Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹43.7 LAccepted-AOC | 1 | Accepted-AOC The lowest tenderer | |
| 2 | 2₹47.6 L+₹3.9 L (8.87%)Rejected-Finance 1106 TIMES SQUARE ARCADE OPP RAMBAUG THALTEJ SHILAJ ROAD AHMEDABAD 380059 | AHMEDABAD | AHMEDABAD | GUJARAT | 380059 | 2 | Rejected-Finance Not the lowest tenderer | |
| 3 | Rejected-Technical FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹85,000
Closing Date
17 Mar 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
PROVN OF CERTAIN SANCTIONED WORKS OF AGE EM WS UNDER GE NW NAVY NAGAR COLABA MUMBAI
2021_MES_423532_1
8453/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE (NW) Navy Nagar, Colaba
Class D and category d(iv)
7 documents required · 7 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹85,000
31 Mar 2021
18 Feb 2021
18 Mar 2021
18 Feb 2021
17 Mar 2021
4 Mar 2021
18 Feb 2021 - 10 Mar 2021
60 days
Amount
Supply, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Valve Automation and communication Panel suitable for control and/or monitoring of 9 Nos motorized valves (+02 Spare) and 12 Nos. magnetic sensors (Fresh water Tanks-01 Nos.(4 Levels) Raw Water tanks -04 (2 Levels Each Tank). The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated. The Panel should have the following features:
Automatic Operation of Motor Actuated Valves The PLC based Panel shall consist of the follwing sub systems (a) 01 No PLC with follwing specifications:- (i) Suitable Digital inputs/ outputs, (ii) 4 serial ports supporting open communication protocol, 01 No. Ethernet port, (iii) Programming software based on IEC to facilitate building of custom built function blocks (iv) Expandable upto 192 DI / DOs.
01 No. SMPS of 5 A rating (Make: SCHNEIDER / NHP)
Suitable no. of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating. (Make: OEN / OMRON / IDEC / ALLEN BRADLEY)
MCB of rating 10A (Make: Havells/ Schneider),
Compatible with OFC based communication Ethernet Switch –16 port GBPS layer 2 manageable switch, Make Cisco, Dlink, Redundant GPRS modem based communication module comprising of one Main and One standby Modem with suitable antenna, modem controller and 02 Nos. data enabled SIM cards (01 No per modem) using two different service providers. The module shall be programmed to automatically toggle between the service providers based on the actual signal strength. switch to the stand by modem in case the main modem fails, Compatible for Wimax Connectivity if required. Location : Chenab Building
Supply, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Valve Automation and communication Panel suitable for control and/or monitoring of 02 Nos. Pumps, 02 Nos Pressure Transmitter, 02 Nos. Priming Motorised Valve, 02 Nos. Solenoid Valves, 2 Nos motorized valves (+02 Spare) and 02 Nos. magnetic sensors PrimingTanks-01(2 Levels), suitable number of energy meters and 01 Nos Ultrasonic level sensor, . The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated.
The Panel should comprise the following items:- (a) Water Level Sensing & Display (b) Pump On/Off (c) Auto priming (d) Operation of Motor Actuated Butterfly Valves (e) Automatic Toggling of Pumps (f) Auto Change Over In Case of Pump Failure (g) Single Phasing Prevention . (h) Manual Mode Operation (all connected sub systems including all valves (in pump houses and connected buildings / overhead tanks) and pumps from the PLC based Control Panel.
The PLC based Panel shall consist of the follwing sub systems:- (a) 01 No.PLC with follwing specifications; (i) Suitable Digital inputs/ outputs (ii) 4 serial ports supporting open communication protocol, 01 No. Ethernet port. (iii) Programming software based on IEC to facilitate building of custom built function blocks. (iv) Expandable upto 192 DI / DOs.
01 No SMPS of 5 A rating (Make: SCHNEIDER / NHP)
Suitable No of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating. (Make: OEN / OMRON / IDEC / ALLEN BRADLEY)
MCB of rating 10A (Make: Havells/ Schneider).
Compatible with OFC based communication Ethernet Switch –16 port GBPS layer 2 manageable switch, Make Cisco, Dlink, Redundant GPRS modem based communication module comprising of one Main and One standby Modem with suitable antenna, modem controller and 02 Nos. data enabled SIM cards (01 No per modem) using two different service providers. The module shall be programmed to automatically toggle between the service providers based on the actual signal strength. switch to the stand by modem in case the main modem fails, Compatible for Wimax Connectivity if required. Location : At PH for Chenab Building (Near Alaknanada)
Supply, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Valve Automation and communication Panel suitable for control and/or monitoring of 4 Nos motorized valves (+01 Spare) and 08 nos. magnetic sensors ( water Tanks-01(4 Levels) ). The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated.
The Panel should have the following features:- Automatic Operation of Motor Actuated Valves The PLC based Panel shall consist of the follwing sub systems (a) 01 No PLC with follwing specifications; (i) Suitable Digital inputs/ outputs, (ii) 4 serial ports supporting open communication protocol, 01 No. Ethernet port, (iii) Programming software based on IEC to facilitate building of custom built function blocks (iv) Expandable upto 192 DI / DOs.
01 No SMPS of 5 A rating (Make: SCHNEIDER / NHP)
Suitable No of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating. (Make: OEN / OMRON / IDEC / ALLEN BRADLEY)
MCB of rating 10A (Make: Havells/ Schneider).
Compatible with OFC based communication Ethernet Switch –16 port GBPS layer 2 manageable switch, Make Cisco, Dlink, Redundant GPRS modem based communication module comprising of one Main and One standby Modem with suitable antenna, modem controller and 02 Nos. data enabled SIM cards (01 No per modem) using two different service providers. The module shall be programmed to automatically toggle between the service providers based on the actual signal strength. switch to the stand by modem in case the main modem fails, Compatible for Wimax Connectivity if required. Location : AQ, AR, G and F Building
Supply, Installation Testing & Commissioning of Indoor type Programmable Logic Controller based Valve Automation and communication Panel suitable for control and/or monitoring of 8 Nos motorized valves (+01 Spare) and 16 nos. magnetic sensors (water Tanks-04 Nos.(4 Levels Each) ). The panel should be of suitable size fabricated from 2.0 mm thick CRCA sheet and properly powder coated.
The Panel should have the following features:- Automatic Operation of Motor Actuated Valves The PLC based Panel shall consist of the follwing sub systems (a) 01 No PLC with follwing specifications. (i) Suitable Digital inputs/ outputs. (ii) 4 serial ports supporting open communication protocol, 01 no. Ethernet port. (iii) Programming software based on IEC to facilitate building of custom built function blocks (iv) Expandable upto 192 DI / DOs.
01 No SMPS of 5 A rating (Make: SCHNEIDER / NHP)
Suitable no. of interposing relays 24 V D.C. coil rating, 4 pole and 2 A contact rating. (Make: OEN / OMRON / IDEC / ALLEN BRADLEY)
MCB of rating 10A (Make: Havells/ Schneider).
Compatible with OFC based communication Ethernet Switch –16 port GBPS layer 2 manageable switch, Make Cisco, Dlink, Redundant GPRS modem based communication module comprising of one Main and One standby Modem with suitable antenna, modem controller and 02 Nos. data enabled SIM cards (01 No per modem) using two different service providers. The module shall be programmed to automatically toggle between the service providers based on the actual signal strength. switch to the stand by modem in case the main modem fails, Compatible for Wimax Connectivity if required. Location : F2, F3 and F4 Building
Notes for above all PLC based control Panels for Ser item Nos 1.00, 2.00, 3.00 & 4.00 To make the system fully functional. all panels shall be consisting of the following :- (a) Rack mountable Web Smart Switch with 28 ports and POE for CPE hardware and following specifications:- (i) Number of Ports 24 10/100Base-TX Ethernet ports 2, 10/100/ 1000BASE-T 2 Combo 10/100/1000BASE-T/SFP. (ii) Port Standards & Functions • IEEE 802.3 10BASE-T Ethernet (twisted-pair copper) • IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted-pair copper) • IEEE 802.3x Flow Control • IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper) • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 Switching Capacity • 12.8 Gbps Make : Siemens, Dlink, Ubiquiti, Cisco
(b) Hot pluggable 1310 nm multimode/Single mode SFP (mini-GBIC) transceiver, supporting full duplex, Gigabit speeds on multimode/Single mode fiber for distances of up to 550m/550m/10km on 62.5µm/50µm/ 9µm respectively in a metal housing to reduce EMI and to increase durability Make : Dlink, Ubiquiti, Cisco, Siemens, HP
(c) Rack Mountable LIU with the following specifications:- (i) Rack Mountable 12 Port Unloaded LIU (ii) Aluminium Base Material (iii) Slim 1 U mounting height (iv) Metal Shelf Aluminium 1.2 mm thick (v) Splice tray Aluminium 0.6mm (vi) Winding Panel – Plastic (vii) Cable Plug – Rubber for minimum 2 cable entries (viii) Adaptor Panel Aluminium 1.5 mm thick (ix) 2 fiber spools built in for 900 um tight buffered fibre storing (x) Capable of storing upto 3 mts of 900 um tight buffered fibre per adaptor Make : Dlink, Ubiquiti, Cisco
(d) SC-LC Duplex SM Patch Cord 0.9 mm dia of suitable length (i) Size 0.9mm dia (ii) Insertion Loss <=0.2 db, max 0.3 db (iii) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (iv) Connector Ferrule Ceramic (v) Apex Offset <50um (vi) Fiber Height +-100nm (vii) End Face Radius of Curvature 7mm<R<25mm (viii) Repeatability <=0.2 dB 1,000 times mating cycles (ix) Working Temp -40deg C to +85 deg C Make : Dlink, Ubiquiti, Cisco
(e) SC Simplex Coupler/Adaptor (i) Insertion Loss <=0.2 dB for Zirconia Sleeve (ii) Sleeve/Ferrule Withdrawl Force 2.0N to 5.9N Make : Dlink, Ubiquiti, Cisco
(f) Adaptor Panel (i) 6 port adaptor Panel for SC Adaptors Make : Dlink, Ubiquiti, Cisco
(g) SC-SM-Simplex Pigtail of suitable length (i) Insertion Loss <=0.2 db, max 0.3 db (ii) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (iii) Connector Ferrule Ceramic (iv) Apex Offset <50um (v) Fiber Height +-100nm (vi) End Face Radius of Curvature 7mm<R<25mm (vii) Repeatability <=0.2 dB 1,000 times mating cycles (viii) Working Temp -40deg C to +85 deg C Make : Dlink, Ubiquiti, Cisco
(h) CAT6 UTP 24 AWG Patch Cord of suitable length, Plug 30U snag less Make : Dlink, Finolex
Seamless Integration of the above PLC Panels into the Existing SCADA System incorporating (a) Development: (i) SCADA Screens for new Updated Panel configuration (ii) Layout for App new Updated Panel configuration (iii) Report Format new Updated Panel configuration
(b) On-site development: (i) Modifications in SCADA Screens (ii) Modifications in reporting format (iii) Modifications in App layout
The quoted cost shall deem to include the cost of communication for 12 months from the date of completion.
Above All automation panel should connected to existing SCADA server and any other leftout devices and accessories require to commissioning should be consider and same should be include in quoted rates and department will not pay extra cost for the same. Make of Control Panel: Cimcon Software Pvt Ltd/ Reckronic Devices and Systems / Sombansi Schneider/Universal Switchgear.
Supply, Installation, Testing & Commissioning of Motor Actuated Ball Valve consisiting of suitable single phase Actuator and ball valve of size 50 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Material of Ball: Stainless Steel Limit Switches : 02 Nos.For open and close status In built Serial / USB communication Port In built data logger with memory In built SD Card In built blue tooth transceiver with capability of pairing with any android based smart phone to download logged data. Mounting :Direct on valve Make: EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL
Supply, Installation, Testing & Commissioning of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 80 mm dia with appropriate bracket/mounting arrangement including two Nos limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status In built Serial / USB communication Port In built data logger with memory In built SD Card Space Heater In built blue tooth transceiver with capability of pairing with any android based smart phone to download logged data. Mounting ::Extended type with universal joint for installation 18 -24 inches above ground level with angle mounting including raising of existing chamber if required. Make: EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL
Supply, Installation, Testing & Commissioning of Motor Actuated Butterfly Valve consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 100 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. Designed line pressure: 10 kg/sq cm. Operating Angle: 90 degrees Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status In built Serial / USB communication Port In built data logger with memory In built SD Card Space Heater In built blue tooth transceiver with capability of pairing with any android based smart phone to download logged data. Mounting ::Extended type with universal joint for installation 18 -24 inches above ground level with angle mounting including raising of existing chamber if required. Make: EMTORK / HASEL HOFENER / RITETORK /SIEMENS/ HONEY WELL
Supply, Installing,Testing and Commissioning of Ultrasonic Level Transmitter Range : 0-5 metres Accuracy : 0.5 % minimum Supply Voltage : 24V DC Output : 4-20 mA Ultrasonic Frequency:75 kHz burst, rep. rate 96 ms Delay at Power-up: 1.5 seconds Temperature Effect: Uncompensated: 0.2% of distance/°C &Compensated: 0.02% of distance/°C Delay at Power-up: 1.5 seconds Resolution: 1.0 mm Output Response Time: 100 ms to 2300 ms Minimum Window Size: 20 mm Environmental Rating: Leakproof design is rated IEC IP67; NEMA 6P Operating Conditions: Temperature: –20 °C to 70 °C (–4 °F to 158 °F) Maximum relative humidity: 100% Make : Endress/ Hauser/ Banner/ Krohnc/ Marshal/ Siemens
Supply, Installation, Testing and Commissioning of Float type Point Level Sensor with the following specifications; Type: Magnetic Magnet: Ring type Switch: Reed Switch (Epoxy sealed) Connecting Cable: Teflon Make: RECKTRONIC DEVICES AND SYSTEMS / TECHTROL / CRYSTAL
Supply & fixing on wall/ laying in trench 2 x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. (Make: POLYCAB/FINOLEX/RR CABLE)
Supply & fixing on wall/ laying in trench 4 x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. (Make: POLYCAB/FINOLEX/RR CABLE)
Supply & fixing on wall/ laying in trench 6 x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. (Make: POLYCAB/FINOLEX/RR CABLE)
Supply & fixing on wall/ laying in trench 5 pair 0.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. (Make: POLYCAB/FINOLEX/RR CABLE)
Supply, Installation, Testing and Commissioning of outdoor type Wimax CPE stations operating on license free frequency of 5 Ghz at suitable locations along with suitable antenna complete with mounting pole and accessories to be connected to the ofc network of each node and establish wireless connectivity with the central server. Make : UBIQUITI/ SIEMENS
Supply, Installation, Testing and Commissioning of outdoor type Wimax Base stations operating on license free frequency of 5 Ghz at suitable locations along with suitable antenna complete with mounting pole and accessories to be connected to the ofc network of each node and establish wireless connectivity with the central server. Make : UBIQUITI/ SIEMENS
Supply, Installation, Testing and Commissioning of Armoured CAT 6 UTP cable on walls Make : D Link, Finolex, Polycab
Supply, Installation, Testing and Commissioning of OFC Cable to be pulled over head and duly fastened/attached to a PVC cpoated messenger wire / stay wire of gauge either with the required clamps of suitable size not more than 3 feet apart or with a web between the OFC and messenger wire along with endplates at both ends of the suspended cable (a) 6F Single mode OFC suitable for outdoor networking applications (i) 6 Fibers type single mode, wavelength 1310, Attenuation 0.38/km (ii) Outer jacket of HDPE sheath (iii) Jelly Filled Core (iv) Wrapped with Corrugated Steel Tape (v) Armoured with a pair of Steel Wire for rigidity (vi) Anti Termite and rodent repellent (vii) Water Proof and moisture resistant Make : Finolex, Dlink
Supply & Installation of PVC Coated Suitable Dia GI messenger wire / stay wire of gauge either with the required clamps of suitable size not more than 3 feet apart or with a web between the OFC and messenger wire along with endplates at both ends of the suspended cable
Supply, Installation, Testing and Commissioning of HDPE PLB Duct with following specifications (a) Outside dia - 40mm + 0.4mm. (b) Wall thickness - 3.5mm ( + 0.2mm / 0.00mm) (c) Thickness of permanent lubricant more than 0.4mm splicing and terminating as specified. Make of Duct : Anek / Swastik / Appolo
Excavation in trenches not exceeding 1.5 mtr wide not exceeding 1.5 mtr in depth and getting out in soft/loose soil all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil all as specified.
Removing excavated material exc 150 M but n.exc 500 M and depositing where directed all as specified.
M&L for earthing with glvanised earth plate 60 cmmx60cmx6mm thick buried directly in ground verticaly to depth not less than 2.5 mtr deep below ground level connecting 25x4mm GI strip by means of bolt nut chek nut and washer of galvanised iron all show in electrical plate no 03 SSR Part I including necessary exvation earth in soft/loose soil concrete pit in PCC 9 and (1;2:4) pre cast iron pit and pit cover with handle of 8 mm dia MS rod and connected to test point and aluminum strip of 25x3mm with insulator strip between from panel on terrace to earth pit all as specified and directed
Supply, Installation Testing & Commissioning of motor actuated ball valve suitable for 25 mm GI pipe for priming of pump including all necessary GI fittings with following specifications: Size: 25 mm Pressure rating: 10 kg / sq. cm. Make: Danfoss / Siemens / E & H
Supply, Installation Testing & Commissioning of direct acting type release solenoid valve for air release during priming; with follwing specifications : Size: 10 mm Pressure rating: 10 kg / sq. cm. Type: Normally closed Make: Danfoss / Siemens / E & H
Supply, Installation Testing & Commissioning of pressure Transmitter with following specification including necessary power pack for supply of DC : Power supply: 10-36 V DC Process connection: G ½ “ Enclosure: whether proof IP 65 Process temperature: -30 to 120 celcius Accuracy: 0.25 % Make: Danfoss / Siemens / E & H
CIMCON SOFTWARE INDIA PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .