| 1 | L1₹1.5 CrAccepted-AOC AWANTA BHAWAN SOURA SRINAGAR 190011 J K | SRINAGAR | JAMMU AND KASHMIR | 190011 | ₹1.5 Cr | L1 | Accepted-AOC Lowest One |
| 2 | L2₹1.7 Cr+₹17.5 L (11.7%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.7 Cr+₹17.5 L (11.7%) | L2 | Rejected-Finance OTHER THAN LOWEST ONE |
| 3 | L3₹1.7 Cr+₹19.7 L (13.1%)Rejected-Finance 01 KHUMRIYAL KUPWARA KHUMRIYAL KUPWARA KUPWARA JAMMU KASHMIR 193223 | KUPWARA | JAMMU AND KASHMIR | 193223 | ₹1.7 Cr+₹19.7 L (13.1%) | L3 | Rejected-Finance OTHER THAN LOWEST ONE |
| 4 | L4₹1.7 Cr+₹21.2 L (14.2%)Rejected-Finance | ₹1.7 Cr+₹21.2 L (14.2%) | L4 | Rejected-Finance OTHER THAN LOWEST ONE |
| 5 | L5₹1.7 Cr+₹23.9 L (15.9%)Rejected-Finance | ₹1.7 Cr+₹23.9 L (15.9%) | L5 | Rejected-Finance OTHER THAN LOWEST ONE |
Tender Value
₹1.9 Cr
EMD Value
₹2.7 L
Closing Date
30 Mar 2024, 6:00 pmClosed
CE 31 Srinagar Zone
HQ CE 31 Zone Srinagar Sonwar Srinagar 19004
AUGMENTATION OF ELECTRIC INFRA AND ALLIED WORKS PHASE-II UNDER GE 970 EWS
2024_MES_640397_1
800155
Open Tender
Electrical and Maintenance Works
Item Rate
900 days
Old Air Field
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
GE 970 EWS
₹2.7 L
Yes
HQ CE 31 Zone Srinagar
2 Jul 2024
5 Feb 2024
1 Apr 2024
5 Feb 2024
30 Mar 2024
25 Feb 2024
5 Feb 2024 - 21 Feb 2024
12 Feb 2024
Amount
(K) ACCESSORES: 150mm Dia Dial type thermometer with Alarm and trip contacts 150mm Dia Dial type thermometer with Alarm and trip contacts Buchholz Relay (Double float) 150mm Dia Winding Temperature indicator 4Nos Wheels Plain / Flanged / Bi-directional / Uni-directional Explosion Vent diaphragm Silicagel Breather Valves. (L) TERMINATION ARRANGEMENT: H.V. SIDE (CABLE BOX) Auxiliary L.V. (Cable box) Disconnecting Chambers for HT Conservator with oil filling hole with cap & drain plug with extension of pipe. Detachable radiator with shut off valve Oil level gauge with 3 position Filter valve 25mm size Air release valve Rating & terminal marking plate Weather proof Marshaling box with connection for above auxiliary protection with Lamp holder with Switch. (M) Miscellaneous: Test Required : Routine Test, All routine test as per IS : 2026, Oil Pressure & Vacuum with stand test : 7 PSI Colour shade : D.A.Gary (N) GENERAL ARRANGEMENT: The unit consists of following:- (a) Stepdown Transformer- Double wound Delta/Star connected. (b) ‘ON’ Load Voltage Regulator, Auto wound Delta connected. (c) Buck-Boost Transformer, Double wound, open/open connected (d) Automatic control gear consisting of :- One Electronic Voltage Relay, One Reversing Step Syn type geared motor unit, Two limit switches in order to avoid over running highest and lowest positions, chain drive, coupling device and all electrical connection. (O) CONSTRUCTION: The Items (a) & (c) will be housed inside a well ventilated sheet steel tank and mounted on feet and items shall be supplied with first filing of oil, fittings would include:- (i) Rating & Diagram Plate (ii) Silica gel breather (iii) Earthing Terminals (iv) Lifting lugs (v) Drain valve (vi) Air Release plug (vii) Oil Conservator with Oil level indicator (viii) Filter valve (ix) Pressure Relief Valve (x) W.T.I. & O.T.I. (xi) Buchholz Relay
(P) GENERAL FEATURES: (I) HAND CONTROL: Hand wheel will be located on the front of the Regulator tank at convenient operative height. (II) MOTOR CONTROL: Raise / Lower push button control by means of small single phase reversible geared motor of permanent capacitor type will be provided. Limit switches will be fitted to restrict the travel at extreme positions. With this arrangement, it would also be possible to provide remote control to the Regulating Unit. The reversible geared motor would be of ‘Step-Syn’ type - E10 (III) AUTOMATIC CONTROL: For automatic correction of fluctuating supply voltage, we shall provide Electronic Relay which in its simplest form, senses the Output Voltage and provide signal to the driving motor for necessary correction complete all as specified and directed.
Supply and installation/interconnection of VCB panel SF6 with complete busbar arrangements & SITC of new OEM 11 KV VCB Panel Board consisting of 1 Incoming/outgoing indoor type, 630 Amps, 25 KA for 3 Sec, The panel shall be fully type tested. The incoming feeder compartments shall have drawn out type PT and the VCB compartments shall have metering and protection CTs as required. The switchgear shall be designed for a symmetrical breaking capacity of not less than 25kA confirming to IS / IEC 62271 -100, 62271-102 with latest amendments including breaker including the cost of all required accessories, handling, transportation, CTs, draw out type PTs with rolling floor design for ease of maintenance & numerical relays for over current, earth fault, current & voltage displays, alarm and annunciation, indications, meters, LT control & instrumentation cables of required specifications etc complete in all respect for proper completion of work. Vacuum Circuit Breakers must be manufactured by ISO 9000 certified manufacturer and shall have been type tested at CPRI/ NABL accredited Laboratory or any Govt. approval laboratory within 10 years as on the date of bid opening and in satisfactory operation for a period not less than three years. The copies of Type Test reports shall be provided at the time of supply to Engineer in charge. The VCB must have the following: (a) 630 Amps continuous bus bar, the material shall be of high conductivity electrolytic copper only. All bus bars shall be heat-shrinkable PVC sleeves and joints shall be covered by HT sleeve as per 15, including color coding for phase indication -01 Job. (b) Circuit breaker shall be mounted on a withdrawal truck which shall roll out horizontal from service position to isolated position with and including suitable size (as per manufacturer's recommendation) AC Powerpack and suitable to operate entire control system and having sufficient power back up to operate TRIP / CLOSING operation at least 5 times including inbuilt charging system 24 volts DC-01 Job. (c) Motorised spring charging mechanism 230 volts AC-01 Job. (d) Cast resin current transformer suitable to 11 kV, indoor VCB, 11KV, 100-50A/5+5A, 7.5VA burden, accuracy class 5P10 for protection and class-1.0 for a metering-01 Job.
(xii) Conductor cable as per manufacturer's instructions as required at site-01 Job. (xiii) The contractor shall submit a type test certificate to the Engr-in-charge / GE for approval before placing the order. Conditions:- The switchboards shall be designed to operate under site conditions as specified in the datasheets. If not specifically mentioned therein, a design ambient temperature range upto (+)40°C and an altitude not exceeding 1000-2000 meters above mean sea level shall be considered. (i) All openings, covers, and doors shall be provided with suitable gaskets around the perimeter to make the switchboard dust and vermin proof. (ii) Each unit of the switchgear shall have necessary internal sheet metal barriers to form separate compartments for circuit breakers, busbars, instruments and relays, cable connections, etc. Compartments for cable connections shall allow cable termination and connection work with the switchgear energized. A suitable interlock shall be provided such that the cable compartment can be opened only when the earth switch is ON or Earthing truck is inserted. (iii) It shall be possible to extend the switchgear in either direction at a later date. Ends of bus bars shall be suitably drilled for this purpose. Panels at extreme ends shall have openings, which shall be covered with plates screwed to the panel. Details of drilled holes in bus bar and openings in the panels, provided for future extension shall be clearly shown in the vendor drawings. (iv) All joints and connections of the panel members shall be made by zinc-passivated high-quality Grade 8.8 or superior steel bolts, nuts and washers, secured against loosening. (v) Suitable eyebolts/ lifting clamps shall be provided for the lifting of the panel/shipping section. (vi) A rear door interlock shall be provided i.e rear door can not be opened unless the breaker is in the test position.
Space Heaters:- (i) The panels shall be provided with space heaters to prevent moisture condensation, and maintain cubicle temperature 5°C above the ambient. (ii) The space heaters shall be located at the bottom of the panel and shall be controlled through a double pole MCB and a thermostat with an adjustable setting range of 30 to 70°C. Space heaters shall be supplied from 240V AC auxiliary bus for a space heater. (iii) The work also include the interconnection of existing VCB Panel with complete bus bar connection arrangement and enclousure with above mentioned VCB Panel. The cost of the same must be included in the rates qouted by the contractor (iv) Any other item required to complete the job, is deemed to be included in the rate quoted by the contractor complete all as specified and directed.
Supply, fixing, testing & commissioning of 11KV, 630Amp, 26.3 KA Load Break Switch with Fuse Trip, Earth Switch, dynamic mimic arrangement, 230V AC Shunt Trip Coil and 2 NO + 2 NC Aux Contacts. 11KV HT HRC fuse rating: 100A Indication Lamps: (i) LBS off/ on Indication lamps - 1 Set (ii) Control wiringwith appropriate colours. (iii) Space Heater with ON/OFF Switch and Thermostat, and Fuses for AC colntrol, (iv) MS steel sheet enclosure suitable for Outdoor Type installation with MS base channel. (v) Provision for receving Incoming from side cable box and Outgoing cables through Bottom entry, Excluding Termination Kit and Glands. (vi) Bus Bar sizes: Main Bus 50x12mm -Aluminium : 1 Set (vii) Earth Bus : 40x 6 mm Aluminium : 1 Set (viii) Powder Coating Shade- Siemens Grey Ral 7032 ,complete all as specified and directed.
Supply installation testing and commissioning of copper wound step down outdoor type transformer , 11KV/415 Volts (at no load) AC 3 phase 50 Hz, 250 KVA capacity , core type , double copper wound oil immersed , naturally cooled , oil natural - air natural (ON AN) with external cooling tubes , delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group Dyn-11 with neutral brought out on secondary side (LV side) and having tapping at 0, + 2.5, + 5 % and + 7.5% on HV side to be changed by means of hand operated off load tap changer gear. Switch handle shall be provided with the locking aarrangement alongwith top position indicator. The maximum temprature rise should not exceed 45 degree C in oil and 55 degree C in HV/LV winding when measured by resistance method after continous full load run on an ambient temperature range upto (+)40 degree C. The transformer shall be IS -1180 Level -2 as specified and as directed including the following :- (a) Earthing terminal for body, Earthing bush Insulator for neutral. (b) Rating plate and terminal marking plate. (c) Air release device. (d) Oil filling inlet whole with cap /plug with connecting plate complete. (e) Drain outlet pipe with brass gate valve with dummy plug.
(f) Conservator with filter type drain valve and oil level guage. (g) De-hydrating breather with first fill dehydrating agent (Silica Gel). (h) First Oil filling of unused transformer oil IS335/93 (Fourth Revision) marked Filtered and tested upto the recommended level by the manufacturer with new oil conforming to IS 335 and 50 KV dielectric strength at 2.5mm air gap between testing electrodes. Accessories as per IS-1180 (Part-I) :2014. (j) Type of connection Delta/Star (k) Type cooling : ONAN (l) Vector Group : Dyn-11 (m) Type of connecting arrangement cable termination Insulator on HT side and termination box on LT side consisting of four Nos procelain bushing with copper rods, complete with nuts and washers, with two Nos cable glands suitable for reception/ taking out of XLPE insulated heavey duty armoured cables including glands, joints and jointing materials complete. (n) Provision of thermometer with pocket on tank cover. (o) Buchholz relay. (p) Oil and winding alarm and trip releay including marshal box (q) The Transformer shall be designed to function properly at high altitude of aprox. 1650 mtr above sea level in the region of Srinagar and outside temperature conditions between (-)10 Degree C to (+)40 Degree C. (r) Four plain solid cast steel detachable roller (wheels). (s) PCC Plateform of suitable size with steps. Note:- Certificate of di electric strength shall be submitted by contractor to Engineer in Charge.
Supply & Laying alongwith testing and commissioning XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas complete all as specified and directed.
Supply and Installation Arial bunched conductor having phase conductor of stranded compacted circular aluminium conductor screen of extruded semi conducting compound extruded XLPE insulated 11000 volts grade , insulation screen of extruded semi conducting compound over all metellic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS 7098 Part-II of size 3x95 sqmm + 1x 70 sqmm complete all as specified and directed
Supply & fixing danger notice plate of 1.6 mm thick mild steel sheet ,vitreous enamelled white with letters ,figures and conventional skull and bones in signal red colour and fixed with M S clamps,bolt and nut of approved size for LT 20 x 15 cm size complete all as specified and directed.
Supply & fixing danger notice plate of 1.6 mm thick mild steel sheet ,vitreous enamelled white with letters ,figures and conventional skull and bones in signal red colour and fixed with M S clamps,bolt and nut of approved size for HT 25 x 20 cm size complete all as specified and directed.
M & L for Stay assembly complete with accessories as shown in electrical plate No. 1 of 20 mm dia of stay rod, 180 cm long etc complete all as specified and directed. (for HT poles) complete all as specified and directed. NOTE :- Loop type insulator, stay clamps, excavation and concrete work shall be measured and paid separately.
Supply and fix loop type insulator vitreous procelain, white , brown or green, large size with overall dimensions 90mm x 140mm, clearence of hole 25.5mm dia complete all as specified and directed.
Supply and fix galvanised stay strand, 7/4 mm complete all as specified and directed.
Supply and fixing Cross arms bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, suitable for hanging hoock bending cold or hot, drilling holes for bolts, in any shape or size including making of ( HT Suspension Clamp, HT Dead end Clamp, Eye Hook, Pole clamp, Steel 'U' Clamp both end screwed with Nut, Bolts / Nails as Cable fastener with double ended metal Nails of 20mm dia & upto 50mm dia for fastening the cable over ceiling / surface of wall using Nails/ Screw of suitable size as directed and inclusive of one primar coat one under coat and one finishing coat of paint complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 6 sqmm 2 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 10 sqmm 2 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 16 sqmm 2 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 25 sqmm 2 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 6 sqmm 4 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 10 sqmm 4 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 16 sqmm 4 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 25 sqmm 4 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 35sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 50sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 70sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 95sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 120sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 150sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 185sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 240sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, laying , jointing and testing underground LT cable XLPE insulated heavy duty, galvanised steel strip or wire armoured, PVC sheathed multistranded,1100 Volts grade, of cross sectional area 400sqmm 3.5 core with aluminium conductor as per IS 7098 (Part-I) along with suitable size with aluminium cable lugs (bottle neck /eye let/ ring type as per ground requirement) and cable gland joint etc. laid in trenches, along poles passing through pipes, laid under floor, fixed on walls/roofs and passing under road etc complete all as specified and directed.
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type, double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 600 Amp rating for 3 phase and bus bar of same capacity of neutral as phase and 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location : Main LT Panel -1 Sub Stn 2 (S-3)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 300 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location : LT Panel -2 near Bldg P-15 (S-3)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 150 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location : LT Panel -3 near Bldg P-4 (S-3)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 100 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and outgoing accessories all as approved and comprising as under :- Location : LT Panel -4 near bldg P-23 (S-3)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 300 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and out going accessories all as approved and comprising as under :- Location : LT Panel - 5 near bldg P-22 (S-3)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 100 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over swicth / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and out going accessories all as approved and comprising as under :- Location : LT Panel - 6 near bldg P-21 (S-III)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bar of 1000 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and out going accessories all as approved and comprising as under :- Location : LT Panel - 1 near P-138 (S-I)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 300 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and out going accessories all as approved and comprising as under :- Location : LT Panel - 2 near bldg P 154A (S-I)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 200 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and out going accessories all as approved and comprising as under :- Location : LT Panel -3 Near P-149 (S-I)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 200 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and out going accessories all as approved and comprising as under :- Location : LT Panel - 4 near bldg P-143 (S-I)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 100 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and out going accessories all as approved and comprising as under :- Location : LT Panel - 5 near bldg P -157 (S-I)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 400 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and out going accessories all as approved and comprising as under :- Location : LT Panel -1 near bldg P-228 (S-II)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 200 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey siemens grey Ral - 7032 and provision for the following incoming and out going accessories all as approved and comprising as under :- Location : LT Panel - 2 near bldg P-126 (S-II)
Supply, installation, testing and commissioning of LT Control panel board, Outdoor type,double door, cubical type, padestal mounted, slopy roof, front and back both side opening, CPRI approved, IP -54 having independent compartment for bus bar, incoming feeder and each out going feeders, dust and vermin proof & lockable, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Aluminium bus bar of 200 Amp rating for 3 phase and bus bar of same capacity of neutral as phase 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set incl necessary copper cables of suitable size for MCCBs/MCBs / change over switch / inter connections, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each out going and in coming cables in cable alley panel board and painted with powder coating in siemens grey Ral - 7032 and provision for the following incoming and out going accessories all as approved and comprising as under :- Location : LT Panel - 3 near bldg P- 117 (S-II)
Dismantling and taking down the existing LT/HT insulators of any type from any description complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified and directed.
Dismantling and taking down of ACSR Conductor of any type from any description complete all as specified and directed.
Dismantling stay assembly complete all as specified and directed.
Material and labour for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground (earth plate not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level, connected to and including copper strip 20x3mm thick as earthing lead by means of bolts, nuts, check nuts and washers (brass), test points made of phosphorous bronze with finxing arrangements, 10 cm long, PCC (1:2:4) type B-1 in pit, angle iron 25x25x3mm frame work with precast RCC (1:2:4) type B-1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways and 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore perforated at bottom upto 1.75m length with funnel placed on top edge plate, wire mess and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead, salt, charcoal filling in layers, etc including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50m complete all as shown in electrical plate No. 3 of SSR Part-I and connected complete all as directed by GE including testing on completion. Note : The quoted rate of earthing shall be deemed to include cost of copper strip, protection pipe and watering pipe upto 7.5 metre. Any variation in length of earth wire shall be adjusted through deviation order.
Material and labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth plate not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level, connected to and including Galvanized Iron strip 32x6mm thick as earthing lead by means of steel bolts, nuts, check nuts and washers test points made of GI Strip 32x6mm, 10 cm long, PCC (1:2:4) type B-1 in pit, angle iron 25x25x3mm frame work with precast RCC (1:2:4) type B-1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways and 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mess and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead, salt, charcoal, etc including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50m complete all as shown in electrical plate No. 3 of SSR Part-I and connected complete all as directed by GE including testing on completion. Note : The quoted rate of earthing shall be deemed to include cost of Galvanized Iron strip, protection pipe and watering pipe upto 7.5 meter. Any variation in length of earth wire shall be adjusted through deviation order.
Material and labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth plate not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level, connected to and including Galvanized Iron wire 4mm dia as earthing lead by means of steel bolts, nuts, check nuts and washers test points made of GI wire 4mm dia, PCC (1:2:4) type B-1 in pit, angle iron 25x25x3mm frame work with precast RCC (1:2:4) type B-1 cover reinforced with 8mm dia TMT bars @ 150mm c/c both ways and 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mess and light grade GI protection pipe 40mm bore upto 5m length for drawing in earth lead, salt, charcoal, etc including excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50m complete all as shown in electrical plate No. 3 of SSR Part-I and connected complete all as directed by GE including testing on completion. Note : The quoted rate of earthing shall be deemed to include cost of Galvanized Iron wire, protection pipe and watering pipe upto 7.5 meter. Any variation in length of earth wire shall be adjusted through deviation order.
Supply & Fixing thermoplastic cable Junction Box/ Distribution Board IP-65 with metric knockouts for cable entry of size 10 to 25 sq mm x 4 core including two fastening clamp with nut bolts & washers , box size: 333 x 233x 120mm hinged cover with locking arrangements including with terminals TPN strip, with 01 No MCB SP 10A complete all as specified and directed.
Supply and fixing steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and erecting in trully vertical position including painting with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete all as specified and directed.
Supply and fixing steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-55 (11.0 mtr long) and erecting in trully vertical position including painting with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete all as specified and directed.
Cutting of road crossing / PCC hard standing for laying of pipe/ cable including making good the existing surface with same finish (PCC 1;3;6 type C2 40 mm graded stone aggregate and Bitumen) to match the original finish complete all as specified and directed.
Supply and fixing HT MS cable route indicator , engraved the description "HT CABLE 11 KV" on the disc not less than 6 inch dia and 6 mm thick welded with 40x6 mm MS strip of approximate length 90 cm duly painted on all steel parts as per colour code and provision of PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) of size (0.30x 0.30x 0.30)mtr burried under the ground including necessary earth work complete all as specified and directed. Note: Cable route drawing to be submitted by the contractor to Engineer in Charge.
Supply and fixing LT MS cable route indicator, engraved the description "LT CABLE" on the disc not less than 6 inch dia and 6 mm thick welded with 40x6 mm MS strip of approximate length 90 cm duly painted on all steel parts as per colour code and provision of PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) of not less than 0.05 cum in each at base burried under the ground including necessary earth work complete all as specified and directed. Note: Cable route drawing to be submitted by the contractor to Engineer in Charge.
Shifting of 400KVA Step down Transformer from MRS Sector-IV to Sector -I, distance upto 800Mtr. Shifting to be done by mechanical transport (Hydra/ Crane/ Tipper) taking down of transformer from PCC Plith of height 1.2 Mtr base and placing upon Plinth at Sector -I complete all as specified and directed. Note: Price are including of disconnecting of HT/ LT Cable from transformer and Re-connecting the same at new place Sector -I, all the necessary tools & Plants to brought by the contractor for shifting of transformer and cost for the same is deemed to be included in Quoted rates.
Supply & fixing of 100mm GI pipe light grade for protection of HT/LT XLPE cables in tranches/ Open in air/ Culvert / Drain/ with HT/ LT Pole complete all as specified and directed.
Supply & fixing of 80mm GI pipe light grade for protection of HT/LT XLPE cables in tranches/ Open in air/ Culvert / Drain/ with HT LT Pole complete all as specified and directed.
Supply & fixing of 50mm GI pipe light grade for protection of HT/LT XLPE cables in tranches/ Open in air/ Culvert / Drain/ with HT LT Pole complete all as specified and directed.
Supply & fixing of 40mm GI pipe light grade for protection of HT/LT XLPE cables in tranches/ Open in air/ Culvert / Drain/ with HT LT Pole complete all as specified and directed.
Material and labour for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) as in foundation for pole and mass concrete complete all as specified and directed.
Material and labour for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in coping of poles including use of form work and finishing all exposed faces of concrete as per clause 4.11.66 (a) & (d) of SSR Part-I complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide, or n exc 10 sq m on plan, depth not exc 1.5 m for foundation, etc. or for laying of cables, poles, pipes etc. and getting out in soft/loose soil complete all as specified and directed. Note :- Entire excavation shall be carried out manually only. No machinery such as JCB / excavator shall be used for excavation to avoid damage of existing electric supply / water supply / signal assets. This aspect shall be noted while quoting the Bid.
Excavation in trenches, n exc 1.5 m wide, or n exc 10 sq m on plan, depth exc 1.5 m but n exc 3.0 m for foundation, etc. or for laying of cables, poles , pipes etc. and getting out in soft/loose soil complete all as specified and directed. Note :- Entire excavation shall be carried out manually only. No machinery such as JCB / excavator shall be used for excavation to avoid damage of existing electric supply / water supply / signal assets. This aspect shall be noted while quoting the Bid.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning to under ground cables, with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable punned down upto 18cm and stretching the cable complete all as specified and directed. Note:- Measurement shall be taken only after punning down sand cushioning.
Supply and laying un-reinforced precast PCC cable Cover, class HV, ISI marked, type- I with flat, size 300mm x 180mm x 40mm for covering cables laid dry flat as cable protection on sand complete all as specified and directed.
Supply and laying un-reinforced precast PCC cable Cover, class LV, ISI marked, type- I with flat, size 250mm x 150mm x 40mm for covering cables laid dry flat as cable protection on sand complete all as specified and directed.
'Supply and fixing cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed.
'Supply and fixing cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, aluminium conductor cable of size 95 to 120 Sqmm complete all as specified and directed.
Material and labour for graded coarse aggregate (broken stone or boulders) of size 63 mm in sub - station yard as in hard core complete all as specified and directed.
Surface excavation as in soft/loose soil not exceeding 30cm deep and averaging 15cm deep and getting out complete all as specified and directed.
Supply and fixing PVC (SWR) pipes type A ISI marked single socketed in any length with rubber ring joints laid in trenhes or in floors, 110 mm dia complete all as specified and directed.
Material and labor for 60mm thick factory made Interlocking Concrete Paver Blocks (M-35 Grade) of any shape and size confirming to IS 15658-2006 with grey cement and no pigment complete all as specified and directed.
Material and labour for sand filling under paver blocks, with a layer of fine sand 50mm thick before laying of paver blocks complete all as specified and directed.
Material and labour for 75mm thick PCC type D-2 (1:4:8) using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for providing Plain Cement Concrete Type B1, (1:2:4) using 20mm stone aggregate cast in situ as in lintels upto 1.5m clear span, cills, and other similar bands, kerbs, water troughs and the like including weathering, slightly rounded or hamfered angles and throating, as directed and necessary form work, complete all as specified and directed. Note :- The size of kerb shall be minimum 200mm wide and 450mm high
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining blots etc including provision of binding wire complete all as specified and directed.
Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed.
Supply and fix hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed.
Supply and fix mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Material and labour for Mild Steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 410-W(Gde-E-250) Quality A complete all as specified and directed.
M&L for Mild Steel TMT bars 10 mm dia and over cut to length , bent to shape required, including cranking, bending spirally for hooping for column , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Supply and fix galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
M&L for preparation of new iron or steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Supply and fix glazed ceramic tiles coloured (Black) as in vertical surfaces such as skirting/dados and riser to steps area of tile 450x300x7mm thick, set, jointed and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
kailu construction co
M/S MIR & CO
ALCO ENGINEERSPVT LTD
Rajindera Enterprises
CHINAR CONSTRUCTION TRADERS
M/S Sky Engineers
Sant Construction Co.
M/S M.A. Construction
M/s Lal Enterprises
R D Bansal
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .