Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.4 L+₹4.7 L (17.5%)Rejected-Finance 1 GANESH DARSHAN ADV SURVE MARG SANDHURST ROAD W MUMBAI 9 | MUMBAI | MAHARASHTRA | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹33.2 L+₹6.5 L (24.2%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹48.7 L+₹22.0 L (82.4%)Rejected-Finance SHOP NO 12 KHOPKAR APARTMENT KUMBHARAWADA URAN DISTT RAIGAD 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L4 | Rejected-Finance BEING L4 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Apr 2022, 6:00 pmClosed
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIRS/ MAINTENANCE OF SPLIT/WINDOW ACS, REFRIGERATOR, DEEP FREEZERS, WATER COOLERS AT VARIOUS LOCATIONS INCLUDING INSIDE OLD AIRPORT AT AFS MUMBAI AND AFS MADH ISLAND UNDER GE (AF) THANE
2022_MES_515493_1
8179/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹70,000
Yes
24 May 2022
28 Mar 2022
26 Apr 2022
28 Mar 2022
25 Apr 2022
13 Apr 2022
28 Mar 2022 - 13 Apr 2022
Amount
M&L for periodical Servicing of Air conditioner Split type of capcities 1.0 to 2.0 TR complete with dismantling internal and external units into components , cleaning of components fan motor, blower, housing, filters etc.Checking up and rectification to wiring and connections,cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, reallignment of the fan coil unit and replacement of drain / condensate pipe , connecting up and testing, to make the unit in fully working condition complete all as specified and directed by Engineer-in-Charge. Note:1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labour Charge for on site repairs is deemed to be included in the quoted rate of the job
All as per Item No.1.00 here in before but for Airconditioner window type of capacity 1.0 to 2 TR
Supply and fix the following spares incorporated during the repairs to Air conditioner Split / Window type vide Sl Item No. 1 here- in- before but Supply and fix only Capacitor for AC 1.0 TR - 2.0 TR
Supply and fix in repairs only Capacitor for Condensing Fan Motor
Supply and fix in repairs only Starting Relay
Supply and fix in repairs only Evaporator Fan / Blower for for Window AC
Supply and fix in repairs only Printed Circuit board for split AC as per sample
Supply and fix in repairs only Filter Drier
Supply and fix in repairs only Condenser Fan Motor for split AC 1.0 TR
Supply and fix in repairs only Condenser Fan Motor for split AC 1.5 TR
Supply and fix in repairs only Condenser Fan Motor for split AC 2 .0 TR
Supply and fix in repairs only Compressor Sealed Unit for AC of capacity 2.0 TR
Supply and fix in repairs only Compressor Sealed Unit for AC of capacity 1.5 TR
Supply and fix in repairs only Compressor Sealed Unit for AC of capacity 1.0 TR
Supply and fix in repairs only Condensor Unit for air conditioner
Supply and fix in repairs only Blower motor for Split type AC as per sample
Supply and fix in repairs only Condenser Fan Motor for Window AC As per Sample
Supply and fix in repairs only Thermostat Switch
Supply and fix in repairs only Swing motor for Split AC
Supply and fix in repairs only Evaporator Fan / Blower for for Split AC
Supply and fix in repairs only Cooling Coil
Supply and fix in repairs only Over Load Protection Coil
Supply and fix in repairs only Copper Capillary tube of Air Conditioner
Supply & fix in repair including taking down old one out door unit cabinets with out compressor for split type AC of capacity for AC 1.0 TR
Supply & fix in repair including taking down old one out door unit cabinets with out compressor for split type AC of capacity for AC 1.5 TR
Supply & fix in repair including taking down old one out door unit cabinets with out compressor for split type AC of capacity for AC 2.0 TR
Supply & fix in repair including taking down old one in door unit for split type AC of capacity for AC 1.0 TR
Supply & fix in repair including taking down old one in door unit for split type AC of capacity for AC 1.5 TR
Supply & fix in repair including taking down old one in door unit for split type AC of capacity for AC 2.0 TR
M&L for periodical repairs and maintenance of water cooler of cooling capacity upto40 /60 Ltrs / Hr and storage capacity upto 80 /120 Ltrs complete with disconnecting the water connection, inserting dead plug, dismantling the fan motor, taps, fan blades, condenser etc.Checking up and rectification to wiring and connections, replacement of necessary parts and accessories, cleaning of the cold water tank, piping, refrigerant lines, reallignment of the fan coil unit and replacement of drain pipe , connecting to water mains and testing to make the unit in fully functional condition. Note: 1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labor Charge for On site repairs is deemed to be included in the quoted rate of the job.
Supply and fix in repairs only the spares incorporated during the repairs to Water Cooler vide Sl Item No.30 herein before.-Thermostatswitch with knob
Supply and fix in repairs only Push tap inner / outer thread chromimum plated of size 1/2 ".
Supply and fix in repairs only Rubber gasket with PVC sheet for Top Lid
Supply and fix in repairs only Condenser fan motor for water cooler.
Supply and fix in repairs only Capacitor for water cooler
Supply and fix in repairs only Starting Relay as per Sample
Supply and fix in repairs only PVC Hose Pipe size 3/4 " to 1 "
Supply and fix in repairs only Waste water tray as per sample
Supply and fix in repairs only Compressor Sealed unit for water cooler of capacity upto 120Ltrs
Supply and fix in repairs only Condenser unit for water cooler
Supply and fix in repairs only Overload protection for Water cooler
Supply and fix in repairs only Capillary tube of water cooler
S & Fix in repairs ball brass valves, high pressure with Polyethylene float and flynut complete screwed for Iron pipe on or brass ferrule and fixed of size 15 mm dia
Supply and fixing in repairs Sheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 32 Amps 240 Volts
S&F in repairs stop gun metal gate or globe valves with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15 mm dia.
Taking down geyser of capacity 25 to 50 Ltrs from the location after disconnecting electric and water connection carefully and sealing cable ends and water pipe for repair or removing to store for safe custody & stripping down, testing of tank, and connecting up carrying out repairs complete all as directed by EIC at site. Note: 1. Equipment Shall be serviced once in a Month and no repeat maintenance shall be measured. 2. Spare replaced during the process of repair shall be measured and paid separately as a supply only under relevant item here-in after.
Supply and install including taking down old one water heater storage type of capacity 25 liters glass lined coated inner tank, suitable for high pressure and pressure pump installation 02 KW heating elements fire retardant cable with 3 pin plug etc complete all as specified and as directed by EIC. Make: Havells/ Bajaj
Supply and install including taking down old one water heater storage type of capacity 15 liters glass lined coated inner tank, suitable for high pressure and pressure pump installatrion 02 KW heating elements fire retardant cable with 3 pin plug etc complete all as specified and as directed by EIC. Make: Havells/ Bajaj
Supply and fix only the spares incorporated during the repair to geysers vide Sl Item no 46 herein before for Heating Coil 2 KW
Supply and fix in repairs only Heating Coil 1.5 KW
Supply and fix in repairs onlyThermostat
Supply and fix in repairs only Copper Water tank for Geyser of capacity upto 25 Ltrs
Supply and fix in repairs only Non return valve Brass Chromium plated 15 mm / 20 mm
Supply and fix in repairs only Safety valve with anti vacuum pressure reducing HPRV
Supply and fixing of PVC Cable entry tray of size 100 MM X 75 MM fopr entry of copper capillary tube and PVC hose pipe of water . Make Legrand or equivalent
M & L for refrigent charging /Top up to Air conditioners/water coolers complete all as directed and specified by Engr-in- Charge
Supply and fixing in repairs of insulation over and around copper tubing to be fitted across the whole length of copper tubing incl all fixing arrangements and checking for insulation leakages if any
M&L for periodical Servicing of Deep Freezer and Refrigerator of any capacities complete with dismantling internal and external units into components , cleaning of components fan motor, blower, housing, filters etc.Checking up and rectification to wiring and connections,cleaning and reinsulation of refrigerant lines, replacement of necessary parts and accessories, reallignment of the fan coil unit and replacement of drain / condensate pipe , connecting up and testing, to make the unit in fully working condition complete all as specified and directed by Engineer-in-Charge. Note:1. Equipment Shall be serviced once in six months and no repeat maintenance shall be measured. Labour Charge for on site repairs is deemed to be included in the quoted rate of the job
Speedfrost Services Pvt Ltd.
NANGIA AND CO
ENJOY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .