
M & L for concealed type point wiring with 1.50 sqmm (nominal area) FRLSH insulated and unsheathed muld stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/celling including muld steel terminal boxes 1.25 mm thick conforming to IS - 5133(Part -I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked ) for mounting switches/ regulator / bell push etc including 1.50 Sqmm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point / bell point/ ceiling fan / exhaust fan point controlled by one way switch complete all as specified and directed. (a) One light/fan point controlled by one switch
All as per item No 61 but One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per item No 61 but One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
Description all as per item No 61 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, flame retardant Low Smoke ( FRLSH ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 1.5 sqmm green copper conductor as continuous earth wire with lugs complete all as specified and directed.
S & F Modular Switch 1 way 6 A, 1 module complete all as specified and directed.
S & F Modular Switch 1 way 16 A, 1 module complete all as specified and directed.
S & F Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular Blank plate, 1 module complete all as specified and directed.
S & F Modular type White cover plate with frame 3 module complete all as specified and directed.
S & F Modular type White cover plate with frame 4 module complete all as specified and directed.
S & F Modular type White cover plate with frame 6 module complete all as specified and directed.
S & F Modular type White cover plate with frame 8 module complete all as specified and directed.
S & F Modular type White cover plate with frame 12 module complete all as specified and directed.
S & F Modular type Metal Flush box 3 module complete all as specified and directed.
S & F Modular type Metal Flush box 4 module complete all as specified and directed.
S & F Modular type Metal Flush box 6 module complete all as specified and directed.
S & F Modular type Metal Flush box 8 module complete all as specified and directed.
S & F Modular type Metal Flush box 12 module complete all as specified and directed.
S&F Ceiling rose three terminals polycarbonate , isolated body complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V,warm light AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F in repair LED tube light fitting 10 watt, warm light mounted on wall / ceiling connected with insulated unsheathed flexible copper wire of suitable size (length not exceeding 0.5 m) from ceiling rose complete all as specified and directed.
Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M & L for sub main wiring with 4 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-capping of suitable size, surface type all as directed.
All as per Srl. Item No 84 above but with 2 run of 6.0 Sqmm cable and 6.0 Sqmm as earth continuity conductor complete all as specified and directed.
All as per Srl. Item No 84 above but with 2 run of 4.0 Sqmm cable and 4.0 Sqmm as earth continuity conductor complete all as specified and directed.
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through & including PVC conduit of suitable size in Surface/concealed all as directed.
Taking down of Old MCB DB any type any size including MCBs etc complete all as specified and directed.
S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with 200 amps rated bus bar complete all as specified and directed.
S & F TP&N Vertical Load line DBs are fitted with Bus Bars, Neutral Links, Blanking Plates 4 way double door DB LL 4W DD VERT W/O MCCB complete all as specified and directed.
S & F MCCBs 415V, 16KA, 4 Pole 100 Amps complete all as specified and directed.
S & F MCB 'C' series single pole 5 to 32 Amps, breaking capacity 10KA. complete all as specified and directed.
S & F in repair MCB 'C' series single pole and Neural 32 -63 Amps, breaking capacity 10KA,complete all as specified and directed.
S & F ceiling fans complete with all accessories 230 volt single phase 1200mm sweep with down rod any size , canopy, fan blades and accessories, BEE 5 Star Rated and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm , 3 core, 1100 Volts grade, from ceiling rose / connector to fan complete all as specified and directed.
S & F exhaust fan 250 mm sweep, AC single Phase 230 / 240 volts, metal body with louver shutters and connecting up with and including twin core twisted flexible copper conductor cable of suitable dia ,nut bolt and accessories, and winding,pending etc connecting up including taking down with re -fixing provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 sqmm , 3 core, 1100 Volts grade, from ceiling rose / connector to fan complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4.0mm GI wire (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 5 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering all as specified and directed and tested on completion.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
UNITED ENGINEERS
UNIVERSAL TRADING CENTRE
M/S SRINIVASA CONSTRUCTION
DUTTA & DUTTA
MAZUMDER ENTERPRISE
DEB AND COMPANY
DGR CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .