| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹35.6 LAccepted-AOC DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | 1 | Accepted-AOC Being Lowest Bidder | |
| 2 | 2₹36.9 L+₹1.2 L (3.39%)Rejected-Finance BIRD LINE CALICUT POST SRI VIJAYA PURAM SOUTH ANDAMAN 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | 2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | 3₹37.0 L+₹1.3 L (3.63%)Rejected-Finance | 3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | 4₹39.5 L+₹3.8 L (10.5%)Rejected-Finance DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | 4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | 5₹49.2 L+₹13.5 L (37.7%)Rejected-Finance B 33 171 PATEL NAGAR GURDASPUR ROAD PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | 5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
22 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Pankaj Vyas, IDSE, Commander Works Engineer N
Commander Works Engineers No. 2, Brichgunj, Port Blair - 744 103
Maintenance and Repair to HT Distribution Network and Other Items under GE Brichgunj, Port Blair
2023_MES_582346_1
80280 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Port Blair
Class D
Category b ii
9 documents required · 9 mandatory
₹500
Garrison Engineer Brichgunj
₹78,000
Yes
25 Apr 2023
22 Feb 2023
29 Mar 2023
22 Feb 2023
22 Mar 2023
8 Mar 2023
22 Feb 2023 - 1 Mar 2023
Amount
M & L for Straight Through Joint, Heat Shrinkable type, suitable for 11000 Volts Grade, 3 Core, 50 to 95 Sq.mm, HT, XLPE Insulated, Armoured Power Cable Aluminium Conductor and testing after jointing including dismantling old cable joint of any description and necessary return filling, etc. complete all as specified and as directed.
M & L for Straight Through Joint, Heat Shrinkable type, suitable for 11000 Volts Grade, 3 Core, 120 to 185 Sq.mm, HT, XLPE Insulated, Armoured Power Cable Aluminium Conductor and testing after jointing including dismantling old cable joint of any description and necessary return filling, etc. complete all as specified and as directed.
M & L for Cable End Termination Joint, Heat Shrinkable type, Outdoor type, suitable for 11 kV Grade, 3 Core, 50 to 95 Sq.mm, HT, XLPE Insulated, Armoured Power Cable with Aluminium Conductor and testing after jointing including dismantling old cable joint of any description complete all as specified and as directed.
M & L for Cable End Termination Joint, Heat Shrinkable type, Outdoor type, suitable for 11 kV Grade, 3 Core, 120 to 185 Sq.mm, HT, XLPE Insulated, Armoured Power Cable with Aluminium Conductor and testing after jointing including dismantling old cable joint of any description complete all as specified and as directed.
M & L for Cable End Termination Joint, Heat Shrinkable type, Indoor type, suitable for 11 kV Grade, 3 Core, 50 to 95 Sq.mm, HT, XLPE Insulated, Armoured Power Cable with Aluminium Conductor and testing after jointing including dismantling old cable joint of any description complete all as specified and as directed.
M & L for Cable End Termination Joint, Heat Shrinkable type, Indoor type, suitable for 11 kV Grade, 3 Core, 120 to 185 Sq.mm, HT, XLPE Insulated, Armoured Power Cable with Aluminium Conductor and testing after jointing including dismantling old cable joint of any description complete all as specified and as directed.
M & L for Cable End Termination Joint, Heat Shrinkable type, Outdoor type, suitable for 33 kV [E] Grade, 3 Core, 95 Sq.mm, HT, XLPE Insulated, Armoured Power Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.
M & L for identifying the Earth Pits, improving the Resistance of existing earth pit by pouring Salt Water / Salt in earth pit to improve resistance up to 2 Ohms and measuring the earth resistance and making record complete all as specified and as directed.
S & F in repairs Silica Gel Breather of capacity 250 Grams made of Aluminium top and bottom, Transparent unbreakable centre portion to check Silica Gel condition, clear view Polycarbonate Oil Cup, Screwable type, Air Tight, Centre Tie Rod Connection of ½ or ¾ thread or Flange suitable of mounting in Transformers of capacity up to 400 KVA complete all as specified and as directed.
S & F in repairs Silica Gel Breather of capacity 1 KG made of Aluminium top and bottom, Transparent unbreakable centre portion to check Silica Gel condition, clear view Polycarbonate Oil Cup, Screwable type, Air Tight, Centre Tie Rod Connection of ½ or ¾ or 1 inch thread or Flange suitable of mounting in Transformers of capacity 2 MVA complete all as specified and as directed.
M & L for preparation of old surfaces of 11 Metre high RCC Poles and applying one coat of cement based paint on RCC Poles including painting black and yellow strips of 30 cm each on poles up to 1.0 m from the bottom and numbering with 60mm size letters with synthetic enamel paint complete all as specified and as directed.
S & F Pin type Composite Silicon Rubber Polymeric type Insulator of 150mm height, 150 mm dia for 11000 Volt Grade including one galvanized MS Spindle, Nuts & Washers and fixing to the structure and binding the conductor including taking down existing unserviceable insulators of any description from HT 2 Pole / 4 Pole Structure complete all as specified and as directed.
S & F Pin type, Porcelain, Vitreous White, Brown or Green Insulator of 150mm height, 150 mm dia for 11000 Volt grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut and fixing to the structure and binding the conductor including taking down existing unserviceable insulators of any description from HT 2 Pole / 4 Pole Structure complete all as specified and as directed.
S & F Post Top Insulator, Double Stack [2 X 22 KV Each], Porcelain, Vitreous White, Brown or Green for 33000 Volt grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut and fixing to the structure and binding the conductor including taking down existing unserviceable insulators of any description from HT 2 Pole / 4 Pole Structure complete all as specified and as directed.
M & L for Graded Stone Aggregate filling of gauge exceeding 40mm and not exceeding 63mm including spreading and levelling in layers, tightly packed, of 150mm thick, alround the Transformer, Two Pole / Four Pole Structure, LT / HT Panels, Substation complete all as specified and as directed.
M & L for RCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Walls, Retaining Walls, Basement Walls, Ballast Walls and the like, any thickness above top of footings including attached pilasters and buttresses etc complete all as specified.
S & F in repairs Silica Gel into Breather of Transformers complete all as specified and as directed.
Supply and topping up of Transformer Oil [EHV Grade-II for topping up of Transformer Oil duly filtered, ISI Marked, Conforming to IS – 335] with di-electric strength not less than 60 KV in to the Conservator Tank / Body Tank of the Transformer etc. complete all as specified and as directed. Make: Power Oil / Transol / Sabitha Chemicals
M & L for Filtration of Transformer Oil of transformers installed at various locations at Brichgunj Military Station to achieve di-electric strength not less than 60 KV at 2.5mm gap as per relevant IS with Portable Filtration Plant, testing of the oil for the di-electric strength / insulation value before filtration and after filtration complete all as specified and as directed. Note: Oil for topping up shall be measured and paid for separately as supply only under relevant items of this schedule.
Supplying, laying and testing HT UG Cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 11000 Volts grade [heavy duty] suitable for Earthed System with aluminium conductor of size 3 Core, 95 Sq.mm conforming to IS – 7098 [Part – II] laid in trenches, fixed to walls or passing through pipes and connecting up including taking down old HT Cables of any description complete all as specified and as directed. Note: Earthwork excavation shall be measured and paid separately under relevant items of this Schedule.
M & L for repair and overhauling of HT 11 KV Vertical Air Break Switch, Outdoor type by cleaning the contacts, applying grease and replacement of defective unserviceable spare parts for easy operation on ground level complete all as specified and as directed. Note: All spares required to be replaced shall be measured and paid separately under relevant items of this schedule. Cost of minor items like nuts, bolts, washers etc. are deemed to be included in the quoted rate.
Supply only Male Contact / Moving Contact Blade suitable for 11 KV complete all as specified and directed.
Supply only Female Contact / Fixed Contact Jaw suitable for 11 KV complete all as specified and as directed.
Supply only MS Jumper Carrier complete all as specified and as directed.
Supply only Tinned Copper Flexible Jumper 200 amps complete all as specified and as directed.
Supply only Top Contact / L Contact for Drop Out Fuse suitable for 11 KV complete all as specified and as directed.
Supply only Bottom Contact for Drop Out Fuse suitable for 11 KV complete all as specified and as directed.
S & F in repairs DO Fuse Elements 5 to 20 Amps rating complete all as specified and as directed.
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
M & L for Earthing complete with Copper Earth Plate Electrode 600 X 600 X 3.15 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to Copper Strip of size 32 X 6mm [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in Hard / Dense Soil for laying Cables / Pipes etc. complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
Supplying and laying un–reinforced Precast Concrete Cable Cover, Class HV, Type 1, Flat, of size 300mm x 180mm x 40mm made out of M-20 Grade PCC as per IS – 5820 for cable protection, embossed with "ELECTRIC" on top surface complete all as specified and as directed.
M & L for dismantling Oil filled CT/PT from structure at 33 KV Switchyard after switching off supply and carefully removing electrical connections, checking the IR Value, opening the top cover by taking down the bolts and nuts, draining oil, checking the Dielectric Strength of drained oil, filtration / dehydration and building up the BDV Value not less than 50 KV, refilling the oil, fixing back the top cover with new gasket and tightening bolts to restrict any leakage, cleaning terminals, scrapping thoroughly the existing corroded paint / rust, filling the cavities with suitable filler material & painting with one coat of silicon acrylic heat resistant paint of approved quality and colour, mounting back the PT / CT and connecting all necessary electrical connections complete all as specified and as directed.
M & L for decarbonising / cleaning complete HT Panel Boards, 11 KV, Cubicle type, consists of Busbar Chamber, Circuit Chamber and Metering Chambers, by opening the spout / bus covers inspecting the Busbar joints, cleaning of Busbars, checking the Busbar Spouts and Circuit Spouts for any Flash Overs / Tracks, applying Becktol [Red] solution to the Busbars and Spouts having moderate tracking, applying HT Insulated Red Compounds / Monoplast Compound at the busbar joints after tightening of joints, cleaning of busbar insulators and busbars with CTC and ensure proper decarbonisation and re-assembling complete all as specified and as directed.
M & L for decarbonising / cleaning the cable compartment of Ring Main Unit, 3 Way, 11 KV, consists of End Joints, Current Transformers, Cable Boots, Bushings, by opening compartment cover by carefully switching off the main input cable supply and necessary switching ON of Earth switch of RMU thereby inspecting the end joints, current transformer, bushings and cable boots, checking the bushings for any flash overs / tracks, applying Becktol [Red] Solution to the bushings having moderate tracking, applying suitable HT insulated tape over anti tracking tube to prevent further tracking on, cleaning of end joints, CTs & cable boots with CTC and ensure proper decarbonisation and re-assembling complete all as specified and as directed.
All as per Serial Item No. 38 above but of RMU 4 Way complete all as specified and as directed.
All as per Serial Item No. 38 above but of RMU 6 Way complete all as specified and as directed.
All as per Serial Item No. 38 above but of RMU 10 Way complete all as specified and as directed.
All as per Serial Item No. 38 above but of RMU 1 Way complete all as specified and as directed.
M & L for Servicing and Testing of HT Vacuum Circuit Breaker of capacity up to 1250 Amps, 33 KV of any make comprising of the following including testing complete all as specified and as directed and to the entire satisfaction of Engineer-in-Charge: Note: Rate quoted is deemed to be inclusive of the following services: [i] Checking the serviceability of the following parts carefully including cleaning, adjustments and re-assembling the unit complete. [ii] Checking the spring charging mechanism of the VCB, checking the operations of the closing/tripping trough closing/tripping coils electrically as well as manual charging including cleaning adjustments complete for the following. [iii] Checking the condition of the spring charging motor along with gear box including servicing to the Motor Commutator Bushes, lubrication of bearing surfaces etc. [iv] Cost of additional hardware like, bolts, nuts, washers and spring washers, Petroleum Jelly CTC, to put the breaker in serviceable condition is deemed to be included in the rates quoted. [v] Carrying out minor repairs for all the non functional circuits and indicating system like VCB Trip, CB ON, CB OFF, CB Service, Spring Charging etc. for their efficient functioning. [vi] Test shall include IR, CRM, time Test and all relevant routine test at site including submission of test reports. [vii] The above VCB servicing shall be carried out through authorised service agency of OEM only.
Taking down the HT Vacuum Circuit Breaker of capacity up to 800 Amps, 11 KV of any make for Servicing and Re-assembling of any make comprising of the following including testing complete all as specified and as directed and to the entire satisfaction of Engineer-in-Charge: Note: Rate quoted is deemed to be inclusive of the following services: [i] Taking out the VCB from the enclosure & checking the serviceability of the following parts carefully including cleaning, adjustments and re-assembling the unit complete. [ii] Cleaning the external surface of bushings with CTC/CRC or Liquid ammonia to remove the accumulation of dirt or any other deposits. Inspection of bushings and make sure that vibration due to breaker operation have not caused the bushings to move resulting misalignment of contacts. [iii] Checking the breaker bushing of busbar and circuit side inspecting the interval surface carefully for any Charging / Trackings, replacement of bushings. [iv] Dismantling the spring charging mechanism of the VCB, checking the operations of the Closing / Tripping trough Closing / Tripping Coils electrically as well as manual charging including cleaning adjustments complete for the following. [v] Checking the condition of the spring charging motor along with gear box including servicing to the motor commutator bushes, lubrication of bearing surfaces etc. [vi] Cost of additional hardware like, Bolts, Nuts, Washers and spring washers, Petroleum Jelly CTC, to put the breaker in serviceable condition is deemed to be included in the rates quoted. [vii] Making functional by carrying out minor repairs all the Non-functional circuits and indicating system like VCB Trip, CB ON, CB OFF, CB Service, Spring Charging etc. [viii] Test shall include IR, CRM and time Test. [ix] The above VCB servicing shall be carried out through authorised service agency of OEM only.
Supply only Spring Charging Motor suitable for operating in 240 V AC supply to be fixed in 11 KV VCB complete all as specified and as directed. Make: as per existing OEM as approved by GE
Supply only Anti Pumping Relay, 30 Volts DC for VCBs complete all as specified and as directed.
Supply only Trip Circuit Coil, 30 Volts DC suitable for 11 KV Siemens / Crompton make VCBs complete all as specified and as directed.
Supply only Trip Circuit Coil, 30 Volts DC suitable for 33 KV Siemens / Crompton make VCBs complete all as specified and as directed.
Supply only Space Heaters 230 Volts, 80/100 W suitable for fixing inside VCB Chamber along with necessary wiring complete all as specified and as directed.
S & F in repairs Thermostat for Space Heaters of Range 30°C - 110°C suitable for fixing inside VCB Chamber including wiring complete all as specified and as directed.
S & F in repairs Trip Neutral Close [TNC] Circuit breaker control Switches with 2 NO+ 2 NC contact arrangement of 25 A rating complete all as specified and as directed.
S & F in repairs Right Angled Cable Boot Cover Cold type Push on suitable to cover the end connections of HT Cable of size 3 Core, 95 Sq.mm connected to 11 KV, 630 A Siemens Make 8DJ HST Model RMU complete all as specified and as directed.
M & L for taking down old deteriorated Earth Chamber Pit by making new concrete pit in PCC [1:3:6] Type C1, Precast RCC [1:2:4] Type B1 as in Cover Slab of size 540 X 540 X 50mm including 8mm dia TMT Bars @ 150 mm c/c as in reinforcement with one handle for lifting made out of 8 mm dia TMT Bars, funnel for watering along with necessary excavation earthwork in any type of soil complete all as specified and directed.
S & F in repairs Digital Type, Three Phase Ampere Meter with programmable CT Accuracy Class 0.5 complete all as specified and as directed. Catalogue No. WL131020OOOO of L & T or equivalent as approved by the GE.
S & F in repairs PVC Cable Trunking Covered Duct FRLS type of size 75 X 75 mm including Duct Cover with all Fitting & Fixtures complete all as specified and as directed.
M & L for Calibration of Microprocessor based Numerical Relay / Differential Relay by conducting Primary Injection on respective CTs and Secondary Injection tests on Relays, checking of Current Transformer including CTR Ratio, IR Value, CT Secondary Resistance Measurement Test, rectification of defects in Control Wiring for proper tripping of circuit breakers through CTs, Relays and Tripping Coils, adjustment / setting of the Relay to restrict fault to upstream breakers, re-installation of the relay in circuit complete all as specified and as directed. Note: [a] The contractor shall provide necessary testing kits, testing equipments, tools etc. and shall also prepare the detailed test reports panel wise duly bound and submit to the department. Rate quoted is deemed to be inclusive of cost of the kits and equipment as required. Testing and turning shall be carried out in the presence of Engineer-in-Charge to the satisfaction of department, failing which payment for the above item will not be made to the contractor. No claim from the contractor be entertained on this account. [b] Rate is inclusive of setting the parameters in differential relay and connecting after carrying out necessary polarity tests etc [c] Test report shall be submitted separately.
S & F Earth continuity Conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F Earth continuity Conductor or main earthing lead made of Copper Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs of 3.6V Cell, DC, Lithium - 1/2 AA size [ER 14250] suitable for C & S make [CSPR – V5 Model] Protection Relay fixed in RMU complete all as specified and as directed.
S & F in repairs Door Hinges suitable for Siemens Model 8DJHST RMU after removing the old broken hinges complete all as specified and as directed.
M & L for Cross Arms, Bracings of any size including Supports, Clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including applying two coat of aluminium paint over a coat of red oxide primer after preparation of new steel surfaces including dismantling of existing old cross arms, bracings of any size complete all as specified and as directed.
Supply, install, testing and commissioning of Air Break Switch, Gang Operated, Vertical type, Triple Pole, Outdoor type of capacity 200 Amps, Mechanically Operated, Mounted on 12 Nos Insulators and Steel Frame, with Operating Mechanism working from ground level complete with locking arrangements complete including Fuse Mounts, Fuse Carriers and Fuse Element having 20 Amps Current Rating, 11000 Volts and Insulators suitable for 11 KV, HT, 50 Hz including GI Pipes and all other materials and taking down old unserviceable AB Switch complete all as specified and as directed.
S & F in repairs 3 Pole Power Contactor of 9 Amps Rating with 1 NO and 1 NC with Coil Voltage 110 V AC including Add on Blocks with 2 + 2 NO & NC including necessary wiring and DIN Rail complete all as specified and as directed.
S & F in repairs HT, PT Fuses of Porcelain insulated 11/12 KV, Breaking Capacity 45 KA, 3.15 Amps rating capacity complete all as specified and as directed. Make: English Electric / Bussmann
S & F in repairs SMPS suitable for AC 230V, 50 Hz as input and DC 110V, 1A as output with Overload / Overvoltage and Short Circuit Protection including mounting on Panel complete all as specified and as directed.
S & F in repairs 11 KV Single Phase Current Transformer [CT's] conforming to IS – 2705, VA Burden – 15VA, Class of Accuracy - 0.5/5P-10, Three Core Type of CT as per existing with CTR100-50/5-5A complete all as specified and as directed.
S & F in repairs 11 KV Single Phase Current Transformer [CT's] conforming to IS – 2705, VA Burden – 15VA, Class of Accuracy - 0.5/5P-10, Three Core Type of CT as per existing with CTR200-100/5-5A complete all as specified and as directed.
S & F in repairs and Testing of PT Assembly, 11 KV Grade, Dry Type suitable for 800 A VCB, Class 0.5, Capacity 100 VA, 11000 / √3 / 110 / √3 insulation level 12 / 28 / 75 KV, Voltage Factor 1.2 continuous etc. including taking down of old and unserviceable PTs from VCB Panel etc. complete all as specified and as directed.
S & F in repairs of Dial type 100mm dia Oil Temperature Meter suitable for 100 KVA to 400 kVA, 11KV / 433V Transformers complete all as specified and as directed.
S & F in repairs of HV Side Brass Studs, threaded both ends of suitable size and length including Metal and Rubber Rings, Bolts, Washers etc., suitable for 100 to 400 KVA Transformer, Indoor or Outdoor type, 11KV/433V, Step Down of any Make / Model complete all as specified and as directed.
S & F in repairs of LV Side Brass Studs, threaded both ends of suitable size and length including Metal and Rubber Rings, Bolts, Washer, etc., suitable for 100 to 400 KVA Transformer, Indoor or Outdoor type, 11KV/ 433 V, Step Down, of any Make / Model complete all as specified and as directed.
Supplying and laying GI pipe, 100mm dia, Light grade for cable protection including all fittings complete laid in trenches / floors at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
Supplying and laying GI pipe, 50mm dia, Light grade for cable protection including all fittings complete laid in trenches / floors at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
Supplying, laying and testing 33 kV Grade, Earthed System, [Heavy Duty], UG Cable, with Aluminium Conductor of size 3 Core, 95 Sq.mm, suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE Insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS – 7098 [Part – II] and manufactured using VCV manufacturing process, laid in trenches, fixed to walls or passing through pipes and connecting up complete including taking out unserviceable cable complete all as specified and as directed.
S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Duct Covers [Plain & Chequered] of thickness as directed by Engineer-in-Charge with frame made of Angle Iron of approved section, complete drilled / welded for fixing of steel covers / hanging or sliding with and including hooks complete including preparation of surfaces and applying two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer and including dismantling existing duct covers of any description complete all as specified and as directed.
M & L for shifting after disconnecting HT/LT connections of Transformer up to 300 kVA 11KV/433V, shifting from any location inside Brichgunj Military Station and connecting HT/LT side to provide power supply at other location complete all as specified and as directed.
S & F in repairs Terminal Clamp along with Bimetallic Strip made up of Aluminium along with Bolts, Nuts and Washers suitable for ACSR Conductor to be fixed on 33 KV AB Switch complete all as specified and as directed.
S & F Earth continuity Conductor or main earthing lead made of GI Strip of size 75 X 8mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. or buried in 33/11KV Yard after removing the aggregates, connecting to existing system by electric welding and GI Bolts / Nuts / Washers and refilling the aggregate complete all as specified and as directed.
S & F Earth continuity Conductor or main earthing lead made of GI Strip of size 50 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. or buried in 33/11KV Yard after removing the aggregates, connecting to existing system by electric welding and GI Bolts / Nuts / Washers and refilling the aggregate complete all as specified and as directed.
M & L for painting on old surfaces HT Panel / Steel Structures by spray paint after cleaning strains and grease / oil spots with sand paper & thinner and applying two coats of synthetic enamel paint of existing colour to achieve good finish by spray painting machine carefully after disconnection of power supply and covering the meters, indicators nameplates and switches to prevent from paint drops complete all as specified and as directed.
S & F in repairs of Single Phase Potential Transformer [PT's] conforming to IS – 3156, Ratio 33kV / R3 / 110V / R3, Burden – 50 VA, Class of Accuracy – 0.2, Frequency 50 Hz, Voltage Factor: 1.2 Continuous & 1.5 for 30 Second, Ins Level: 70kV / 170kVp, INS Class-A, Vk > 50V [Core 1 & 4] Type of C, complete including first fill of Transformer Oil complete all as specified and as directed.
S & F Aluminium Conductor Steel Reinforced [ACSR] of any type including binding with and including suitable size of binding wire / crimping lugs of suitable size / connecting to clamps with suitable GI bolts, nuts and washers complete Including dismantling and taking out worn out ACSR conductor from 33 KV Yard complete all as specified and as directed.
S & F in repairs Copper Tube for Busbar of size min 20mm outer dia on 33 KV tower including bracing and jointing tube, connecting clamps and tightening the busbars over the insulators including disconnecting the old copper tube bus bars all as specified and as directed. Note: Thickness of the bus bar shall be as per the sample complete all as specified and as directed.
S & F in repairs Maintenance Free Battery for RMU 12V, 7Ah capacity complete all as specified and as directed.
M & L for servicing of transformer of 2 MVA capacity, 33/11 KV ratio and carrying out preventive maintenance, technical inspection and testing by highly skilled / specialist mechanic / technician experienced in working on HT 33 KV line complete all as specified and directed. Note: [a] Checking of winding temperature & oil temperature. In case of unsatisfactory condition shut down the transformer and investigate if either is persistently higher than normal. [b] Checking of oil level and examine transformer for oil leaks. [If low level, toping up with transformer oil, which shall be measured & paid separately]. [c] Checking of Dehydrating breather of silica gel [Replacement silica gel if required will be measured & paid separately] [d] Checking and cleaning of primary & secondary bushing from dirt and oil. [e] Checking of oil dielectric strength and presence of water moisture. [f] Checking, cleaning & testing of relays, alarm signal & contacts, fuses, circuits, their operation including change in setting, if necessary complete [g] Checking & testing of earth resistance. [h] Checking & testing of insulation resistance of windings [j] Checking of cable box condition. [k] Checking & tightening of bolts/nuts and other loose metallic parts. [l] Taking expert opinion in case of abnormal noise, abnormal temperature, electrical faults, alarm signal through Buchholz Relay etc. [l] Painting of the transformer with two coat of synthetic enamel paint [m] Checking leakages from entire transformer and replacement of gasket / packing [n] All testing tools, equipments and other T & P, hydra for lifting top cover of transformer required for technical inspection, T & P required for replacement of packing shall be provided by the contractor and the rate quoted is deemed to be inclusive of the same. [o] The Transformer servicing shall be carried out through authorised service agency of OEM only.
Servicing to Air-Break Switch / Isolator, Off load, Rotating type, 33 KV, 600 Amps capacity with proper alignment of isolator rotating blades with fixed contact jaws, arcing horns, applying petroleum jelly to moving mechanism, cleaning and lubricating to isolator control assembly, tightening all nuts, bolts of isolator assembly and clamps of jumpers etc, repairing to isolator control assembly and making in to proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and as directed.
S & F in repairs Male / Moving Contact / Rotating Blade made of HDE Copper, Silver plated of Air Brake Off Load Isolator Switch, Rotating type 33 KV, of 600 Amps capacity with all fixing nuts, bolts etc. complete all as specified and as directed. Make: Kurgg / Pactil / Jaipuria / BHEL.
S & F in repairs Fixed / Female Contact made of HDE Copper, Silver plated of Air Brake Off Load Isolator Switch, Rotating type 33 KV, of 600 Amps capacity with all fixing nuts, bolts etc. complete all as specified and as directed. Make: Kurgg / Pactil / Jaipuria / BHEL.
S & F in repairs outdoor type 400 Amps nominal current rated, 33 KV, 3 Phase, Triple Pole, Double Break, Gang Operated, Centre Rotating type Isolator with Gang Operated Earth Switches, including Insulators and complete in all respects with Arcing Horns, Bimetallic Connectors, Operating Mechanism Devices, fixing complete with GI operating pipe of heavy duty complete all as specified and as directed. The isolator shall comply the following: [i] System frequency with + 3 % variation [Hz]: 50 [ii] Nominal system voltage [KV RMS]: 33 [iii] Maximum system voltage [KV RMS] / Rating Voltage: 36 [iv] Maximum continuous current rating [Amps]: 400 [v] Rated short time current for 3 Seconds [KA RMS]: 28.8 [vi] Rated peak withstand current [KA Peak]: 72 [vii] 1.2/50 Micro-sec Lightning Impulse withstand Voltage [KV Peak] [a] To earth and between Poles: 170 [b] Across the isolating Distance: 195 [viii] Rated one minute power frequency withstand Voltage [KV RMS] [a] To earth and between Poles: 70 [b] Across the Isolating Distance: 80 [ix] No. of Poles: 3
Note: The rate quoted is deemed to be inclusive of the following: [a] Each pole unit of the multipole Isolators shall be of identical construction and mechanically linked for gang operation. [b] All isolators as given in the schedule of requirements shall be suitable for horizontal upright mounting on structure. [c] Moving contacts of all isolators shall rotate through 90° from their “Fully Closed Position” to “Fully Open Position” so that the break is distinct and clearly visible from ground level. [d] Fixed guides shall be provided so that even when the blades are out of alignment by one inch [maximum] at the time of closing of switches, proper seating of the blades in between the contacts and adequate pressure to give enough contact surface are ensured, whenever possible, the blades shall be counter balanced by weights & springs at the end of the travel both on opening and closing of the isolator. The springs shall be made of durable and non-rusting type alloy.
S & F in repairs of 3V Cell, DC, lithium [CR 2/3AZ] 1600 mAh suitable for Siemens make Protection Relay fixed in RMU complete all as specified and as directed.
S & F in repairs of 3.6V Cell, DC, lithium [ER14505] min 2000 mAh suitable for Fault Passage Indicator [FPI] fixed in RMU complete all as specified and as directed.
Servicing / Maintenance of Transformer of capacity up to 160 KVA, 11 / 0.433 KV, Indoor / Outdoor type, Plinth mounted type including the following work services: [a] Disconnecting transformer from electric system and providing electric power to user through alternative arrangement including taking out from existing position. [b] Decanning of Transformer Oil, opening top cover, disconnecting of all internal connections, lifting and taking out of Core Assemble, LT / HT Bushes, Tap Changer etc. cleaning and inspection of core and winding, segregation of serviceable and unserviceable items, removing of sludge and cleaning tank and Cooling Pipes / Fins / Tanks and drying the tank complete. [c] Replacing unserviceable LT / HT bushing by replacing Rubber / Cork Oil Seals and damaged Terminal Rod & replacement of Transformer Cover Gasket made of Rubber Cork Sheet. [d] Re-installation of Transformer including reassembling of core / winding assembly complete including replacement of unserviceable parts, repair the defective parts and tightening of all loose / sparks wire / nuts, bolts etc. and refixing the same to the existing position, connecting with HT/LT cables and earthing strip and testing complete including necessary Transportation [If required] to the work shop and back and including Dehydration and refilling of existing or new transformer oil of required quantity. Note: Dehydration of oil and new Transformer Oil shall be measured separately. HT & LT Bushing, Tap Changer will be measured & paid separately. The rate quoted is deemed to be inclusive of cost of Cork Sheet & Packing Material etc.
As Per Serial Item No. 92 above but of capacity 200 to 300 KVA Complete all as specified and as directed.
As Per Serial Item No. 92 above but of capacity 314 to 400 KVA Complete all as specified and as directed.
Supply only Transformer HT Bushing, Porcelain with Copper Stud, Nuts, Bolts, Washers, Gasket, Oil Seal suitable for outdoor type Transformer of capacity up to 160 KVA Complete all as specified and as directed.
As Per Serial Item No. 95 above but of capacity 200 to 300 KVA Complete all as specified and as directed.
As Per Serial Item No. 95 above but of capacity 400 to 500 KVA Complete all as specified and as directed.
Supply only Transformer LT Bushing, Porcelain with Copper Stud / Bar, Nuts, Bolts, Washers, Gasket, Oil Seal suitable for Indoor / Outdoor type Transformer of capacity up to 160 KVA Complete all as specified and as directed.
As Per Serial Item No. 98 above but of capacity 200 to 300 KVA Complete all as specified and as directed.
As Per Serial Item No. 98 above but of capacity 400 to 500 KVA Complete all as specified and as directed.
Supply only Vacuum Interrupter as per existing suitable for 11 KV VCB Trolley Complete all as specified and as directed.
S & F in repairs Epoxy LV Bushing suitable for 1000 KVA Step up Transformer of Make CG with Copper Busbar after taking proper shutdown of transformer, disconnecting the cables, draining out the Transformer Oil in barrels, opening the top cover Complete all as specified and as directed. Note: The quoted rate is inclusive of connecting back the top cover, Filling the drained transformer Oil, connecting back the cables and checking for any leakages. Rate quoted is also deemed to be inclusive of Gaskets required.
M & L for Inspection and carrying out B-Checks of 11 KV, 2000 KVA, HT DG Set Once in Six months or 300 Hours of Run whichever is earlier installed at various locations by Representative / Authorised Service Engineer of OEM of the DG Set including inspection, maintenance, changing all types of filters including replacement of Lub Oil Filter, Fuel Filter, Bypass Filter, cleaning of Air Filter using Pressure Air, Corrosion Inhibitor, O Ring, Gaskets, Screws etc. and servicing of DG Set including Alternator, Non AMF / AMF Panels connected to DG Sets for routine check-up including routine / preventive maintenance checks, checking up of engine and alternator for the smooth functioning as per the Manufacturer’s instructions including checking of Engine Oil Level, Oil Bath Cleaner Oil Level, Draining Sediments from Fuel Tank, checking of Pre Cleaner Dust Pan, Air Cleaner Restriction, Coolant Level, Recording Oil Pressure, Checking / Tightening of all Bolts / Nuts of Engine and Alternator, checking of AVM Pads, Diaphragm Coupling, Air Piping, cleaning of Oil Bath Air Cleaner Tray Screen, check / adjust Belts, checking Battery Voltage, Water Level and apply Jelly on Terminals, checking Fan Hub / Air Blower Hub and Water Pumps, cleaning of electrical connections with CTC solution, checking of safety controls, cleaning of Cooling System, cleaning of Engine and Radiator Assembly, including cleaning of Air Filter using Pressure Air, Corrosion Inhibitor, O Ring, Gaskets, Screws etc. and draining out old engine oil from oil chamber and removing deposited material including applying Grease, CRC in moving parts and draining out water from Radiator Assembly and refilling new after mixing with Coolant including tightening of all inlet and outlet connections and replacing minor items such as Hose Clamp, Screws, Washers etc., cleaning of Roof, Floor of the DG Set Room complete all as specified and as directed. Note: The B-Check includes carrying out preventive maintenance including replacing minor unserviceable / worn out spares to keep the DG Set for trouble free functioning. The rate quoted is deemed to be including all the minor spares such as screws, clips, washers, distilled water, electrolyte, etc. All other Spares, Engine Oil & Coolant will be measured and paid separately as supply only under relevant items of this schedule. Contractor shall attend the break down at any time and place during the contract period. General maintenance is indicative only. The contractor shall also carry out other necessary maintenance task as required and as directed. The B-Check & servicing shall be done through authorised service agency of OEM only.
Supply only Lub Oil Filter [Catalogue No: P4324909 of Perkins] complete all as specified and as directed.
Supply only Fuel Filter Primary [Catalogue No: P759205 of Perkins] complete all as specified and as directed.
Supply only Element Air Filter [Catalogue No: P4526544 of Perkins] complete all as specified and as directed.
Supply only Antifreeze Premix Coolant Inhibitor extended Life Type [Catalogue No. PI60HOAT of Perkins] complete all as specified and as directed.
Supply only Diesel Engine Oil [DEO] [Catalogue No. PT430313 of Perkins] complete all as specified and as directed.
Supply only Tappet Cover Gasket [Catalogue No: PSE478F of Perkins] complete all as specified and as directed.
DELTA ELECTRICALS
N Rathinam
PTech Engineers
KAPOOR AUTOMOBILES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .